Raising the bar on performance for Atrial Flutter

Raising the bar on performance
for Atrial Flutter
Blazer Prime® XP Temperature Ablation
Catheter and Blazer® Dx-20 Bidirectional
Duodecapolar Diagnostic Catheter.
Blazer® Dx-20 Bidirectional Duodecapolar Diagnostic Catheter
High-performance Blazer® Catheter platform provides consistent steering
Bidirectional Duodecapolar Diagnostic
Catheter on Blazer Catheter Platform.
Blazer® Dx-20 Diagnostic Catheter
Super Large Curve.
Backsteering and bidirectional to facilitate CS access
Curve-lock for stable positioning in CS
Soft, extended distal tip
20-electrodes for streamlined electrogram assessment
Blazer Prime® XP Catheter
One Platform,
Multiple Benefits
Blazer® Dx-20 Catheter
Left anterior oblique fluoroscopic image showing the Blazer Prime®
XP Temperature Ablation Catheter and the Blazer® Dx-20 Bidirectional
Duodecapolar Diagnostic Catheter spanning the cavotricuspid isthmus.
Mapping the Atrial Flutter Circuit
I
II
aVL
aVF
HRA
ABL d
ABL
HALO 1
HALO 2
HALO 3
HALO 4
HALO 5
HALO 6
HALO 7
HALO 8
HALO 9
HALO 10
Stim 1
Intracardiac electrograms acquired with Blazer® Dx-20 Bidirectional
Duodecapolar Diagnostic Catheter (HALO 1 through HALO 10) and with
Blazer Prime® XP Temperature Ablation Catheter (ABL and ABLd).
Blazer Prime® XP Temperature Ablation Catheter
and maneuverability between diagnostic and therapeutic catheters.
Better tip stability and durability
Fiber-reinforced distal section and more
rugged center support optimize tip control
and durability:
Blazer Prime® XP Catheter
Improves lateral contact strength1
Blazer® Dx-20 Catheter
Increases backsteering strength
2
Enhances distal torque3
Right anterior oblique fluoroscopic image showing the Blazer Prime®
XP Temperature Ablation Catheter and the Blazer® Dx-20 Bidirectional
Duodecapolar Diagnostic Catheter spanning the cavotricuspid isthmus.
Better Torqueability
Extra support in proximal shaft is designed to:
Enhances the “push” response from catheter handle to tip
Contribute to better overall torque of the catheter
Excellent Clinical Results
4
# of Procedures = 250
8mm Tip
10mm Tip
94% Acute Success
96% Chronic Success (6-month follow up)
8% Major Complications
1
2
3
4
Lateral contact bench testing performed by Boston Scientific. N=5. Data on file.
Backsteering bench testing performed by Boston Scientific. N=5. Data on file.
Distal torque bench testing performed by Boston Scientific. N=5. Data on file.
Summary of Safety and Effectiveness Data. Blazer® II XP Cardiac Ablation Catheter. Boston Scientific Corporation, 2003.
Bench testing results may not necessarily be predictive of clinical performance.
BLAZER PRIME® XP TEMPERATURE ABLATION CATHETER INDICATIONS FOR USE The Boston Scientific Corporation Blazer Prime XP Catheter is indicated for use with the BSC high power
Cardiac Ablation Controllers (the Maestro 3000® Controller, the EPT- 1000XP™ Controller, and the EPT-1000XPT™ Controller) and Accessories for the treatment of sustained or recurrent type I
atrial flutter in patients age 18 or older. The BSC high power Cardiac Ablation Controllers and Accessories are indicated for use in conjunction with standard and high power catheters for cardiac
ablation procedures. CONTRAINDICATIONS Do not use this device: in patients with active systemic infection; via the transseptal approach in patients with left atrial thrombus or myxoma; via
the retrograde approach in patients with aortic valve replacement. WARNINGS Before operating the device, read these warnings carefully: Peri-procedural anti-coagulation therapy is at the discretion of the physician, however, patients with a history of thromboembolic events may require therapeutic anti-coagulation therapy, during and post-ablation to reduce the incidence of major
complications. Because the long-term effects of exposure to ionizing radiation are unknown, careful consideration should therefore be given to pregnant women and pre-pubescent children.
Pacemakers and implantable cardioverter/defibrillators can be adversely affected by RF signals. It is important to: a. Retain temporary external sources of pacing available during ablation. b.
Reprogram the pacing system temporarily to minimum output or 000 mode to minimize risk of inappropriate pacing. c. Exercise extreme caution during ablation when in close proximity to atrial
or ventricular permanent pacing leads. d. Perform complete pacing system analysis on all patients after ablation. Implanted cardioverter/defibrillators should be deactivated during delivery of
RF power. Catheter entrapment within the heart or blood vessels is a possible complication of cardiac ablation procedures. The potential for catheter entrapment may be increased when the
catheter is positioned in the chordae tendinae. The occurrence of this complication may necessitate surgical intervention and/or repair of injured tissue. Care must be taken to ensure that any
equipment used in connection with the BSC catheters, be type CF, be defibrillation proof, meet EN 60601-1 electrical safety requirements, and comply with all local regulatory requirements for
the specified intended use. In the presence of anticoagulation, there may be an increased risk of bleeding from all causes. If there is uncertainty regarding the patient’s anticoagulation status or
rhythm prior to the atrial flutter procedure, there should be a low threshold to perform a transesophageal echocardiogram (TEE) prior to the procedure to confirm absence of thrombus in the left
atrial appendage. Do not pass the catheter through any prosthetic heart valve (mechanical or tissue), as this may cause entrapment of the catheter and/or damage to the prosthetic heart valve,
resulting in valvular insufficiency and/or premature failure of the prosthetic valve. PRECAUTIONS Observe these precautions, before using the device: Do not attempt to operate the Controller
before thoroughly reading the appropriate BSC high power Cardiac Ablation Controller & Accessories Operator’s Manual. The Blazer Prime XP Catheters are intended for use with the BSC high
power Controllers and accessories only. The Blazer Prime XP Temperature Ablation Catheter is highly torqueable. Over-rotating the handle and catheter shaft may cause damage to the distal
tip or catheter assembly. Do not rotate the handle and catheter shaft more than one and one-half times the full rotation (540 degrees). If the desired catheter tip position is not achieved, adjust
the catheter’s curve to disengage the catheter tip from the heart wall before resuming rotation of the handle and catheter shaft. Careful catheter manipulation must be performed in order to
avoid cardiac damage, perforation, or tamponade. Catheter advancement should be done under fluoroscopic guidance. Do not use excessive force to advance or withdraw the catheter when
resistance is encountered. Excessive bending or kinking of the catheter shaft may damage internal wires. Manual pre-bending of the distal curve can damage the steering mechanism and may
cause patient injury. Cardiac ablation procedures should be performed only by physicians thoroughly trained in the techniques of RF Powered Catheter Ablation in a fully-equipped electrophysiology laboratory. Unlike with conventional catheters, a sudden rise in system impedance is not an indication of coagulum formation. Therefore, to minimize coagulum, it is recommended that
the catheter periodically be removed and the distal tip cleaned after each line of block. Adequate filtering must be used to allow continuous monitoring of the surface electrocardiograms (ECG)
during radiofrequency power applications. When using Blazer Prime XP Catheters, it is required that two Dispersive Indifferent Patch (DIP) Electrode Pads satisfying the requirements of IEC
60601-1/IEC 60601-1-2 be used as the ablation return electrodes or skin burns may result. Use of only one DIP electrode will not allow the operator to fully access the higher power capabilities
of the Controller. Placement of the DIP electrodes on the thigh could be associated with higher impedance, which could result in automatic RF power shut-off. During power delivery, the patient
should not be allowed to come in contact with grounded metal surfaces. Apparent low power output or failure of the equipment to function correctly at normal settings may indicate faulty
application of the DIP electrodes or failure of an electrical lead. Do not increase power before checking for obvious defects or misapplication. Regularly inspect and test re-usable cables and
accessories. Potential Adverse Events Potential adverse events (in alphabetical order), that may be associated with cardiac catheterization and ablation include, but are not limited to: allergic
reaction (including anaphylaxis), angina, arrhythmias, arterial or pulmonary embolism, arterial-venous fistula, atrioventricular node damage (transient/permanent), back pain and/or groin pain,
cardiac perforation, cardiac respiratory arrest, catheter entrapment, complete heart block (transient/permanent), cerebral vascular accident, chest pain/discomfort, complications of sedative
agents (e.g. aspiration pneumonia), death, effusion (pericardial/pleural), hematoma/bruising, hemoptysis, hemorrhage, hemothorax, hypotension, infection, myocardial infarction, nerve palsy
or weakness, pericarditis, phrenic nerve damage/diaphragmatic paralysis, pleurisy, pneumothorax, pulmonary edema, pseudoaneurysm, radiation exposure, sinoatrial node damage, skin burn
(defibrillator/cardioverter/radiation), tamponade, transient ischemic attack (TIA), valvular damage, vasovagal reactions, visual blurring.
BLAZER® Dx-20 DUODECAPOLAR BIDIRECTIONAL DIAGNOSTIC CATHETER INDICATIONS FOR USE The Boston Scientific Corporation Blazer Dx-20 Catheter is intended for temporary use
in electrophysiology studies for intracardiac stimulation (pacing) and/or recording of electrical potentials. CONTRAINDICATIONS Caution should be exercised, in the use of these or any other
catheters, in patients with prosthetic valves. Patients with recurrent sepsis or with hypercoaguable state should not be considered candidates for transvascular catheters, since the catheter
could serve as a focal point for septic or blood thrombus formation. Care should be taken during placement and removal of this or any diagnostic catheter, so as to avoid disturbing permanent
internal pacing/defibrillation leads. The Blazer Dx-20 Catheter is contraindicated for transseptal approach in patients with atrial thrombus or myxoma, or interatrial baffle or patch. The Blazer
Dx-20 Catheter is contraindicated for use from the femoral approach in patients who have vena cava embolic protection filter devices or known femoral thrombus. WARNINGS The device(s)
should be used by physicians thoroughly trained in the techniques of invasive cardiology and in the specific approach to be used. Care must be taken to ensure that any equipment used in connection with the BSC Catheter meet IEC 60601-1 electrical safety and IEC 60601-1-2 electromagnetic compatibility requirements, be type CF, be defibrillation proof, system configurations meet
IEC 60601-1-1 electrical safety requirements and comply with local regulatory requirements for the specified intended use. The use of catheters or cables with unprotected male pin connectors
presents a risk of electrical hazard. Inadvertent attachment of pin connectors to power supply sockets of connectors could result in electrocution of the patient or operator. Do not use Blazer
Dx-20 Catheter as an internal defibrillation catheter. Doing so may result in perforation, arrhythmias, embolism, thrombus, and/or patient death. Diagnostic electrophysiology involves x-ray
exposure that presents the potential risk for somatic and genetic effects to both patients and laboratory staff due to the x-ray beam and intensity and duration of the fluoroscopic imaging. Steps
should be taken to minimize this exposure as much as possible. Careful catheter manipulation must be performed to avoid cardiac damage, perforation, or tamponade. Catheter advancement
should be performed under fluoroscopic guidance. Do not use excessive force to advance or withdraw the catheter when resistance is encountered. Stimulation of cardiac tissues caused by
pacing stimuli may lead to inadvertent induction of arrhythmias. These arrhythmias may require defibrillation that could also result in skin burns. Do not use if package is opened or damaged.
This catheter is not indicated for use in Cardiac Ablation or Coronary Artery Mapping. PRECAUTIONS Excessive bending or kinking of the catheter shaft may damage internal wires. Manual
prebending of the distal curve can damage the steering mechanism and/or electrical wires and may cause patient injury. Before using, check shelf life. Do not use catheter after expiration
date. ADVERSE EVENTS The following potential risks or discomforts may be associated with diagnostic BSC procedures. The frequency and severity of these adverse events can vary and may
necessitate additional medical intervention, including surgery. Allergic reaction, Arrhythmias, Cardiac or respiratory arrest, Cardiac valve damage, Catheter entrapment/entanglement, Chest
pain, Damage to vessel intima or cardiac structures, Death, Embolus, air embolus, Hematoma/ecchymosis, Hemorrhage, Hypotension, Infection, Myocardial infarction, Perforation, Pericardial
effusion, Pericarditis/pleuritis, Pneumothorax, Pseudoaneurysm, Pulmonary edema, Sinus or AV node injury, Stroke, Tamponade, Thrombosis, Vasovagal reaction, X-ray exposure. Warning
Contents supplied STERILE using an ethylene oxide (EO) process. Do not use if sterile barrier is damaged. If damage is found, call your Boston Scientific representative. For single patient use
only. Do not reuse, reprocess or resterilize. Reuse, reprocessing or resterilization may compromise the structural integrity of the device and/or lead to device failure which, in turn, may result
in patient injury, illness or death. Reuse, reprocessing or resterilization may also create a risk of contamination of the device and/or cause patient infection or cross-infection, including, but not
limited to, the transmission of infectious disease(s) from one patient to another. Contamination of the device may lead to injury, illness or death of the patient. After use, dispose of product and
packaging in accordance with hospital, administrative and or local government policy.
CAUTION Federal Law (USA) restricts this device to sale by or on the order of a physician. Carefully read all instructions prior to use. Observe all contraindications, warnings, and precautions
noted in these instructions. Failure to do so may result in patient complications. Boston Scientific relies on the physician to determine, assess, and communicate to each patient all foreseeable
risks of the procedure.