Straps & Ties A Angles and Z Clips Z2 clips secure 2x4 flat blocking between joists or trusses to support sheathing. MATERIAL: Z clips—see table. A21 and A23—18 ga.; all other A angles—12 ga. FINISH: Galvanized. Some products available in stainless steel or ZMAX® coating; see Corrosion Information, pages 14-17. INSTALLATION: • Use all specified fasteners. See General Notes. • Z clips do not provide lateral stability. Do not walk on stiffeners or apply load until diaphragm is installed and nailed to stiffeners. • F1 direction is loading into the part. These products are available with additional corrosion protection. Additional products on this page may also be available with this option, check with Simpson Strong-Tie for details. A44 Installation (A33 similar) Moisture barrier not shown These products are approved for installation with the Strong-Drive ® SD Connector screw. See page 24 for more information. Fasteners Base W1 W2 L Post Bolts Nails Bolts Nails A21 2 1 1⁄2 1 3⁄8 — 2-10dx1 1⁄2 — 2-10dx1 1⁄2 A23 2 1 1⁄2 2 3⁄4 — 4-10dx1 1⁄2 — 4-10dx1 1⁄2 A33 3 1 1⁄2 — 4-10d — 4-10d A44 4 9⁄16 4 3⁄8 1 1⁄2 — 4-10d — 4-10d A66 5 7⁄8 5 7⁄8 1 1⁄2 2- 3⁄8" MB 3-10d 2- 3⁄8" MB 3-10d 3 A88 8 8 2 3- 3⁄8" MB 4-10d 3- 3⁄8" MB 4-10d A24 3 7⁄8 2 2 1⁄2 1-1⁄2" MB — 1-1⁄2" MB 2-10d A311 11 3 5⁄8 2 1-1⁄2" MB — 1-1⁄2" MB 4-10d Factored Resistance (K D = 1.15) D.Fir-L S-P-F F2 F1 F2 F1 lbs lbs lbs lbs kN kN kN kN 405 260 335 185 1.80 1.16 1.49 0.82 815 715 725 510 3.63 3.18 3.23 2.27 1175 570 930 405 5.23 2.54 4.14 1.80 1175 485 930 345 5.23 2.16 4.14 1.53 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 1.Factored resistances have been increased 15% for earthquake or wind loading with no further increase allowed; reduce where other loads govern. 2.NAILS: 10dx1 1⁄2 = 0.148" dia. x 1 1⁄2" long, 10d = 0.148" dia. x 3" long. See pages 22-23 for other nail sizes and information. Model No. Z2 Dimensions (in) Ga W1 20 2 ⁄16 5 H 1 ⁄2 1 B 1 ⁄8 3 TF 1 ⁄8 3 Fasteners Total 4-10dx1 ⁄2 1 Z4 12 1 1⁄2 3 1⁄2 2 1⁄8 1 3⁄4 2-16d Z6 12 1 1⁄2 5 3⁄8 2 1 3⁄8 2-16d Z28 28 2 5⁄16 1 1⁄2 1 3⁄8 1 3⁄8 10dx1 1⁄2 Z38 28 2 ⁄16 2 ⁄2 1 ⁄8 1 ⁄8 10dx1 ⁄2 Z44 12 5 2 1⁄2 1 3 1⁄2 3 2 3 1 3⁄8 1 1 4-16d A24 Installation Moisture barrier not shown A311 Installation Straps & Ties Catalogue C-C-CAN2015 © 2015 SIMPSON STRONG-TIE COMPANY INC. Model No. Dimensions (in) Z4 Factored Resistance (K D = 1.00) D.Fir-L S-P-F lbs lbs kN kN 740 525 3.29 2.34 765 545 3.40 2.42 790 560 3.51 2.49 — — — — — — — — 1420 1010 6.32 4.49 1.Z28 and Z38 do not have nail holes. Fastener quantity and type shall be per Designer. 2.Z4 and Z6 resistances apply with a nail into the top and a nail into the seat. 3.Factored resistances for Z clips cannot be increased for short term loading. 4.NAILS: 16d = 0.162" dia. x 3 1⁄2" long, 10dx1 1⁄2 = 0.148" dia. x 1 1⁄2" long. See pages 22-23 for other nail sizes and information. (Others similar) A21/A23 Installation Typical Z2 Installation 193
© Copyright 2024