SUBMITTAL FORM NO. 2895-10P MicroMetl DATE: 2/12 SUBMITTED TO COMPANY: Down Discharge Economizer with 100% Relief Capability for Carrier 48/50TC A/B04-A/B07; 50TCQ A04-A07; 48/50LC,HC A04-A06; 50HCQ A04-A06; 48/50TF,TM,HJ,TFQ 004-007; 48/50HE 003-006 Units 0688-0101 Static Pressure Loss Through Economizer DRAWN BY: JOB NAME: EQUIPMENT: NOTES: FEATURES: • Gear driven dampers eliminate slippage associated with standard linkage. • Designed specifically for down discharge applications. Easy to install. Easy to service. • Lower static pressure loss through economizer dampers. • Greater barometric relief capabilities. • Factory assembled rainhood with aluminum filters in both outside air and relief hoods. • Uses filter access door shipped with HVAC unit. • Rainhoods are sloped for water run-off. • Hardware cloth over relief damper. Part Number: 0688-0101 0688-0101 Barometric Relief ECONOMIZER PART NO.S 0688-0101-00920 Economizer w/ no controls 0688-0101-9J920 Economizer w/ fixed dry bulb controls 0688-0101-54920 Economizer w/ modulating enthalpy controls 0688-0101-9A920 0688-0101-9J920-A Economizer w/ modulating adjustable dry bulb controls Access door shipped with HVAC unit Drive gear attached to the motor Side View Filters Economizer motor and harness Weight: 63 lbs Gear driven dampers 19 1/4" Evaporation coil Sloped Economizer includes Honeywell W7212 controller capable of CO2, demand control and power exhaust control. Rainhood ships fully assembled Outside air Aluminum water entrainment filters Relief air THIS DOCUMENT IS THE PROPERTY OF MICRO METL CORPORATION AND IS DELIVERED UPON THE EXPRESS CONDITION THAT THE CONTENTS WILL NOT BE DISCLOSED OR USED WITHOUT MICRO METL'S WRITTEN CONSENT. MICROMETL CORPORATION • 3035 N. SHADELAND AVENUE, SUITE 300 • INDIANAPOLIS, IN. 46226 • 1-800-662-4822 ••• MICROMETL WEST • 905 SOUTHERN WAY • SPARKS, NV 89431 • 1-800-884-4662 INSTALLATION INSTRUCTIONS MicroMetl For 0688-0101, 0201 Down Discharge Economizer INSTRUCTIONS: STEP #1 ILL. #1 Top filter access door shipped with HVAC unit. This door is used with the economizer 1A. Disconnect power to HVAC until 1B. Remove top filter door, shipped on HVAC unit. Set aside for use later. Remove and discard the lower panel shipped with HVAC unit. Save HVAC unit’s lower panel. Remove and discard. STEP #2 this pane l Disc ard t pane his l 2A. Unpack the MicoMetl economizer. 2B. Remove discharge air sensor (yellow) from economizer and install in supply air chamber/duct. (page 2, ILL. 10) 2C. Slide economizer into return air chamber, being sure not to pinch harness (ILL. 2). Rear flange of economizer slides under tab on duct flanges. (See Rear Flange Detail.) Secure economizer in place through mating holes. ILL. #2 Unit STEP #3 3A. The 0688-0201 hood requires field assembly of the divider/base to the sides using the provided pre-punched holes. The 0688-0101 is factory assembled. 3B. Install rain hood per (ILL> 2 & 4). Line up pre-punched holes in hood with holes in HVAC unit and install screws. Install aluminum filter in hood. (ILL. 5) Economizer Specification (in inches) MicroMetl Part No. A 3-6 ton 0688-0101 19 1/4 7½-12½ ton 0688-0201 29 3/8 Unit Size 3C. Install HVAC unit filter access door over rain hood. 3D. Motor and logic access provided behind filter access door. Rear Flange Detail ILL. #3 Filter Rain hood Economizer Slide economizer rear flange into tab Slide filter under screws Rain Hood Use clips to hold filter in place Economizer Unit base MMC Economizer clip on HVAC unit Installation hook on the hood Hood Latch Detail ILL. #4 3035 N. Shadeland Ave, Suite 300 Indianapolis, IN. 46226 MMC WEST ILL. #5 202 South 18th. St. Sparks, NV. 89431 Manufacturer reserves the right to discontinue, or change at any time, specifications, designs and prices without notice and without incurring obligations. 1 Form No. 2901-5P Copyright MicroMetl Corporation 2003 All rights reserved STEP #3 - IMPORTANT! - please read! Use 1 of the next 2 pages to wire the economizer. To determine which page to use, check outdoor sensor type. Compare sensor type to wiring instruction description at top of each page. Cycle test and adjust. 0688-0101 Static Pressure Loss Through Economizer 0.400 0.350 0.2 Static Pressure Static Pressure (in. w.g.) 0.25 Return Air 0.15 0.1 Outside Air 0.05 0 0688-0201 Static Pressure Loss Through Economizer 0.300 Return Air 0.250 0.200 0.150 Outside Air 0.100 0.050 0 500 1000 1500 2000 2500 0.000 3000 0 Airflow (cfm) 1000 2000 3000 Airflow (cfm) 0688-0100 Barometric Relief 3000 Relief Airflow (CFM) 2500 2000 1500 1000 500 0 0 0.05 0.1 0.15 0.2 0.25 0.3 0.35 Static Pressure (in w.g.) ILL. #6 ILL. #7 Side View Filter access door shipped with HVAC unit. Lift up and out to remove. Outside air hood Mount discharge sensor here Indoor Blower HVAC Unit Filter Always disconnect power before changing filters 2 4000 5000 6000 Wiring Instruction for Use with 12 Pin Plug Enthalpy and Dry Bulb PLEASE READ CAREFULLY! Terminal Board 9962-0305 Wiring Harness with 12 pin plug Follow these instruction if the economizer wiring harness in the HVAC unit has a 12 pin plug. Factory installed harness ILL. #6 Factory attached to terminal board Control compartment IMPORTANT! Economizer and hood CONTROL SYSTEMS NOTES: 1. The HVAC unit has an economizer wiring harness factory installed. It attaches to the 9962-0305 economizer harness on one end and is factory attached to the unit’s terminal board on the other end (ILL. #6). 2. The 9962-0047 pigtail and the 9962-0073 adaptor harness are available from factory for obsolete units with 9 pin plug. 9962-0305 Wiring Harness WIRING INSTRUCTION for use with 12 pin economizer plug. STEP #4 • Plug the economizer’s 9962-0142 wiring harness into the HVAC unit’s harness ILL. #6 Thermostat Connection Board Red 1 STEP #5 NOTE: There are (4) loose wires available in the HVAC unit. Connect the pink and violet wires to the discharge sensor. Do not use the brown and white wires. 4 4 Maintains mixed air temperature between 50O-56O. To compressor lockout “1” on HVAC unit MicroMetl discharge sensor (mount in blower compartment) To compressor lockout “2” on HVAC unit (if 2 stage is used) Connect the pink and violet wires to the discharge sensor. Do not use brown or white wires Do not use Brw Plug harness installed in HVAC units 3 Compressor lockout switch on some models. Lockouts out compressors at 35O F (+/- 5O) Field wire if desired. Remove this jumper / resistor when using differential enthalpy. 2 • Mount the MicroMetl discharge sensor in the unit blower compartment. (See ILL. 6) If using differential enthalpy, setpoint should be at “D”. Enthalpy or adj. dry bulb MicroMetl economizer harness / plug 620 OHM Resister Actuator Logic + SR Exhaust Fan Set Point Minimum Position Setting DCV / CO2 maximum setpoint Red DCV / CO2 activation setpoint Power exhaust fan connection To optional CO2 sensor EF EF1 AQ AQ1 Black N 24V HOT 3 Enthalpy changeover setpoint 1 Fixed Dry Bulb Wiring Instruction for Use with 12 Pin Economizer Plug PLEASE READ CAREFULLY! Terminal Board 9962-0307 Wiring Harness with 12 pin plug Follow these instruction if the economizer wiring harness in the HVAC unit has a 12 pin plug. Factory installed harness ILL. #10 Factory attached to terminal board Control compartment IMPORTANT! Economizer and hood CONTROL SYSTEMS NOTES: 1. The HVAC unit has an economizer wiring harness factory installed. It attaches to the 9962-0307 economizer harness on one end and is factory attached to the unit’s terminal board on the other end (ILL. #10). 2. The 9962-0047 pigtail and the 9962-0073 adaptor harness are available from factory for obsolete units with 9 pin plug. Fixed Dry Bulb - 9962-0307 Wiring Harness WIRING INSTRUCTION for use with 12 pin economizer plug. STEP #4 • Plug the economizer’s 9962-0086 wiring harness into the HVAC unit’s harness ILL. #14 Thermostat Connection Board 1 Red 2 STEP #5 • Mount the MicroMetl discharge sensor in the unit blower compartment. (See ILL. 6) 3 NOTE: There are (4) loose wires available in the HVAC unit. Connect the pink and violet wires to the discharge sensor. Do not use the brown and white wires. 4 5 Enthalpy changeover potentiometer not used with fixed dry bulb Compressor lockout switch on some models. Lockouts out compressors at 35O F (+/- 5O) Field wire if desired. If replacing the fixed dry bulb with either an adjustable dry bulb or enthalpy sensor, the 620 OHM resistor must be removed. Fixed dry bulb allows for free cooling when outside temperature is less than 70O. Maintains mixed air temperature between 50O-56O. MicroMetl discharge sensor (mount in blower compartment) To compressor lockout “1” on HVAC unit Connect the pink and violet wires to the discharge sensor. Do not use brown or white wires To compressor lockout “2” on HVAC unit (if 2 stage is used) Do not use Brw 5 Plug harness installed in HVAC units Enthalpy or adj. dry bulb 620 OHM Resister MicroMetl economizer harness / plug Actuator Logic + SR Red Exhaust Fan Set Point Minimum Position Setting DCV / CO2 maximum setpoint DCV / CO2 activation setpoint Power exhaust fan connection To optional CO2 sensor EF EF1 AQ AQ1 Black N 24V HOT 4 Enthalpy changeover setpoint 1 MicroMetl Integrated Economizers The purpose of an economizer is to use outdoor air for cooling, whenever possible, to reduce compressor operation. During the unoccupied period, the actuator will override minimum position setting and drive fully closed. On a loss of power, the actuator will spring return fully closed. The economizer system initially responds to a signal from the cooling thermostat and functions as a true first stage for cooling, while providing maximum fuel economy. The economizer automatically locked out during the heating mode and holds the outdoor air damper at the minimum position settings. When in heating operation, or when outdoor air temperature or enthalpy conditions are high, economizer operation is locked out, and actuator os held at minimum position. The staging relay is used when the first stage compressors must provide mechanical cooling when assisting the economizer. During the occupied period, on a call for cooling, when outdoor air temperature or enthalpy conditions are low, the economizer actuator will proportion to maintain between 50O F and 56O F at thermistor discharge sensor. The staging relay can be omitted when the second stage compressors can be used to assist the economizer with mechanical cooling. If the mixed or discharge temperature is above 56O F, actuator will open to admit additional outdoor air until the temperature return to the 50O to 56O F range. If the mixed or discharge air temperature is below 50O F, the actuator will proportion closed, shutting the outdoor air damper until the temperature returns to the 50O to 56O F range. During the occupied period, the actuator will not close past the minimum position. If the fully open actuator cannot satisfy the space demand, mechanical cooling is sequenced on. 5 Component Description 6 1 4C 3 4A 2 4B 5 1. Damper actuator ...9901-1865 provides 24v modulating control of economizer damper, 25 in. lb. of torque, (Honeywell M7215a-1008) 4A. Entahlpy sensor ...9901-0018 senses and combines temperature and humidity of outdoor air. And also provides the signal to the economizer logic. (Honeywell C7400A used on 1008-0100) 2. Discharge sensor ...9901-0001 provides a signal (3000 Ohms at 25O C or 77O F) to the actuator during free cooling or economizer mode. The signal opens the economizer damper until the discharge temperature drops below 55O. At this time the signal causes the motor to modulate the damper and mix outside air with return air to maintain a 50O F to 56O F discharge temperature. 4B. Adjustable dry bulb ...9901-2251 senses temperature of outside air and provides signal to the economizer logic. (Honeywell C7660A-1001 used on 1009-0100) 4C. Fixed dry bulb ...9901-0183 senses temperature of outside air. If below 70O setpoint, allows for free cooling. 3. Economizer logic ...9901-1805 accepts input from discharge sensor and outside air sensor. Analyzes input to control actuator modulation and economizer switching. Logic also houses minimum position adjustment, enthalpy or adjustable dry bulb adjustment, power exhaust control, and CO2 demand control ventilation adjustment. When used with optional differential sensor in the return air, the logic is capable of selecting the most economical air available for cooling. (Honeywell W7212-C) 6 5. Wire harness color coded and pre-wired to actuator and economizer logic. 6. Compressor lockout ...9901-0252 locks out compressor when temperature falls below 35O F (+/- 5O F). Shipped with economizer, but must be field wired, if desired.
© Copyright 2024