Caps & Bases BC/HBC/BCS Post Caps and Bases Pilot holes for manufacturing purposes (Do not install bolts) (Typ.) Pilot holes for manufacturing purposes (Do not install bolts) (Typ.) Base Bottom Beam Flanges Post Flanges BC60 Half Base Post Flanges (others similar) BC4 Cap/Base (BC46, BC6 similar) Caps & Bases The BCS allows for the connection of 2-2x’s to a 4x post or 3-2x’s to a 6x post. Double shear nailing between beam and post gives added strength! The BC/HBC series offers dual purpose post cap/base for light cap or base connections. MATERIAL: HBC—12 gauge; all others—18 gauge FINISH: HBC—HDG; all others—galvanized. Some products available in ZMAX® coating; see Corrosion Information, pages 14-17. INSTALLATION: • Use all specified fasteners. See General Notes. • Do not install bolts into pilot holes. • BCS—install dome nails on beam; drive nails at an angle through the beam into the post below to achieve the table loads • BC—install with 16d commons or 16dx2 1⁄2" nails. • Post bases do not provide adequate resistance to prevent members from rotating about the base and therefore are not recommended for non top-supported installations (such as fences or unbraced carports). These products are available with additional corrosion protection. Additional products on this page may also be available with this option, check with Simpson Strong-Tie for details. These products are approved for installation with the Strong-Drive ® SD Connector screw. See page 24 for more information. Model No. Dimensions (in) W1 W2 Fasteners L1 L2 H1 BC4 7 3 ⁄16 3 ⁄16 2 ⁄8 7 2 ⁄8 3 BC46 3 9⁄16 5 1⁄2 4 7⁄8 2 7⁄8 3 1⁄2 H2 Beam Post Base Bottom Factored Resistance (K D = 1.15) D.Fir-L S-P-F Uplift Lateral Uplift Lateral lbs lbs lbs lbs kN kN kN kN CAPS BC4R 9 3 6-16d — 2 1⁄2 12-16d 6-16d — 4 4 4 3 5 1⁄2 5 1⁄2 4 3⁄8 4 3⁄8 3 3⁄8 6 6 6 6 3 3 12-16d 12-16d — BC8 7 1⁄2 7 1⁄2 7 1⁄2 7 1⁄2 4 4 12-16d 12-16d — BCS2-2/4 3 1⁄8 3 9⁄16 2 7⁄8 6-10d — BCS2-3/6 4 5⁄8 5 9⁄16 4 3/8 2 7⁄8 3 5⁄16 2 15⁄16 12-16d 6-16d — BC4O 3 9⁄16 — 3 1⁄4 — 2 1⁄4 — 6-16d — 4-16d HBC4OHDG 3 9⁄16 — 3 1⁄4 — 2 1⁄4 — 6-16d — 4-16d BC4OR 4 — 4 — 3 — 6-16d — 4-16d BC46O 5 1⁄2 — 3 3⁄8 — 3 — 6-16d — 4-16d BC6O 5 1⁄2 — 5 1⁄2 — 3 — 6-16d — 4-16d HBC6OHDG 5 1⁄2 — 5 1⁄2 — 3 — 6-16d — 4-16d 6 — 6 — 3 — 6-16d — 4-16d 7 1⁄2 — 7 1⁄2 — 4 — 6-16d — 4-16d 8 — 8 — 4 — 6-16d — 4-16d BC6R 3 6-16d 4 BC6 Catalogue C-C-CAN2015 © 2015 SIMPSON STRONG-TIE COMPANY INC. 9 12-16d 12-16d — 3 3⁄8 12-16d 12-16d — 2 7⁄8 2 15⁄16 2 15⁄16 8-10d 875 3.90 1415 6.30 875 3.90 1450 6.46 1560 6.94 2545 11.34 1190 5.30 1370 6.10 1495 6.66 1495 6.66 1495 6.66 3145 14.01 3145 14.01 3145 14.01 1560 6.95 2445 10.89 620 2.76 1005 4.48 620 2.76 1030 4.59 1110 4.94 1810 8.06 845 3.76 970 4.32 1060 4.72 1060 4.72 1060 4.72 2765 12.32 2765 12.32 2765 12.32 1370 6.09 1735 7.73 510 2.27 510 2.27 510 2.27 510 2.27 510 2.27 510 2.27 510 2.27 510 2.27 510 2.27 1050 4.68 1050 4.68 1050 4.68 1050 4.68 1050 4.68 1050 4.68 1050 4.68 1050 4.68 1050 4.68 360 1.60 360 1.60 360 1.60 360 1.60 360 1.60 360 1.60 360 1.60 360 1.60 360 1.60 960 4.28 960 4.28 960 4.28 960 4.28 960 4.28 960 4.28 960 4.28 960 4.28 960 4.28 BCS2-2/4 U.S. Patent 5,603,580 Pilot holes for manufacturing purposes (Do not install bolts) (Typ.) BASES BC6OR BC8O BC8OR 1.Factored resistances have been increased 15% for earthquake or wind loading with no further increase allowed; reduce where other loads govern. 2.Uplift values shown for BCO are only applicable for short-term loading. Do not use these products for other load durations. 3.Uplift resistances do not apply where Bases are nailed into the end grain of post as per 12.9.3.4 CSA O86-14. 4.Structural composite lumber columns have sides that show either the wide face or the edges of the lumber strands/veneers. Values in the tables reflect installation into the wide face (see technical bulletin T-SCLCOLUMNCAN for details). 5.Factored resistances shown assume dry service condition (KSF = 1.00). Multiply table values by 0.67 under wet service conditions. 6.NAILS: 16d = 0.162" dia. x 3 1⁄2" long, 10d = 0.148" dia. x 3" long. See pages 22-23 for other nail sizes and information. BC8 Cap/Base (BC4R, BC6R similar) Lateral Typical BCS Installation 65
© Copyright 2024