Kappa Rev LGW 245÷1229 kW Air cooled & freecooling modular screw chiller General Bullet points High energy efficiency chillers and freecooling chiller with screw compressors and shell&tube exchanger. ►► High seasonal efficiency ►► Eurovent A Class Unit ►► Low refrigerant charge ►► Microchannel condensing coil ►► Multilogic and Multifree function ►► Integrated web server ►► Wide operating limits Configurations HE: High efficiency unit LN: Low noise unit SLN: Super Low noise unit DS: Unit with desuperheaters DC: Heat exchange condenser HAT: unit for high temperature of external air Pump and integrated buffer tank available as option ►► Integrated hydraulic modules also with a buffer tank. ►► Three types of pumps: standard, oversize and for high percentages of glycol (e.g. up to 50%). F-gases Fluorinated gases (‘F-gases’) are man-made gases used in a range of industrial applications. Because they do not damage the atmospheric ozone layer, they are often used as substitutes for ozone-depleting substances. However, F-gases can stay in the atmosphere for centuries and contribute to a global greenhouse effect, with a global warming effect up to 8000 times greater than carbon dioxide (CO2), and their emissions are rising strongly. The three groups of F-gases are hydrofluorocarbons (HFCs), perfluorocarbons (PFCs) and sulphur hexafluoride (SF6). HFCs are by far the most relevant F-gases from a climate perspective. F-gases account for 2% of the EU’s overall greenhouse gas emissions, but F-gas emissions have risen by 60% since 1990 in contrast to all other greenhouse gases, which have been reduced. F-gas emissions to be cut by two-thirds by 2030 The European Union is therefore taking regulatory action to control F-gases as part of its policy to combat climate change. A new Regulation, which replaces the first and applies from 1 January 2015, strengthens the existing measures and introduces a number of far-reaching changes. By 2030 it will cut the EU’s F-gas emissions by two-thirds compared with 2014 levels. This represents a fair and cost-efficient contribution by the F-gas sector to the EU’s objective of cutting its overall greenhouse gas emissions by 80-95% of 1990 levels by 2050. The expected cumulative emission savings are 1.5 Gigatonnes of CO2-equivalent by 2030 and 5 Gigatonnes by 2050. The latter number is more than the CO2 produced by a billion return flights from Paris to New York. DANGEROUS MILDLY NON CURRENT FLAMMABLE FLAMMABLE REFRIGERANT Alternative refrigerant going forward for commercial HVAC application R134a GWP=2088 R134a & R1234ze R32 & R1234ze blended blended GWP 600 GWP 600 R1234ze R32 GWP <1 R1234yf GWP 675 GWP <1 R290 R717 GWP 3 GWP 0 HIGH FLAMMABLE F-gas emissions to be cut by two-thirds R410A GWP=1430 (Propane) 2030 (Ammonia) HIGH FLAMMABLE AND TOXIC HFOs ODP=0 GWP<1 R1234yf R1234ze 2006 R744 (Carbon dioxide) GWP 1 HIGH WORKING PRESSURE GWP Global-warming potential (GWP) is a relative measure of how much heat a greenhouse gas traps in the atmosphere. It compares the amount of heat trapped by a certain mass of the gas in question to the amount of heat trapped by a similar mass of carbon dioxide. A GWP is calculated over a specific time interval, commonly 20, 100 or 500 years. GWP is expressed as a multiplying factor of carbon dioxide value that is standardized equal to GWP=1. In the past, refrigerants artificial category HCFC (HydroChloro-Fluoro-Carbides) were used but, later were banded because they were one of main causes of Ozone layer depletion (high ODP value). Currently mainly used refrigerants as HCFC subsitutes, belong to HFC category (Hydro-Fluoro-Carbides) with ODP=0, but with still strong greenhouse effect (HIgh GWP). Natural refrigerants (R744, R717) and hydrocarbons HC (R290) represent an alternative to HFCs but with several implications and limitations. New chemical refrigerants belonging to HFO category (Hydro-Fluoro-Olefin) like R1234ze/R1234yf offer a good alternative to HFC, offering: • Adaptation to exhisting Chillers Design • Higher Efficiency • Longer life of components • Suitable for all climate zones HFCs ODP=0 GWP 1400÷3500 R410A R407C R404A R134a mid 1990 HCFCs high ODP & GWP R123 R22 CFCs very high ODP & GWP R12 1990 WIDE CAPACITY RANGE STD | 244÷1.226 kW on 25 sizes 2,3,o 4 compressors /HE - high efficiency | 263÷1.042 kW on 18 sizes /SLN - super low noise | 253÷1.004 kW on 18 sizes 200 400 600 chiller only 800 1000 1.200 freecooling available CONTROL FUNCTION (HFO OPTIMIZED) Unit management by integrated web server page (alarms, set points, antisticking function...) User friendly interface based on visual icons MULTILOGIC FUNCTION Up to 32 units (1 Master e 31 Slave) connected to the same hydronic circuit Management of units with different logics and priority levels ETHERN ET USB MULTIFREE FUNCTION Maximise the efficiency using the freecooling from stand-by unit in n+1 configuration. MICROCHANNEL ALUMINIUM COIL Kappa Rev LGW units use this new generation of condensing coil on chiller section as standard. This means: •Extended life cycle •10% overall chiller weight reduction •less air side pressure drop 30% less refrigerant LEAK DETECTION The unit is equipped of a leak detector located in the compressor compartement, with the pump down function that encloses the refrigerant in the condensing coil. R1234ze has been classified on safety group 2 for PED (european standard). Unit size Cooling capacity (A35; W7) Total absorbed power EER Efficiency class Water flow (A35; W7) Pressure drop (A35; W7) Unit size Cooling capacity (A35; W7) Total absorbed power EER Efficiency class Water flow (A35; W7) Pressure drop (A35; W7) 33.2 245 82 3,01 B 42,1 22 35.2 271 82 3,22 A 46,5 26 Kappa Rev STD 37.2 40.2 43.2 296 326 365 82 82 82 3,05 2,91 2,87 B B C 51,0 56,0 62,8 31 38 20 51.2 384 82 2,92 B 66,1 28 54.2 429 82 2,93 B 73,8 34 58.2 487 82 2,87 C 83,8 25 67.2 548 82 2,97 B 94,2 30 73.2 586 82 3,05 B 100,7 34 80.2 626 82 3,12 A 107,6 23 85.2 668 82 3,01 B 114,9 26 90.2 708 82 2,90 C 121,7 30 95.2 757 82 2,92 B 130,2 35 115.2 887 82 2,91 B 152,6 18 120.2 957 82 2,94 B 164,5 21 130.2 1027 82 3,00 B 176,6 23 140.3 1146 82 2,89 C 197,1 28 150.3 1192 82 2,89 C 205,0 24 160.3 1229 82 2,88 C 211,3 25 kW kW m3/h kPa kW kW m3/h kPa 100.2 105.2 791 832 82 82 2,90 2,89 C C 136,0 143,1 38 34 Kappa Rev HE m3/h kPa kW kW m3/h kPa 37.2 311 95 3,28 A 53,4 17 40.2 354 108 3,30 A 61,0 25 43.2 395 119 3,31 A 68,0 29 51.2 415 126 3,30 A 71,4 19 54.2 460 140 3,29 A 79,1 23 58.2 540 164 3,29 A 92,9 18 67.2 587 179 3,29 A 101,0 20 73.2 618 188 3,29 A 106,2 22 80.2 652 198 3,30 A 112,2 25 85.2 710 215 3,31 A 122,2 30 90.2 764 231 3,30 A 131,5 35 95.2 821 248 3,31 A 141,2 34 100.2 871 262 3,32 A 149,8 37 105.2 915 278 3,29 A 157,4 18 115.2 970 295 3,29 A 166,8 20 120.2 1044 317 3,29 A 179,5 23 MODULAR FREECOOLING AVAILABLE Kappa Rev LGW allow all combinations with 3 freecooling levels. Every chiller version can be couple with the different freecooling sections. Chiller Extra kW 35.2 294 90 3,28 A 50,6 15 Custom Unit size Cooling capacity (A35; W7) Total absorbed power EER Efficiency class Water flow (A35; W7) Pressure drop (A35; W7) kW 33.2 264 80 3,31 A 45,4 26 Basic Unit size Cooling capacity (A35; W7) Total absorbed power EER Efficiency class Water flow (A35; W7) Pressure drop (A35; W7) fc fc fc TFT: total freecooling temperature t f t. * eer * up to 3 . 3 4C up to TFT: total freecooling temperature * External air temperature 30°C; Inlet outle water temperature 10-15°C; Glycol 30% Blue Box applied product range find outthe complete product range on our web site and catalogues Zeta Echos > 40÷140 kW Beta Echos > 40÷301 kW High efficiency air cooled chillers and heat pumps. Tetris series > 84÷913 kW High efficiency air cooled modular chillers and heat pumps. Tetris W series > 32÷615 kW High efficiency water cooled chillers and heat pumps with integrated hydronic module. . Omega V Echos series > 143÷1569 kW High efficiency water cooled chillers. Omicron S Evo > 31÷226 kW Air cooled multifunctional units for indipendet production of domestic hot water, heating and cooling. Omicron V Evo > 230÷773 kW Air cooled multifunctional units for indipendet production of domestic hot water, heating and cooling. Blue Box Group S.r.l. Via Valletta, 5 - 30010 Cantarana di Cona, (VE) Italy www.bluebox.it - [email protected] Phone +39 0426 921111 - Fax +39 0426 302222
© Copyright 2024