RTU560 product line Rack 560SFR02 Data sheet Application The 560SFR02 rack is designed to be used with or without redundant power supply. Therefore, it has 2 slots for redundant power supply units (PSU). Up to 18 slots can be used for I/O boards, communication units (CMU) or a mixture of both. It is interfaced to other racks via the RTU560 serial peripheral bus. Up to 7 560SFR02 racks can be connected to an I/O bus segment. By using the bus connection unit 560BCU05, the 560SFR02 becomes a rack with up to 8 communication units (560CMU05/ 560CMU02). Also for some functions the usage of 560BCU05 is required, even if only one CMU is inserted It is installed in a swing frame cabinet or in a frame. Characteristics The 19“ rack has a height of 3 HE for single Euro-card format boards (DIN 41494). There are 20 slots available for the installation of boards. Each power supply unit has a predefined slot allocated to it (slot 21 and slot 19). A second redundant PSU must be operated in slots 18 and 19. These slots can be used only with PSU modules. Slot 1 to 17 can be used for I/O modules and/or CMU modules. If no redundant power supply is used, slot 18 can be used for an additional I/O module. Allocation of the slots: Two slots for: – 1 or 2 power supply units (each 2 slots wide) 17 slots for: – Up to 8 communication units – Up to 17 I/O modules (with redundant power supply) – Up to 18 I/O modules (if only one PSU is used) For the physical interfacing of boards edge connectors of type F (DIN 41612) are used. Rows 2 to 20 of the edge connectors connect the RTU560 system bus and are soldered directly to the printed circuit board. The connection of the process signals is done via the rows 22 to 32 by means of sub-connectors. The sub-connector is clipped into a cut-out in the edge connector (see Fig. 1). The connection of the signal wires is made by means of crimp clips using snap-in fixing. In addition to the use of prefabricated cables it is also possible to attach individual wires during commissioning. DIN-F connector with cut-out for row 22-32 Sub-connector Figure 1: Connector design This interface technology minimizes the number of cable connectors as well as the space required in the rack 560SFR02. A monitoring circuit on the rack 560SFR02 checks the supply voltages of the board (24 V DC, 5 V DC). Supply voltage failure is indicated by a status relay contact. Besides to the process signal connections, the following interface possibilities are located on the rear side of the printed circuit board: – Interface to the serial peripheral bus – Status relay contact for monitoring the internal voltages (24 V DC and 5 V DC) and status of PSU´s. – Interface and supply power for the 560BCU05 132.8 mm (5.2") 560PSU02 23BE23 23BA20 560PSU02 24 V 24 V 5V 5V ST UE- UE- PE PE ST 560CMU05 ERR ERR OFF 1 2 3 UE + UE + ST PST 560CMU05 23AE23 ON ON OFF OFF 4 1 9 2 3 10 11 E1 E1 4 5 12 13 6 14 E2 E2 7 15 8 16 CO A 1 A 1 B 2 B 2 482.6 mm (19") Figure 2: Configuration example (Redundant power supply, four 560CMU05, three I/Os) 24 V 0V X16 X2 X1 Rack No X15 X14 X13 X12 X11 24V 5V 0V 1 1 Cut-out for process connections PE PE Figure 3: Rear view (Backplane) RJ45 Backplane Process Connector Figure 4: Side view 2 | 1KGT 150 731 V004 1 - Rack 560SFR02 Technical data Power supply 5V, 24V monitoring In addition to the RTU500 series general technical data, the following applies: X11, X12 Plug-in terminal strip, 2-pole each Relay contact Normal closed contact 1 A / 60 V DC / 30 W Rack 19“, 3 HE, 20 slots according DIN 41494 1 slot = 20.32 mm Dimensions 132,8 x 482,6 x 210 mm (H x W x D) With boards 232 mm (D) With boards and 280 mm (D) connector Weight 2.6 kg Protection Earth PE 2 * Fasten 6,3 mm Environmental conditions Nominal operating temperature range: -25°C... 70°C Start up: -40 °C Max. operating temperature, max. +85 °C 96h: Printed circuit board Dimensions EN 60068-2-1, -2-2, -2-14 433,7 x 132,8 mm Relative humidity 5 ... 95 % (W x H) EN 60068-2-30 (non condensing) Ordering information Type of connection Peripheral boards 560SFR02 R0001 1KGT022200R0001 Indirect, 48 pole, Type F DIN 41612 with cut-out for sub-connector Process signal 18 pole sub-connector with crimp connection clips 23XS40R1001 23XS40R2001 Accessories Ordering information 560BCU05R0001 1KGT 022400 R0001 Bus Connection Unit (Basic) 560BCU05R0002 1KGT 022400 R0002 Bus Connection Unit (Extension) 23XS40R1001 Serial Interfaces SPB (X1, X2) 1KGN 000758 R1001 Process-connector-housing 2 *. RJ45-jack 23XS40R2001 1KGN 000758 R2001 Snap-in contacts Compliances EMC EN550011, EN61000 Environmental EN60255, IEC60870 Safety EN60950 Monitoring Connections Redundant power supply monitoring X13, X14, X15 Plug-in terminal strip, 2-pole each Relay contact Normal closed contact 1 A / 60 V DC / 30 W Rack 560SFR02 - 1KGT 150 731 V004 1 | 3 ABB AG Power Systems Division P.O. Box 10 03 51 68128 Mannheim, Germany Note: The specifications, data, design or other information contained in this document (the “Brochure”) - together: the “Information” - shall only be for information purposes and shall in no respect be binding. The Brochure does not claim to be exhaustive. Technical data in the Information are only approximate figures. We re- www.abb.com/substationautomation serve the right at any time to make technical changes or modify the contents of this document without prior notice. The user shall be solely responsible for the use of any application example or information described within this document. The described examples and solutions are examples only and do not represent any comprehensive or complete solution. The user shall determine at its sole discretion, or as the case may be, customize, program or add value to the ABB products including software by creating solutions for the end customer and to assess whether and to what extent the products are suitable and need to be adjusted or customized. This product is designed to be connected to and to communicate information and data via a network interface. It is the users sole responsibility to provide and continuously ensure a secure connection between the product and users or end customers network or any other network (as the case may be). The user shall establish and maintain any appropriate measures (such as but not limited to the installation of firewalls, application of authentication measures, encryption of data, installation of anti-virus programs, etc) to protect the product, the network, its system and the interface against any kind of security breaches, unauthorized access, interference, intrusion, leakage and/or theft of data or information. ABB AG is not liable for any damages and/or losses related to such security breaches, any unauthorized access, interference, intrusion, leakage and/or theft of data or information. ABB AG shall be under no warranty whatsoever whether express or implied and assumes no responsibility for the information contained in this document or for any errors that may appear in this document. ABB AG's liability under or in connection with this Brochure or the files included within the Brochure, irrespective of the legal ground towards any person or entity, to which the Brochure has been made available, in view of any damages including costs or losses shall be excluded. In particular ABB AG shall in no event be liable for any indirect, consequential or special damages, such as – but not limited to – loss of profit, loss of production, loss of revenue, loss of data, loss of use, loss of earnings, cost of capital or cost connected with an interruption of business or operation, third party claims. The exclusion of liability shall not apply in the case of intention or gross negligence. The present declaration shall be governed by and construed in accordance with the laws of Switzerland under exclusion of its conflict of laws rules and of the Vienna Convention on the International Sale of Goods (CISG). ABB AG reserves all rights in particular copyrights and other intellectual property rights. Any reproduction, disclosure to third parties or utilization of its contents in whole or in part - is not permitted without the prior written consent of ABB AG. © Copyright ABB 2014 All rights reserved 4 | 1KGT 150 731 V004 1 - Rack 560SFR02
© Copyright 2024