ABX MICROS CRP

22/10/04
14:21
M I C R O S
Parameters
Reagents
Page 1
C R P :
T E C H N I C A L
• CBC/DIFF mode:
18 parameters with graphics for
RBC, PLT and WBC populations.
RBC, WBC, PLT, HGB, HCT,
MCV, MCH, MCHC, PCT, MPV,
PDW, RDW,
Lymphocytes (% and #),
Monocytes (% and #),
Granulocytes (% and #).
• CBC/DIFF + CRP mode:
19 parameters with graphics for
RBC, PLT and WBC populations.
RBC, WBC, PLT, HGB, HCT,
MCV, MCH, MCHC, PCT, MPV,
PDW, RDW,
Lymphocytes (% and #),
Monocytes (% and #),
Granulocytes (% and #), CRP.
Memory
• Last result.
Sampling
• CBC/DIFF mode:
only 10 µL of whole blood.
• CBC/DIFF + CRP mode:
only 18 µL of whole blood.
Calibration
• Automatic.
Throughput
• 70 s (CBC/DIFF mode).
• 260 s (CBC/DIFF+CRP mode).
Maintenance
• Programmable start-up and
automatic cleaning cycles.
Identification
• Numerical keyboard.
Printer
• 80 column dot matrix printer
or thermal printer.
• CBC/DIFF mode: Three reagents
(diluent, lysing, cleaner).
• CBC/DIFF + CRP mode: Six types
of reagents (diluent, lysing, cleaner,
CRP reagents).
Flags
• Programmable normal limits.
• Pathological flags.
Interfacing
• RS232 output.
Functions
• By direct function-keys.
Dimensions
Weight
• 41 x 30 x 40 (H x W x D) cm.
• 18 kg.
Result display
• Through the display unit.
Power supply
• 90 V to 240 V.
• 50 Hz to 60 Hz.
Sample
processing
• On open tube with 4 position tube
holder (QC, 500 µL, 3 or 5 mL).
Quality control
• CBC/DIFF controls (3 levels).
• CRP control (2 levels).
Principles
of measurement
Parameters
S P E C I F I C AT I O N S
• Photometry (HGB).
• Immunoturbidimetry (CRP).
Within-run precision (CV )
Linearity range
Carry-over
WBC
2.5 % at 10.109/L
0.5 to 80.109/L
0.5 %
RBC
2 % at 5.1012/L
0.2 to 7.5.1012/L
0.5 %
Hgb
1.6 % at 15 g/dL
2.5 to 23 g/dL
0.5 %
PLT
5 % at 300.109/L
10 to 1 000.109/L
0.5 %
Hct
2 % at 45 %
11.6 to 55 %
0.5 %
Lymphocytes
5 % at 40 %
Monocytes
10 % at 10 %
Granulocytes
3 % at 50 %
0.2 to 7 mg/dL
0.1 %
CRP
10 % at 1 mg/dL
4% at 5 mg/dL
ABX MICROS CRP
T H E
HAN249C / Subject to technical modifications
0410185CRPGB
Compact and
fully automated,
MICROS CRP
provides fast
accurate results,
including
differential
screening and
CRP level
measurement
HORIBA ABX INTERNATIONAL (33 / 4 67 14 15 16) - HORIBA ABX - FRANCE (33 / 4 67 14 15 15) - HORIBA ABX - BENELUX (32 / 3 281 49 08) - HORIBA ABX - ITALY (39 / 06 51 59 22 1)
HORIBA ABX - SPAIN (34 / 91 353 3010) - HORIBA ABX - PORTUGAL (351 / 2 14 72 17 70) - HORIBA ABX - U.K. (44 / 1462 8144 00) - HORIBA ABX - AUSTRIA (43 / 1 718 78 44 00)
HORIBA ABX - POLAND (48 / 22 673 20 22) - HORIBA ABX - USA (1 / 949 453 0500) - HORIBA ABX - BRAZIL (55 / 11 55 45 1500) - GERMANY AXON LAB AG (49 / 7153 92260)
ABX ONLINE : http://www.horiba-abx.com
in whole blood.
P O W E R
O F
S Y N E R G Y
22/10/04
14:21
Page 2
MICROS CRP
EVERY TIME AN EMERGENCY SCREENING IS NECESSARY
COMPACT AND FULLY AUTOMATED, MICROS CRP PROVIDES FAST
Emergency labs,
Rheumatology,
ACCURATE RESULTS, INCLUDING DIFFERENTIAL SCREENING AND
Pediatrics, Surgery...
CRP LEVEL MEASUREMENT IN WHOLE BLOOD.
Fast and flexible, combining
hematology and immunology in
one single instrument, MICROS
CRP allows you a global approach:
The first analyzer
combining blood cell
count and analysis
with CRP measurement
in whole blood.
• Screening of the acute phase
reaction
• Early diagnosis of infectious and
inflammatory diseases
• Monitoring extent and activity
of disease
• Diagnostic orientation of leukocytosis and thrombocytosis cases
• Improvement of turn-aroundtime
RBC, WBC, PLT, HGB, HCT,
MCV, MCH, MCHC, PCT,
MPV, PDW, RDW,
Lymphocytes (% and #),
Monocytes (% and #),
Granulocytes (% and #)
and CRP.
Fully automatic, compact and
easy to use, MICROS CRP offers
you unique performances:
• CRP measurement in whole
blood
• Sampling on primary tube
• Differential screening
• 18 µL sampling volume
• Perfectly suitable for pediatric
samples
• Extremely quiet (no compressor)
• “zero-maintenance” concept
TIME AFTER INFLAMMATORY STIMULUS (DAYS)
3.100
CRP
3.000
300
ESR
200
100
0
0
ACCURATE RESULTS AND
DIFFERENTIAL SCREENING
FLEXIBLE AND EASY TO USE
AUTOMATIC AND COMPACT
BENCHTOP ANALYZER
• 18 hematological parameters
• Sampling on K3EDTA tubes,
• One button aspiration with
+ CRP level measurement
with 4 position tube holder
(QC, 500 µL, 3 or 5 mL)
• No pre-dilution step
• Automatic cleaning of the
sampling needle
• Impedance technology
+ immunoturbidimetry
• Sampling on whole blood
• Complete selective flagging
• Normal limits printed on
patient results
• Automatic calibration
probe wipe
• Fully-automatic analysis cycle
• One button auto/manual
start up and shut down
• Simple menu driven system
with user prompt
• Selectable daily maintenance
7
14
CHANGE IN MEASURED VALUES
0410185CRPGB
21
Characteristic patterns of change
in ESR and CRP concentration after
an inflammatory stimulus.
Following the inflammatory stimulus,
CRP concentration increases early,
five hours after the onset of acutephase reaction, with a magnitude as
much
as 1000-fold. Conversely, the ESR rate
of change, as well as its dynamic
range, is much lower than that of CRP.
CLINICAL SETTINGS ASSOCIATED WITH MAJOR ELEVATION OF
SERUM CRP CONCENTRATION
Infection: • Acute bacterial infections • Systemic fungal infections • Plasmodium (P. falciparum) infection • Systemic Pneumocystis or Toxoplasma infection
• Systemic CMV or Herpes virus infection.
Inflammatory disease: • Rheumatic fever • Rheumatoid arthritis • Juvenile chronic arthritis • Mediterranean fever • Reiter’s disease • Crohn’s disease
• Polymyalgia rheumatica • Systemic vasculitis • Psoriatic arthritis • Ankylosing
spondylitis.
Malignant neoplasia: • Multiple myeloma
• Non-Hodgkin lymphoma • Hodgkin’s disease
Necrosis:
• Waldenström’s disease
• Carcinoma, sarcoma.
• Myocardial infarction, acute pancreatitis, tumor embolization.
Trauma: • Surgery • Burns • Fractures.
Allograft rejection: • Renal transplantation.