Tender Document () - Government of Nova Scotia

TENDER FOR THE NSLC’S NORTH SYDNEY RETAIL STORE - COOL ZONE
SIGNAGE
NOVA SCOTIA LIQUOR CORPORATION
93 CHAIN LAKE DRIVE
HALIFAX, NOVA SCOTIA
NSLC REFERENCE NO: CN-64-I-14
NSLC Contact:
Email:
Stephen Bayer
Manager, Procurement & Tendering
[email protected]
1. Tender for Cool Zone Signage at the NSLC’s North Sydney Retail
Store, 125 Kings Street, North Sydney, NS, as per tender
specifications and drawings.
The NSLC North Sydney Cool Zone will be under renovation by a
General Contractor. The Contractor will coordinate all contractor
work for the signage efforts and all contact for on-site reviews or
installation must be coordinated with the Contractor.
2. The NSLC Policy is to ensure that all firms interested in becoming
government suppliers shall be given equitable access to contract
opportunities, except that consideration may be shown to Atlantic Provinces
suppliers, manufacturers and contractors whenever practical and
economically feasible to do so, consistent with The Atlantic Procurement
Agreement.
3. Tenders must be delivered to the Nova Scotia Liquor Corporation, prior to
the tender closing date of February 26, 2015 at 2:00 PM AST. Please
indicate the Reference Number on your document and/or envelope.
Mailing/Courier:
Address
Nova Scotia Liquor Corporation
Attn: Stephen Bayer
Manager, Procurement & Tendering
Reference No. CN-64-I-14
93 Chain Lake Drive
Bayers Lake Business Park
Halifax, Nova Scotia
B3S 1A3
4. The tender must be submitted in duplicate on form provided herein. These
forms must be completely filled out in ink, or typewritten with the signature
in longhand, and the completed form shall be without interlineations or
erasures. The tender must be addressed to the Nova Scotia Liquor
Corporation, at the above address.
5. Inquiries concerning the Specifications are to be directed only to the
attention of: Abigail MacEachern, Architecture 49
Email:
[email protected] Fax: (902) 429-2632 or
general inquiries to Stephen Bayer, NSLC Procurement & Tendering
Manager Email: [email protected]
6. Please submit all inquiries in writing to the above no later than three (3)
business days prior to the closing date. All NSLC responses will be provided
via an addendum to this tender. Confirmation of issued addenda can be
obtained by checking the tender document as posted on the Public
Tenders website at www.gov.ns.ca/tenders.
7. Notification of successful bidder and the return of Certified Cheques or Bid
Bonds will be forwarded to all unsuccessful suppliers immediately after the
tender is awarded.
8. Late quotes received after the closing date and time will be disqualified from
competition and returned to the bidder unopened.
9. Tenders will not be accepted by fax or email.
10.Incomplete tender and tenders that fail to comply with the specification
documents will be rejected. Contractors are urged to (1) indicate all areas
with which they will not comply and (2) specific terms which they will accept.
Rationale for their position will also enhance their proposal.
11.Changes/amendments to Bid Submissions may be accepted by fax
provided the attached NSLC document is completed. Fax must include
proper identification by company name, reference number and due date and
are received prior to closing date and time. Amendment is to identify change
in price only, not revealing the amount of the original bid submitted.
a. For example your Amendment must state:
b. Change (decrease/or increase) to the original bid excluding HST is
$10,000.00. Do not show any HST as this is no longer required.
c. Please use form provided.
12.Bidder should ensure that all calculations and totals are correct. If any
discrepancies/errors are noted in the evaluation process, the unit price will
prevail.
13.Bidder’s expenses for this tender are the sole responsibility of the bidder in
the preparation or presentation of their proposal.
14.The NSLC reserves the right to reject any or all bids. This tender implies no
obligation on the NSLC to accept this bid or any bid submitted and has the
right to cancel this tender if required.
15.The NSLC reserves the right to cancel the awarded contract with 30 days
written notice if required.
16.All contracts resulting from this tender will be governed under the laws of
Nova Scotia.
17.Tenders shall cover the execution of the whole of the work described in the
specifications.
18.The NSLC reserves the right to contact bidders for the purpose of clarifying
information included in the proposal prior to making a final decision or
recommendation.
19.The successful Bidder shall enter into an agreement using NSLC Work Order
or C.C.D.C. Document 2. within three (3) days of the opening of the tender
to be supplied by the Bidder unless otherwise agreed upon. The security
deposit herein called for shall be forfeited should the Contractor fail to sign
the contract within three (3) days.
20.If work is either directly or indirectly delayed or stopped for a period which in
the opinion of the NSLC, acting reasonably, is likely to continue so as to
substantially prevent, hinder or delay the timely completion of the contract
and such delay or stoppage is caused;
a. by fire, flood, elements of nature or acts of God;
b. by acts of war, terrorism, riots, civil disorders or reasonable apprehension of
such;
c. by labour disputes, strikes, or lock outs;
d. under an order of any court, or other public authority, through no act or fault
of the contractor or anyone employed by him/her; or
e. by other similar cause beyond the reasonable control of either party (but not
including financial difficulties or insolvency;
and such delay could not have been prevented by reasonable precautions
and could not be circumvented by the non-performing party through the use
of alternate sources, work around plans or other means, either party may,
upon providing three days’ notice to the other, terminate the contract. In
such case, the contractor may recover from the Corporation payment for all
work executed and reasonable profit for that work.
21.The Bidder shall include in his
shall act as sub-contractors for
subject to the approval of the
contractors after the signing
received from the NSLC.
tender a list of all firms which it is intended
portions of the work. All sub-contractors are
NSLC, and there shall be no change of subof the contract unless written approval is
22.Each tender shall be accompanied by a Certified Cheque payable without
recourse to the Nova Scotia Liquor Corporation or by Bid Bond, for not
less than ten percent (10%) of the amount of the Tender, covering the
faithful performance of the contract and payment of all obligations arising
from the contract. The certified cheque or bond of the successful bidder shall
be returned upon receipt of the satisfactory Performance Bond and Labour
and Materials Payment Bond as specified hereinafter in Clause 28, unless
certified cheque or bid bond is retained as performance bond. For this
reason, tenders will not be accepted by fax or email.
23.Insurance shall be placed by the Contractor in accordance with the General
Conditions.
24.The contractor and all Sub-contractors shall pay fair wages, and shall pay
rates of wages and allowances to the various classes of labour not less
favorable than those prevailing in the area where the work is being
performed. The Contractor shall comply with all laws and regulations in any
way affecting those engaged or employed upon or in the conduct of the
Works. The Contractor shall protect and save harmless the Owner from and
against all claims or demands arising out of or based on the violation of any
such laws or regulations.
25.The percentage of holdback on all payments shall be 10 percent for lien
purposes. The NSLC reserves the right to withhold additional holdback
amounts for work not completed as required in the bid documents.
26.Expected completion date will be set by the signage contractor in discussion
with the General Contractor unless otherwise agreed upon.
27.The Contractor shall indicate on his tender form that he has based his prices
on the specifications and all addenda issued during this course of tendering.
He shall also assure himself that he has, in his possession at the time of
tendering, all addenda that have been issued.
28.For projects greater than $100,000 in value, the Contractor will be required
to furnish a Labour and Material Payment Bond (50%) and/or Performance
Bond (50%) which will total 100% of the Contract amount. These securities
will cover the faithful performance of the contract, including all warranty
claims after the final payment, and the payment of all obligations arising
under the Contract, in such a form as the NSLC may prescribe and with such
sureties as they may approve. All costs in the tender price, and these Bonds
are to be maintained for a period of six (6) months beyond date of
substantial completion. For projects less than $100,000.00, a cash security
of 10% may be retained as a Performance Bond.
For contractors who cannot obtain bonding, the owner, at his discretion, may
request an additional cash security of 10% of the contract amount. This
performance security of 10% will then be released progressively as the
contract reaches completion. A warranty security of 2 1/2% will be retained
for 45 days after substantial completion.
29.The Contractor must provide a Statutory Declaration, properly notarized
stating that there are no Mechanics Liens registered against the job and that
all accounts have been paid in full, before certifying final payment including
holdback monies.
30.Product
i. Where a Bid Document stipulates a particular product,
alternatives may be considered by the Owner, noting that the
Owner has a set standard in place for this work. Please
complete the details in the space provided on the Bid Form that
follows; alternates will not be accepted post tender unless
otherwise agreed upon.
ii. When a request in writing to substitute a product is made to the
Consultant, the Owner may approve the substitution as an equal
and will issue instructions in an addendum to the bidders.
Written requests for alternatives must be submitted at least
three (3) days before tender closing and must include all data
necessary to prove equivalency of proposed product to meet the
requirements of the specified product including, but not limited
to, product descriptions, performance criteria, test data,
installation instructions, standards’ certification and sample
guarantee/warranty forms.
iii. Where bidders choose to submit alternatives to products and
methods specified, the description of such alternatives shall be
entered on the Tender Form in the space provided. Please
ensure you state the costs associated to these alternatives. You
may submit as an option costing as well as the original costing
for products we are seeking in this RFP. This will provide us with
the comparative pricing.
iv. In submission of alternatives the bidders shall include in their
tender, allowances for changes required in the work to
accommodate such alternatives. Later claims by the bidders for
an addition to the Contract Price because of changes in the work
necessitated by use of alternatives shall not be considered.
31.Tenders must include the cost of all Permits and fees.
32.The NSLC will require, prior to issue of a Certificate of Total Completion, a
Certificate of Release issued by the Workmen's Compensation Board:
.1 Prior to issue of a Certificate of Total Completion, the Contractor must:
.1
.2
Have a Certificate of Recognition issued jointly by
the Workers’ Compensation Board of Nova Scotia (WCB)
and an occupational health and safety organization
approved by the WCB; or
Be in the process of qualifying for the Certificate of
Recognition from an occupational health and safety
organization approved by the WCB.
.3
Before work on the project commences, the contracted
party must have had the sponsoring occupational health
and safety organization submit a Letter of Good Standing
to the NSLC Representative.
.4
Before work on the project commences, the contracted
party must ensure that all of its employees who will be
working on the project have received appropriate training
and are competent to perform the work required.
.5
Provide coordination with the NSLC to ensure safety for
NSLC employees and customers.
33.The Contractor will not be allowed to begin work on this project until advised.
All work to be coordinated with the General Contractor on site, such award
not made yet.
34.Vendors must submit proof, prior to contract award, of their Certificate
of Recognition issued jointly by the Nova Scotia Construction Safety
Association and the Province of Nova Scotia Department of Labour, or a valid
Letter of Good Standing from an occupational health and safety organization
approved by Nova Scotia Transportation and Public Works indicating the
Contractor is in the process of qualifying for the Certificate of Recognition.
Failure to supply this certificate will result in automatic disqualification of the
tender submission.
35.The NSLC reserves the right at any time to ensure the work is being
completed to its standards as provided in the documents, and may request
quality assurance reviews for this purpose from consultants or other signage
companies.
36.The NSLC reserves the right not to award to ay bidder based on past
performance with the NSLC.
37.Pricing to remain in effect for thirty (30) days from time of award.
38.Contractors are to provide a written warranty on all materials and
workmanship for a minimum one (1) year period from the date of contract
completion.
39.Bid Evaluation Criteria
Compliance with the Bid Documents
Pass / Fail
Price
80 %
Schedule
20 %
100%
NOVA SCOTIA LIQUOR CORPORATION
BID FORM
NSLC REF NO: CN-64-I-14
COOL ZONE SIGNAGE
COOL ZONE SIGNAGE at the NSLC North Sydney Retail Store, as per tender
specifications.
SUBMITTED BY:
The undersigned Bidder agrees to provide all necessary labour, permits (if
required), equipment, tools, travel, shop drawings, site supervision, incidentals and
other means of cleaning, and any deficiency related work associated with the timely
completion of this project as specified in accordance with the Contract and agrees
to accept, therefore as payment in full, the Contract Price for North Sydney.
I hereby fully understand the requirements and specifications of the above Tender,
and herewith submit the following prices:
Total shown below must include Complete Price for Cool Zone Signage
consistent with the Bid Documents at: North Sydney. (AS PER
SPECIFICATIONS).
TOTAL (EXCLUDING HST)
$ _______________
Days required for completion of all work, including
ordering, fabrication and shipping to site (pre installation),
and installation for all Cool Zone Signage, noting award
expected on or about 2 days after tender closes.
Days
Expected number of calendar days required for the
work package on site, as included in the number of
days noted above. Note: The NSLC expects this to
be 2 days or less based on experience.
Days
ALTERNATIVE OPTION/PRODUCT(S) PROPOSED (IF APPLICABLE):
________________________________________________________________
________________________________________________________________
________________________________________________________________
_______________________________________________________________
The undersigned Bidder agrees if awarded the Contract on this Bid to commence
and complete the Work for the duration of time specified in the bid documents.
1. The Bidder agrees that he has:
.1 Carefully examined the site of the work described herein; become
familiar with local conditions and the character and the extent of the
work; carefully examined every part of the proposed Contract and
thoroughly understands its stipulations, requirements and provisions.
.2 Determined the quality and quantity of materials required;
investigated the location and determined the source of supply of the
material required; investigated labour conditions; and has arranged for
the continuous prosecution of the work herein described.
.3 Noted that the Harmonized Sales Tax is excluded from this Contact
Price.
2. The NSLC agrees to examine this Bid and in consideration, therefore, the
Bidder hereby agrees not to revoke this Bid:
.1 until some other Bidder has entered into the Contract with the NSLC
for the performance of the work and the supply of the materials specified
in the notice inviting Bids or in the Instructions to Bidders, or
.2 until ninety (90) days after the time fixed in the Instructions to Bidders
for receiving Bids has expired,
Whichever first occurs; provided, however, that the Bidder may revoke this
Bid at any time before the closing time and date as posted on the Public
Tenders website at www.gov.ns.ca/tenders.
3. The Bidder hereby agrees to be bound by the award of the Contract and if
awarded the Contract on this Bid to execute the required Contract
commencing on the stipulated date.
4. The Bidder hereby acknowledges receipt of the following addenda:
ADDENDUM NO.
DATED
NUMBER OF PAGES
5. The Bidder agrees, within two days of notification of acceptance, to enter into
a Contract between the NSLC and Contractor, and provide the contract
security specified.
The Bidder has listed below the Sub-contractors they will use for trades, reserving
the right to substitute should any sub-contractor withdraw his Tender or become
bankrupt; substitutions are subject to the NSLC’s approval.
Sub-contractor
Trade
Price
The Bidder recognizes the NSLC's right to accept any Tender, or to reject any or all
Tenders, also the NSLC's right to substitute any Sub-contractor after adjusting the
contract price with the Contractor.
The undersigned Bidder declares that this Bid is made without connection with any
other person(s) submitting Bids for the same work and is in all respects fair and
without collusion or fraud.
Dated this
Bidder’s Name
day of
, 2015
(please print)
Bidder’s Signature
Company
Address
Telephone Number
Fax Number
Email Address _______________________________________
NOVA SCOTIA LIQUOR CORPORATION
AMMENDEMENT TO BID SUBMISSION
Please fax this form to the Nova Scotia Liquor Corporation before the tender
closing date and time. Allow a minimum of 15 minutes prior to closing for
transmission time as there may be a back log and your submission may be
received after the acceptable time frame.
Fax: (902) 450-6007
Date & Time:
Company:
Re: Tender #CN-64-I-14
Number of Pages:
MESSAGE:
With reference to the above mentioned project, please adjust our sealed tender as
follows:
INCREASE BY:
$___________________ to the lump sum
OR
DECREASE BY:
$___________________ to the lump sum
No tax portion is required.
OFFICIAL SIGNATURE: ____________________________
TENDER OUTLINE
The NSLC wishes to solicit bids from qualified sign companies for the production and
installation of numerous sign related products located inside the CoolZone area at
Store #2451, 125 Kings Street, North Sydney, NS B2A 3S5
SCOPE OF WORK
A.
To manufacture and install printed graphic panels, custom frames, printed
vinyl roller blinds, cut vinyl window graphics and laser-cut letters….all
pursuant to the specifications outlined in the attached drawings.
B.
The NSLC will provide the successful signage contractor(s) with “original”
graphic and vector files. It will be the responsibility of the successful
contractor to verify all site dimensions, to identify any obstructions not
previously outlined and to resize all graphic files to fit site or product
dimensions.
C.
The successful contractor will provide to the NSLC or its Project Manager,
a complete set of shop drawings that outline the manufacturing process
being used, all appropriate dimensions and include all graphic layouts and
designs. Contractor supplied shop drawings must be submitted to the
NSLC within 7 business days from the contract award.
D.
Permits (where and if required) are the responsibility of the successful
contractor and copies must be submitted to the NSLC Project Manager
upon request.
SIGN REQUIREMENT SUMMARY – Store #2451, (125 Kings Street, North
Sydney)
Some stated sizes, total quantities and detailed item requirements do vary from location to location.
Bidders should also consult the enclosed site-specific Architectural drawings for further details and store
requirements but note that these copies are “for reference only”.
Item
Quantities
Cheers of the World
Produce and install one (1) wall-mounted display
fabricated and installed as a single unit complete
with all factory applied, laser-cut dimensional
letters
2451-11
Graphic Panels and Dimensional
Frames
Produce and install six (6) direct UV printed
composite panels and black PVC framing
2451-12
Roller Blinds
Remove five (5) 8’ and one (1) 4’ roller blind
assemblies presently installed on site. Deliver all
blinds to the NSLC for future use. Supply five (5)
new 8’ blinds as specified including the fabrication
and installation of “L” brackets and high density
foam spacers, new printed PVC blinds (files will be
supplied) and to ensure installed blinds operate
smoothly and remain level during operation. Two
blinds must be cut on site to operate around
existing condensate pipes
2451-13
Fabricate and install one (1) ACM direct-printed
display panel incorporating a painted aluminum
angle support frame. ACM panels are bonded to
aluminum structural frames and mounted to vertical
Unistrut supports using mechanical hardware and
painted aluminum mounting clips. Installation
(fastening) of the copper and stainless valance
sections for this Beer Taste Guide are part of this
tender
2451-14
Door and Window Graphics
Produce and install one (1) set of second-surface
applied etch vinyl graphics to doors and sidelight
windows at CoolZone entrance
2451-77
Stainless and Copper applied
Valance Text
Fabricate and install multiple sets of laser-cut
acrylic letters incorporating first-surface applied
vinyl, all as per supplied vector files.
2451-33
Beer Taste Guide
Drawings
2451-44
2451-55
2451-66
2451-22
2451-15
SPECIFICATIONS:
1.
Cheers of the World Dimensional Graphic Display
Reference Drawings 2451-11, 2451-44
1.1. Manufacture Display sign as per supplied drawings.
1.2. Front panel to be 3mm Aluminum Composite Material (ACM) and
produced as per the supplied drawings.
1.3. Composite panels are to be secured as per drawings with all fabrication
completed at the contractor’s production facility. One panel seam is
permitted and it must be tight, smooth and without gaps. On-site
assembly will not be permitted.
1.4. Display graphics are fabricated using 6mm “black” laser-cut acrylic and
finished with 1st surface applied 2mil cast vinyl as specified in the
drawings.
1.5. Laser-cut acrylic letters will be fastened to the ACM using automotive
grade double-sided tape (e.g. 3M Automotive Acrylic Plus).
1.6. The completed and fully assembled display will be installed above the
main entry doors as detailed. Any wall obstructions prohibiting this
specific installation location must be noted on the contractor supplied
shop drawings and be immediately brought to the attention of the NSLC.
1.7. Sign is to be securely anchored to the insulated wall material as detailed
in the attached drawings. Special attention should be made to the sign’s
location due to a lighting obstruction on site.
2.
Perimeter Graphic Panels with Custom Moldings
Reference Drawings 2451-12, 2451-55
2.1. Manufacture six (6) graphic panels and frames as per supplied drawings,
specifications and print files.
2.2. Contractor is responsible to setup supplied graphic files for their brand of
“direct printer” and to colour-manage the supplied artwork to ensure all
printed colours match the hard copy sample provided with the files.
2.3. Graphics are direct UV printed on the matte side of factory-finished white
3mm ACM. Printed and laminated vinyl graphics are not considered an
accepted alternate for this application.
2.4. Each panel will be displayed inside a custom molding incorporating
beveled edges and mitered corners as detailed. All exposed edges are
sanded smooth (to remove any fabrication markings) before assembly.
2.5. Panels are fastened to the insulated walls using the two-part “cleat”
system as detailed. Any wall obstruction requiring either a location or
possible fastening change must be identified during the contractor’s site
check and be noted on their submitted shop drawings. Where an
obstruction does exist, the contractor will recommend to the NSLC Project
Manager, the most reasonable solution to correct or remedy the situation
and note such solutions within their shop drawings
2.6. Side panel installation locations are directly above the NSLC’s perimeter
shelving. Contractors should be aware that either a scissor-lift or other
such safety device may be required for this installation. Individuals will
not be permitted to either stand on or temporally relocate any shelving to
facilitate a standard ladder-assisted installation.
3.
Roller Blinds with Graphics
Reference Drawings 2451-13, 2451-66
3.1. Remove all existing roller blind assemblies from site and deliver to NSLC
Head Office for reuse.
3.2. Supply five (5) new 8’ blind assembly units (Atlantic Venetian Blinds
@902-468-7263) and to apply an aluminum 5” front panel to the face of
each unit. Prime and paint the exterior of each unit using Matthews Paint
MP52234 (Warm Copper Metallic) following the manufacturer’s guidelines
and specifications.
3.3. Setup and properly scale NSLC’s graphic images files for printing. Colour
correct the printed output to match the hard copy version supplied.
3.4. Solvent-print graphic panels (1 panel per blind) using the specified vinyl
material, trimmed as specified including side hems, and a dowel pocket at
the bottom.
3.5. Fabricate custom angle brackets and high-density foam spacers (2 sets of
each per blind) and attach all components to the existing pallet racking as
outlined.
3.6. Positional “chain stops” must be added to each blind assembly to ensure
banner material stops 12” from the top and will not be permitted to open
lower beyond the top of the middle rail. Contractor to ensure that all
blinds, when opened, are all at the same height and hang level.
3.7. Two (2) of the five blinds must roll up and down and fit around an
existing pair of condensate pipes. Blinds must be cut on site to meet this
site condition however the pocket dowel is not to be cut and will remain a
one-piece unit.
4.
Beer Taste Guide Graphic Panel and Copper Valance Text
Reference Drawings 2451-14, 2451-15, 2451-22
4.1. Manufacture the ‘Beer Taste Guide’ display and cut letters for application
to the copper valance located above the guide.
4.2. Setup the supplied graphic print file and colour-manage all artwork to
match the hard copy sample provided.
4.3. Graphics are UV printed directly to the matte factory finish side of white
3mm ACM. Printed vinyl is not considered an accepted alternate for this
application.
4.4. Fabricate aluminum angle frame with welded mitered corners and vertical
supports. Secure printed panels to the angle aluminum face using the
chemical adhesive specified. All assembly work must be completed prior
to installation as panel must be installed as a 1-piece constructed item.
The perimeter aluminum frame and all mounting clips are to be primed
and then painted (spray applied) black. Mechanical fasteners securing
the frame to mounting clips must be painted to match frame colour. ACM
and aluminum frame must be flush and square.
4.5. Upper valance (Copper) lettering is laser cut from 6mm black acrylic and
1st surface applied 2mil cast vinyl as specified.
4.6. Copper and stainless valances will be supplied by the NSLC. Installation
of both valances form part of this scope. Check attached drawings for
proposed fastening details and not selected process in contractor supplied
shop drawings
4.7. Cleaning both the copper and stainless valances to remove all fingerprints
is part of this scope.
5.
Door/Window Graphics
Reference Drawing 2451-77
5.1. Site measure visible openings of both windows and doors at Cool Zone
entrance.
5.2. Prepare supplied vector graphics to fit glazing panels as referenced in
drawing.
5.3. Plotter-cut etch material and install on second surface (Cold side of
glazing)
6.
Valance Lettering on Stainless Streel Perimeter Valances
Reference Drawing 2451-33
6.1. Manufacture Product Identification Valance Text as per supplied drawings.
6.2. All lettering to be laser cut 6mm black acrylic and finished with 1st
surface 2mil vinyl as specified.
6.3. Install letters to stainless steel valances following an NSLC supplied ‘Visio
File’ layout provided to the contractor by the NSLC. Positioning layout
shown on drawing is for “reference only”.
6.4. Final cleaning of the entire shelving valance is part of this scope.
GENERAL COMMENTS
A. Bidders are responsible to acquaint themselves with all site conditions and
possible safety issues before submitting their bids.
B. This NSLC retail location will remain open during the CoolZone renovation.
Construction site safety will be under the direction of NSLC’s General
Contractor and work must be completed in such a manner as to comply with
the General Contractor’s site safety policy.
C. Sign Contractors should make themselves aware of possible graphic panel
installation difficulties over the perimeter shelving areas.
D. Tenders must include labour, materials, permits (if required), travel, shop
drawings, site-supervision & coordination with the NSLC and any of its
reviewing agents and any deficiency related work associated with the timely
completion of this project.
E. Contractors are to provide a 2-year written warranty on all materials and
workmanship from the date of project completion and/or acceptance.
1
REFLECTED CEILING LEGEND
2
GYP
GYPSUM BOARD CEILING ASSEMBLY
EXISTING CONDENSATE PIPE
TO REMAIN. CONFIRM HEIGHT
AND LOCATION ON SITE
EXIST.
9' - 6 3/4"
A.F.F.
3
ELECTRICAL LEGEND
4
REFER TO ELECTRICAL DRAWINGS
NEW BULKHEAD
EXTENSION (PROVIDE
SEPARATE PRICE)
D1
A-502
EXISTING BULKHEAD
LINE INDICATES CHANGE
OF ELEVATION IN CEILING
TILES.
Client:
Architect:
Consultants:
ISSUED FOR TENDER
Description
Scale:
REVISIONS
01.22.2015
Date
LD
As indicated
Approved:
AM
CM
JANUARY 22, 2015
Province:
NS
NSLC NORTH SYDNEY
NORTH SYDNEY
10/02/2015 12:23:37 PM
A-104
12B-12614-00
RENOVATION
REFLECTED CEILING
PLAN
DWG No.:
Contract No.:
Project No.:
Commission No.:
Title:
City:
Project:
Date:
Checked:
Drawn:
No.
***
FO
RI
NF
OR
MA
TIO
NO
NL
Y*
**
CEILING TYPES
ACT
2' x 4' SUSPENDED ACOUSTIC
CEILING ASSEMBLY
EXIST.
11' - 6 1/4"
A.F.F.
D1 RENOVATION CEILING PLAN
© 2014 Architecture 49
S:\12B-12614-00 NSLC Cool Zones\925 North Sydney\4 Drawings\Architectural\149-12513-00 NSLC North Sydney-CENTRAL-A49-H.rvt
A
B
C
D
1/8" = 1'-0"
A-104
LEDGER - 11" x 17"
13' - 0"
2
9
3
19
20
3
D1
A-502
19
10
20
13' - 0"
22
21
9
PT2
19
NEW BULKHEAD
20
11
± 20' - 9 7/8"
1
D3
2
8
18
4
STORE u/s
ACT CEILING
11' - 11"
LEVEL 1
T/SLAB
0' - 0"
UPPER ACT CEILING
11' - 6 1/4"
LOWER ACT CEILING
9' - 6 3/4"
LEVEL 1
T/SLAB
0' - 0"
Client:
Architect:
Consultants:
ISSUED FOR TENDER
Description
Scale:
REVISIONS
01.22.2015
Date
LD
3/16" = 1'-0"
Approved:
AM
CM
JANUARY 22, 2015
NS
NSLC NORTH SYDNEY
Province:
10/02/2015 12:23:41 PM
A-201
12B-12614-00
ELEVATIONS
NORTH SYDNEY
DWG No.:
Contract No.:
Project No.:
Commission No.:
Title:
City:
Project:
Date:
Checked:
Drawn:
No.
***
FO
RI
NF
OR
MA
TIO
NO
NL
Y*
**
EXISTING BULKHEAD
D1
A-502
19
B2 RETAIL - WEST WALL ELEVATION
A-103
PT1
11
10"
1
3/16" = 1'-0"
A-201
PT2
10
A-501
3' - 7"
± 7' - 6"
MATCH EXISTING
KEYNOTES
No.
KEYNOTE
1 EXISTING BULKHEAD TO REMAIN
2 NEW REACH-IN COOLER DOORS (6 IN TOTAL)
3 EXISTING REACH-IN COOLER DOORS TO
REMAIN
4 EXISTING FLOOR RAIL TO REMAIN
5 NEW BOLLARD
6 EXISTING SLIDING DOOR TO WAREHOUSE
7 STAINLESS STEEL WALL MOUNTED TRIM
8 NEW FRAMING c/w VALANCE & LIGHTING
FIXTURES ABOVE, BY OWNER'S CONTRACTOR
9 EXISTING CEILING TO REMAIN
10 NEW SHELVING, BY OWNER'S CONTRACTOR
11 NEW DISPLAY PLATFORM. REFER TO DETAILS
12 NEW 2-TIER PALLET SHELVING c/w NEW
SIGNAGE BY OWNER
13 NEW UNI-STRUT / ROLLER RACK FRAME
ASSEMBLY BY G.C. REFER TO DETAILS
14 ROLLER RACK SIGNAGE BY OWNER'S
CONTRACTOR
15 EXISTING ROLLER RACK ASSEMBLY
16 EXISTING BOLLARD TO REMAIN
17 LINE INDICATES PAINT COLOUR TRANSITION
18 NEW BULKHEAD EXTENSION. TO MATCH
EXISTING. PROVIDE SEPARATE PRICE.
19 NEW COOL ZONE GRAPHICS. BY OWNER'S
CONTRACTOR
20 EXISTING EXIT SIGNS , ELECTRICAL CONDUITS,
EMERGENCY LIGHTS TO BE RELOCATED AS
REQUIRED. COORDINATE WITH ELECTRICAL.
21 HATCH INDICATES NEW GYPSUM WALL AND
PAINT TO MATCH EXISTING
22 REMOVE EXISTING STAINLESS STEEL FINISH,
AND PROVIDE NEW CONT. STAINLESS STEEL
FOR ENTIRE BULKHEAD. PROVIDE SEPARATE
PRICE.
7
8
3/16" = 1'-0"
A-103
D2 COOL ZONE - EAST WALL ELEVATION
A-201
© 2014 Architecture 49
S:\12B-12614-00 NSLC Cool Zones\925 North Sydney\4 Drawings\Architectural\149-12513-00 NSLC North Sydney-CENTRAL-A49-H.rvt
A
B
C
D
LEDGER - 11" x 17"
7' - 6"
1
18' - 6"
9
12
2
EXISTING CONDENSATE PIPE
TO REMAIN. CONFIRM HEIGHT
AND LOCATION ON SITE
17
4
w. MANAGER
A-202
7
9
PT1
PT2
D2 COOL ZONE - WEST WALL ELEVATION
3
12
7
4' - 4"
7
4
UPPER ACT CEILING
11' - 6 1/4"
LEVEL 1
T/SLAB
0' - 0"
LOWER ACT CEILING
9' 6 3/4"
2
8
10
UPPER ACT CEILING
11' - 6 1/4"
UPPER ACT CEILING
9' - 6 3/4"
LEVEL 1
T/SLAB
0' - 0"
Client:
Architect:
Consultants:
ISSUED FOR TENDER
Description
Scale:
REVISIONS
01.22.2015
Date
LD
3/16" = 1'-0"
Approved:
AM
CM
JANUARY 22, 2015
NS
NSLC NORTH SYDNEY
Province:
10/02/2015 12:23:42 PM
A-202
12B-12614-00
ELEVATIONS
NORTH SYDNEY
DWG No.:
Contract No.:
Project No.:
Commission No.:
Title:
City:
Project:
Date:
Checked:
Drawn:
No.
***
FO
RI
NF
OR
MA
TIO
NO
NL
Y*
**
D1
PT1
14
13
15
PT2
4' - 6"
6' - 6" CONFIRM
B1 COOL ZONE - NORTH WALL ELEVATION
11' - 0"
A-503
7
KEYNOTES
3/16" = 1'-0"
3/16" = 1'-0"
A-202
© 2014 Architecture 49
S:\12B-12614-00 NSLC Cool Zones\925 North Sydney\4 Drawings\Architectural\149-12513-00 NSLC North Sydney-CENTRAL-A49-H.rvt
A
B
C
D
No.
KEYNOTE
1 EXISTING BULKHEAD TO REMAIN
2 NEW REACH-IN COOLER DOORS (6 IN TOTAL)
3 EXISTING REACH-IN COOLER DOORS TO
REMAIN
4 EXISTING FLOOR RAIL TO REMAIN
5 NEW BOLLARD
6 EXISTING SLIDING DOOR TO WAREHOUSE
7 STAINLESS STEEL WALL MOUNTED TRIM
8 NEW FRAMING c/w VALANCE & LIGHTING
FIXTURES ABOVE, BY OWNER'S CONTRACTOR
9 EXISTING CEILING TO REMAIN
10 NEW SHELVING, BY OWNER'S CONTRACTOR
11 NEW DISPLAY PLATFORM. REFER TO DETAILS
12 NEW 2-TIER PALLET SHELVING c/w NEW
SIGNAGE BY OWNER
13 NEW UNI-STRUT / ROLLER RACK FRAME
ASSEMBLY BY G.C. REFER TO DETAILS
14 ROLLER RACK SIGNAGE BY OWNER'S
CONTRACTOR
15 EXISTING ROLLER RACK ASSEMBLY
16 EXISTING BOLLARD TO REMAIN
17 LINE INDICATES PAINT COLOUR TRANSITION
18 NEW BULKHEAD EXTENSION. TO MATCH
EXISTING. PROVIDE SEPARATE PRICE.
19 NEW COOL ZONE GRAPHICS. BY OWNER'S
CONTRACTOR
20 EXISTING EXIT SIGNS , ELECTRICAL CONDUITS,
EMERGENCY LIGHTS TO BE RELOCATED AS
REQUIRED. COORDINATE WITH ELECTRICAL.
21 HATCH INDICATES NEW GYPSUM WALL AND
PAINT TO MATCH EXISTING
22 REMOVE EXISTING STAINLESS STEEL FINISH,
AND PROVIDE NEW CONT. STAINLESS STEEL
FOR ENTIRE BULKHEAD. PROVIDE SEPARATE
PRICE.
LEDGER - 11" x 17"
7' - 6"
7' - 6"
1
19
PT1
9
3/16" = 1'-0"
20
2
9
7
15
16
9
8
13
19
19
14
5
3
22' - 6"
14
19
D1
A-503
PT2
7
PT1
19
14
6
20
B2 COOL ZONE - CARTON FLOW RACKING STORAGE ELEVATION
A-203
19
10
7
PT2
4
UPPER ACT CEILING
11' - 6 1/4"
LOWER ACT CEILING
9' - 6 3/4"
LEVEL 1
T/SLAB
0' - 0"
UPPER ACT CEILING
11' - 6 1/4"
LOWER ACT CEILING
9' - 6 3/4"
LEVEL 1
T/SLAB
0' - 0"
Client:
Architect:
Consultants:
ISSUED FOR TENDER
Description
Scale:
REVISIONS
01.22.2015
Date
LD
3/16" = 1'-0"
Approved:
AM
CM
JANUARY 22, 2015
NS
NSLC NORTH SYDNEY
Province:
10/02/2015 12:23:43 PM
A-203
12B-12614-00
ELEVATIONS
NORTH SYDNEY
DWG No.:
Contract No.:
Project No.:
Commission No.:
Title:
City:
Project:
Date:
Checked:
Drawn:
No.
***
FO
RI
NF
OR
MA
TIO
NO
NL
Y*
**
KEYNOTES
7
No.
KEYNOTE
1 EXISTING BULKHEAD TO REMAIN
2 NEW REACH-IN COOLER DOORS (6 IN TOTAL)
3 EXISTING REACH-IN COOLER DOORS TO
REMAIN
4 EXISTING FLOOR RAIL TO REMAIN
5 NEW BOLLARD
6 EXISTING SLIDING DOOR TO WAREHOUSE
7 STAINLESS STEEL WALL MOUNTED TRIM
8 NEW FRAMING c/w VALANCE & LIGHTING
FIXTURES ABOVE, BY OWNER'S CONTRACTOR
9 EXISTING CEILING TO REMAIN
10 NEW SHELVING, BY OWNER'S CONTRACTOR
11 NEW DISPLAY PLATFORM. REFER TO DETAILS
12 NEW 2-TIER PALLET SHELVING c/w NEW
SIGNAGE BY OWNER
13 NEW UNI-STRUT / ROLLER RACK FRAME
ASSEMBLY BY G.C. REFER TO DETAILS
14 ROLLER RACK SIGNAGE BY OWNER'S
CONTRACTOR
15 EXISTING ROLLER RACK ASSEMBLY
16 EXISTING BOLLARD TO REMAIN
17 LINE INDICATES PAINT COLOUR TRANSITION
18 NEW BULKHEAD EXTENSION. TO MATCH
EXISTING. PROVIDE SEPARATE PRICE.
19 NEW COOL ZONE GRAPHICS. BY OWNER'S
CONTRACTOR
20 EXISTING EXIT SIGNS , ELECTRICAL CONDUITS,
EMERGENCY LIGHTS TO BE RELOCATED AS
REQUIRED. COORDINATE WITH ELECTRICAL.
21 HATCH INDICATES NEW GYPSUM WALL AND
PAINT TO MATCH EXISTING
22 REMOVE EXISTING STAINLESS STEEL FINISH,
AND PROVIDE NEW CONT. STAINLESS STEEL
FOR ENTIRE BULKHEAD. PROVIDE SEPARATE
PRICE.
1
8
3
10
D1 COOL ZONE - SOUTH WALL ELEVATION
A-203
© 2014 Architecture 49
S:\12B-12614-00 NSLC Cool Zones\925 North Sydney\4 Drawings\Architectural\149-12513-00 NSLC North Sydney-CENTRAL-A49-H.rvt
A
B
C
D
3/16" = 1'-0"
LEDGER - 11" x 17"
7' - 6"
7' - 6"
1
BULKHEAD FRAMING, AS REQUIRED,
SECURED TO STRUCTURE ABOVE
2
1' - 2"
3
STAINLESS STEEL WALL
TRIM
CONT. WOOD BLOCKING
AS REQUIRED
4
EXISTING WALL
CONSTRUCTION,
PATCH AND REPAIR AS
REQUIRED FOR NEW
OPENING
Consultants:
Architect:
Client:
NEW GYPSUM BOARD
FINISH AT HEAD AND
JAMBS OF OPENING,
PAINT TO MATCH
EXISTING
CONT. WOOD BLOCKING
AS REQUIRED (CUT TO
SUIT)
± 8" MATCH
EXISTING
PRE-FINISHED METAL
CLOSURE PANEL
CLEAR SILICONE
SEALANT
EXISTING COOLER
WALL PANEL
CLEAR SILICONE
SEALANT
REACH-IN COOLER DOOR
FRAME ASSEMBLY
LINE OF EXISTING WALL
BEYOND. PATCH AND
REPAIR AS REQUIRED
No.
Drawn:
Date:
01.22.2015
Date
LD
As indicated
Approved:
AM
CM
JANUARY 22, 2015
Scale:
REVISIONS
ISSUED FOR TENDER
Description
Checked:
Project:
NS
NSLC NORTH SYDNEY
Province:
10/02/2015 12:23:46 PM
A-502
12B-12614-00
DETAILS
NORTH SYDNEY
DWG No.:
Contract No.:
Project No.:
Commission No.:
Title:
City:
WOOD SHIMS
LEVEL 1
T/SLAB
0' - 0"
PATCH FLOOR FINISH AS
REQUIRED TO MATCH
EXISTING
CONT. WALL BASE,
RETURN TO MATCH
EXISTING
LINE OF WALL BEYOND
B3 REACH-IN COOLER DOOR HEAD DETAIL
REACH-IN COOLER
DOOR
1 1/2" = 1'-0"
A-502
LINE OF COOLER
PANEL BEYOND
REACH-IN COOLER DOOR
REACH-IN COOLER DOOR
FRAME ASSEMBLY
CLEAR SILICONE
SEALANT
PRE-FINISHED METAL
CLOSURE PANEL
EXISTING COOLER
WALL PANEL
***
FO
RI
NF
OR
MA
TIO
NO
NL
Y*
**
5/8" GYPSUM BOARD ON 3 5/8" STEEL STUD
BULKHEAD FRAMING, AS REQUIRED.
± 3' - 2 1/2" FRONT FACE TO
MATCH EXISTING BULKHEAD
(SEPARATE PRICE)
NOTES IN LIGHT GREY
ARE PART OF DOOR
SUPPLIERS SCOPE OF
WORK AND ARE TO BE
USED AS REFERENCE
ONLY
PROVIDE NEW CONTINUOUS 22 GA
STAINLESS STEEL BENT TO SHAPE.
WRAP AROUND CONTINUOUS 3/4"
PLYWOOD BACKUP, SECURED TO
WOOD BLOCKING TO SUIT, FOR
ENTIRE LENGTH OF BULKHEAD.
EXISTING TO BE REMOVED.
(SEPARATE PRICE)
B3
A-502
D3
A-502
CONT. WALL BASE
RETURN TO MATCH
EXISTING
10"
± 7' - 6"
EXISTING GYPSUM BOARD WALL
STAINLESS STEEL WALL TRIM
REACH-IN COOLER
SHELVING & VALANCE
c/w LIGHT FIXTURE, BY
OWNERS CONTRACTOR.
COORDINATE
ELECTRICAL
REQUIREMENTS
LINE OF COOLER PANEL
BEYOND
REACH-IN COOLER
DOORS BY OWNER'S
CONTRACTOR (GC TO
COORDINATE)
LINE OF WALL BEYOND
REACH IN COOLER
SHELVING BY OWNERS
CONTRACTOR.
EXISTING COOLER
WALL PANEL
D3 REACH-IN COOLER DOOR SILL DETAIL
A-502
© 2014 Architecture 49
S:\12B-12614-00 NSLC Cool Zones\925 North Sydney\4 Drawings\Architectural\149-12513-00 NSLC North Sydney-CENTRAL-A49-H.rvt
2"
LEVEL 1
T/SLAB
0' - 0"
1 1/2" = 1'-0"
5"
A
B
C
D
D1 REACH-IN COOLER DOORS SECTION (TP1)
A-502
LEDGER - 11" x 17"
1" = 1'-0"
CONFIRM
ON SITE
MATCH EXISTING u/s BULKHEAD, CONFIRM ON SITE
A
B
C
D
1/2" = 1'-0"
1
COPPER VALANCE
ROLLER RACK SIGNAGE
BY OWNER'S
CONTRACTOR
UNI-STRUCT FRAMING, BOLTED
TO FACE OF ROLLER RACKING,
BY OWNER'S CONTRACTOR
STAINLESS STEEL VALANCE
ROLLER RACK ASSEMBLY (N.I.C.)
1 5/8" x 1 5/8" UNI-STRUCT
FRAMING, BOLTED TO FLOOR
B3
A-503
D3
A-503
2
9' - 0"
COOL ZONE u/s
LOW CEILING
9'-6 3/4"
u/s COPPER
VALANCE
8'-5"
LEVEL 1
T/SLAB
0'-0"
u/s STAINLESS
STEEL VALANCE
5'-2 1/2"
D1 SECTION DETAIL - VALANCE AT ROLLER RACKS
A-503
LEDGER - 11" x 17"
3/4"
4
WRAP COPPER VALANCE AT
ENDS TO COVER EXPOSED
PLYWOOD EDGES
CONTINUOUS 22 GA
COPPER VALANCE BENT TO
SHAPE, WRAPPED AROUND
PLYWOOD BACK-UP. G.C.
TO SUPPLY
3/4" PLYWOOD BACK-UP. G.C. TO
SUPPLY
SCREW FASTEN BACK LIPS OF
STAINLESS STEEL SECURELY TO
PLYWOOD SUPPORT BLOCKING
Client:
Architect:
Consultants:
ISSUED FOR TENDER
Description
Scale:
REVISIONS
01.22.2015
Date
LD
As indicated
Approved:
AM
CM
JANUARY 22, 2015
NS
NSLC NORTH SYDNEY
Province:
10/02/2015 12:23:46 PM
A-503
12B-12614-00
DETAILS
NORTH SYDNEY
DWG No.:
Contract No.:
Project No.:
Commission No.:
Title:
City:
Project:
Date:
Checked:
Drawn:
No.
***
FO
RI
NF
OR
MA
TIO
NO
NL
Y*
**
3
UNI-STRUT SYSTEM,
BY OWNER'S
CONTRACTOR
3/4"
SCREW FASTEN BACK LIPS OF
STAINLESS STEEL SECURELY TO
PLYWOOD SUPPORT BLOCKING
3/4" PLYWOOD BACK-UP, G.C. TO
SUPPLY
CONTINUOUS 22 GA STAINLESS
STEEL VALANCE BENT TO
SHAPE, WRAPPED AROUND
PLYWOOD BACK-UP. G.C. TO
SUPPLY
WRAP STAINLESS STEEL
VALANCE AT ENDS TO COVER
EXPOSED PLYWOOD EDGES
B3 SECTION DETAIL - COPPER VALANCE
ALUMINUM ANGLE
MOUNTING CLIPS
MECHANICALLY
FASTENED TO BACK OF
PLYWOOD AND UNISTRUT SYSTEM, BY
OWNER'S
CONTRACTOR
3" = 1'-0"
A-503
UNI-STRUT SYSTEM,
BY OWNER'S
CONTRACTOR
ALUMINUM ANGLE
MOUNTING CLIPS
MECHANICALLY
FASTENED TO UNI-STRUT
SYSTEM AND BACK OF
PLYWOOD BACK-UP, BY
OWNER'S CONTRACTOR
3" = 1'-0"
D3 SECTION DETAIL - STAINLESS STEEL VALANCE
A-503
© 2014 Architecture 49
S:\12B-12614-00 NSLC Cool Zones\925 North Sydney\4 Drawings\Architectural\149-12513-00 NSLC North Sydney-CENTRAL-A49-H.rvt
7"
7"
7"
2' - 7 1/2"
7"
5' - 2 1/2"