Electronic Lamp Control - ETA PLUS ELECTRONIC GmbH

®
ELC
Electronic Lamp Control
eta plus electronic gmbh
part of the IST METZ group, Lauterstrasse 29, D-72622 Nuertingen, Germany
tel: +49 (0)7022 60 02 813;
@: [email protected]
fax: +49 (0)7022 60 02 888
www.eta-uv.de
Stand: Sept.13
ELC® general information
The electronic lamp control units ELC®
are designed to power UV medium
pressure discharge lamps. In four
different series we offer fully integrated
electronic lamp control solutions for UV
lamps from 3 kW to 35 kW.
Various air and water based
options offer most flexible and
power system integration.
versions are designed for
applications such as BWMS,
water treatment on ships.
cooling
reliable
Special
marine
ballast
The ELC® control strategies allow easy
PLC connection via PROFIBUS, Modbus
or analog signals, and supports smart
lamp control, safety and servicing
options.
Technology:
All ELC® are based on a high
frequency resonant power converter to
precisely power the medium pressure
lamps. This topology combines highest
efficiency at lowest electromagnetic
interference. The fully insulated lamp
output allows perfect lamp matching as
well as short circuit and earth fault
resistant operation.
2/19/2015
Our MP lamps:
Our customer-specific in-house lamp
development and manufacturing permits
the optimum component match for your
UV system. Coupled with the consistent
quality strategy, we supply the
industries most reliable and efficient UV
components available on the UVmarket.
system reliability
- smart soft ignition
- highest lamp lifetime
efficiency
- low heat exhaust
- highest ambient temperature
- energy savings
step less lamp control
- dimming range 20% - 100%
- precisely controlled and
monitored lamp status
mains compliance
- high power factor
- low harmonic distortion
- symmetric load
- no inrush current
- no start-up over-current
safety features
- insulated lamp output
- integrated earth fault detection
- short circuit proof
ELC® is a registered trademark of IST Metz GmbH
2
ELC® series
ELC® X series
• lamp power: 6 kW, 8 kW, 4kW, 12kW*
• Modbus and PROFIBUS control
• wide input voltage range 360 V to 528 V
• lowest harmonic distortion THDi
• protection IP 66
• integrated heat exchange
• X_B series option for marine applications
ELC® P series
• nominal lamp power: 5 kW to 35 kW
• PROFIBUS control
• highest efficiency
• protection IP 20
• air cooled
ELC® N series
• nominal lamp power: 4 kW to 32 kW
• analog / digital PLC control port
• highest efficiency
• protection IP 20
• air cooled
ELC® IP series
• nominal lamp power: 5 kW to 10 kW
2/19/2015
• field bus (PROFIBUS) control
• protection IP 65
• water cooled
* 12kW under development
3
ELC® X series
The result of intense in-house R&D
and market experience; The X series
combines ideal mains compatibility
with a highly innovative cooling
principle for best reliability and
maximum installation flexibility. The
field bus allows smart control and infield diagnostics.
Type
Lamp power
Lamp voltage
Dimensions see
ELC X4-40
4 kW
400 V
Appendix A
ELC X6-60
6 kW
600 V
Appendix A
ELC X8-80
8 kW
800 V
Appendix A
ELC X12-110*
12 kW
1100 V
Appendix A
2/19/2015
* under development
mains voltage
wide input range 360V - 528V, 2 phase
power factor
typ. 0.98
efficiency
typ. 94%
harmonic current distortion THDi
< 10%
control port
PROFIBUS and Modbus
safety interrupt
built-in safety relay for emergency stop
lamp dimming range
16% to 100%*
lamp monitoring
voltage, current, power, status
earth fault detection
standard
max. distance to lamp
40m (standard), (100m with special lamp cable)*
protection
IP66
max. ambient temperature
45 °C (X_B series 55°C)
cooling
forced air cooling, no air filter required
dimensions
470mm x 125 mm (w x h)
depth: X4: 260mm, X6: 320mm, X8: 420mm, X12: 420mm
weight
X6: 14 kg, X8: 19 kg *
approvals
CE, EN 50 178, (UL and IMO under development)*
special feature
stacking option allows cabinet-free installation of up to 12
modules in one tower
* preliminary data, subject to technical alterations, data may vary over types
4
ELC® X_B series
For marine applications like
BWMS; This version of
ELC X series is designed
in compliance with
IMO MEPC174(58) regulation.
Type
Lamp power
Lamp voltage
Dimensions see
ELC X4B-40*
4 kW
400 V
Appendix A
ELC X6B-60
6 kW
600 V
Appendix A
ELC X8B-80
8 kW
800 V
Appendix A
ELC X12B-110*
12 kW
1100 V
Appendix A
* under development
max. temperature 55°C
vibration proof
humidity proof (IP66 rated design)
built-in heat exchange
included harmonic filter optimized for generator supply
wide supply input 360 to 528 V, fully covers 440V ±20%
2/19/2015
advanced lamp ignition for low temperatures
lamp distance up to 100m
highest power density
designed according to MEPC174(58)
5
subject to technical alterations, data may vary over types
ELC® P series
Based on the N series, the P series
offers a smart digital field bus
control combined with highest power
density in a compact and efficient
design. The field bus control enables
in-field diagnostics, and significantly
reduces wiring.
Type
400 V version
Type
480 V version
Lamp
power
Lamp
voltage
Dimensions
see
ELC P5HV-400-40
ELC P5HV-480-40
5 kW
400V
Appendix D
ELC P10-400-80
ELC P10-480-80*
10 kW
800V
Appendix D
ELC PE12-400-110
on request
12 kW
1100V
Appendix B
ELC PE16-400-140
on request
16 kW
1400V
Appendix B
ELC PE22-400-220
on request
22 kW
2200V
Appendix C
ELC PE32-400-280
on request
32 kW
2800V
Appendix C
2/19/2015
* under development
mains voltage
400 V or 480 V, ± 10%, 3 phase, 50/60 Hz
power factor
P type: typ. 0.93, PE type: typ. 0.90
efficiency
P type: typ. 96%, PE type: typ. 94%
harmonic current distortion THDi
P type: 33%, PE type: typ. 36% *
control port
PROFIBUS
safety interrupt
yes
lamp dimming range
20% to 100%
lamp monitoring
voltage, current, power
earth fault detection
standard
max. distance ELC® to lamp
15 to 40m (depending on ELC type)
protection
IP20
max. ambient temperature
40 °C to 50 °C (depending on ELC type)
cooling
forced air cooling
dimensions
see table above
weight
typ. 15 kg to 37 kg
approvals
CE, EN 50 178
* PE type requires additional mains choke UK = 4%
subject to technical alterations
6
ELC® N series
A modular ELC® concept offering the
highest efficiency and process
stability for all applications. The
analog control port offers easy
connection to any PLC.
Type
400 V version
Type
480 V version
Lamp
power
Lamp
voltage
Dimensions
see
ELC N3HV-400-30
ELC N3HV-480-30
3 kW
300V
Appendix D
ELC N4HV-400-40
ELC N2x4-480-40
4 kW
400V
Appendix D
ELC N2x4-400-40
ELC N2x4-480-40
two times 4 kW
400V
Appendix D
ELC N5HV-400-40
ELC N5HV-480-40
5 kW
400V
Appendix D
ELC N6-400-75
ELC N6-480-75
6 kW
750V
Appendix D
ELC N8-400-80
ELC N8-480-80
8 kW
800V
Appendix D
ELC N10-400-80
ELC N10-480-80
10 kW
800V
Appendix D
ELC NE12-400-110
on request
12 kW
1100V
Appendix B
ELC NE16-400-140
on request
16 kW
1400V
Appendix B
ELC NE22-400-220
on request
22 kW
2200V
Appendix C
ELC NE32-400-280
on request
32 kW
2800V
Appendix C
mains voltage
400 V or 480 V, ± 10%, 3 phase, 50/60 Hz
power factor
N type: typ. 0.93, NE type: typ. 0.88
efficiency
N type: typ. 96%, NE type: typ. 94% (depending on ELC type)
harmonic current distortion THDi
N type: 33%, NE type: typ. 45% *
control port
analog 0-10V, digital I/O, PLC compatible
safety interrupt
no
lamp dimming range
20% to 100%
lamp monitoring
current, power
earth fault detection
standard
2/19/2015
max. distance
ELC®
to lamp
15 to 40m (depending on ELC type)
protection
IP20
max. ambient temperature
40 °C to 50 °c (depending on ELC type)
cooling
forced air cooling
dimensions
see table above
weight
typ. 15 kg to 37 kg
approvals
CE, EN 50 178, (UL depending on ELC type)
subject to technical alterations
* NE type requires additional mains choke UK = 4%
7
ELC® IP series
Perfectly protected water-cooled
ELC® for harsh operating conditions.
This series is controlled via
PROFIBUS, allowing smart control
and in-field diagnostics.
Type
400 V version
Type
480 V version
Lamp
power
Lamp
voltage
ELC P5IP-400-40*
ELC P5IP-480-40*
5 kW
400V
ELC P10IP-400-80
ELC P10IP-480-80*
10 kW
800V
* on request
mains voltage
400 V or 480 V, 3 phase , ± 10%, 50/60 Hz
power factor
typ. 0.93
efficiency
typ. 96%
harmonic current distortion THDi
33%
control port
PROFIBUS
safety interrupt
standard
lamp dimming range
20% to 100%
lamp monitoring
voltage, current, power
earth fault detection
standard
2/19/2015
max. distance
ELC®
to lamp
15 to 20m (depending on ELC type)
protection
IP65
max. water temperature
35 °C
cooling
water 3L / min
dimensions
approx. 540 x 130 x 235 mm (h x w x d)
weight
approx. 15 kg
approvals
CE, EN 50 178
subject to technical alterations
8
Appendix A: ELC® X series
ELC® X4
ELC® X6
2/19/2015
ELC® X8, X12
9
Appendix B: ELC® NE12, NE16, PE12 , PE16
261 mm
263,5 mm
Steckerleiste für Steuersignale
control connector
min. 150
Lufteintritt
air entrance
31 mm
650 mm
Luftaustritt
air exhaust
2/19/2015
Netzanschluß
line input
200 mm
min. 150
31 mm
501 mm
540 mm
Oben
top
Lampenstecker
lampconnection
10
Appendix C: ELC® NE22, NE32, PE22, PE32
261 mm
Steckerleiste für Steuersignale
control connector
484 mm
Lufteintritt
air entrance
min. 150
Lufteintritt
air entrance
200 mm
31 mm
650 mm
min. 150
31 mm
501 mm
540 mm
Oben
top
2/19/2015
Luftaustritt
air exhaust
Netzanschluß
line input
Luftaustritt
air exhaust
Lampenstecker
lampconnection
11
min. 20
Appendix D: ELC® N3 to N10, P5 to P10
min. 100
min. 50
pin-and-socket connector
for control signals
min. 100
473 mm
539 mm
520 mm
top
M8 (4x)
130 mm
23 mm
80 mm
Lamp feeder connection
mains connection
321 mm
Back mounting
(see manual for further info)
(see manual for further info)
2/19/2015
Side-by-side rack mounting
12