Improve Indoor Air Quality Eco DC Brushless Ventilation Fan www.sunon.com Headquarters Sunonwealth Electric Machine Industry Co., Ltd. TEL:+886-7-8135888 E-mail:[email protected] URL : www.sunon.com Sunon SAS ( Europe ) TEL:+33-1-46154515 E-mail:[email protected] 2015/03/10 (009) © 2015 SUNONWEALTH Electric Machine Industry Co., Ltd. About Sunon The world’s leading brand of DC brushless fans and blowers Founded in 1980, Sunonwealth Electric Machine Industry Co., Ltd. has always adhered to the business philosophy of “Brand, Innovation, and Value”. Step by step, it has now become a global leader in the fields of precision motors, mini fans, and thermal modules. SUNON’s concentration for more than 30 years on the research and development of core motor technology enables it to release DC Motor Technology that set the pace for the industrial trend. Today SUNON has become the best thermal solution provider for clients across various industries, such as IT, automobile electronics, optical electronics, and network communication, LED, among other industries. In 2011, SUNON’s Mighty Mini Fan accomplished NASA experiment in outer space. SUNON research center the driving engine for inventions and innovations In 2002, SUNON established its invention & innovation center in Kaohsiung, Taiwan, and assigned it the responsibility of planning, promoting, and executing the company's blueprint on innovation. Furthermore, the center was also assigned the responsibility of integrating the company’s R & D laboratories and technicians in Europe, the United States, Japan, and China to plan and build an invention & innovation team consisting of 400 professionals throughout the world and a technical services network that can respond rapidly and professionally. Based on the “Trinity R & D theory”, SUNON has been engaged in the research of motor technology Applied materials research for Development and experiments of raw materials nearly 30 years, mainly on 3 major technological fields -- “motor invention”, “motor applications”, and “total solutions for heat dissipation”-- and aims to explore the best performance and unlimited possibilities of motor applications. SUNON’s persistent pursuit of technical breakthrough and product innovation has pushed it to the forefront of technology development and enabled it to provide its clients with key modules in the three major fields of motors, cooling fans, and cooling modules to help them to accomplish their goals on next generation products. 01 SUNON Eco DC Brushless Ventilation Fan Design, simulation, Commercialization and verification of of motor applications the total solution SUNON reliability verification system SUNON has 5 reliability testing labs worldwide equipped with the topmost precision verification instruments for testing from the design phase, through pre-production, and into mass production. The complete verification system is computerized and fully automated for precise analysis of product reliability and quality satisfaction to meet the market requirements. Sound Quailty Analysis & Research Sound Quailty Lab Thermal Analysis Blade Design Magnetization Simulation Analysis SUNON production network SUNON has established its business headquarters in Kaohsiung, Taiwan and set up various branches and offices in Europe, the United States, Asia, and other places. These, together with its more than 100 distributors throughout the world and some 1000 sales & service sites, constitute a large customer service and technical support network that covers five continents of the world. In order to ensure sufficient capacity for mass produced parts, SUNON has established four professional production facilities in the following locations : Kaohsiung, Taiwan; Foshan (Guangdong), China; Kunshan (Jiangsu), China; and Beihai (Guangxi), China, Hefei (Anhui), China. Europe China / Foshan China / Kunshan Taiwan Taiwan / Taipei Japan/ Yokohama U.S.A. Research Center Research Center Research Center Research Center Research Center Research Center Research Center England Wolfeboro SUNON SAS San Jose (Paris) Beijing Wuhan SUNON INC Shanghai Shenzhen (Yokohama, Japan) (Los Angeles) Austin Taipei Headquarters (Kaohsiung, Taiwan) Kaohsiung Plant Foshan Plant Kun Shan Plant Beihai Plant Hefei Plant SUNON Eco DC Brushless Ventilation Fan 02 SUNON helps you improve indoor air pollution Today homes are built to be energy efficient for seal heat and air-conditioning cost. However, these airtight homes may actually cause health problems due to the build-up of pollutants and uncirculated stale air. It may have sealed in old, stale air, pollutants and excess moisture inside as well. And all of which you’ll breathe over and over again. In summertime, you're more likely to close doors and windows to keep the heat out and save on air-conditioning. How can you have an airtight, energy efficient home that's also healthy and well-ventilated? SUNON’s DC motor technology, features energy saving up to 60% compared to AC motor. With an ultra-low power consumption of merely 10.5W, it delivers an ultra-high air flow of 80 CFM. Save money on your electricity bills up to 60% and save the environment. 03 SUNON Eco DC Brushless Ventilation Fan Builders’ smart choice for green construction DC motor technology Long Life Harmony on Sound SUNON Eco Brushless Ventilation Fans are engineered soft start function to reduce the wear on motor bearing and prolongs the motor bearing’s life. SUNON’s sound quality analysis focuses not only the dBA but also psychoacoustic analysis. Energy Saving Energy Efficiency SUNON Eco Brushless Ventilation Fans use 60% less power than AC motor exhaust fans. SUNON Eco Brushless Ventilation Fans are among the most efficient ventilation fans available, exceeding ENERGY STAR requirements for efficiency. SUNON Ventilation Fan Marketing AC Fan (BVA080M001) Motor Type AC motor DC motor Power Rating (V/Hz) 120 / 60 120 / 60 Static Pressure (Inch-H2O) 0.1 0.1 Air Flow (CFM) 80 80 Noise (Sones) 2.0 1.2 reduce 40% Power Consumption (Watt) 26.1 10.5 reduce 60% Energy Efficiency (CFM/Watt) 3.07 7.61 * following Energy Star V3.2 need to meet 2.8 CFM/W ** following Energy Star Most efficient 2014 need to meet 7.5 CFM/W SUNON Eco DC Brushless Ventilation Fan 04 You should know-selection guide About Energy Star ENERGY STAR certified ventilation fans : • provide better efficiency and comfort with less noise. • feature high performance motors and improved ENERGY STAR : Conserv Conserve energy and blade design, providing better performance and energy expenditures. longer life. Earning the ENERGY STAR means products meet strict energy efficiency guidelines set by the US Environmental Protection Agency. Products that have earned the ENERGY STAR deliver exceptional features, while using less energy. Saving energy helps you save money on utility bills and protect our As a ENERGY STAR partner, SUNON is committed to environmental protection and strives to create products meeting standards in energy star. SUNON Eco DC Brushless Ventilation Fan features high efficiency motors and lighting that can reduce climate by helping prevent harmful carbon energy consumption by as much as 80%—all without pollution and reducing other greenhouse sacrificing performance. gases. What is HVI The Home Ventilating Institute (HVI) is an independent organization that certifies the • You are purchasing a product that has been tested and certified to meet specific industry standards. airflow and sound performance claimed by • This product will perform as claimed. manufacturers of ventilation products. HVI • When installed correctly, you will enjoy proper certification is your insurance that the air ventilation that will maximize your indoor air quality. flow (CFM rate) and noise level (sone) of • The certified air flow and noise level ratings for the our ventilation products were measured ventilation equipment you have chosen have been during rigorous testing conducted by an determined through testing by an independent independent laboratory. HVI certification is laboratory. your assurance that: SUNON has approved Regular Membership by Home Ventilating Institute (HVI). 05 SUNON Eco DC Brushless Ventilation Fan What is sone The amount of noise a fan makes is an important consideration in choosing your fan. The industry standard for measuring the amount of sound a fan makes when it operates is called “sones”. One sone is equivalent to the sound of quiet refrigerator. The lower the sone rating, the quieter the fan will be. A quiet bathroom fan will be rated at about 1.5 sones or less. What is CFM CFM is the acronym for Cubic Feet per Minute—the measure of air volume moved by the fan blower. Choose a fan with a CFM rating appropriate for your room size to ensure adequate ventilation. The right choosing for ventilation fan The American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) sets the standard for residential ventilation at a minimum of 0.35 air changes per hour, and not less than 15 cubic feet per minute (cfm) per person. (ft2) Use this simple formula or the chart to calculate Bedrooms Floor Area the required CFM for continuous ventilation. 0-1 2-3 4-5 6-7 >7 <1500 30 45 60 75 90 1501-3000 45 60 75 90 105 3001-4500 60 75 90 105 120 4501-6000 75 90 105 120 135 5001-7500 90 105 120 135 150 7.5 x (3+1) = 30 >7500 105 120 135 150 165 Add together for a total of 60 CFM CFM = .01 x floor area (in square feet) plus 7.5 x (number of bedrooms + 1). Example: A 3,000 square foot home with 3 bedrooms would require 60 cfm: .01 x 3,000 = 30 SUNON Eco DC Brushless Ventilation Fan 06 Elegant and all kinds of design. You can have a variety of choices. It’s a hidden ventilation fan! 07 SUNON Eco DC Brushless Ventilation Fan Eco DC Brushless Ventilation Fan Energy Saving up to Waterproof 60% IPX5 Ventilation Fan BVA080M001 BVA080M006 4 4 Power Rating (VAC) 110V-220V (50-60Hz) 110V-220V (50-60Hz) Noise (Sones) @0.1Ps 1.2 1.0 model Duct Dimensions (inch) Static Pressure (Inch-H2O) 0.1 0.25 0.1 0.25 Air Flow (CFM) 80 69 80 69 10.5 12.5 10.5 12.5 Power Consumption (Watts) ※ Specifications in this catalog are preliminary specification for reference. Specifications are subject to change without notice. Vantilation Fan / LED Light ‧ CT 3000~3500K, 12W LED Light model BVA080M004 BVA080M003 BVA080M007 4 4 4 Power Rating (VAC) 110V-220V (50-60Hz) 110V-220V (50-60Hz) 110V-220V (50-60Hz) Noise (Sones) @0.1Ps 1.0 1.0 1.0 Duct Dimensions (inch) Static Pressure (Inch-H2O) 0.1 0.25 0.1 0.25 0.1 0.25 Air Flow (CFM) 80 69 80 69 42 35 10.5 12.5 10.5 12.5 7 8 Power Consumption (Watts) ※ Specifications in this catalog are preliminary specification for reference. Specifications are subject to change without notice. Patent No.:ZL201320715356.4, ZL201320714973.2, ZL201330476885.9, ZL201330476884.4, ZL201330364650.0, ZL201420286641.3, ZL201420157902.1, ZL201420310661.X, D162170, D161521, D162171 SUNON Eco DC Brushless Ventilation Fan 08 Flow2 One Air Exchange System IImprove IIndoor d Ai Air Q Quality lit Low Power Consumption 4.6 W 09 Ultra-high Air Flow 3M Filter 16.36 PM2.5 CFM SUNON Eco DC Brushless Ventilation Fan Filtration Efficiency 82% Flow2 One Air Exchange System In wintertime, you're more likely to close doors and windows to keep warm air and keep the cold air out. How can you have an airtight, energy efficient home that's also healthy and well-ventilated? Flow2 One air exchange system stands for single room ventilator. It is a technology to provide fresh air into a building, extract stale air from the building. It can improve indoor air quality and you are always breathing in air that feels better. Flow2 One is similar to a balanced ventilation system, it uses the heat in the outgoing stale air to warm up the fresh air. A typical unit features two fans—one to take out household air and the other to bring in fresh air. What makes an HRV unique is the heat-exchange core. vent cap fresh air in outdoor temp. 14℉ Heat Removal Efficiency 42% Air-Conditioner stale air out 36.7℉ 14℉ 68℉ 3M PM2.5 Filter What is Heat Recovery Heat recovery is a process of continuously preheating incoming cool supply air by warming it Ø8.11 2.52 with the outgoing exhaust air. Warm air is not simply Ø3.94 exhausted but transfers most of its heat to supply air in a highly efficient heat recovery exchanger. At no time do the airstreams mix as the heat radiates through the plates of the exchanger. Benefits and Features: unit:inch Flow2 One Air Exchange System Specification Mounting Dimensions (Duct size) 4" Improve indoor air quality Power Rating (V/Hz) 110-230 (50/60Hz) Low power consumption 4.6W Speed high low Long life DC motor Power Consumption (Watts) 4.6 3.7 42% heat recovery efficiency Air Flow (CFM) 16.36 11.24 Through the wall mounted heat recovery unit Noise (dB(A)) 30.0 23.0 3M Filter PM 2.5 (Filtration Efficiency 82%) Heat Removal Efficiency (%) Efficient supply and exhaust single room ventilation 42% ※ Specifications are subject to change without notice. Product specifications are reference only. Patent No.: ZL201320621667.4, ZL201420214577.8, ZL201320627035.9, ZL201420214577.8, ZL201320627035.9 SUNON Eco DC Brushless Ventilation Fan 10
© Copyright 2024