µ-Gard® Analog Transmitter DESCRIPTION Analog transmitter for the continuous monitoring of gases and vapours in the ambient air. Used in garages, chiller rooms and heating systems, the µ-Gard MA series analog transmitter is a reliable gas detector. APPLICATION For the detection of gases within a wide range of commercial applications. MA transmitters with Pellistor or electrochemical sensor offer a linear 4 – 20 mA output signal. MA transmitters with semi-conductor sensor offer a non-linear 4 – 20 mA output signal and therefore are only suitable for connection to the Gas Controller series by MSR-E. FEATURES Continuous monitoring Easy maintenance / calibration Reverse polarity protected Overload and short-circuit protected Long life sensor Low zero point drift Poisoning stable 4 – 20 mA analog signal output (standard) 2 - 10 V analog signal (optional for Ex – please specify when ordering) Approved according to EN 61010-1; ANSI/UL 61010 1; CAN/CSA-C22.2 No. 61010-1 CONNECTING DIAGRAM MA-X_Transmitter 1 24 VDC 2 4..20 mA/2-10V DC 3 0 VDC MSR Electronic GmbH | Würdingerstr. 27a | 94060 Pocking GERMANY Tel: +49 8531-9004-0 Fax: -44 www.msr-electronic.de 1 | Oct 13 Specification subject to change without notice µGard® is a registered trademark of MSR electronic SPECIFICATIONS MA-0 CO Sensor element Response time t90 (s) Stability & resolution Repeatability (% of reading) Long term zero point drift of reading/ year Long term sensitivity drift (% reading/month) Sensor life expectancy (normal operating environment) in years Max. storage time Operating Environment Humidity non-condensing Physical characteristics Enclosure type A Flammability Enclosure color Dimensions Weight Protection class Installation Cable entry Wire connection Wire distance Output signal Analog output signal Standard: 4-20 mA Selectable: 2-10 V Guidelines Warranty MA-9 NO MA-2 NO2 MA-5 SO2 MA-2 NH3 Electrochemical, diffusion ≤ 50 ≤ 15 ≤ 45 ≤ 25 ≤ 15 ≤ 120 ±3 ppm ±3% ± 0.1 vol. % --- ± 0.2 ppm --- ± 0.2 ppm ±2% 0.2 ppm ±2% <± 20 ppm --- < 5% --< 4% /12 ≥2 < 0,2 ppm < 2% /1 ≥2 < 0,2 ppm < 2% /1 ≥2 --- --- < 0,3 ppm < 5% /12 ≥2 ≥5 < 2% /1 ≥2 MA-2 Ex MA-2 NH3 MA-3 NH3 Catalytic bead (Pellistor) ≤ 10 (Methane) ± 1% of reading --± < 6% LEL (Methane) ± < 1,5% Methane ≥3 -10 to + 50°C 5 C to + 40 °C Atmospheric ±10% ≤ 100 ≤ 50 ≤ 50 --- --- --- --- --- --- --- --- --- --- --- --- --- --- ≥5 15 – 90 % RH 15 – 95 % RH -15 to + 50°C -15 to + 50 °C 0 to + 50 °C 0 to + 50 °C Polycarbonate UL 94: V2 RAL 7032 (light grey) (W x D x H) 94 x 130 x 57 mm Approx. 0.3 kg IP 65 Wall or pillar mounting Standard 1 x M20 Screw type terminal, min. 0.25 mm2 (24 AWG) max. 2.5 mm2 (14 AWG) Max. loop resist. 500 Ω (= wire resistor + controller input resistor) Proportional, 4 – 20 mA, load ≤ 500 Ω overload and short-circuit proofed Proportional, 2 – 10 V, load ≥ 50 kΩ overload and short-circuit proofed EMC Directives 2004/108/EC EN 61010-1:2010 ANSI/UL 61010-1 CAN/CSA-C22.2 No. 61010-1 CE 12 months on material (without sensor) www.msr-electronic.de MA-3 ETO ≤ 30 Meth. --- 18 - 28 VDC (reverse polarity protected) Electrochemical sensor: 22 mA, max. 0.6 VA Pellistor/ Semiconductor sensor: 35 mA, max. 0.85 VA MSR Electronic GmbH | Würdingerstr. 27a | 94060 Pocking GERMANY Tel: +49 8531-9004-0 Fax: -44 MA-4 Ex 12 months 15 – 90 % RH -10 to + 50°C MA-4 Freon Semiconductor sensor 6 months Temperature Working temperature Storage temperature Pressure range Electrical Power supply Power consumption MA-9 O2 2 | Oct 13 Specification subject to change without notice µGard® is a registered trademark of MSR electronic --- ORDERING INFORMATION MA-X-XXXX–X–X 4 6 7 8 9 A B C D E F K L M Q F F1 A D D1 5 1 Version Factory calibration 0 – 20 ppm 5, 6 Factory calibration 0 – 50 ppm 1, 5, 8 Factory calibration 0 – 100 ppm 1 Factory calibration 0 – 150 ppm 1 Factory calibration 0 – 200 ppm 1 Factory calibration 0 – 250 ppm 1 Factory calibration 0 – 300 ppm 1, 2 Factory calibration 0 – 400 ppm 1 Factory calibration 0 – 500 ppm 1 Factory calibration 0 – 1000 ppm 1, 2 Factory calibration 20 – 2000 ppm 12, 13 Factory calibration 0 – 25 vol % 7 Factory calibration 0 – 50% LEL14 Factory calibration 0 – 100 % LEL 3 Factory calibration 30 – 300 ppm 4, 13 Enclosure Plastic enclosure (87 x 45.5 mm) IP43 Plastic enclosure (87 x 45,5 mm) IP44 Plastic enclosure (130 x 94 x 57 mm) IP65 Plastic enclosure (65 x 94 x 57 mm) IP43 Plastic enclosure (65 x 94 x 57 mm) IP54 Stainless steel enclosure 0-1110 2 2-1120 3 2-3408 4 3-1120 5 9-1129 6 2-1130 7 9-1195 8 5-1196 12 4-2070 12 4-2071 12 4-2072 12 4-2073 12 4-2074 12 4-2075 12 4-2076 13 4-2077 13 4-2078 13 4-2079 12 4-2080 13 4-2069 13 4-2068 12 4-2067 12 4-2064 3 2-3400 3 2-3480 14 4-3H55 3 4-3H80 12 3-2089 Gas* Carbon monoxide CO Ammonia NH3 Ammonia NH3 Ammonia NH3 Nitrogen monoxide NO Nitrogen dioxide NO2 Oxygen O2 Sulphur dioxide SO2 Freon R 22 Freon R 401a Freon R 401b Freon R 402a Freon R 402b Freon R 408a Freon R 409a Freon R 134a Freon R 404a Freon R 416a Freon R 407c Freon R 507 Freon R 410a Freon R 411a Freon R 123 Methane CH4 Propane C3H8 Methane CH4 Propane/ LPG C3H8 Ethylene C2H4 El.chem. sensor El.chem. sensor Pellistor sensor Semicond. sensor El.chem. sensor El.chem. sensor El.chem. sensor El.chem. sensor Semicond. sensor Semicond. sensor Semicond. sensor Semicond. sensor Semicond. sensor Semicond. sensor Semicond. sensor Semicond. sensor Semicond. sensor Semicond. sensor Semicond. sensor Semicond. sensor Semicond. sensor Semicond. sensor Semicond. sensor Pellistor sensor Pellistor sensor Semicond. sensor Semicond. sensor Semicond. sensor * The sensors partially have a cross-sensitivity to other gases due to the measuring principle. More information on request. Example: Freon Transmitter for R 134 a, plastic enclosure, factory calibration 20 – 2000 ppm Order number: MA-4-2077-F-F MSR Electronic GmbH | Würdingerstr. 27a | 94060 Pocking GERMANY Tel: +49 8531-9004-0 Fax: -44 www.msr-electronic.de 3 | Oct 13 Specification subject to change without notice µGard® is a registered trademark of MSR electronic
© Copyright 2025