ORDR-NRG Roll-In Rear-Load Multi

ORDR-NRG
Roll-In Rear-Load Multi-Deck Merchandiser with Synerg-E™
8' & 12' (Dairy)
NOTES:
 BTUH/ft notes:
 Listed BTUH/ft data represent unlighted shelves. For LED lighting, add 9 BTUH/ft to determine Total Case Lighting BTUH Load, then divide by the length
of the case to obtain a value in BTUH/ft. For T8 lighted shelves, see Hillphoenix Bluebook Appendix D for BTUH, amp and watt data.
 BTUH load increases by 132 BTUH/ft when aftermarket merchandising accessories are utilized.
 Back-up coils with a capacity of 1666 BTUH/ft at a suction temperature of 20°F must be used for each case to refrigerate the area immediately behind
the line-up to a depth of 10'. If the cooler is longer than the ORDR line-up and deeper than 10', other coils are needed to refrigerate the balance of the
cooler area. Each auxiliary coil should be centered on each case and set back a distance of 3' to 5' from the back of the ORDR. The cooler box must
have a maximum temperature of no more than 34°F.
 Listed evaporator temperature represents unlighted shelves. For lighted shelves and/or aftermarket merchandising accessories, reduce the listed evaporator
temperature by 2°F.
 Conventional Discharge Air Control – Recommended Settings: Cut-In Temp = Discharge Air + 2°F; Cut-Out Temp = Discharge Air - 2°F.
 Listed discharge air velocity represents the average velocity at the peak of defrost.
 Temperature and defrost settings listed above are recommended start-up settings. Final operational settings may need to be adjusted for the store conditions
in which the case operates.
 The recommended evaporator temperatures may need to be adjusted based on system setup, store conditions, etc. The minimum recommended evaporator
temperature is 4°F below the listed evaporator temperature.
Defrost Schedule
REVISION: 130501_0000
Defrosts per Day
1
2
3
4
All measurements are taken per ASHRAE - 72 - 2005 specifications.
Hillphoenix refrigerated display cases for sale in the United States meet or exceed Department of Energy 2012 energy efficiency requirements.
Time
12 midnight
12am - 12pm
6am - 2pm - 10pm
12am-6am-12pm-6pm
ORDR-NRG
Roll-In Rear-Load Multi-Deck Merchandiser with Synerg-E™
8' & 12' (Dairy)
REVISION: 130501_0000
ORDR-NRG
Roll-In Rear-Load Multi-Deck Merchandiser with Synerg-E™
8' & 12' (Dairy)
REVISION: 130501_0000
ORDR-NRG
Roll-In Rear-Load Multi-Deck Merchandiser with Synerg-E™
8' & 12' (Dairy)