• Indoor Units • R-410A • FTYN-D TABLE OF CONTENTS FTYN-D 1 2 Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102 Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103 Nominal capacity and power input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103 Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103 Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104 3 Dimensional drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105 4 Piping diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106 5 Wiring diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107 6 Sound data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108 Sound pressure spectrum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108 • Split Sky Air • Indoor Units 1 • Indoor Units • R-410A • FTYN-D r ADt o 0- i o 1N ld 4Y npT- R1 ISF Features 7 1 • Flat front panel: its stylish appearance blends easily within any interior décor and is more easy to clean. • Powerful mode can be selected for rapid cooling or heating • Night set mode saves energy by preventing overcooling or overheating during night time • Extremely quiet in operation • Vertical auto-swing function moves the discharge flaps up and down for efficient air distribution throughout the room • The new titanium apatite photocatalytic air purification filter increases the active surface area for effective purification and deodorisation • You have the choice out of 3 fan speeds to select • Daikin remote controls give you easy control at your fingertips. • Daikin’s special dry programme reduces humidity in the room without variation in room temperature optional (integrated titanium apatite) 2 • Split Sky Air • Indoor Units 3 steps standard • Indoor Units • R-410A • FTYN-D 2 Specifications 7 2 2-1 NOMINAL CAPACITY AND POWER INPUT For indoor units only: INDOOR UNITS NOMINAL INPUT FTYN25DV3B FTYN35DV3B Cooling kW 0.040 0.040 Heating kW 0.040 0.040 FTYN25DV3B FTYN35DV3B RYN25DV3B RYN35DV3B For combination indoor + outdoor units (air cooled): HEAT PUMP (air cooled) Cooling capacity nominal kW 2.50 3.15 Heating capacity nominal kW 3.00 3.85 Cooling nominal kW 0.83 1.20 Heating nominal kW 0.88 1.29 3.01 2.63 3.41 2.98 Nominal input EER COP Energy label Annual energy consumption Cooling B D Heating B D 415 600 Cooling kWh 2-2 TECHNICAL SPECIFICATIONS Casing Colour Dimensions Packing Unit FTYN25DV3B Height mm 330 330 Width mm 840 840 Depth mm 260 260 Height mm 273 273 Width mm 784 784 195 Depth Weight Heat Exchanger mm 195 Machine Weight kg 9.0 9.0 Gross Weight kg 11.0 11.0 mm 577 577 Dimensions Length Nr of Rows Fin Pitch mm 2 2 1.40 1.40 Nr of Passes 2 2 Nr of Stages 12 12 Tube type Fin Fan Type Air Flow Rate Cooling Heating Fan Motor Hi-XA (7) Type ML fin (Multi louver) Cross flow fan High m3/min 7.5 7.5 Medium m3/min 6.0 6.1 Low m3/min 4.6 4.9 High m3/min 7.8 7.8 Medium m3/min 6.3 6.4 Low m3/min 4.8 5.2 Quantity 1 Model Speed (cooling) Speed (heating) Fan Motor 1 18F-22 Number of steps Motor FTYN35DV3B White 3 steps, powerful and auto High rpm 1350 1350 Medium rpm 1120 1160 Low rpm 900 960 High rpm 1350 1350 Medium rpm 1120 1160 Low rpm 900 960 Output (high) W 18 18 • Split Sky Air • Indoor Units 3 • Indoor Units • R-410A • FTYN-D 2-2 TECHNICAL SPECIFICATIONS Cooling 7 2 FTYN25DV3B FTYN35DV3B Sound Power High dBA 57.0 57.0 Sound Pressure High dBA 39.0 39.0 Heating Medium dBA 33.0 34.0 Low dBA 27.0 29.0 Sound Power High dBA 57.0 57.0 Sound Pressure High dBA 39.0 39.0 Medium dBA 33.0 34.0 Low dBA 27.0 29.0 Refrigerant Type Piping connections Liquid (OD) Diameter (OD) mm 6.4 R-410A 6.4 Gas Diameter (OD) mm 9.5 9.5 Drain Diameter (OD) mm 18 18 Heat Insulation Both liquid and gas pipes Air Filter Removable/washable/Mildew proof Air direction control Left, right, up and downwards Temperature control Microcomputer control Standard Accessories Item Installation manual Quantity 1 pc Item Operation manual Quantity 1 pc Item Infrared remote control Quantity 1 pc Item Batteries Quantity 2 pcs Item Remote control holder Quantity 1 pc Item Mounting plate Quantity 1 pc Item Titanium apatite photocatalytic air purification filter Quantity 2pcs Item Screws Quantity 1 set 2-3 ELECTRICAL SPECIFICATIONS Power Supply FTYN25DV3B FTYN35DV3B Name V3 V3 Phase 1 1 50 50 Frequency Hz Voltage V 230 230 Cooling A 0.19 0.19 Heating A 0.19 0.19 Current Nominal running current (RLA) Wiring connections For Power Supply Quantity Voltage range Remark 3 3 4 for interunit wiring (included earth wiring) Minimum -10% Maximum +10% Power Supply Intake Outdoor unit only NOTES 4 1 Sound values are measured in an anechoic room. 2 Sound pressure level is a relative value, depending on the distance and acoustic environment. For more details, please refer to sound level drawings of this chapter. 3 The sound power level is an absolute value indicating the power which a sound source generates. • Split Sky Air • Indoor Units • Indoor Units • R-410A • FTYN-D 3 Dimensional drawing 7 D 3 FTYN-D Air flow (indoor) ) shows piping direction (for performance and maintenance) 30 min. REQUIRED SPACE Rear Left Right (including mounting plate) (space for performance) The mark ( 50 min. 50 min. (space for performance) (space for performance) Name plate Terminal block with earth terminal Signal receiver Room temp. thermistor Bottom Timer lamp Flaps Signal transmitter Gas pipe see note 1 (the length of pipe outside the unit: about 300) NOTES Front panel fixed screws (inside) 1 Gas pipe specification Operation lamp Model Indoor unit on/off switch FTYN25,35-- Liquid pipe 6.4 CuT (the length of pipe outside the unit: about 350) Drain hose (connecting part I.D. ø 14.0, O.D. ø 18.0) (the hose length of outside the unit is approx. 410) 9.5 CuT BLADE ANGLE Up/down (automatic) cooling, dry Wall hole for embedded piping ø 65 hole (ARC445A1) WIRELESS REMOTE CONTROLLER Heating Right/left (manual) Wall hole ø 65 hole STANDARD LOCATIONS OF WALL HOLES 3D048721 • Split Sky Air • Indoor Units 5 • Indoor Units • R-410A • FTYN-D 4 Piping diagram 7 4 FTYN-D Indoor unit Heat exchanger 4.8 CuT 7.0 CuT Thermistor on heat exch. 7.9 CuT 7.0 CuT 7.0 CuT Cross flow fan Field piping (6.4 CuT) Fan motor Field piping 9.5 CuT (9.5 CuT) Refrigerant flow Cooling Heating 4D048781 6 • Split Sky Air • Indoor Units • Indoor Units • R-410A • FTYN-D 5 Wiring diagram 7 5 FTYN-D LEGEND outdoor Signal receiver Field wiring C20 Fu1, Fu2, Fu3 H1P, H2P M1F M1S MR1-MR4 PCB1, PCB2 R1T, R2T S1-S33, X10A S1W X1M SA1 T1R V1, V2 TFU Protective earth Running capacitor Fuse Pilot lamp Fan motor Swing motor Magnetic relay Printed circuit board Thermistor Connector Operation switch Terminal strip Serge arreater Transformer Varistor Thermal fuse indoor Wireless remote controller NOTES 1 2 3 4 Size: length 60 x width 125. Refer to purchasing specification AS303002, unless otherwise specified. This drawing was drawn on CAD system. Caution: Note that operation will restart automatically if the main power supply is turned off and then back on again. 3D048079B • Split Sky Air • Indoor Units 7 • Indoor Units • R-410A • FTYN-D 6 Sound data 6-1 Sound pressure spectrum 7 6 FTYN25D Heating Octave band sound pressure level (0dB = 0.0002μbar) Octave band sound pressure level (0dB = 0.0002μbar) Cooling Approximate threshold hearing for continuous noise Approximate threshold hearing for continuous noise Octave band center frequency Octave band center frequency NOTES 4 1 2 1m Location of microphone 3 4 Measurement was taken in an anechoic room. The operation noise measuring method is in accordance with JISC9612. Operating conditions: Power source = 230 V, 50 Hz o------o H (A = 39) and o- - - -o L (A = 27) Operation noise differs with operation and ambient conditions. 1m 0.8m 3 NOTES Measurement was taken in an anechoic room. The operation noise measuring method is in accordance with JISC9612. Operating conditions: Power source = 230 V, 50 Hz o------o H (A = 39) and o- - - -o L (A = 27) Operation noise differs with operation and ambient conditions. 0.8m 1 2 Location of microphone 3D048869 FTYN35D Heating Octave band sound pressure level (0dB = 0.0002μbar) Octave band sound pressure level (0dB = 0.0002μbar) Cooling Approximate threshold hearing for continuous noise Approximate threshold hearing for continuous noise Octave band center frequency Octave band center frequency NOTES 4 1 2 1m Location of microphone 3 4 Measurement was taken in an anechoic room. The operation noise measuring method is in accordance with JISC9612. Operating conditions: Power source = 230 V, 50 Hz o------o H (A = 39) and o- - - -o L (A = 29) Operation noise differs with operation and ambient conditions. 1m 0.8m 3 NOTES Measurement was taken in an anechoic room. The operation noise measuring method is in accordance with JISC9612. Operating conditions: Power source = 230 V, 50 Hz o------o H (A = 39) and o- - - -o L (A = 29) Operation noise differs with operation and ambient conditions. 0.8m 1 2 Location of microphone 3D048870 8 • Split Sky Air • Indoor Units
© Copyright 2024