Operating Instructions Control Switch Type 07-3331-1... Control switch Explosion protection Ex protection type II 2G ex de IIC I M2 ex de I AEx de IIC; Ex de IIC T6 Class 1, Div. 2 - Class1, zone 1 Groups A, B, C, D 0044 Description This control switch has been designed to solve a great variety of problems encountered in chemical and petrochemical plants and in explosion-proofed electrical machinery. Four switch contacts as opening and closing elements in different permutations permit a large number of functions. The NC contacts have positive break operation. The switch actuator allows both latching and momentary contact with different switch positions. The control switch can be installed quickly and directly onto a mounting rail, either in double or triple ComEx enclosures or in combination with other command devices in control units. Certification PTB 99 ATEX 1043 U UL E184198 Ambient temperature -55 °C to +60 °C Approved for Zone 1 Technical data Connection Terminals 2.5 mm², fine-stranded Contact material AgSnO2 Enclosure material/manufacturing process thermoplastic/injection moulding Installation on TS 35 x 7.5 mounting rail Switch function Max. 4 switch contacts Various NC/NO contact assemblies Latching and momentary-contact functions with different switch positions Contacts Contacts with positive break operation (self-cleaning) Installation possibilities double and triple ComEx enclosures in control units Switch isolator DIN EN 60947-3 (main motor switch) Dimensions in mm P/AC-3/AC-23 A AC-3 AC-23 230 V 3ph/3 KW 1ph/2.2 KW 400 V 3ph/5.5 KW 1ph/3 KW Ie = AC-23/400 V/10 A Control switch to DIN EN 60947-5-1 (auxiliary circuit switch) AC-15 400 V 10 A AC-12 400 V 16 A DC-13 24V 1A Rated insulation voltage Ui = 690 V Ue = 400 V 01-3331-7D0001 - BARTEC Advertising Agency Rated impulse strength Vimp = 6 kV Conditional rated short-circuit current at 400 V Ie = 4 kA Short-circuit current (max. back-up fuse l.v.h.b.c) max. 16 A Nominal thermal current (+40 °C) Ithe = 16 A (+60 °C) Ithe = 11 A BARTEC GmbH Max-Eyth-Straße 16 D-97980 Bad Mergentheim Tel.: +49 7931 597-0 Fax: +49 7931 597-119 [email protected] www.bartec.de Reservation Technical data subject to change without notice. Changes, errors and misprints may not be used as a basis for any claim for damages. 1/4 Operating Instructions Control Switch Type 07-3331-1... Safety Instructions Assembly and Commissioning The control switch and the corresponding position selector switch may be used only within the specified ambient and operating temperature range. Utilisation in areas other than those specified or the alteration of the product by anyone other than the manufacturer will exempt BARTEC from liability for defects or any further liability. Incorrect installation can cause malfunctioning and the loss of explosion protection. Assembly/disassembly CAUTION Only authorised and qualified personnel may do any of the assembly, disassembly, installation and commissioning work. Install the control switch in such a way that it is mechanically protected against impact energy. Make sure the control switch to be fitted is intact (no cracks). The connection lead must meet the thermal and mechanical requirements of the area of application. The control switch may be connected and assembled only by qualified personnel who are authorised and trained to assemble electrical components in hazardous (potentially explosive) areas. Always disconnect the control switch from voltage before assembly/disassembly. The generally applicable statutory rules and other binding directives relating to workplace safety, accident prevention and environmental protection must be adhered to. The control switch may be used only if it is in a clean and undamaged condition. Dust deposits exceeding 5 mm must be removed. Marking Particularly important points in instructions are marked with a symbol: DANGER these Non-observance leads to death or serious physical injury. The necessary safety measures must be taken. CAUTION Warning of damage to property and financial and penal disadvantages (e.g. loss of guarantee rights, liability etc.). ATTENTION Important instructions and information on preventing disadvantageous behaviour. NOTE Important instructions and information on effective, economical and environmentally compatible handling. 01-3331-7D0001 - BARTEC Advertising Agency Standards conformed to Installation In hazardous areas groups I and II the control switch must be used in appropriate enclosures with “Ex e” increased safety type of protection or in an enclosure that corresponds to another approved type of protection specified in EN 60079-0 Section 1. When fitting into an enclosure with “Ex e” type of protection the clearance and creepage distances under EN 60079-7 Section 4.3, Section 4.4 and Table 1 must be observed. Only suitable tools may be used for installation. It is not permissible to modify the switch in any way. ATTENTION Avoid any capacitive influence from parallel conductors as well as any additional adverse heat effects on the conductor. The ends on fine-stranded and multi-stranded conductors must be prepared. Wire end sleeves must be crimped with suitable crimping tools. Supply cable, cross-sections: 0.75 - 2.5 mm2 (one-wire) 0.75 - 1.5 mm2 (fine-stranded, wire end ferrule) The terminals must be tightened with a maximum torque of 2.5 Nm. Commissioning Before commissioning check that: • • • Operation, Maintenance Fault Clearance and CAUTION The control switch may be used only if it is in a clean and undamaged condition. ATTENTION Only authorised and qualified personnel may do any of the maintenance and fault clearance work The operator of the control switch must keep it in good condition, operate it properly, monitor it and clean it regularly. The control switch, position selector switch and cables must be checked regularly for cracks and damage. NOTE Dirty control switches/position selector switches can be cleaned with compressed air. The control switch is defective if the switching unit does not perform switching functions any longer. Defective control switches cannot be repaired; they must be replaced. Defective position selector switches can be taken out and replaced by functioning position selectors of the same type. Accessories, Spare Parts See BARTEC catalogue also. Disposal The components in the control switch contain metal and plastic parts. Therefore the statutory requirements for electrical scrap must be observed (e.g. disposal by an approved disposal company). Service Address BARTEC GmbH Max-Eyth-Straße 16 D-97980 Bad Mergentheim Tel.: +49 7931 597-0 Fax: +49 7931 597-119 the device has been installed correctly the device is not damaged the connection has been established properly EN 60079-0:2006 EN 60079-1:2004 EN 60079-7:2007 BARTEC GmbH Max-Eyth-Straße 16 D-97980 Bad Mergentheim Tel.: +49 7931 597-0 Fax: +49 7931 597-119 [email protected] www.bartec.de Reservation Technical data subject to change without notice. Changes, errors and misprints may not be used as a basis for any claim for damages. 2/4 Operating Instructions Control Switch Type 07-3331-1... Contact arrangements in control switch Type 07-3331-1A01 Type 07-3331-1C06 13 23 33 43 0 I 0 X X X X 14 24 34 44 Type 07-3331-1A02 0 Type 07-3331-1A03 0 I 0 I II 12 24 34 44 Type 07-3331-1A04 0/I 14 24 32 42 11 23 33 43 I 0 X II 0/I X X X 12 24 34 44 12 24 34 44 Type 07-3331-1E09 11 21 31 43 0 13 23 33 43 13 23 33 43 11 21 31 43 I 0 II I 12 22 32 44 Type 07-3331-1H05 0 I X X II 0/I X X 14 24 34 44 14 24 34 44 Type 07-3331-1L01 11 23 33 43 11 23 33 43 0 X X I II X III X 12 24 34 44 II X X 14 24 32 42 11 23 33 43 11 23 33 43 X X X X 12 22 32 44 I 0 X X Type 07-3331-1E08 11 23 33 43 0 I 13 23 31 41 13 23 31 41 0 I II I 14 24 32 42 X X X X 12 24 34 44 14 24 34 44 Type 07-3331-1C07 13 23 31 41 0 I II X X 14 24 34 44 13 23 31 41 X X X X 14 24 32 42 0 I X X I 0 II I 14 24 34 44 0 I 13 23 33 43 13 23 33 43 13 23 33 43 I 13 23 33 43 0 I X X II X III IV X 14 24 34 44 II 0 III 12 24 34 44 13 23 33 43 I II III 0 IV 14 24 34 44 Contact arrangements in switch isolator Type 07-3331-1N01 Type 07-3331-1N02 1 3 5 13 1 3 5 13 0 I 1 3 5 11 2 4 6 12 1 3 5 11 0 I 0 I X X X X 2 4 6 14 4 6 14 I 01-3331-7D0001 - BARTEC Advertising Agency 2 X X X X 2 4 6 12 0 BARTEC GmbH Max-Eyth-Straße 16 D-97980 Bad Mergentheim Tel.: +49 7931 597-0 Fax: +49 7931 597-119 [email protected] www.bartec.de Reservation Technical data subject to change without notice. Changes, errors and misprints may not be used as a basis for any claim for damages. 3/4 Operating Instructions BARTEC GmbH Max-Eyth-Straße 16 D-97980 Bad Mergentheim Control Switch Type 07-3331-1... Tel.: +49 7931 597-0 Fax: +49 7931 597-119 [email protected] www.bartec.de Reservation Technical data subject to change without notice. Changes, errors and misprints may not be used as a basis for any claim for damages. 4/4
© Copyright 2024