Installation instructions Dorman Smith Loadbank 250 Q2C Outgoing Metering harnesses KITS: Meter/CT harnesses Voltage tap off (LBWPQC) - 1 per cableway Meter supply harness (DOS-QCFV-02) - 1 off per meter Current transformer harness (DOS-QCCTM-04) - 1 off per meter For each additional meter. Meter to meter harness (DOS-QCVV-01) - 1 off per additional meter Current transformer harness (DOS-QCCTM-04) - 1 off per additional meter Sheet 1 of 3 No: SN98616C REV 2 Installation instructions Dorman Smith Loadbank 250 Q2C Outgoing Metering harnesses Voltage tap off Harnesses Fig 1: • Remove busbar end shroud • Busbar end shroud Fit ‘tap off harness’ LBWPQC to busbars /neutral bar • • Meter cableways either side, tap off Fig 2: Route cables to cableway If meters mounted to one cableway only, refit busbar end shroud Fig 3: Fit ‘tap off harness’ (DOS-LBWPQC) to busbars /neutral bar • Route cables to other cableway • • Refit busbar end shroud Note! Remove looped connection block from CT • P1 markings on CTs must face source of supply CT earth connector • • CT harness • Fig 4: Secure DIN rail supplied with cableway hinged meter door kit to cableway. Earth hinged door to cableway. Earth lead to hinged door Earth lead to cableway Mount ‘tap off harness’ fuse holders on DIN rail. Connect ‘meter supply harness (DOS-QCFV-02) to the fuse holder. Route outgoing cables through CT Fig 5: • Fit DIN mounting clips to CT’s • • • Mount CT to DIN rail in line with outgoing MCCB P1 markings must face source of supply Connect ‘CT harness’ (DOSQCCTM-04 white numbered cables) to CT • • • Fig 6: Mount Ci5 meter to hinged door by removing ‘knock-out’ feature. Connect ‘meter supply harness (DOS-QCFV-02) to meter. Connect ‘CT harness’ (DOSQCCTM-04 white numbered ca- Refer to installation instruction sheet supplied with meter for set up Sheet 2 of 3 Meter supply harness Pulsed output connections (optional) No: SN98616C CT harness REV 2 Installation instructions Dorman Smith Loadbank 250 Q2C Outgoing Metering harnesses Mounting further multifunction meters Meter supply harness P1 markings on CTs must face source of supply CT harness CT earth connector Fig 7: • See Fig 5 for CT mounting. • • • Pulsed output connections (optional) CT harness Mount Ci5 meter to hinged door by removing ‘knock-out’ feature. Connect ‘meter supply harness (DOS-QCVV-01) from meter to meter. Connect ‘CT harness’ (DOSQCCTM-04 white numbered cables) to meter. Route outgoing cables through CT Refer to installation instruction sheet supplied with meter for set up Retain installation instructions for any further metering While Dorman Smith Switchgear and its affiliates referenced herein have made every reasonable effort to ensure the accuracy of the information contained in this catalogue, Dorman Smith Switchgear cannot assure that this information is error free. For this reason, Dorman Smith Switchgear does not make any representation or offer any guarantee that such information is accurate, correct, reliable or current. Dorman Smith Switchgear reserves the right to make any adjustments to the information at any time. Dorman Smith Switchgear expressly disclaims any implied warranty regarding the information contained herein, including, but not limited to, the implied warranties of merchantability or fitness for a particular purpose. Dorman Smith Switchgear only obligations are those stated in Dorman Smith Switchgear Standard Terms and Conditions of Sale. Dorman Smith Switchgear will in no case be liable for any incidental, indirect or consequential damages arising from or in connection with, including, but not limited to, the sale, resale, use or misuse of its products. Users should rely on their own judgement to evaluate the suitability of a product for a certain purpose and test each product for its intended application. Dorman Smith is a trademark. Dorman Smith Switchgear Ltd 8 Swinbourne Drive Braintree, Essex CM7 2YG Phone: +44 (0)8442251063 Fax: +44 (0)8442251063 Email: [email protected] www.dormansmithswitchgear.com Sheet 3 of 3 No: SN98616C REV 2
© Copyright 2024