Data Sheet Flow directors for aluminium segment radiators to be used with RA-N integrated valves Application The Danfoss flow director is designed to be used with integrated valves type RA-N 013G1382 for incorporation into aluminium or bi-metal segment radiators from different radiator manufactures. Aluminium and bi-metal segment radiators are constructed by a series of elements, which are joined together with nipples. The first segment is used as inlet pipe, while return is through the bottom of the second segment. When integrated valves are used with segment radiators, the flow needs to be directed correctly through the valve to avoid noise problems. This is made with the flow director. Flow director 013G1523 / 013G1524 Code Nos. and Technical Data Flow director Flow director type For aluminium/bi-metal segment radiators For aluminium/bi-metal segment radiators Connection radiator Connection integr. valve Max. water temperature Code no. 1”, RH thread ½” 120 °C 013G1523 1”, LH thread ½” 120 °C 013G1524 Max. water temp. Code no. 120 °C 013G1382 Valve for flow directors Differential pressure 1) Valve type Test pressure Work. pressure Recom. Technical For Danfoss RA 0.05-0.2 bar 0.6 bar 16 bar 10 bar type sensors 1) The technical differential pressure indicates the upper limit for a proper valve function. In most twopipe systems the recommended differential pressure is sufficient. In order to achieve a noiseless function we recommend in smaller systems to apply automatic bypass valves or automatic balancing valves. If pump differential pressure exceeds the recommended max. valve differential pressure it is recommended that an automatic balancing valve type ASV-P/PV is added to the system. Pre-setting values, flow director + valve Flow director + valve Presetting kv-value 2) 3) Flow director + RA 013G1382 int. valve Danfoss Heating Solutions VDCNA402 kvs 1 2 3 4 5 6 7 N N 0.13 0.18 0.24 0.30 0.36 0.44 0.53 0.63 0.68 © Danfoss 02/2011 1 Data Sheet Flow directors for aluminium segment radiators - to be used with RA-N integrated valves 2) kv-values indicate the flow volume (Q) in m³/h at a pressure loss (Δp) across the valve of 1 bar ; . At setting N, the kv-value in accordance with EN 215 can be stated as Xp = 2 K. At lower preset values, Xp will be reduced until approximately Xp 0.5 at presetting 1. The kvs values indicate the valve capacity, when the valve is fully open. 3) When using a liquid filled radiator thermostat e.g. RAW, RAS-D or remote setting element type RA 5060, Xp will be increased by factor 1.6 (at setting N, ref. EN 215). Accessories and Spare Parts Design and Dimensions For flow director Product Open connection nipple - to be used with flow director 013G1523 Closed connection nipple Open connection nipple - to be used with flow director 013G1524 Closed connection nipple Code no. 013G1506 013G1507 013G1548 013G1549 For RA-N 013G1382 integrated valve Gland seal Protection cap (red) 013G0290 013L0951 Flow director 013G1523 / 013G1524 10.6 77±0.75 73.7 25 Ø44 32 Ø25.3 ± 0.15 Ø11.95 12.7 1 G 1/2” ISO 228/1 3 3 2 G 1” ISO 228/1 (013G1523) G 1” ISO 228/1 LH (013G1524) Connection nipples Flat gasket 5 Ø32.4 ± 0.3 8.3 5 Ø8. 4 25 25.3 NB: Not supplied by Danfoss. 2 VDCNA402 © Danfoss 02/2011 Danfoss Heating Solutions Data Sheet Flow directors for aluminium segment radiators - to be used with RA-N integrated valves Materials 1. Plug 2. 3. 4. 5. Nickel plated steel PPS Flow director body O-ring Nipple Flat ring EPDM Steel or brass EPDM Radiator dimensions SCALE 5:1 ±5 ˚ Ø 34 ± 0.3 45˚ 1 80 ± 1 68 ± 2.5 G1” ISO 228/1 G1” ISO 228/1 LH 2 A min. 18 min. 18 Ø 0.2 A 1. Thread for reduction plug 2. Thread for assembly nipple Assembly Guide Flow director 013G1523 and open nipple (upper connection) 013G1506 is for radiators with RH thread. Closed (lower connection) nipple can be either 013G1507 or 013G1549, depending on assembly side. Flow director 013G1524 and open nipple (upper connection) 013G1548 is for radiators with LH thread. Danfoss Heating Solutions VDCNA402 © Danfoss 02/2011 3 Data Sheet Flow directors for aluminium segment radiators - to be used with RA-N integrated valves Radiator with LH thread - left side mounting Radiator with RH thread - right side mounting 1 1 2 2 3 3 4 1. 2. 3. 4. 5. 4 Open nipple 013G1548 LH thread Flow director 013G1524 Closed nipple 013G1549 Closed nipple 013G1507 VDCNA402 © Danfoss 1. 2. 3. 4. 5. 02/2011 5 4 5 Open nipple 013G1506 RH thread Flow director 013G1523 Closed nipple 013G1549 Closed nipple 013G1507 Danfoss Heating Solutions Data Sheet Capacities, Flow Director with Integrated Valve Flow directors for aluminium segment radiators - to be used with RA-N integrated valves Flow director 013G1523/013G1524 + integrated valve 013G1382 1 2 3 4 5 6 7 N 10 1 8 0.8 80 6 5 0.6 0.5 60 50 4 0.4 40 3 0.3 30 2 0.2 20 ∆p [mwg] 1 ∆p [bar] 0.1 ∆p [kPa] 10 0.8 0.08 8 0.6 0.5 0.06 0.05 6 5 0.4 0.04 4 0.3 0.03 3 0.2 0.02 0.2 0.1 0.01 5 7 10 20 30 40 50 70 100 200 100 1 2000 300 400 500 700 1000 Q [l/h] ∆ t = 10 ˚C 0.07 ∆ t = 15 ˚C 0.1 ∆ t = 20 ˚C Danfoss Heating Solutions 0.1 0.2 0.2 0.2 0.3 0.4 0.5 0.7 0.3 0.4 0.5 0.7 0.3 0.4 0.5 0.7 VDCNA402 1 2 1 1 © Danfoss 2 2 3 02/2011 3 3 4 4 5 4 5 7 5 7 10 7 10 10 20 kW 30 kW 30 40 kW 20 20 5 Data Sheet 6 Flow directors for aluminium segment radiators - to be used with RA-N integrated valves VDCNA402 © Danfoss 02/2011 Danfoss Heating Solutions Data Sheet Danfoss Heating Solutions Flow directors for aluminium segment radiators - to be used with RA-N integrated valves VDCNA402 © Danfoss 02/2011 7 Data Sheet Flow directors for aluminium segment radiators - to be used with RA-N integrated valves Danfoss A/S Heating Solutions Haarupvaenget 11 8600 Silkeborg Denmark Phone:+45 7488 8000 Fax: +45 7488 8100 Email: [email protected] www.heating.danfoss.com Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved. 8 VDCNA402 © Danfoss 02/2011 Danfoss Heating Solutions
© Copyright 2024