MAKING MODERN LIVING POSSIBLE Data Sheet H1-The new Generation of Hydrostatics 250 cm3 Bent Axis Variable Motor For more than 40 years, Danfoss has been developing state-of-the-art components and systems for mobile machinery used in off‑highway operations around the world. We have become a preferred supplier by offering the best of what really matters: The hardware inside your vehicle application. H1 - our new generation of servo-controlled hydrostatic pumps and bent axis variable motors is no exception. The H1 product is built around an advanced control and available in a wide range of displacements. It is designed for quality and reliability and offers expanded functionality, greater total efficiency, and easy installation. All H1 control and sensor options are PLUS+1® Compliant. PLUS+1® allows you to rapidly develop and customize electronic machine control. It opens up the future by combining machine controls and diagnostics in an integrated operating network. Features yy Designed for quality and reliability –– Proven and optimized 9 piston rotating group –– Single piece housing –– Electric components with IP67 & IP69K rating yy Installation and packaging benefits –– Optimized for shortest length –– Standardized connector interface –– Integrated loop flushing device –– Radial or axial high pressure ports yy Wide range of controls –– Electric Two-position Control –– Electric Proportional Control –– Hydraulic Two-position Control –– Hydraulic Proportional Control –– Pressure Compensator Override –– Proportional Pressure Compensator Override –– Brake Pressure Defeat option L1315846 • Rev BC • Oct 2014 –– Common controls across the entire motor family –– PLUS+1® Compliant control and sensor options yy Expanded functionality –– Zero degree capability together with a high performance 32 degree maximum angle –– Enhanced control functions with proportional controls de-energized at minimum or maximum displacement –– Optional integrated speed sensor with –– Dual redundant speed sensing –– Direction indication –– Temperature sensing –– Wire fault detection yy Greater total efficiency –– Minimized losses –– Improved at high flow conditions Data Sheet H1B-The new Generation of Hydrostatics 250 cm3 Motor Schematic (example) Technical specifications Electric Proportional Control Physical Properties Features Units Displacement cm3 [in3] Weight (with Electric Proportional Control) SAE ISO 3019/1 kg [lb] (de-energized = max. displacement) Size 250 250 [15.25] L2 87.7 [193] Operating Parameters Output Speed min-1 [rpm] System Pressure bar [psi] Case Pressure bar [psi] Rated Maximum at max. displacement at min. displacement (6°) at 0° displacement at max. displacement at min. displacement (6°) at 0° displacement Working Maximum Min. low loop Rated Maximum Minimum N MA A 2200 3650 4050 2800 4500 4900 450 [6527] 480 [6960] 7.5 [109] 3 [44] 5 [73] 0.3 [4] n max min C1 L1 B M4 M5 MB P003426 Installation Drawings SAE ISO 3019/1 with Electric Proportional Control (de-energized = max. displacement) Servo Pressure Gauge Port “M4” 0.5625-18UNF-2B 9/16 -18UNF-2B Speed Sensor Connector: Deutsch DTM04-6P 197 [7.76] Loop Flushing Shuttle Spool Min. Angle Stop Adjustment 387 [15.2] 65 [2.56] Solenoid Connector: Deutsch DT04-2P 15.7 [0.62] 290 [11.4] SAE ISO 3019/1 with Electric Proportional Control (de-energized = min. displacement) Loop Flushing Shuttle Spool System Pressure “A” + “B” Gauge Port ”MA” + “MB” 0.5625-18UNF-2B 9/16 -18UNF-2B Connector: Deutsch DT04-2P paint free View View X 152 [5.98] 15.7 [0.62] 260 [10.2] Y 108 [4.25] X Speed Sensor Connector: Deutsch DTM04-6P 65 65 [2.56] [2.56] Servo Pressure Gauge Port “M4” 0.5625-18UNF-2B 9/16 -18UNF-2B Y 113 [4.4] Solenoid Connector: Deutsch DT04-2P 260 [10.2] X 8x 112 [4.4] Y Min. Angle Stop Adjustment 359 [14.1] Split Flange Boss “A”+”B” DN 32 Typ I 40M Pa Series per ISO 6162 Thread: M12x1.75 23.0 [0.91] full Thread Depth 4x 20.6 [0.81] View View Loop Flushing Shuttle Spool Servo Pressure Gauge Port “M4” 0.5625-18UNF-2B 9/16 -18UNF-2B ∅165 [6.5] 267 [10.5] 152 [5.98] View 108 [4.25] 8x 112 [4.4] X SAE ISO 3019/1 with Electric Two-Position Control (de-energized = min. displacement) Pressure Compensator Override, Brake Pressure Defeat Danfoss Power Solutions (US) Company 2800 East 13th Street Ames, IA 50010, USA Phone: +1 515 239 6000 X Split Flange Boss “A”+”B” DN 32 Typ I 40M Pa Series per ISO 6162 Thread: M12x1.75 23.0 [0.91] full Thread Depth 260 [10.2] ∅165 [6.5] Min. Angle Stop Adjustment 381 [15.0] System Pressure “A” + “B” Gauge Port ”MA” + “MB” 0.5625-18UNF-2B 9/16 -18UNF-2B 65 [2.56] 4x 20.6 [0.81] Solenoid Connector: Deutsch DT04-2P Y Loop Flushing Valve 108 [4.25] Speed Sensor Connector: Deutsch DTM04-6P Loop Flushing Valve Servo Pressure Gauge Port “M4” 0.5625-18UNF-2B 9/16 -18UNF-2B 108 [4.25] 8x 112 [4.4] X 260 [10.2] 260 [10.2] System Pressure “A” + “B” Gauge Port “MA” + ”MB” 0.5625-18UNF-2B 9/16 -18UNF-2B Y ∅165 [6.5] 239 [9.41] Loop Flushing Valve 260 [10.2] 15.7 [0.62] Danfoss Power Solutions GmbH & Co. OHG Krokamp 35 D-24539 Neumünster, Germany Phone: +49 4321 871 0 4x 20.6 [0.81] Danfoss Power Solutions ApS Nordborgvej 81 DK-6430 Nordborg, Denmark Phone: +45 7488 2222 65 65 [2.56] [2.56] O108 108 [4.25] [4.25] Split Flange Boss “A”+”B” DN 32 Typ I 40M Pa Series per ISO 6162 Thread: M12x1.75 23.0 [0.91] full Thread Depth View Y P301 456E Danfoss Power Solutions Trading (Shanghai) Co., Ltd. Building #22, No. 1000 Jin Hai Rd Jin Qiao, Pudong New District Shanghai, China 201206 Phone: +86 21 3418 5200 Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved. L1315846 • Rev BC • Oct 2014 www.danfoss.com © Danfoss A/S
© Copyright 2024