MESH Gateway HDL-MCIP-RF.10 Parameters Overview Electric Parameters: Working power 12~30VDC Communication RJ45,HDL-BUS,RF Wireless transmit power +10dbm Wireless receive sensitivity -90dbm Communication distance indoor 50m (barrier free) Work mode Mesh mode, bridge mode BUS Terminal Wago 252,0.75-0.85mm Diame- HDL MCIP-RF.10 is a gateway based on IEEE802.15.4 standard ter Single Core MESH technology. Mesh Wireless Gateway has three communication interfaces: RJ45, HDL-BUS, RF, which can interconnect Wireless central frequency (China) WPAN 780MHz-786MHz different media platforms (RS485, Ethernet, RF) of HDL intelli- (Europe) SRD 864MHz-870MHz gent devices . (North America) ISM 904MHz-928MHz At the same time, this device can also be configured as transparent transmission (bridge) mode. RS485 and Ethernet data in Environmental Conditions: multiple gateways can be transmitted from RF, which effectively Working Temperature 0℃~45℃ Working relative Humidity Up to 90% Storage Temperature -20℃~+60℃ Storage relative Humidity Up to 93% extends the communication distance. In the inconvenient of layout application environment, subnets can interconnect with wireless (RF). Functions Approve: CE RoHS Production Information: ■ Can be configured as Mesh mode. ■ Can be configured as Bridge (transparent transmission) mode. Dimension 107×99.5×27(mm) Weight 103g ■ Communication data rate is higher than the cable. Important Notes Housing material ABS Installation Desk or wall mounted Protection Degree IP20 ■ Check the HDL Bus connection, avoid any mistakes ■ In MESH mode, different RF channels must be different for each gateway, each gateway manages a wireless network with same SubNet ID. In Bridge mode, RF chan- HDL-BUS Definition for Cable HDL-BUS HDL-Bus/KNX DC24V Red COM Black DATA- White DATA+ Yellow Installation Step ■ nel must be the same as each gateway. ■ the same as RF devices which is managed by the gateway, and port ID is unique in RS485 port ■ Two or more devices Ethernet (RJ45) can not be connect ed with RS485 port , otherwise loop connection will block communication ■ Must select free RF frequency for different countries, user can set new wireless transmission password before installation. Bus cable - HDL Bus/KNX cable, 0.8mm single-core copper cable. In Mesh mode, subnet ID of Gateway in RF port must be ■ Reliable transmission distance is 50m, obstacles will ■ Bus Connection - Series connection (hand-in-hand). reduce the transmission distance, the distance will de- ■ Connect to DC24V power. crease 20m if the wall stops it. So it is better to install ■ If needed, connect to RJ45. Mesh wireless devices in empty place and forbid to install near large area of metal objects. To ensure good communication quality, it is suggested not to install this device in electric box. If you have to, please add an external antenna to the device. Professional Home and Building Automation www.hdlautomation.com Do you need help? Contact with us [email protected] 1/ 2 www.hdlchina.com MESH Gateway HDL-MCIP-RF.10 Layout and Wiring Antenna PROG: programming key Pressing it for 3 successive times. Red LED gateway will be switched to set channel for Parameter settings, HDL-BUS user can program wireless devices by HDL Easy Engineering Editor Long press for 3 seconds to change ID in HDL Easy Engineering Editor software, 99.5 Working LED Long press for 10 seconds to default factory IP(192.168.10.250) Antenna: receives and transmits wireless signal. Working LED: Green LED flashes during normal operation and last for seconds each time. 107 LED Indicator: Red LED flashes quickly when it is programming. HDL-BUS 24VDC: power supply, if the device Green LED flashes when it receives or transmits 27 connects to the HDL-BUS, it need not connect to DC power wireless signal. Red/Green RJ45: Ethernet port RJ45 All indicators are on, the device will be restored Blue into default setting from factory. The Y of SubNet ID range in wired Bus is 0-254,X RJ45 SUB ID X X X X Device ID 1 2 ... 64 Mesh Panel …... Mesh Relay value is different from Y HDL Mesh gateway HDL-Bus SUB ID: X Mesh Curtain …... Device ID: 0 Relay SUB ID The X of SubNet ID range in RF network is 0-254,Y value is different Mesh mode from X. The gateway‘s device ID is 0, can not change it. Device ID Relay Y 1 Dimmer Y Y Y 2 ... 64 RJ45 HDL-Bus The SUB ID NO. is Y1 Relay SUB ID Device ID Y1 1 Dimmer Y1 2 …... HDL Mesh gateway1 SUB ID: X1 Relay Y1 Y1 ... 64 Device ID: 0 Device ID: 0 RF Relay Dimmer …... HDL Mesh gateway 2 SUB ID: X2 Relay SUB ID Y2 Y2 Y2 Y2 Device ID 1 2 ... 64 Device ID: 0 SUB ID RF …... Relay Relay Y3 Y3 Y3 Y3 2 ... 64 Device ID 1 Dimmer RF RF The SUB ID NO. is Y2 HDL-Bus The SUB ID NO. is Y3 HDL-Bus HDL Mesh gateway 3 SUB ID: X3 The SUB ID NO. is Y4 HDL-Bus HDL Mesh gateway 4 SUB ID: X4 Device ID: 0 Relay Bridge mode Dimmer …... Dimmer SUB ID Y4 Y4 Y4 Y4 Device ID 1 2 ... 64 In Bridge mode, all SubNet ID of gateway devices are different Safety attention ■ Do not make wrong connection on Bus interface, it will damage the Bus interface of this module. ■ Never let liquids get into the module, it will damage this device. ■ Do not get AC240V voltage into Bus wire , it will damage all devices in the system. ■ Ensure good ventilation. Professional Home and Building Automation www.hdlautomation.com Do you need help? Contact with us [email protected] 2/ 2
© Copyright 2024