li ndab | ceiling diff users - v isible Visible diffuser LCFV Dimensions H Ød1 A 1 2 ØA 3 B 4 5 Description LCFV is a VAV diffuser unit for supply air with circular unperforated face plate for free hanging installations. LCFV includes a unique linear cone damper with integrated volume flow regulator used for VAV regulation directly in the unit. The built-in VAV actuator is delivered pre-programmed with damper characteristic and in combination with a stable flow measurement over the damper, it makes the VAV regulation very accurate and reliable. 6 Ød1 mm ØA mm A mm H mm B mm 125 460 80 241 250 7,5 160 540 97 275 300 10,5 7 Weight kg 8 Construction 9 In Pascal system LCFV is controlled by a Regula Combi room controller where all room settings can be done after installation. This means that no factory settings or specific room labeling is needed for LCFV. 10 LCFV is as standard delivered with a special designed Regula Connect card, for easy and simple wiring. 11 • Free hanging VAV unit with integrated volume flow regulator • Suitable in full variable airflow range with high undertemperature (0-100%) • Unique linear cone damper • Up to 200 Pa with low sound level • Accurate and reliable VAV regulation • Settings can be done in Regula Combi after installation • Includes Regula Connect card for easy wiring 12 13 14 Maintenance The face plate can be detached and the damper removed to enable cleaning of the internal parts or the duct. The visible parts of the diffuser can be wiped with a damp cloth. 15 Materials and finish Material: Standard finish: Standard colour: Order code Product Type Size LCFV bbb Belimo motor: Galvanised steel Powder-coated White, RAL 9010, gloss 30 or white 9003, gloss 30 LHV-D3W-MP The diffuser is available in other colours. Please contact Lindab’s sales department for further information. We reserve the right to make changes without prior notice 2015-04-10 16 17 18 1 lindab | ceil ing di ffusers - vi sible Visible diffuser LCFV Technical data 1 2 3 4 Capacity Volume flow qv [l/s] and [m3/h], total pressure Δpt [Pa], throw l0.2 [m] and sound power level LWA [dB(A)] can be seen in the diagrams. Frequency-related sound effect level The sound effect level in the frequency band is defined as LWA + Kok Kok values are given in charts beneath the diagrams on the following pages. 6 7 The throw is specified at a terminal velocity of 0.2 m/s. l0.2 [m] 10 LCFV 125 160 7 6 5 4 3 Quick selection 5 Throw l0.2 2 Supply air l0.2 [m] Δpt ≥ 50 Pa Δpt ≥ 50 Pa 30 dB(A) 35 dB(A) duct Ød1 l/s m3/h l/s 1 15 m3/h 125 55 198 71 256 160 76 274 99 356 20 60 30 80 100 40 50 150 60 200 80 100 300 150 500 200 700 300 1000 qV [l/s] qV [m3/h] Sound attenuation Sound attenuation of the diffusers ΔL from duct to room, including end reflection, see table below 8 Centre frequency Hz 9 10 Size 63 125 250 500 1K 2K 4K 8K 125 16 9 12 8 10 11 16 21 160 13 9 11 6 9 8 15 20 Balancing Balancing data is contained in a separate brochure. 11 12 13 14 15 16 17 18 2 We reserve the right to make changes without prior notice 2015-04-10 li ndab | ceiling diff users - v isible Visible diffuser LCFV Technical data 1 Δpt [Pa] LCFV-125 250 200 2 50 150 45 100 40 3 70 35 50 30 30 25 20 4 20 15 LWA dB(A) 10 5 q [l/s] 10 15 20 30 40 50 60 70 100 150 V q [m3/h] 40 50 60 70 100 150 200 300 400 500 Hz 63 125 250 500 1K 2K 4K 8K Kok 7 7 -3 -6 -4 -8 -15 -17 Δpt [Pa] V 6 7 LCFV-160 250 200 150 50 100 8 45 40 70 35 50 9 30 30 25 20 20 15 10 LWA dB(A) 10 10 15 40 50 20 30 100 40 50 150 60 200 80 100 300 150 400 500 200 60 80 700 Hz 63 125 250 500 1K 2K 4K 8K Kok 10 9 -3 -6 -4 -10 -16 -14 qV [l/s] qV [m3/h] 11 12 13 14 15 16 17 18 We reserve the right to make changes without prior notice 2015-04-10 3
© Copyright 2024