Architectural Heater LPWA Series LPWA 24 A B 45 C -TP D A: Series B: 12 - 120V 24 - 240V 20 - 208V 27 - 270V C: Watts (1500 to 4500) D: Thermostat (optional) Pic-A-Watt® Element Cast Iron Motor 5-Blade Aluminum Fan 185 CFM Smart Limit Protection ® Multiple wattages Extruded aluminum grill Approved for direct contact with building insulation Selector Switch: Fan/Heat/Off 120, 208, 240, or 277 Volts Standard color aluminum, bronze & white optional The LPWA Architectural Heater Entryways, corridors and all public areas are best heated with the LPWA Series. The heavy grill and frame can withstand heavy traffic and abuse. Tamper-resistant screws prevent unauthorized disassembly of the grill. Controls are recessed out-of-reach of fiddling fingers. High wattage and airflow capacities replenish entryways and hallways to prevent drafts from entering the building’s core. Ordering Information 120V 208V 240V 277V MODEL LPWA1215 LPWA1220 LPWA1227 LPWA2020 LPWA2030 LPWA2040 LPWA2045 LPWA2420 LPWA2430 LPWA2440 LPWA2445 LPWA2720 LPWA2730 LPWA2740 *Add suffix -BZ for dark bronze, and -W for white UPC 18370 18372 18250 18374 18376 18251 18240 18378 18380 18382 18193 18384 18386 18252 VOLTS 120 120 120 208 208 208 208 240 240 240 240 277 277 277 WATTS 1500 2000 2750 2000 3000 4000 4500 2000 3000 4000 4500 2000 3000 4000 AMPS 12.5 16.7 22.9 9.6 14.4 19.2 21.6 8.3 12.5 16.6 18.75 7.2 10.8 14.4 SHIP WEIGHT lbs 24 24 24 24 24 24 24 24 24 24 24 24 24 24 Engineering Specifications Contractor shall supply and install LPWA Series in-wall mounted forced-air electric heaters manufactured by King Electrical Mfg. Company, of the wattage and voltage as indicated on the plans Grill: Heavy extruded 12 gauge aluminum provides high impact resistance to damage. Grill is attached with tamper-proof screws (hex socket/pinned). All controls are easily accessed through grill with slotted screwdriver. Standard color is anodized aluminum. Dark bronze or white is available. Elements: Element assemblies shall be non-glowing design. Element assemblies shall consist of steel sheathed heating tubes in a furnacebrazed, plate finned, block design. Each sheathed tube shall contain a coiled Ni-Chrome wire embedded in an insulator of Magnesium Oxide. The element assembly shall provide the specific wattage as indicated. Optional Built-in Thermostat: Single Pole factory installed hydraulic capillary tube with precision control. Operating range 40˚F to 90˚F. Thermostat is tamper-proof to prevent unauthorized adjustment. Fan / Heat / Off Switch: Tamper-proof 3-position switch provides heating and summer fan-only operation. The DPST off switch provides a “positive off”that disconnects all ungrounded conductors. Controls are easily accessed through grill with slotted screwdriver. If thermal overload trips due to abnormal operating temperatures, thermal overload shall remain open until manually reset by turning the heater off for 15 minutes. Fan Delay Switch: The fan continues to operate after the thermostat shuts off in order to remove the residual heat left in the elements. Unit Bearing Motor: Permanently cast iron lubricated motor with enclosed rotor provides long-lasting, trouble-free operation and a 20cc oil reservoir. Thermally protected. 1300 RPM. Indicator Light: Illuminates when the thermal cutout trips and turns off when the limit resets. Auto-Reset Thermal Cutout: Heater shuts off when an overheat condition exists and automatically resets when the normal operating temperature returns. Wall box: 20 gauge electro-galvanized steel. Factory installed ground-wire. Minimum 4” clearance to floors and 6”to sidewalls. Zero clearance to combustibles in the wall. Architectural Heater LPWA Series Optional Circuit Breaker / Disconnect: Transformer Relay 24V control. Approvals: UL(E41400) / cETL Thermal Overload: Heaters shall be equipped with King’s patented thermal overload Smart Limit Protection®, which disconnects elements and motor in the event normal operating temperatures are exceeded. Dimensional Data 1” 1½” MINIMUM CLEARANCE: Zero clearance to insulation recommended 10" above floor 6" from adjacent wall surface GRILL DEPTH = 1¾” 1¾” FRONT SIDE 1½” ½ K.O. ½ K.O. 23¼” 23” =knockout location 1” TOP ¾” ½ K.O. 3 ¾” 11½” 12-7/8” Options ADD SUFFIX -BZ -W -CT24 -CX -S -TP -CB2 -CB3 DESCRIPTION Grill - Dark Bronze Grill - White Transformer that converts 208, 240 and 277 Volts to 24 Volt Control Remote Circuit {add power contactor (-C) for 3kW - 5kW 1-Phase models} Contactor for 3kW - 5kW 1-Phase Models (Line Voltage Coil) Surface Can Included Factory Installed Tamper-proof Thermostat 20 Amp Double Pole Circuit Breaker / Disconnect 30 Amp Double Pole Circuit Breaker / Disconnect WEIGHT lbs 24 24 DESCRIPTION WEIGHT lbs 24.5 24.5 24 24 0.5 0.5 Accessories MODEL UPC LPWAIC LPWASA LPWAG LPWA-TP 18200 18197 18158 18140 WIRING DIAGRAM Architectural Recess Wall Can Surface Can LPWA Series Grill - Anodized Aluminum Tamper-proof Thermostat Replacement 6.5 5 7 2 breaker box for remote thermostat installation thermostat 75 heater Power must be routed to heater first, then to remote thermostat. Bronze White Mill Silver Anodized
© Copyright 2024