Report on Site Classification and Construction Site Classification and TestingCGS2398-002/0 Construction Testing CGS2398-002/0 Northlakes Estate Stage 33 & 34, Cameron Park Northlakes Estate Stage 33 & 34, CGS2398 Cameron Park CGS2398 Prepared for Northlakes Pty Ltd C/- McCloy Group Pty Ltd October 2014 Report on Site Classification and Construction TestingCGS2398-002/0 Northlakes Estate Stage 33 & 34, Cameron Park Prepared for Northlakes Pty Ltd C/- McCloy Group Pty Ltd Contact Information Document Information Cardno (NSW/ACT) Pty Ltd Trading as Cardno Geotech Solutions ABN 95 001 145 035 Prepared for Northlakes Pty Ltd C/- McCloy Group Pty Ltd Job Reference CGS2398 Project Name Northlakes Estate Stage 33 & 34, Cameron Park File Reference CGS2398-002.0 Date October 2014 4/5 Arunga Drive Beresfield NSW 2322 PO Box 4224 Edgeworth NSW 2285 Australia Telephone: 02 4949 4300 Facsimile: 02 4966 0485 International: +61 2 4949 4300 [email protected] www.cardno.com.au Version Document Control Version 0 0 Date Select date Description of Revision Initial issue Prepared By Prepared Reviewed Reviewed (Signature) By (Signature) KH Reason for Issue IGP Approved for Release By First issue to client Approved (Signature) Approved Release Date IGP © Cardno 2013. Copyright in the whole and every part of this document belongs to Cardno and may not be used, sold, transferred, copied or reproduced in whole or in part in any manner or form or in or on any media to any person other than by agreement with Cardno. This document is produced by Cardno solely for the benefit and use by the client in accordance with the terms of the engagement. Cardno does not and shall not assume any responsibility or liability whatsoever to any third party arising out of any use or reliance by any third party on the content of this document. CGS2398-002.0 October 2014 Cardno Geotech Solutions ii Report on Site Classification and Construction TestingCGS2398-002/0 Northlakes Estate Stage 33 & 34, Cameron Park Prepared for Northlakes Pty Ltd C/- McCloy Group Pty Ltd Table of Contents 1 Introduction 1 2 Site Description 1 3 Earthworks 2 3.1 3.2 3.3 3 3 3 3 3 Material Quality Methodology Results of Compaction Testing 3.3.1 Lot Regrade & General Fill 3.3.2 Pavement Testing 4 Investigation Methodology 4 5 Investigation Findings 4 5.1 5.2 5.3 4 4 7 6 Published Data Subsurface Conditions Laboratory Test Results Comments and Recommendations 6.1 6.2 Site Classification Footings 6.2.1 High-Level Footings 6.2.2 Piered Footings 8 8 10 10 10 7 Conclusions 11 8 Limitations 12 9 References 12 Appendices Appendix A Drawings Appendix B Engineering Logs Appendix C Laboratory Test Results Appendix D Compaction Test Results Appendix E CSIRO Information Sheet BTF18 Tables Table 5-1 Summary of subsurface conditions 6 Table 5-2 Summary of Shrink Swell Test Results 7 Table 6-1 General Definition of Site Classes 8 Table 6-2 Summary of Site Classifications 9 CGS2398-002.0 October 2014 Cardno Geotech Solutions iii Report on Site Classification and Construction TestingCGS2398-002/0 Northlakes Estate Stage 33 & 34, Cameron Park Prepared for Northlakes Pty Ltd C/- McCloy Group Pty Ltd 1 Introduction This report presents the results of geotechnical investigation undertaken by Cardno Geotech Solutions (CGS) on Stage 33 and 34 of the Northlakes Estate development located at Cameron Park. The work was conducted at the request of Mr Andrew Day of McCloy Group Pty Ltd. The report describes the results of construction control testing undertaken by CGS throughout Stages 33 and 34 earthworks in accordance with Australian Standard 3798-2007, Guidelines for Earthworks on Residential and Commercial Developments [1]. The report details investigation required to provide site classification of the Stage 33 and 34 lots in accordance with Australian Standard AS 2870-2011 Residential Slabs and Footings [2]. For the purpose of the investigation, Parson Brinckerhoff (PB) construction plans were provided by McCloy Group, reference ‘2118995A-1700-CIV-1702’ revision 0 dated 11.11.2013 and ‘2118995A-1800-CIV-1802’ revision 0 dated 30.10.2013. A regrade depth plan was provided by Daracon Group providing information on the surveyed cut and fill depths, Daracon project number ‘1293’, dated 28.09.2014. 2 Site Description The site is defined as Stage 33 and 34 Northlakes Estate and is located on the north-western extent of the existing Northlakes residential development. The site is irregular in shape and is bounded bushland and Cameron Park Drive to the north and west, a strip of bushland and a natural gully to the south and existing stages 31 and 32 to the east. Stage 33 and 34 comprises the creation of 61 residential allotments, construction of internal road pavements and other associated infrastructure as follows: > Stage 33 comprises 26 residential allotments (lots 3301-3326). > Stage 34 comprises 36 residential allotments (lots 3401-3436). At the time of investigation, construction of Stage 33 and 34 was practically complete, with only minor landscaping works remaining. Topographically the site is located on the spine and south-east to south-west facing slopes of a spur. The spur descends in a generally north to south direction from a north-east to south-west trending dominant ridgeline which follows the approximate alignment of Cameron Park Drive. Surfaces within the site sloped at the following measured gradients: > Stage 33: - Lots 3301-3308 sloped to the south and south-west at measured gradients of 5-8°. - Lots 3309-3322 sloped to the west and south-west at measured gradients of 6-12°. - Lots 3323-3326 sloped to the south and south-east at measured gradients of 5-12°. > Stage 34: - Lots 3401-3406 sloped to the south and south-west at measured gradients of 4-7°. - Lots 3407-3414 sloped to the east and south-east at measured gradients of 5-12°. - Lots 3415-3426 sloped to the west and south-west at measured gradients of 8-19°. - Lots 3427-3436 sloped to the south-west at measured gradients of 7-12°. A natural drainage line traverses north to south through Stage 33 coincident with part of the Manlius Drive alignment commencing in the area of the Fire Trail 02 intersection connecting Santa Maria Close with Manlius Drive. The drainage line feeds into a larger gully which follows the approximate alignment of Manlius CGS2398-002.0 October 2014 Cardno Geotech Solutions 1 Report on Site Classification and Construction TestingCGS2398-002/0 Northlakes Estate Stage 33 & 34, Cameron Park Prepared for Northlakes Pty Ltd C/- McCloy Group Pty Ltd Drive to the south of the site. Extensive regrade has been conducted along Manlius Drive comprising filling of the drainage line and gully slopes up to 4.5 m. Locally steeper surfaces were observed within the faces of the gully to the south and south-west of Manlius Drive with gradients of up to 18-26° measured. Earthworks within lots 3301-3307, 3321-3326, 3401-3407 and 3426 comprised benching of the individual lots generally by locally filling (lots 3323-3326), locally cutting (lots 3301-3302, 3407 and 3426) or locally cutting and filling (lots 3303-3305, 3321-3322 and 3401-3406) to create level platforms. Based off the overall plan sheet ‘2118995A-1700-CIV-1702’ and ‘2118995A-1800-CIV-1802’ provided, natural surfaces in these lots prior to development sloped to the south-west at gradients of approximately 8-12° and as a result of the earthworks the individual allotments are now relatively flat. Minimal regrade has been conducted within the remaining lots, with scattered semi mature to mature trees observed across these lots. Drainage across the site is expected to comprise surface flows following the natural and constructed slopes, via the inter-allotment and internal road drainage network, ultimately to a drainage basin to the south of the site. 3 Earthworks Earthworks for the development of Stages 33 and 34 commenced in March 2014 and were carried out by Daracon Group which included the development of: > 26 residential allotments (lots 3301-3326) comprising Stage 33 > 36 residential allotments (lots 3401-3436) comprising Stage 34. > Manilius Drive (Road 50) between CH129m and CH512m. > Yarborough Drive (Road 51) between CH0m and CH335m. > Dunsyre Avenue (Road 54) between CH0m and CH210m. > Santa Maria Close (Road 53) between CH0 and CH133. Earthworks within lots 3301-3307, 3321-3326, 3401-3407 and 3426 comprised benching of the individual lots generally by locally filling (lots 3323-3326), locally cutting (lots 3301-3302, 3406-3407 and 3426) or locally cutting and filling (lots 3303-3305, 3321-3322 and 3401-3405) to create level platforms. Earthworks for road construction included minor regrade in lots 3311-3318, 3408-3309, 3416-3419 and 3427-3429 in areas adjoining the road alignments to enable suitable grades between the lots and alignments. The lots affected by regrade are shown on the regrade depth plan provided by Daracon Group reference ‘1293 Northlakes Stages 33 & 34 Cut Fill Depth Range’ dated 28 August 2014 attached in Appendix A. Generally lot regrade activities undertaken by Daracon Group resulted in the following maximum fill depths: > Up to 3.0m of filling within benched lots 3323-3326. > Up to 2.0m of filling within benched lots 3321-3322. > Up to 1.5m of filling within benched lots 3305 and 3401-3405. > Up to 5.0m of filling within Manilius road reserve. > Up to 0.5m of filling within Yarborough road reserve. > Up to 2.5m of filling within lots 3308-3309 and 3312-3314 adjoining Manilius road alignments. > Minor filling up to 0.5m within lots 3306, 3311, 3316-3320, 3411-3412, 3420 and 3431-3436 adjoining road alignments. Testing was undertaken on lot fill in accordance with Section 8 of AS 3798-2007 [1]. It is noted that site regrade activities were sporadic due to inclement weather and staging of works. CGS2398-002.0 October 2014 Cardno Geotech Solutions 2 Report on Site Classification and Construction TestingCGS2398-002/0 Northlakes Estate Stage 33 & 34, Cameron Park Prepared for Northlakes Pty Ltd C/- McCloy Group Pty Ltd Earthworks were undertaken utilising surplus material acquired from adjacent stages and onsite materials acquired from road cuttings and regrade and comprised silty and sandy clay with varying proportions of gravel. 3.1 Material Quality Onsite materials encountered, including stockpiles of surplus material from adjacent stages, comprised clay, sandy clay, silty clay and weathered siltstone and sandstone. Onsite materials other than topsoil were generally deemed suitable for use as general fill. Some materials required moisture reconditioning and blending along with removal of organic matter prior to use. 3.2 Methodology Regrade operations were undertaken by removing the topsoil, and any uncontrolled fill to expose the natural in situ soils which were free of significant organic matter. Natural surfaces were inspected and proof rolled using a compactor or wheeled construction equipment that was available at the time of inspection. Unsuitable materials were removed and replaced with select fill. Fill operations were undertaken by placing layers of approximately 200mm to 300mm thickness and compacting to specified limits. Compacted fill layers were then tested for compaction in accordance with the guidelines indicated in AS 3798-2007 Guidelines for Earthworks on Residential and Commercial Developments (Australian Standard AS3798-2007) [1]. Table 5.1 Item 1 of AS 3798-2007 was adopted as the appropriate compaction criteria by the client for the work with a minimum relative compaction of 95% standard required as appropriate for residential - lot fill housing sites. Fill was tested in accordance with Table 8.1 Frequency of Field Density Tests for Type 1 Large Scale Operations (Australian Standard AS3798-2007) [1]. Placement and compaction of fill was undertaken with Cardno Geotech Solutions site personnel providing onsite inspection and testing services during earthworks activities. 3.3 Results of Compaction Testing 3.3.1 Lot Regrade & General Fill Results of compaction testing of lot regrade areas undertaken by Geotech Solutions indicate that the filling operations have satisfied the compaction criteria for “controlled fill” as defined in Clause 1.8.13 of AS28702011 [2]. All testing has either met with or exceeded the specification adopted of 95% standard compaction at moisture contents of generally 85% to 115% of Optimum Moisture Content (OMC) at the time of placement with any failures being re-worked and retested. Geotechnical services provided during regrade comply with AS 3798-2007 [2], with testing undertaken to the minimum frequency as indicated in Table 8.1 for Type 1 – Large Scale Operations. A total of thirty four (34) lot regrade and one hundred and forty two (142) general fill compaction test results from Stages 33 and 34 are included in this report. The results of compaction testing, along with proof rolling, meet the requirements of Lake Macquarie City Council Engineering Guidelines Part 2 Construction Specification [3]. Compaction results are shown on NATA accredited test certificates, attached in Appendix D 3.3.2 Pavement Testing A total of one hundred and sixty one (161) compaction tests were undertaken during the construction of roads and associated infrastructure within Stage 33 and 34 including: > Thirty two (32) subgrade tests. > Thirty one (31) subbase tests. > Twenty nine (29) basecourse tests. CGS2398-002.0 October 2014 Cardno Geotech Solutions 3 Report on Site Classification and Construction TestingCGS2398-002/0 Northlakes Estate Stage 33 & 34, Cameron Park Prepared for Northlakes Pty Ltd C/- McCloy Group Pty Ltd > Sixty nine (69) pipe backfill tests. Testing was undertaken to meet the requirements of Lake Macquarie City Council Engineering Guidelines Part 2 Construction Specification [3]. All testing either met or exceeded the specification requirements with any failures being re-worked and retested. NATA accredited test certificates are attached in Appendix D. Six (6) Benkelman Beam tests were undertaken to determine in-situ basecourse deflections within Manilius, Yarborough, Dunsyre and Santa Maria road reserves. Mean deflections ranged between 0.17 and 0.72mm and Characteristic deflections ranged between 0.35 and 1.34mm. 4 Investigation Methodology Field investigation was undertaken on the 09 and19 September 2014 and comprised the excavation of fortythree (43) test bores (TB001-TB043) using a 3.5T excavator fitted with a 200mm auger attachment. Test bores were excavated to a target depth of 1.8 m, with thirty-seven (37) bores terminated due to refusal on rock. Dynamic Cone Penetrometer tests (DCP) were conducted adjacent to the majority of test bores to aid in the assessment of subsurface strength conditions. Thin wall tube (50mm diameter) samples of selected materials from the bores were collected for subsequent laboratory testing. All fieldwork including setting out test bore locations, logging of subsurface profiles and collection of samples was carried out by a Geotechnical Engineer from CGS. The bore locations relative to allotment boundaries and site features are shown in drawing CGS2398-002-d1 to CGS2398-002-d4, attached in Appendix A. Subsurface conditions are summarised in Section 5.2 and detailed in the engineering logs of test bores attached in Appendix B, together with explanatory notes. Laboratory testing on selected samples recovered during fieldwork comprised of shrink swell tests carried out on thin wall tube (50mm diameter) samples of the natural clays and fill materials encountered at the site to measure soil volume change over an extreme soil moisture content range. Results of laboratory testing are detailed in the reports sheets attached in Appendix C, and summarised in Section 5.3. 5 Investigation Findings 5.1 Published Data Reference to Newcastle Coalfield Geology Map, Geological Series Sheet 9231 Ed1 1995 indicates that the site is situated within the Permian Age Newcastle Coal measures in the vicinity of the Boolaroo Subgroup formation. This formation is known to comprise sandstone, conglomerate, siltstone, coal and tuff rock types and residual soils derived from weathering of these rocks. 5.2 Subsurface Conditions The subsurface conditions encountered in the test bores excavated across the site are detailed on the report log sheets, and attached in Appendix B together with explanatory notes. The natural subsurface profile within the allotments generally comprised silty clay overlying weathered siltstone, sandstone, coal and tuff rock and silty clay filling and silty clay overlying weathered sandstone rock. Fill materials observed within the benched lots 3301-3305, 3321-3326, 3401-3407 and 3426 generally comprised silty or gravelly sand or silty, sandy and/or gravelly clays. The fill materials utilised were either site won or sourced from surplus material from adjacent stages. Based on results of construction control testing conducted by CGS during subdivision constriction, the fill material placed within the allotments has been placed as controlled fill in accordance with AS3798-2007 [1]. CGS2398-002.0 October 2014 Cardno Geotech Solutions 4 Report on Site Classification and Construction TestingCGS2398-002/0 Northlakes Estate Stage 33 & 34, Cameron Park Prepared for Northlakes Pty Ltd C/- McCloy Group Pty Ltd Based on DCP blow counts, the natural clays were predominantly stiff to hard in consistency at the time of the investigation. A general summary of the subsurface conditions encountered across the site is presented below in Table 51. CGS2398-002.0 October 2014 Cardno Geotech Solutions 5 Report on Site Classification and Construction TestingCGS2398-002/0 Northlakes Estate Stage 33 & 34, Cameron Park Prepared for Northlakes Pty Ltd C/- McCloy Group Pty Ltd Table 5-1 Summary of subsurface conditions Test Bore Topsoil / fill (m) Practical refusal / test bore depth (m) Summary of subsurface profile 001 0.10 0.30 (Fill) Silty SAND / XW SILTSTONE 002 0.15 0.60 (Fill) Silty SAND / Sandy CLAY / XW SANDSTONE 003 0.20 0.40 (Fill) Silty SAND / XW SANDSTONE 004 0.20 0.80 (Fill) Silty SAND / XW SANDSTONE 005 0.55 0.60 (Fill) Silty SAND / (Fill) Silty CLAY / XW SANDSTONE 006 0.80 0.80 (Fill) Silty SAND / (Fill) Sandy Gravelly CLAY / XW SANDSTONE 007 0.80 1.20 (Fill) Gravelly SAND / (Fill) Silty CLAY / Silty Clay / Sandy CLAY / XW SANDSTONE 008 0.50 0.80 (Fill) Gravelly SAND / Silty Sandy CLAY / XW SANDSTONE 009 0.35 1.00 (Fill) Silty CLAY / Silty Sandy CLAY / XW SILTSTONE 010 0.10 0.60 (Fill) Gravelly SAND / TOPSOIL / Silty Sandy CLAY / XW SILTSTONE 011 0.10 0.25 (Fill) Gravelly SAND / XW SILTSTONE 012 0.30 1.00 (Fill) Sandy CLAY / Silty CLAY / CLAY / XW SILTSTONE 013 0.15 2.00* (Fill) Sandy Silty CLAY / Silty CLAY 014 0.10 2.00* TOPSOIL / Silty CLAY 015 0.20 2.00* TOPSOIL / Silty CLAY 016 0.30 1.20 TOPSOIL / Silty CLAY / XW SILTSTONE 017 NE 2.00* Silty CLAY 018 0.40 1.30 (Fill) Silty Clayey SAND / (Fill) Gravelly SAND / Silty CLAY / XW SILTSTONE 019 0.15 2.00* (Fill) Silty CLAY / Silty CLAY / XW SILTSTONE 020 0.05 1.20 (Fill) Silty Sandy CLAY / Silty CLAY / XW SILTSTONE 021 0.40 1.30 TOPSOIL / Silty Sandy CLAY / XW SILTSTONE 022 0.20 1.80 (Fill) Silty Sandy CLAY / Silty Sandy CLAY / XW SILTSTONE 023 1.10 1.60 (Fill) Silty Sandy CLAY / (Fill) Gravelly CLAY / Silty Sandy CLAY / XW SILTSTONE 024 2.00 2.00* (Fill) Clayey Silty SAND / (FILL) Gravelly Silty CLAY / (Fill) Silty CLAY 025 0.10 1.90 (Fill) Silty Clayey SAND / Silty Sandy CLAY / Silty CLAY / XW SILTSTONE 026 0.20 0.70 Mulch / TOPSOIL / Silty CLAY / DW SANDSTONE 027 NE 0.80 Silty CLAY / XW SANDSTONE 028 0.05 0.70 Mulch / Sandy Silty CLAY / XW SANDSTONE 029 0.05 0.70 Mulch / Sandy Silty CLAY / XW SANDSTONE 030 0.05 0.60 Mulch / Silty Sandy CLAY / Sandy CLAY Silt / DW SANDSTONE 031 0.05 0.70 Mulch / Silty SAND / Sandy CLAY / DW SANDSTONE 032 0.05 0.80 Mulch / Sandy CLAY / DW SANDSTONE 033 0.05 1.00 Mulch / Silty SAND / Silty CLAY / DW SANDSTONE 034 0.20 1.10 Mulch / (Fill) Silty Clayey SAND / Silty CLAY / DW SANDSTONE 035 NE 1.30 Sandy CLAY / Silty CLAY / Sandy CLAY / XW SANDSTONE 036 0.05 0.90 Mulch / Silty Clayey SAND / Silty Sandy CLAY / XW SANDSTONE CGS2398-002.0 October 2014 Cardno Geotech Solutions 6 Report on Site Classification and Construction TestingCGS2398-002/0 Northlakes Estate Stage 33 & 34, Cameron Park Prepared for Northlakes Pty Ltd C/- McCloy Group Pty Ltd 037 NE 1.00 Silty Clayey SAND / Silty CLAY / XW SANDSTONE 038 0.05 1.20 Mulch / Silty Clayey SAND / Silty CLAY / Sandy CLAY / XW SANDSTONE 039 0.05 1.20 Mulch / Silty Clayey SAND / Silty CLAY / Sandy CLAY / XW SANDSTONE 040 0.60 1.10 Mulch / (Fill) Sandy Gravelly CLAY / (Fill) Silty CLAY / Silty CLAY / XW SANDSTONE 041 1.50 1.80* Mulch / (Fill) Silty Sandy CLAY / Silty CLAY 042 1.40 1.50 (Fill) Silty Sandy CLAY / XW SANDSTONE 043 1.30 1.50 (Fill) Clayey Silty SAND, (Fill) Silty SAND and CLAY / (Fill) Silty Sandy CLAY / Silty CLAY Notes: NE – not encountered Depths in bold indicate fill * Indicates target depth reached Groundwater seepage was encountered in test bore TB016. No groundwater or seepage was encountered in any of the other test bores at the time of fieldwork. It should be noted that groundwater levels are likely to fluctuate with variations in climatic and site conditions. 5.3 Laboratory Test Results The results of the laboratory shrink swell tests undertaken on samples of the clay soils encountered during the investigation are detailed on the laboratory test report sheets attached in Appendix C, and are summarised below in Table 5-2. Table 5-2 Summary of Shrink Swell Test Results Test Bore Depth (m) Soil Type Esw (%) Esh (%) Iss (%) 005 0.20 - 0.35 Fill: Silty CLAY 0.0 0.9 0.5 007 0.70 - 0.96 Fill: Silty CLAY 0.0 3.6 2.0 013 0.50 - 0.72 Silty CLAY 0.8 6.6 3.9 015 1.20 - 1.46 Silty CLAY 0.9 6.4 3.8 019 0.50 - 0.70 Silty CLAY 0.1 4.2 2.3 023 0.20 - 0.40 Gravelly CLAY 0.0 1.8 1.0 033 0.20 - 0.50 Silty CLAY 1.6 1.9 1.5 035 0.30 - 0.45 Silty CLAY 1.6 3.2 2.3 038 0.20 - 0.40 Silty CLAY 1.6 5.3 3.4 Notes: Esw Swelling strain Esh Shrinkage strain Iss Shrink swell Index The laboratory shrink swell test results summarised in Table 5-2 indicate the following: > The natural silty clay soils tested are moderately to highly reactive, with Iss values in the range of 1.5% to 3.9%. > The natural gravelly clay soil tested is slightly reactive with an Iss value of 1.0%. > The silty clay fill materials tested are slightly to moderately reactive with Iss values in the range of 0.5% to 2.0%. CGS2398-002.0 October 2014 Cardno Geotech Solutions 7 Report on Site Classification and Construction TestingCGS2398-002/0 Northlakes Estate Stage 33 & 34, Cameron Park Prepared for Northlakes Pty Ltd C/- McCloy Group Pty Ltd 6 Comments and Recommendations 6.1 Site Classification Australian Standard AS 2870-2011 [2] establishes performance requirements and specific designs for common foundation conditions as well as providing guidance on the design of footing systems using engineering principles. Site classes as defined on Table 2.1 and 2.3 of AS 2870 are presented on Table 6-1 below. Table 6-1 Site Class General Definition of Site Classes Characteristic Surface Movement Foundation A Most sand and rock sites with little or no ground movement from moisture changes S Slightly reactive clay sites, which may experience only slight ground movement from moisture changes 0 - 20mm M Moderately reactive clay or silt sites, which may experience moderate ground movement from moisture changes 20 - 40mm H1 Highly reactive clay sites, which may experience high ground movement from moisture changes 40 - 60mm H2 Highly reactive clay sites, which may experience very high ground movement from moisture changes 60 - 75mm E Extremely reactive sites, which may experience extreme ground movement from moisture changes A to P Filled sites (refer to clause 2.4.6 of AS 2870) P Sites which include soft soils, such as soft clay or silt or loose sands; landslip; mine subsidence; collapsing soils; soils subject to erosion; reactive sites subject to abnormal moisture conditions or sites which cannot be classified otherwise. > 75mm Reactive sites are sites consisting of clay soils that swell on wetting and shrink on drying, resulting in ground movements that can damage lightly loaded structures. The amount of ground movement is related to the physical properties of the clay and environmental factors such as climate, vegetation and watering. A higher probability of damage can occur on reactive sites where abnormal moisture conditions occur, as defined in AS 2870, due to factors such as: > Presence of trees on the building site or adjacent site, removal of trees prior to or after construction, and the growth of trees too close to a footing. The proximity of mature trees and their effect on foundations should be considered when determining building areas within each allotment (refer to AS 2870); > Failure to provide adequate site drainage or lack of maintenance of site drainage, failure to repair plumbing leaks and excessive or irregular watering of gardens; > Unusual moisture conditions caused by removal of structures, ground covers (such as pavements), drains, dams, swimming pools, tanks etc. In regard to the performance of footings systems, AS 2870 states “footing systems designed and constructed in accordance with this Standard on a normal site (see Clause 1.3.2) [2] that is: (a) not subject to abnormal moisture conditions; and (b) maintained such that the original site classification remains valid and abnormal moisture conditions do not develop; are expected to experience usually no damage, a low incidence of damage category 1 and an occasional incidence of damage category 2.” Damage categories are defined in Appendix C of AS 2870, which is reproduced in CSIRO Information Sheet BTF 18, Foundation Maintenance and Footing Performance: A Homeowner’s Guide. CGS2398-002.0 October 2014 Cardno Geotech Solutions 8 Report on Site Classification and Construction TestingCGS2398-002/0 Northlakes Estate Stage 33 & 34, Cameron Park Prepared for Northlakes Pty Ltd C/- McCloy Group Pty Ltd The laboratory shrink swell test results summarised in Table 5-2 indicate the following: > The natural silty clay soils tested are moderately to highly reactive, with Iss values in the range of 1.5% to 3.9%. > The natural gravelly clay soil tested is slightly reactive with an Iss value of 1.0%. > The silty clay fill materials tested are slightly to moderately reactive with Iss values in the range of 0.5% to 2.0%. The classification of sites with controlled fill of depths greater than 0.4m (deep fill) comprising of material other than sand would be Class P. An alternative classification may however be given to sites with controlled fill where consideration is made to the potential for movement of the fill and underlying soil based on the moisture conditions at the time of construction and the long term equilibrium moisture conditions. Based on the results of fieldwork and laboratory test results and in accordance with the AS2870-2011 [2]; the lots in their existing condition and in the absence of abnormal moisture conditions would be classified as detailed in Table 6-2. Table 6-2 Summary of Site Classifications Lot Numbers Site Classification 3303-3304 3406 Class A, Non-Reactive (Provided footings are founded directly on exposed rock) 3301-3302 and 3305-3314 3403, 3405, 3428-3431 and 3434-3436 Class S, Slightly Reactive (Recommend adopt Class M, Moderately Reactive for lots 3310-3311, 3314 and 3405) 3315-3318 and 3321-3322 3401-3402, 3404, 3407, 34103411, 3414-3427 and 3432-3433 Class M, Moderately Reactive (Recommend adopt Class H1, Highly Reactive for lots 3322 and 3415-3416) 3319-3320 and 3323-3326 3408-3409 and 3412-3413 Class H1, Highly Reactive A characteristic surface movement in the range of 5-20mm has been calculated for lots 3301-3302, 33053314, 3403, 3405, 3428-3431 and 3434-3436, in the range of 20-40mm for lots 3315-3318, 3321-3322, 3401-3402, 3404, 3407, 3410-3411, 3414-3427 and 3432-3433, and in the range of 40-55mm for lots 33193320, 3323-3326, 3408-3409 and 3412-3413, based on a design depth of suction change (Hs) of 1.8m The calculated characteristic surface movement for lots 3310-3311, 3314, 3405 is considered a high order Class S, Slightly Reactive, classification (that is, greater than 15mm) and consideration should be given to the adoption of a conservative Class M moderately reactive classification for the purpose of footing and slab design. Similarly, the calculated characteristic surface movement for lots 3322, 3415-3416 are considered a high order Class M, Moderately Reactive classification (that is, greater than 35mm) and consideration should be given to the adoption of a conservative Class H1 highly reactive classification. As noted in Section 2, scattered semi mature to mature trees were noted within lots 3408-3425, 3427-3436 and 3306-3320. In consideration of the site conditions and Clause 1.3.3 of AS 2870-2011, the presence of mature trees may be considered to result in abnormal moisture conditions at the site. These trees should be removed from within the building area and surrounding areas to distances as detailed in Appendix B of AS 2870-2011. Following removal of trees, sufficient time should be allowed for the soil moisture to re-equilibrate or the soil should be moisture reconditioned prior to construction. It should be appreciated that the site classifications provided above are based on test bores and laboratory testing of multiple layers over the depth of total soil suction change in the soil profile. It should be noted that individual lot development can include other geotechnical studies and care should be taken that single laboratory results are not allocated to the full depth of the soil profile, as biased site classifications can result. Similarly there is the potential for dissimilar founding conditions encountered across individual lots, i.e. CGS2398-002.0 October 2014 Cardno Geotech Solutions 9 Report on Site Classification and Construction TestingCGS2398-002/0 Northlakes Estate Stage 33 & 34, Cameron Park Prepared for Northlakes Pty Ltd C/- McCloy Group Pty Ltd shallow rock and site clays. Footings for the support of the proposed structures should be founded on the same material. The above site classifications and footing recommendations are for the site conditions present at the time of fieldwork and consequently the site classification may need to be reviewed with consideration of any site works that may be undertaken subsequent to the investigation and this report. Site works may include: > Changes to the existing soil profile by cutting and filling; > Landscaping, including trees removed or planted in the general building area; and > Drainage and watering systems. Designs and design methods presented in AS 2870-2011 [2] are based on the performance requirement that significant damage can be avoided provided that site conditions are properly maintained. Performance requirements and foundation maintenance are outlined in Appendix B of AS 2870. The above site classification assumes that the performance requirements as set out in Appendix B of AS 2870 are acceptable and that site foundation maintenance is undertaken to avoid extremes of wetting and drying. Details on appropriate site and foundation maintenance practices are presented in Appendix B of AS 28702011 and in CSIRO Information Sheet BTF 18, Foundation Maintenance and Footing Performance: A Homeowner’s Guide, which is attached as Appendix E of this report along with Australian Geoguide (LR8) Hillside Construction Practice. Adherence to the detailing requirement outlined in Section 5 of AS 2870-2011 [2] is essential, in particular Section 5.6 Additional requirements for Classes M, H1, H2 and E sites, including architectural restrictions, plumbing and drainage requirements. 6.2 Footings All foundations should be designed and constructed in accordance with AS 2870-2011, Residential Slabs and Footings [2] with reference to site classifications as presented in Table 6-2. All footings should be founded below any topsoil, slopewash, deleterious soils or uncontrolled fill. All footings for the same structure should be founded on strata of similar stiffness and reactivity to minimise the risk of differential movements. 6.2.1 High-Level Footings High-level footing alternatives could be expected to comprise slabs on ground with edge beams or pad footings for the support of concentrated loads. Such footings designed in accordance with engineering principles and founded in stiff or better natural soils (below topsoil, slopewash, uncontrolled fill or other deleterious material) or in controlled fill (placed and compacted in accordance with AS3798-2007 [1]) may be proportioned on an allowable bearing capacity of 100kPa. The founding conditions should be assessed by a geotechnical consultant or experienced engineer to confirm suitable conditions. 6.2.2 Piered Footings Piered footings are considered as an alternative to deep edge beams or high level footings. It is suggested that piered footings, founded in stiff or better clay soils or controlled fill could be proportioned on an end bearing pressure of 100kPa. Where uniformly founded in the underlying rock, an end bearing pressure of 500kPa could be adopted. Where piered footing are utilised, the potential for volume change in the subsurface profile should be taken into considered by the designer. All footings should be founded below any topsoil, slopewash, deleterious soils or uncontrolled fill. All footings for the same structure should be founded on strata of similar stiffness and reactivity to minimise the risk of differential movements. CGS2398-002.0 October 2014 Cardno Geotech Solutions 10 Report on Site Classification and Construction TestingCGS2398-002/0 Northlakes Estate Stage 33 & 34, Cameron Park Prepared for Northlakes Pty Ltd C/- McCloy Group Pty Ltd Inspection of high level or pier footings excavations should be undertaken to confirm the founding conditions and the base should be cleared of fall-in prior to the formation of the footing. 7 Conclusions Earthworks undertaken for Stage 33 and 34 of the Northlakes Estate development have been undertaken in accordance with guidelines outlined in AS3798-2007 [1]. Fill material placed was tested at the frequency specified in Table 8.1 from AS3798-2007 [1]. Placement and compaction of fill was observed by CGS site personnel, who provided onsite inspection and monitoring during earthworks activities. The investigation revealed a subsurface profile generally comprising natural gravelly clay, silty clay and sandy clay overlying weathered siltstone and sandstone rock and site won silty sand, gravelly sand, silty clay and sandy clay fill materials. With reference to earthworks monitoring by CGS, fill materials within the lots have been placed as controlled fill in accordance with AS3798-2007 [1]. As specified in AS2870-2011 [2], the classification of sites with deep controlled fill is Class P; however an alternative classification has been given to the lots with consideration of the fill being placed as controlled fill in accordance with AS3798-2007 and to long term moisture equilibrium conditions of the controlled fill profile. Based on the subsurface profiles encountered and laboratory test results, and in accordance with AS28702011 [2], the Stage 33 and 34 lots are classified as follows: > 3303-3304 and 3406 are classified as Class A, Non-Reactive. > 3301-3302, 3305-3314, 3403, 3405, 3428-3431 and 3434-3436 are classified as Class S, Slightly Reactive. > 3315-3318, 3321-3322, 3401-3402, 3404, 3407, 3410-3411, 3414-3427 and 3432-3433 are classified as Class M, Moderately Reactive. > 3319-3320, 3323-3326, 3408-3409 and 3412-3413 are classified as Class H1, Highly Reactive. Consideration should be given to the adoption of Class M, Moderately Reactive, for lots 3310-3311, 3314 and 3405 and Class H1, Highly Reactive, for lots 3322 and 3415-3416. Footings founded in natural stiff or better clay soils or controlled fill may be proportioned on an allowable bearing pressure of 100kPa. Piered footings founded uniformly on rock could be proportioned on an allowable bearing pressure of 500kPa. Inspection of footings by a geotechnical consultant or experienced engineer is required to provide confirmation of founding conditions. CGS2398-002.0 October 2014 Cardno Geotech Solutions 11 Report on Site Classification and Construction TestingCGS2398-002/0 Northlakes Estate Stage 33 & 34, Cameron Park Prepared for Northlakes Pty Ltd C/- McCloy Group Pty Ltd 8 Limitations Cardno Geotech Solutions (CGS) have performed investigation and consulting services for this project in general accordance with current professional and industry standards. The extent of testing was limited to discrete test locations and variations in ground conditions can occur between test locations that cannot be inferred or predicted. A geotechnical consultant or qualified engineer shall provide inspections during construction to confirm assumed conditions in this assessment. If subsurface conditions encountered during construction differ from those given in this report, further advice shall be sought without delay. Cardno Geotech Solutions, or any other reputable consultant, cannot provide unqualified warranties nor does it assume any liability for the site conditions not observed or accessible during the investigations. Site conditions may also change subsequent to the investigations and assessment due to ongoing use. This report and associated documentation was undertaken for the specific purpose described in the report and shall not be relied on for other purposes. This report was prepared solely for the use by Northlakes Pty Ltd C/- McCloy Group Pty Ltd and any reliance assumed by other parties on this report shall be at such parties own risk. 9 References [1] Australian Standard AS3798-2007, “Guidelines on Earthworks for Commercial and Residential Structures,” Standards Australia, 2007. [2] Australian Standard AS2870-2011, “Residential Slabs and Footings,” Standards Australia, 2011. [3] LMCC Engineering Guidelines - Part 2, “Construction Specification,” Lake Macquarie City Council, September 2003. CGS2398-002.0 October 2014 Cardno Geotech Solutions 12 Report on Site ClassificationCGS2398-002/0 Northlakes Estate Stage 33 & 34, Cameron Park Prepared for Northlakes Pty Ltd C/- McCloy Group Pty Ltd APPENDIX A DRAWINGS CGS2398-002.0 October 2014 Cardno Geotech Solutions 10 SITE NOTES: TB023 Drawing adapted from Parson Brinckerhoff (PB) construction plan reference '2118995A-1700-CIV-1702' revision 0 dated 11.11.2013 TB040 TB024 LEGEND: Approximate test bore locations and numbers TB041 TB025 TB042 TB043 TB039 TB038 TB035 TB034 DRAWING TITLE: PROJECT NAME: SITE LOCATION: TEST PIT LOCATION PLAN SITE CLASSIFICATION NORTHLAKES ESTATE STAGES 33 & 34, CAMERON PARK CLIENT: Northlakes Pty Ltd C/- McCloy Group PROJECT NO: CGS2398 DRAWING NO: 1 FILE REF: 2398-002-d1 DRAWN BY: KH OFFICE: 4/5 Arunga Drive, Beresfield NSW 2322 DATE: 03 OCTOBER 2014 CHECKED BY: IDP SITE TB035 TB034 TB023 TB033 NOTES: Drawing adapted from Parson Brinckerhoff (PB) construction plan reference '2118995A-1700-CIV-1702' revision 0 dated 11.11.2013 LEGEND: Approximate test pit locations and numbers TB032 TB005 TB030 TB004 TB003 TB031 TB002 TB001 DRAWING TITLE: PROJECT NAME: SITE LOCATION: TEST PIT LOCATION PLAN SITE CLASSIFICATION NORTHLAKES ESTATE STAGES 33 & 34, CAMERON PARK CLIENT: Northlakes Pty Ltd C/- McCloy Group PROJECT NO: CGS2398 DRAWING NO: 2 FILE REF: 2398-002-d2 DRAWN BY: KH OFFICE: 4/5 Arunga Drive, Beresfield NSW 2322 DATE: 03 OCTOBER 2014 CHECKED BY: IDP SITE TB016 NOTES: Drawing adapted from Parson Brinckerhoff (PB) construction plan reference '2118995A-1800-CIV-1802' revision 0 dated 30.10.2013 TB015 LEGEND: Approximate test pit locations and numbers TB014 TB017 TB019 TB013 TB022 TB020 TB021 TB018 TB012 TB037 DRAWING TITLE: PROJECT NAME: SITE LOCATION: TEST PIT LOCATION PLAN SITE CLASSIFICATION NORTHLAKES ESTATE STAGES 33 & 34, CAMERON PARK CLIENT: Northlakes Pty Ltd C/- McCloy Group PROJECT NO: CGS2398 DRAWING NO: 3 FILE REF: 2398-002-d3 DRAWN BY: KH OFFICE: 4/5 Arunga Drive, Beresfield NSW 2322 DATE: 03 OCTOBER 2014 CHECKED BY: IDP TB021 SITE TB037 TB026 TB011 TB036 NOTES: TB010 Drawing adapted from Parson Brinckerhoff (PB) construction plan reference '2118995A-1800-CIV-1802' revision 0 dated 30.10.2013 LEGEND: TB027 TB009 TB035 Approximate test pit locations and numbers TB028 TB008 TB007 TB029 TB006 DRAWING TITLE: PROJECT NAME: SITE LOCATION: TEST PIT LOCATION PLAN SITE CLASSIFICATION NORTHLAKES ESTATE STAGES 33 & 34, CAMERON PARK CLIENT: Northlakes Pty Ltd C/- McCloy Group PROJECT NO: CGS2398 DRAWING NO: 4 FILE REF: 2398-002-d4 DRAWN BY: KH OFFICE: 4/5 Arunga Drive, Beresfield NSW 2322 DATE: 03 OCTOBER 2014 CHECKED BY: IDP Report on Site ClassificationCGS2398-002/0 Northlakes Estate Stage 33 & 34, Cameron Park Prepared for Northlakes Pty Ltd C/- McCloy Group Pty Ltd APPENDIX B ENGINEERING LOGS CGS2398-002.0 October 2014 Cardno Geotech Solutions 11 Explanatory Notes The methods of description and classification of soils and rocks used in this report are based on Australian Standard 1726 Geotechnical Site Investigations Code. Material descriptions are deduced from field observation or engineering examination, and may be appended or confirmed by in situ or laboratory testing. The information is dependent on the scope of investigation, the extent of sampling and testing, and the inherent variability of the conditions encountered. Subsurface investigation may be conducted by one or a combination of the following methods. Field testing may be conducted as a means of assessment of the in-situ conditions of materials encountered. Method Field testing Test Pitting: excavation/trench BH Backhoe bucket SPT Standard Penetration Test (blows/150mm) HP/PP Hand/Pocket Penetrometer EX Excavator bucket X Existing excavation Dynamic Penetrometers (blows/150mm) Natural Exposure: existing natural rock or soil exposure Manual drilling: hand operated tools HA Hand Auger Continuous sample drilling PT Push tube Hammer drilling AH Air hammer AT Air track Spiral flight auger drilling AS AD/V Large diameter short spiral auger Continuous spiral flight auger: V-Bit AD/T Continuous spiral flight auger: TC-Bit Washbore (mud drilling) RR Rock roller 63mm diamond-tipped core barrel 52mm diamond-tipped core barrel NQ 47mm diamond-tipped core barrel Concrete coring DT Diatube Sampling is conducted to facilitate further assessment of selected materials encountered. Sampling method Disturbed sampling B Bulk disturbed sample D Disturbed sample ES Environmental soil sample Undisturbed sampling SPT Standard Penetration Test sample U# Undisturbed tube sample (#mm diameter) Water samples EW Environmental water sample Perth Sand Penetrometer Vane Shear PBT Plate Bearing Test If encountered with SPT or dynamic penetrometer testing, refusal (R), virtual refusal (VR) or hammer bouncing (HB) may be noted. The quality of the rock can be assessed be the degree of fracturing and the following. Rock quality description TCR RQD Rotary core drilling HQ NMLC Dynamic Cone Penetrometer PSP VS Rotary non-core drilling WS DCP Total Core Recovery (%) (length of core recovered divided by the length of core run) Rock Quality Designation (%) (sum of axial lengths of core greater than 100mm long divided by the length of core run) Notes on groundwater conditions encountered may include. Groundwater Not Encountered Excavation is dry in the short term Not Observed Groundwater observation not possible Seepage Groundwater seeping into hole Inflow Groundwater flowing/flooding into hole Perched groundwater may result in a misleading indication of the depth to the true water table. Groundwater levels are likely to fluctuate with variations in climatic and site conditions. Notes on the stability of excavations may include. Excavation conditions Spalling Unstable Material falling into excavation, may be described as minor or major spalling Collapse of the majority, or one or more face, of the excavation Explanatory Notes - General Soil Description The methods of description and classification of soils used in this report are based on Australian Standard 1726 Geotechnical Site Investigations Code. In practice, if the material can be remoulded by hand in its field condition or in water it is described as a soil. The dominant soil constituent is given in capital letters, with secondary textures in lower case. In general, descriptions cover: soil type, strength / relative density, moisture, colour, plasticity and inclusions. Soil types are described according to the dominant particle size on the basis of the following assessment. The moisture condition of soil is described by appearance and feel and may be described in relation to the Plastic Limit (PL) or Optimum Moisture Content (OMC). Soil Classification Particle Size CLAY < 0.002mm Moisture condition and description SILT 0.002mm 0.075mm Dry SAND GRAVEL fine 0.075mm to 0.2mm medium 0.2mm to 0.6mm coarse 0.6mm to 2.36mm fine 2.36mm to 6mm medium 6mm to 20mm coarse 20mm to 63mm COBBLES 63mm to 200mm BOULDERS > 200mm Soil types are qualified by the presence of minor components on the basis of field examination or grading. Description Percentage of minor component Trace < 5% in coarse grained soils < 15% in fine grained soils With 5% to 12% in coarse grained soils 15% to 30% in fine grained soils The strength of cohesive soils is classified by engineering assessment or field/laboratory testing as follows. Strength Symbol Undrained shear strength Very Soft VS < 12kPa Soft S 12kPa to 25kPa Firm F 25kPa to 50kPa Stiff St 50kPa to 100kPa Very Stiff VSt 100kPa to 200kPa Hard H > 200kPa Cohesionless soils are classified on the basis of relative density as follows. Moist Wet Cohesive soils; hard, friable, dry of plastic limit. Granular soils; cohesionless and free-running Cool feel and darkened colour: Cohesive soils can be moulded. Granular soils tend to cohere Cool feel and darkened colour: Cohesive soils usually weakened and free water forms when handling. Granular soils tend to cohere The plasticity of cohesive soils is defined as follows. Plasticity Liquid Limit Low plasticity ≤ 35% Medium plasticity > 35% ≤ 50% High plasticity > 50% The structure of the soil may be described as follows. Zoning Description Layer Continuous across exposure or sample Lens Discontinuous layer (lenticular shape) Pocket Irregular inclusion of different material The structure may include; defects such as softened zones, fissures, cracks, joints and root-holes; and coarse grained soils may be described as strongly or weakly cemented. The soil origin may also be noted if possible to deduce. Soil origin and description Fill Man-made deposits or disturbed material Topsoil Material affected by roots and root fibres Colluvial soil Transported down slopes by gravity Aeolian soil Transported and deposited by wind Alluvial soil Deposited by rivers Lacustrine soil Deposited by lakes Relative Density Symbol Density Index Marine soil Deposits in beaches, bays, estuaries Very Loose VL < 15% Residual soil Developed on weathered rock Loose L 15% to 35% Medium Dense MD 35% to 65% Dense D 65% to 85% Very Dense VD > 85% The origin of the soil generally cannot be deduced on the appearance of the material and may be assumed based on further geological evidence or field observation. Explanatory Notes - General Rock Description The methods of description and classification of rocks used in this report are based on Australian Standard 1726 Geotechnical Site Investigations Code. In general, if a material cannot be remoulded by hand in its field condition or in water it is described as a rock, is classified by its geological terms. In general, descriptions cover: rock type, degree of weathering, strength, colour, grain size, structure and minor components or inclusions. Sedimentary rock types are generally described according to the predominant grain size as follows. The defect spacing and bedding thickness of rocks, measured normal to defects of the same set or bedding, can be described as follows. Rock Type Description CONGLOMERATE Rounded gravel sized fragments >2mm cemented in a finer matrix Definition Defect Spacing Thinly laminated < 6mm SANDSTONE Sand size particles defined by grain size and often cemented by other materials fine 0.06mm to 0.2mm medium 0.2mm to 0.6mm coarse 0.6mm to 2mm Laminated 6mm to 20mm Very thinly bedded 20mm to 60mm Thinly bedded 60mm to 0.2m Medium bedded 0.2m to 0.6m SILTSTONE Predominately silt sized particles Thickly bedded 0.6m to 2m SHALE Fine particles (silt or clay) and fissile Very thickly bedded > 2m CLAYSTONE Predominately clay sized particles Defects in rock mass are often described by the following. The classification of rock weathering is described based on definitions outlined in AS1726 as follows. Terms Joint JT Sheared zone SZ Term and symbol Definition Bed Parting BP Sheared surface SS Residual Soil Soil developed on extremely weathered rock; mass structure and substance are no longer evident Weathered to such an extent that it has ‘soil’ properties Strength usually changed and may be highly discoloured. Porosity may be increased by leaching, or decreased due to deposition in pores Slightly discoloured; little/no change of strength from fresh rock Rock shows no sign of decomposition or staining Contact CO Seam SM Dyke DK Crushed Seam CS Decomposed Zone DZ Infilled Seam IS Fracture FC Foliation FL Fracture Zone FZ Vein VN Extremely weathered Distinctly weathered Slightly weathered Fresh Rock RS XW DW SW FR Rock material strength (distinct from mass strength which can be significantly weaker due to the effect of defects) can be defined based on the point load index as follows. Term and symbol Point Load Index Is50 Extremely low EL < 0.03MPa Very Low VL 0.03MPa to 0.1MPa Low L 0.1MPa to 0.3MPa Medium M 0.3MPa to 1MPa High H 1MPa to 3MPa Very High VH 3MPa to 10MPa Extremely High EH > 10MPa For preliminary assessment and in cases where no point load testing is available, the rock strength may be assessed using the field guide specified by AS1726. The shape and roughness of defects are described using the following terms. Planarity Roughness Planar PR Very Rough VR Curved CU Rough RF Undulating U Smooth S Irregular IR Polished POL Stepped ST Slickensides SL The coating or infill associated with defects can be described as follows. Definition Description Clean No visible coating or infilling Stain No visible coating or infilling; surfaces discoloured by mineral staining Visible coating or infilling of soil or mineral substance (<1mm). If discontinuous over the plane; patchy veneer Visible coating or infilling of soil or mineral substance (>1mm) Veneer Coating Graphics Symbols Index CLAYS GRAVELS SEDIMENTARY ROCK CLAY GRAVEL CONGLOMERATE Silty CLAY Clayey GRAVEL BRECCIA Sandy CLAY Silty GRAVEL SANDSTONE Gravelly CLAY Sandy GRAVEL STONE SILTSTONE COBBLES & BOULDERS SHALE SILTS MUDSTONE / CLAYSTONE Organic SILT COAL SILT MISCELLANEOUS Clayey SILT Sandy SILT Gravelly SILT SANDS FILL TOPSOIL CONCRETE ASPHALT METAMORPHIC ROCK SLATE / PHYLLITE / SCHIST GNEISS QUARTZITE SAND CORE LOSS Clayey SAND PAVEMENT GRAVEL GRANITE Silty SAND PAVEMENT (Natural Gravels) BASALT Gravelly SAND PAVEMENT (Crushed Rock) TUFF IGNEOUS ROCK CLIENT : Northlakes Pty Ltd C/- McCloy Group PROJECT : Site Classification LOCATION : Stage 33 & 34, Northlakes Estate, Cameron Park TESTBORE LOG HOLE NO : TB001 PROJECT REF : CGS2398 SHEET : 1 OF 1 EQUIPMENT TYPE : 5.5t Excavator METHOD : 300 mm Hydraulic Auger DATE EXCAVATED : 9/9/14 LOGGED BY : BB CHECKED BY : M-W STRUCTURE & Other Observations 400 HAND PENETROMETER (kPa) 300 200 100 DYNAMIC PENETROMETER CONSISTENCY / REL DENSITY / ROCK STRENGTH MOISTURE / FILL, Silty SAND, fine to coarse grained, brown, with clay & organics (topsoil fill) WEATHERING MATERIAL DESCRIPTION Soil Type, plasticity or particle characteristic, colour Rock Type, grain size, colour Secondary and minor components SYMBOL CLASSIFICATION GRAPHIC LOG DEPTH (m) SAMPLES & FIELD TESTS 0.0 Not Encountered GROUND WATER LEVELS LOCATION : See Drawing for location 3 0.10m SANDSTONE, fine to medium grained, pale orange-yellow XW 6 R EL - VL 0.30m Testbore TB001 terminated at 0.30 m Virtual refusal on weathered sandstone 0.5 GEOTECH_SOLUTIONS_03 LIBRARY.GLB Log CGS_TESTHOLE_LOG_02 CGS_2398_ NORTHLAKES ESTATE STAGES 33 & 34.GPJ 10/10/2014 14:06 8.30.003 1.0 1.5 2.0 2.5 WATER / MOISTURE SAMPLES & FIELD TESTS CONSISTENCY RELATIVE DENSITY ROCK STRENGTH ROCK WEATHERING D M W OMC PL U D ES B SPT HP VS S F St VSt H VL L MD D VD EL VL L M H VH EH RS XW DW SW FR - Dry Moist Wet Optimum MC Plastic Limit Water inflow See Explanatory Notes for details of abbreviations & basis of descriptions. - Undisturbed Sample Disturbed Sample Environmental sample Bulk Disturbed Sample Standard Penetration Test Hand/Pocket Penetrometer - Very Soft Soft Firm Stiff Very Stiff Hard - Very Loose Loose Medium Dense Dense Very Dense - Extremely low Very low Low Medium High Very high Extremely high - Residual soil Extremely weathered Distinctly weathered Slightly weathered Fresh rock CARDNO GEOTECH SOLUTIONS File: CGS2398 TB001 Page 1 OF 1 CLIENT : Northlakes Pty Ltd C/- McCloy Group PROJECT : Site Classification LOCATION : Stage 33 & 34, Northlakes Estate, Cameron Park TESTBORE LOG HOLE NO : TB002 PROJECT REF : CGS2398 SHEET : 1 OF 1 EQUIPMENT TYPE : 5.5t Excavator METHOD : 300 mm Hydraulic Auger DATE EXCAVATED : 9/9/14 LOGGED BY : BB CHECKED BY : STRUCTURE & Other Observations 400 HAND PENETROMETER (kPa) 300 200 100 DYNAMIC PENETROMETER MOISTURE / FILL, Silty SAND, fine to coarse grained, dark brown, with gravel, trace sand (topsoil fill) WEATHERING SYMBOL MATERIAL DESCRIPTION Soil Type, plasticity or particle characteristic, colour Rock Type, grain size, colour Secondary and minor components CONSISTENCY / REL DENSITY / ROCK STRENGTH 0.0 CLASSIFICATION GRAPHIC LOG DEPTH (m) SAMPLES & FIELD TESTS GROUND WATER LEVELS LOCATION : See Drawing for location M-W 0.15m Not Encountered Sandy CLAY, low plasticity, pale brown-orange MC > PL VSt - H 0.5 0.60m Testbore TB002 terminated at 0.60 m Virtual refusal on weathered sandstone GEOTECH_SOLUTIONS_03 LIBRARY.GLB Log CGS_TESTHOLE_LOG_02 CGS_2398_ NORTHLAKES ESTATE STAGES 33 & 34.GPJ 10/10/2014 14:06 8.30.003 1.0 1.5 2.0 2.5 WATER / MOISTURE SAMPLES & FIELD TESTS CONSISTENCY RELATIVE DENSITY ROCK STRENGTH ROCK WEATHERING D M W OMC PL U D ES B SPT HP VS S F St VSt H VL L MD D VD EL VL L M H VH EH RS XW DW SW FR - Dry Moist Wet Optimum MC Plastic Limit Water inflow See Explanatory Notes for details of abbreviations & basis of descriptions. - Undisturbed Sample Disturbed Sample Environmental sample Bulk Disturbed Sample Standard Penetration Test Hand/Pocket Penetrometer - Very Soft Soft Firm Stiff Very Stiff Hard - Very Loose Loose Medium Dense Dense Very Dense - Extremely low Very low Low Medium High Very high Extremely high - Residual soil Extremely weathered Distinctly weathered Slightly weathered Fresh rock CARDNO GEOTECH SOLUTIONS File: CGS2398 TB002 Page 1 OF 1 CLIENT : Northlakes Pty Ltd C/- McCloy Group PROJECT : Site Classification LOCATION : Stage 33 & 34, Northlakes Estate, Cameron Park TESTBORE LOG HOLE NO : TB003 PROJECT REF : CGS2398 SHEET : 1 OF 1 EQUIPMENT TYPE : 5.5t Excavator METHOD : 300 mm Hydraulic Auger DATE EXCAVATED : 9/9/14 LOGGED BY : BB CHECKED BY : STRUCTURE & Other Observations 400 HAND PENETROMETER (kPa) 300 200 100 DYNAMIC PENETROMETER CONSISTENCY / REL DENSITY / ROCK STRENGTH MOISTURE / WEATHERING MATERIAL DESCRIPTION Soil Type, plasticity or particle characteristic, colour Rock Type, grain size, colour Secondary and minor components SYMBOL CLASSIFICATION GRAPHIC LOG DEPTH (m) SAMPLES & FIELD TESTS 0.0 FILL, Silty SAND, fine to coarse grained, dark brown, trace clay, trace organics, trace gravel (topsoil fill) Not Encountered GROUND WATER LEVELS LOCATION : See Drawing for location M 0.20m SANDSTONE, fine to medium grained, pale brown-orange XW EL - VL 0.40m Testbore TB003 terminated at 0.40 m Virtual refusal 0.5 on weathered sandstone GEOTECH_SOLUTIONS_03 LIBRARY.GLB Log CGS_TESTHOLE_LOG_02 CGS_2398_ NORTHLAKES ESTATE STAGES 33 & 34.GPJ 10/10/2014 14:06 8.30.003 1.0 1.5 2.0 2.5 WATER / MOISTURE SAMPLES & FIELD TESTS CONSISTENCY RELATIVE DENSITY ROCK STRENGTH ROCK WEATHERING D M W OMC PL U D ES B SPT HP VS S F St VSt H VL L MD D VD EL VL L M H VH EH RS XW DW SW FR - Dry Moist Wet Optimum MC Plastic Limit Water inflow See Explanatory Notes for details of abbreviations & basis of descriptions. - Undisturbed Sample Disturbed Sample Environmental sample Bulk Disturbed Sample Standard Penetration Test Hand/Pocket Penetrometer - Very Soft Soft Firm Stiff Very Stiff Hard - Very Loose Loose Medium Dense Dense Very Dense - Extremely low Very low Low Medium High Very high Extremely high - Residual soil Extremely weathered Distinctly weathered Slightly weathered Fresh rock CARDNO GEOTECH SOLUTIONS File: CGS2398 TB003 Page 1 OF 1 CLIENT : Northlakes Pty Ltd C/- McCloy Group PROJECT : Site Classification LOCATION : Stage 33 & 34, Northlakes Estate, Cameron Park TESTBORE LOG HOLE NO : TB004 PROJECT REF : CGS2398 SHEET : 1 OF 1 EQUIPMENT TYPE : 5.5t Excavator METHOD : 300 mm Hydraulic Auger DATE EXCAVATED : 9/9/14 LOGGED BY : BB CHECKED BY : STRUCTURE & Other Observations 400 HAND PENETROMETER (kPa) 300 200 100 DYNAMIC PENETROMETER MOISTURE / WEATHERING SYMBOL MATERIAL DESCRIPTION Soil Type, plasticity or particle characteristic, colour Rock Type, grain size, colour Secondary and minor components CONSISTENCY / REL DENSITY / ROCK STRENGTH 0.0 CLASSIFICATION GRAPHIC LOG DEPTH (m) SAMPLES & FIELD TESTS GROUND WATER LEVELS LOCATION : See Drawing for location FILL, Silty SAND, fine to coarse grained, trace clay, trace organics M-W 9 0.20m SANDSTONE, fine to medium grained, pale yellow-orange 6 Not Encountered R 0.5 XW EL 0.80m Testbore TB004 terminated at 0.80 m Virtual refusal on weathered sandstone GEOTECH_SOLUTIONS_03 LIBRARY.GLB Log CGS_TESTHOLE_LOG_02 CGS_2398_ NORTHLAKES ESTATE STAGES 33 & 34.GPJ 10/10/2014 14:07 8.30.003 1.0 1.5 2.0 2.5 WATER / MOISTURE SAMPLES & FIELD TESTS CONSISTENCY RELATIVE DENSITY ROCK STRENGTH ROCK WEATHERING D M W OMC PL U D ES B SPT HP VS S F St VSt H VL L MD D VD EL VL L M H VH EH RS XW DW SW FR - Dry Moist Wet Optimum MC Plastic Limit Water inflow See Explanatory Notes for details of abbreviations & basis of descriptions. - Undisturbed Sample Disturbed Sample Environmental sample Bulk Disturbed Sample Standard Penetration Test Hand/Pocket Penetrometer - Very Soft Soft Firm Stiff Very Stiff Hard - Very Loose Loose Medium Dense Dense Very Dense - Extremely low Very low Low Medium High Very high Extremely high - Residual soil Extremely weathered Distinctly weathered Slightly weathered Fresh rock CARDNO GEOTECH SOLUTIONS File: CGS2398 TB004 Page 1 OF 1 CLIENT : Northlakes Pty Ltd C/- McCloy Group PROJECT : Site Classification LOCATION : Stage 33 & 34, Northlakes Estate, Cameron Park TESTBORE LOG HOLE NO : TB005 PROJECT REF : CGS2398 SHEET : 1 OF 1 EQUIPMENT TYPE : 5.5t Excavator METHOD : 300 mm Hydraulic Auger DATE EXCAVATED : 9/9/14 LOGGED BY : BB CHECKED BY : 0.05m STRUCTURE & Other Observations 400 HAND PENETROMETER (kPa) 300 200 100 DYNAMIC PENETROMETER MOISTURE / FILL, Silty SAND, fine to medium grained WEATHERING SYMBOL MATERIAL DESCRIPTION Soil Type, plasticity or particle characteristic, colour Rock Type, grain size, colour Secondary and minor components CONSISTENCY / REL DENSITY / ROCK STRENGTH 0.0 CLASSIFICATION GRAPHIC LOG DEPTH (m) SAMPLES & FIELD TESTS GROUND WATER LEVELS LOCATION : See Drawing for location M Not Encountered FILL, Silty CLAY, high plasticity, pale brown-grey, trace sand, gravel & cobbles 0.20m U50 MC > PL 0.35m 0.50m 0.5 0.55m SANDSTONE, fine to medium grained, pale orange-yellow XW VL Testbore TB005 terminated at 0.55 m Virtual refusal on weathered sandstone GEOTECH_SOLUTIONS_03 LIBRARY.GLB Log CGS_TESTHOLE_LOG_02 CGS_2398_ NORTHLAKES ESTATE STAGES 33 & 34.GPJ 10/10/2014 14:07 8.30.003 1.0 1.5 2.0 2.5 WATER / MOISTURE SAMPLES & FIELD TESTS CONSISTENCY RELATIVE DENSITY ROCK STRENGTH ROCK WEATHERING D M W OMC PL U D ES B SPT HP VS S F St VSt H VL L MD D VD EL VL L M H VH EH RS XW DW SW FR - Dry Moist Wet Optimum MC Plastic Limit Water inflow See Explanatory Notes for details of abbreviations & basis of descriptions. - Undisturbed Sample Disturbed Sample Environmental sample Bulk Disturbed Sample Standard Penetration Test Hand/Pocket Penetrometer - Very Soft Soft Firm Stiff Very Stiff Hard - Very Loose Loose Medium Dense Dense Very Dense - Extremely low Very low Low Medium High Very high Extremely high - Residual soil Extremely weathered Distinctly weathered Slightly weathered Fresh rock CARDNO GEOTECH SOLUTIONS File: CGS2398 TB005 Page 1 OF 1 CLIENT : Northlakes Pty Ltd C/- McCloy Group PROJECT : Site Classification LOCATION : Stage 33 & 34, Northlakes Estate, Cameron Park TESTBORE LOG HOLE NO : TB006 PROJECT REF : CGS2398 SHEET : 1 OF 1 EQUIPMENT TYPE : 5.5t Excavator METHOD : 300 mm Hydraulic Auger DATE EXCAVATED : 9/9/14 LOGGED BY : BB CHECKED BY : FILL, Silty SAND, fine to coarse grained, dark brown, with clay, trace gravel, trace organics (topsoil fill) STRUCTURE & Other Observations 400 HAND PENETROMETER (kPa) 300 200 100 DYNAMIC PENETROMETER MOISTURE / WEATHERING SYMBOL MATERIAL DESCRIPTION Soil Type, plasticity or particle characteristic, colour Rock Type, grain size, colour Secondary and minor components CONSISTENCY / REL DENSITY / ROCK STRENGTH 0.0 CLASSIFICATION GRAPHIC LOG DEPTH (m) GROUND WATER LEVELS SAMPLES & FIELD TESTS LOCATION : See Drawing for location 2 M-W 3 Not Encountered 0.25m FILL, Sandy Gravelly CLAY, low to medium plasticity, brown-orange 0.30m D 9 R 0.5 MC > PL 0.60m 0.80m Testbore TB006 terminated at 0.80 m Virtual refusal on weathered sandstone GEOTECH_SOLUTIONS_03 LIBRARY.GLB Log CGS_TESTHOLE_LOG_02 CGS_2398_ NORTHLAKES ESTATE STAGES 33 & 34.GPJ 10/10/2014 14:07 8.30.003 1.0 1.5 2.0 2.5 WATER / MOISTURE SAMPLES & FIELD TESTS CONSISTENCY RELATIVE DENSITY ROCK STRENGTH ROCK WEATHERING D M W OMC PL U D ES B SPT HP VS S F St VSt H VL L MD D VD EL VL L M H VH EH RS XW DW SW FR - Dry Moist Wet Optimum MC Plastic Limit Water inflow See Explanatory Notes for details of abbreviations & basis of descriptions. - Undisturbed Sample Disturbed Sample Environmental sample Bulk Disturbed Sample Standard Penetration Test Hand/Pocket Penetrometer - Very Soft Soft Firm Stiff Very Stiff Hard - Very Loose Loose Medium Dense Dense Very Dense - Extremely low Very low Low Medium High Very high Extremely high - Residual soil Extremely weathered Distinctly weathered Slightly weathered Fresh rock CARDNO GEOTECH SOLUTIONS File: CGS2398 TB006 Page 1 OF 1 CLIENT : Northlakes Pty Ltd C/- McCloy Group PROJECT : Site Classification LOCATION : Stage 33 & 34, Northlakes Estate, Cameron Park TESTBORE LOG HOLE NO : TB007 PROJECT REF : CGS2398 SHEET : 1 OF 1 EQUIPMENT TYPE : 5.5t Excavator METHOD : 300 mm Hydraulic Auger DATE EXCAVATED : 9/9/14 LOGGED BY : BB CHECKED BY : FILL, Gravelly SAND, fine to coarse grained, dark brown, with silt & organics (topsoil fill) STRUCTURE & Other Observations 400 HAND PENETROMETER (kPa) 300 200 100 DYNAMIC PENETROMETER MOISTURE / WEATHERING SYMBOL MATERIAL DESCRIPTION Soil Type, plasticity or particle characteristic, colour Rock Type, grain size, colour Secondary and minor components CONSISTENCY / REL DENSITY / ROCK STRENGTH 0.0 CLASSIFICATION GRAPHIC LOG DEPTH (m) SAMPLES & FIELD TESTS GROUND WATER LEVELS LOCATION : See Drawing for location 1 M-W 2 0.25m FILL, Silty CLAY, medium to high plasticity, with sand & gravel Not Encountered 6 0.5 MC > PL 7 8 0.80m Silty CLAY, medium plasticity, pale grey mottled orange, with sand, trace roots 12 MC > PL St 10 1.00m 1.0 R Sandy CLAY, low plasticity, mottled orange & grey MC = PL VSt 1.20m GEOTECH_SOLUTIONS_03 LIBRARY.GLB Log CGS_TESTHOLE_LOG_02 CGS_2398_ NORTHLAKES ESTATE STAGES 33 & 34.GPJ 10/10/2014 14:07 8.30.003 Testbore TB007 terminated at 1.20 m Virtual refusal on weathered sandstone 1.5 2.0 2.5 WATER / MOISTURE SAMPLES & FIELD TESTS CONSISTENCY RELATIVE DENSITY ROCK STRENGTH ROCK WEATHERING D M W OMC PL U D ES B SPT HP VS S F St VSt H VL L MD D VD EL VL L M H VH EH RS XW DW SW FR - Dry Moist Wet Optimum MC Plastic Limit Water inflow See Explanatory Notes for details of abbreviations & basis of descriptions. - Undisturbed Sample Disturbed Sample Environmental sample Bulk Disturbed Sample Standard Penetration Test Hand/Pocket Penetrometer - Very Soft Soft Firm Stiff Very Stiff Hard - Very Loose Loose Medium Dense Dense Very Dense - Extremely low Very low Low Medium High Very high Extremely high - Residual soil Extremely weathered Distinctly weathered Slightly weathered Fresh rock CARDNO GEOTECH SOLUTIONS File: CGS2398 TB007 Page 1 OF 1 CLIENT : Northlakes Pty Ltd C/- McCloy Group PROJECT : Site Classification LOCATION : Stage 33 & 34, Northlakes Estate, Cameron Park TESTBORE LOG HOLE NO : TB008 PROJECT REF : CGS2398 SHEET : 1 OF 1 EQUIPMENT TYPE : 5.5t Excavator METHOD : 300 mm Hydraulic Auger DATE EXCAVATED : 9/9/14 LOGGED BY : BB CHECKED BY : STRUCTURE & Other Observations 400 HAND PENETROMETER (kPa) 300 200 100 DYNAMIC PENETROMETER MOISTURE / WEATHERING SYMBOL MATERIAL DESCRIPTION Soil Type, plasticity or particle characteristic, colour Rock Type, grain size, colour Secondary and minor components CONSISTENCY / REL DENSITY / ROCK STRENGTH 0.0 CLASSIFICATION GRAPHIC LOG DEPTH (m) SAMPLES & FIELD TESTS GROUND WATER LEVELS LOCATION : See Drawing for location FILL, Gravelly SAND, fine to coarse, pale brown-yellow, trace cobbles Not Encountered D-M 0.50m 0.5 Silty Sandy CLAY, medium plasticity, pale brown-grey mottled orange, trace roots HP In-situ > 500 kPa MC = PL H 0.80m Testbore TB008 terminated at 0.80 m Virtual refusal on weathered siltstone GEOTECH_SOLUTIONS_03 LIBRARY.GLB Log CGS_TESTHOLE_LOG_02 CGS_2398_ NORTHLAKES ESTATE STAGES 33 & 34.GPJ 10/10/2014 14:07 8.30.003 1.0 1.5 2.0 WATER / MOISTURE SAMPLES & FIELD TESTS CONSISTENCY RELATIVE DENSITY ROCK STRENGTH ROCK WEATHERING D M W OMC PL U D ES B SPT HP VS S F St VSt H VL L MD D VD EL VL L M H VH EH RS XW DW SW FR - Dry Moist Wet Optimum MC Plastic Limit Water inflow See Explanatory Notes for details of abbreviations & basis of descriptions. - Undisturbed Sample Disturbed Sample Environmental sample Bulk Disturbed Sample Standard Penetration Test Hand/Pocket Penetrometer - Very Soft Soft Firm Stiff Very Stiff Hard - Very Loose Loose Medium Dense Dense Very Dense - Extremely low Very low Low Medium High Very high Extremely high - Residual soil Extremely weathered Distinctly weathered Slightly weathered Fresh rock CARDNO GEOTECH SOLUTIONS File: CGS2398 TB008 Page 1 OF 1 CLIENT : Northlakes Pty Ltd C/- McCloy Group PROJECT : Site Classification LOCATION : Stage 33 & 34, Northlakes Estate, Cameron Park TESTBORE LOG HOLE NO : TB009 PROJECT REF : CGS2398 SHEET : 1 OF 1 EQUIPMENT TYPE : 5.5t Excavator METHOD : 300 mm Hydraulic Auger DATE EXCAVATED : 9/9/14 LOGGED BY : BB CHECKED BY : STRUCTURE & Other Observations 400 HAND PENETROMETER (kPa) 300 200 100 DYNAMIC PENETROMETER MOISTURE / WEATHERING SYMBOL MATERIAL DESCRIPTION Soil Type, plasticity or particle characteristic, colour Rock Type, grain size, colour Secondary and minor components CONSISTENCY / REL DENSITY / ROCK STRENGTH 0.0 CLASSIFICATION GRAPHIC LOG DEPTH (m) SAMPLES & FIELD TESTS GROUND WATER LEVELS LOCATION : See Drawing for location FILL, Silty CLAY, medium plasticity, brown, with sand & gravel, trace boulder (topsoil fill) 4 D-M 21 0.35m Not Encountered Silty Sandy CLAY, medium to high plasticity, pale grey-brown mottled orange, trace roots 9 0.5 4 MC > PL 7 10 0.90m SILTSTONE, grey XW 1.00m GEOTECH_SOLUTIONS_03 LIBRARY.GLB Log CGS_TESTHOLE_LOG_02 CGS_2398_ NORTHLAKES ESTATE STAGES 33 & 34.GPJ 10/10/2014 14:07 8.30.003 1.0 Testbore TB009 terminated at 1.00 m Virtual refusal on weathered siltstone 1.5 2.0 WATER / MOISTURE SAMPLES & FIELD TESTS CONSISTENCY RELATIVE DENSITY ROCK STRENGTH ROCK WEATHERING D M W OMC PL U D ES B SPT HP VS S F St VSt H VL L MD D VD EL VL L M H VH EH RS XW DW SW FR - Dry Moist Wet Optimum MC Plastic Limit Water inflow See Explanatory Notes for details of abbreviations & basis of descriptions. - Undisturbed Sample Disturbed Sample Environmental sample Bulk Disturbed Sample Standard Penetration Test Hand/Pocket Penetrometer - Very Soft Soft Firm Stiff Very Stiff Hard - Very Loose Loose Medium Dense Dense Very Dense - Extremely low Very low Low Medium High Very high Extremely high - Residual soil Extremely weathered Distinctly weathered Slightly weathered Fresh rock CARDNO GEOTECH SOLUTIONS File: CGS2398 TB009 Page 1 OF 1 CLIENT : Northlakes Pty Ltd C/- McCloy Group PROJECT : Site Classification LOCATION : Stage 33 & 34, Northlakes Estate, Cameron Park TESTBORE LOG HOLE NO : TB010 PROJECT REF : CGS2398 SHEET : 1 OF 1 EQUIPMENT TYPE : 5.5t Excavator METHOD : 300 mm Hydraulic Auger DATE EXCAVATED : 9/9/14 LOGGED BY : BB CHECKED BY : 0.05m 0.10m STRUCTURE & Other Observations 400 HAND PENETROMETER (kPa) 300 200 100 DYNAMIC PENETROMETER MOISTURE / FILL, Gravelly SAND, fine to coarse grained, pale brown-orange WEATHERING SYMBOL MATERIAL DESCRIPTION Soil Type, plasticity or particle characteristic, colour Rock Type, grain size, colour Secondary and minor components CONSISTENCY / REL DENSITY / ROCK STRENGTH 0.0 CLASSIFICATION GRAPHIC LOG DEPTH (m) SAMPLES & FIELD TESTS GROUND WATER LEVELS LOCATION : See Drawing for location M Silty Clayey SAND, fine to medium grained, brown, trace organics M-W Not Encountered Silty CLAY, medium to high plasticity, pale brown-grey mottled orange, trace roots 0.20m HP In-situ > 500 kPa U50 MC = PL H 0.5 HP In-situ > 500 kPa 0.57m 0.60m Testbore TB010 terminated at 0.60 m Virtual refusal on weathered siltstone GEOTECH_SOLUTIONS_03 LIBRARY.GLB Log CGS_TESTHOLE_LOG_02 CGS_2398_ NORTHLAKES ESTATE STAGES 33 & 34.GPJ 10/10/2014 14:07 8.30.003 1.0 1.5 2.0 WATER / MOISTURE SAMPLES & FIELD TESTS CONSISTENCY RELATIVE DENSITY ROCK STRENGTH ROCK WEATHERING D M W OMC PL U D ES B SPT HP VS S F St VSt H VL L MD D VD EL VL L M H VH EH RS XW DW SW FR - Dry Moist Wet Optimum MC Plastic Limit Water inflow See Explanatory Notes for details of abbreviations & basis of descriptions. - Undisturbed Sample Disturbed Sample Environmental sample Bulk Disturbed Sample Standard Penetration Test Hand/Pocket Penetrometer - Very Soft Soft Firm Stiff Very Stiff Hard - Very Loose Loose Medium Dense Dense Very Dense - Extremely low Very low Low Medium High Very high Extremely high - Residual soil Extremely weathered Distinctly weathered Slightly weathered Fresh rock CARDNO GEOTECH SOLUTIONS File: CGS2398 TB010 Page 1 OF 1 CLIENT : Northlakes Pty Ltd C/- McCloy Group PROJECT : Site Classification LOCATION : Stage 33 & 34, Northlakes Estate, Cameron Park TESTBORE LOG HOLE NO : TB011 PROJECT REF : CGS2398 SHEET : 1 OF 1 EQUIPMENT TYPE : 5.5t Excavator METHOD : 300 mm Hydraulic Auger DATE EXCAVATED : 9/9/14 LOGGED BY : BB CHECKED BY : STRUCTURE & Other Observations 400 HAND PENETROMETER (kPa) 300 200 100 DYNAMIC PENETROMETER CONSISTENCY / REL DENSITY / ROCK STRENGTH MOISTURE / FILL, Gravelly SAND, fine to coarse grained, dark brown, trace clay, trace organics (topsoil fill) WEATHERING MATERIAL DESCRIPTION Soil Type, plasticity or particle characteristic, colour Rock Type, grain size, colour Secondary and minor components SYMBOL CLASSIFICATION GRAPHIC LOG DEPTH (m) SAMPLES & FIELD TESTS 0.0 Not Encountered GROUND WATER LEVELS LOCATION : See Drawing for location M 0.10m SILTSTONE, pale grey-white XW EL - VL 0.25m Testbore TB011 terminated at 0.25 m Virtual refusal on weathered siltstone 0.5 GEOTECH_SOLUTIONS_03 LIBRARY.GLB Log CGS_TESTHOLE_LOG_02 CGS_2398_ NORTHLAKES ESTATE STAGES 33 & 34.GPJ 10/10/2014 14:07 8.30.003 1.0 1.5 2.0 WATER / MOISTURE SAMPLES & FIELD TESTS CONSISTENCY RELATIVE DENSITY ROCK STRENGTH ROCK WEATHERING D M W OMC PL U D ES B SPT HP VS S F St VSt H VL L MD D VD EL VL L M H VH EH RS XW DW SW FR - Dry Moist Wet Optimum MC Plastic Limit Water inflow See Explanatory Notes for details of abbreviations & basis of descriptions. - Undisturbed Sample Disturbed Sample Environmental sample Bulk Disturbed Sample Standard Penetration Test Hand/Pocket Penetrometer - Very Soft Soft Firm Stiff Very Stiff Hard - Very Loose Loose Medium Dense Dense Very Dense - Extremely low Very low Low Medium High Very high Extremely high - Residual soil Extremely weathered Distinctly weathered Slightly weathered Fresh rock CARDNO GEOTECH SOLUTIONS File: CGS2398 TB011 Page 1 OF 1 CLIENT : Northlakes Pty Ltd C/- McCloy Group PROJECT : Site Classification LOCATION : Stage 33 & 34, Northlakes Estate, Cameron Park TESTBORE LOG HOLE NO : TB012 PROJECT REF : CGS2398 SHEET : 1 OF 1 EQUIPMENT TYPE : 5.5t Excavator METHOD : 300 mm Hydraulic Auger DATE EXCAVATED : 9/9/14 LOGGED BY : BB CHECKED BY : STRUCTURE & Other Observations 400 HAND PENETROMETER (kPa) 300 200 100 DYNAMIC PENETROMETER MOISTURE / WEATHERING SYMBOL MATERIAL DESCRIPTION Soil Type, plasticity or particle characteristic, colour Rock Type, grain size, colour Secondary and minor components CONSISTENCY / REL DENSITY / ROCK STRENGTH 0.0 CLASSIFICATION GRAPHIC LOG DEPTH (m) GROUND WATER LEVELS SAMPLES & FIELD TESTS LOCATION : See Drawing for location FILL, Sandy CLAY, medium plasticity, dark brown, with silt & organics (topsoil fill) M 0.30m 0.30m D Silty CLAY, low to medium plasticity, pale yellow-grey Not Encountered MC > PL VSt HP In-situ = 300 kPa 0.40m 0.40m HP In-situ = 400 kPa Silty CLAY, low plasticity, dark brown-black (carbonaceous) 0.50m D 0.5 MC > PL H XW H HP In-situ = 500 kPa 0.65m SILTSTONE, pale yellow-grey 1.00m GEOTECH_SOLUTIONS_03 LIBRARY.GLB Log CGS_TESTHOLE_LOG_02 CGS_2398_ NORTHLAKES ESTATE STAGES 33 & 34.GPJ 10/10/2014 14:07 8.30.003 1.0 Testbore TB012 terminated at 1.00 m Virtual refusal on weathered siltstone 1.5 2.0 WATER / MOISTURE SAMPLES & FIELD TESTS CONSISTENCY RELATIVE DENSITY ROCK STRENGTH ROCK WEATHERING D M W OMC PL U D ES B SPT HP VS S F St VSt H VL L MD D VD EL VL L M H VH EH RS XW DW SW FR - Dry Moist Wet Optimum MC Plastic Limit Water inflow See Explanatory Notes for details of abbreviations & basis of descriptions. - Undisturbed Sample Disturbed Sample Environmental sample Bulk Disturbed Sample Standard Penetration Test Hand/Pocket Penetrometer - Very Soft Soft Firm Stiff Very Stiff Hard - Very Loose Loose Medium Dense Dense Very Dense - Extremely low Very low Low Medium High Very high Extremely high - Residual soil Extremely weathered Distinctly weathered Slightly weathered Fresh rock CARDNO GEOTECH SOLUTIONS File: CGS2398 TB012 Page 1 OF 1 CLIENT : Northlakes Pty Ltd C/- McCloy Group PROJECT : Site Classification LOCATION : Stage 33 & 34, Northlakes Estate, Cameron Park TESTBORE LOG HOLE NO : TB013 PROJECT REF : CGS2398 SHEET : 1 OF 1 EQUIPMENT TYPE : 5.5t Excavator METHOD : 300 mm Hydraulic Auger DATE EXCAVATED : 9/9/14 LOGGED BY : BB CHECKED BY : STRUCTURE & Other Observations 400 HAND PENETROMETER (kPa) 300 200 100 DYNAMIC PENETROMETER MOISTURE / WEATHERING SYMBOL MATERIAL DESCRIPTION Soil Type, plasticity or particle characteristic, colour Rock Type, grain size, colour Secondary and minor components CONSISTENCY / REL DENSITY / ROCK STRENGTH 0.0 CLASSIFICATION GRAPHIC LOG DEPTH (m) SAMPLES & FIELD TESTS GROUND WATER LEVELS LOCATION : See Drawing for location FILL, Sandy Silty CLAY, low plasticity, dark brown, with organics (topsoil fill) M-W 1 0.15m Silty CLAY, high plasticity, pale brown mottled red, trace sand 3 3 0.50m U50 0.5 5 MC > PL St 6 0.72m Not Encountered GEOTECH_SOLUTIONS_03 LIBRARY.GLB Log CGS_TESTHOLE_LOG_02 CGS_2398_ NORTHLAKES ESTATE STAGES 33 & 34.GPJ 10/10/2014 14:07 8.30.003 6 6 1.00m 1.0 Silty CLAY, low to medium plasticity, pale grey-white 7 11 MC > PL St - VSt 1.5 1.70m Silty CLAY, low plasticity, dark brown MC < PL H 2.00m 2.0 Testbore TB013 terminated at 2.00 m Target depth WATER / MOISTURE SAMPLES & FIELD TESTS CONSISTENCY RELATIVE DENSITY ROCK STRENGTH ROCK WEATHERING D M W OMC PL U D ES B SPT HP VS S F St VSt H VL L MD D VD EL VL L M H VH EH RS XW DW SW FR - Dry Moist Wet Optimum MC Plastic Limit Water inflow See Explanatory Notes for details of abbreviations & basis of descriptions. - Undisturbed Sample Disturbed Sample Environmental sample Bulk Disturbed Sample Standard Penetration Test Hand/Pocket Penetrometer - Very Soft Soft Firm Stiff Very Stiff Hard - Very Loose Loose Medium Dense Dense Very Dense - Extremely low Very low Low Medium High Very high Extremely high - Residual soil Extremely weathered Distinctly weathered Slightly weathered Fresh rock CARDNO GEOTECH SOLUTIONS File: CGS2398 TB013 Page 1 OF 1 CLIENT : Northlakes Pty Ltd C/- McCloy Group PROJECT : Site Classification LOCATION : Stage 33 & 34, Northlakes Estate, Cameron Park TESTBORE LOG HOLE NO : TB014 PROJECT REF : CGS2398 SHEET : 1 OF 1 EQUIPMENT TYPE : 5.5t Excavator METHOD : 300 mm Hydraulic Auger DATE EXCAVATED : 9/9/14 LOGGED BY : BB CHECKED BY : STRUCTURE & Other Observations 400 HAND PENETROMETER (kPa) 300 200 100 DYNAMIC PENETROMETER MOISTURE / WEATHERING SYMBOL MATERIAL DESCRIPTION Soil Type, plasticity or particle characteristic, colour Rock Type, grain size, colour Secondary and minor components CONSISTENCY / REL DENSITY / ROCK STRENGTH 0.0 CLASSIFICATION GRAPHIC LOG DEPTH (m) SAMPLES & FIELD TESTS GROUND WATER LEVELS LOCATION : See Drawing for location Silty SAND, fine to coarse grained, brown, with root fibres D-M 0.10m Silty CLAY, high plasticity, pale grey-brown mottled orange, trace roots HP In-situ = 250 kPa 0.5 Not Encountered GEOTECH_SOLUTIONS_03 LIBRARY.GLB Log CGS_TESTHOLE_LOG_02 CGS_2398_ NORTHLAKES ESTATE STAGES 33 & 34.GPJ 10/10/2014 14:07 8.30.003 MC > PL St - VSt HP In-situ = 350 kPa 1.0 1.10m Silty CLAY, medium plasticity, dark brown (carbonaceous) 1.5 MC = PL VSt 1.90m Silty CLAY, low plasticity, pale grey-white MC > PL VSt - H 2.00m 2.0 Testbore TB014 terminated at 2.00 m Target depth WATER / MOISTURE SAMPLES & FIELD TESTS CONSISTENCY RELATIVE DENSITY ROCK STRENGTH ROCK WEATHERING D M W OMC PL U D ES B SPT HP VS S F St VSt H VL L MD D VD EL VL L M H VH EH RS XW DW SW FR - Dry Moist Wet Optimum MC Plastic Limit Water inflow See Explanatory Notes for details of abbreviations & basis of descriptions. - Undisturbed Sample Disturbed Sample Environmental sample Bulk Disturbed Sample Standard Penetration Test Hand/Pocket Penetrometer - Very Soft Soft Firm Stiff Very Stiff Hard - Very Loose Loose Medium Dense Dense Very Dense - Extremely low Very low Low Medium High Very high Extremely high - Residual soil Extremely weathered Distinctly weathered Slightly weathered Fresh rock CARDNO GEOTECH SOLUTIONS File: CGS2398 TB014 Page 1 OF 1 CLIENT : Northlakes Pty Ltd C/- McCloy Group PROJECT : Site Classification LOCATION : Stage 33 & 34, Northlakes Estate, Cameron Park TESTBORE LOG HOLE NO : TB015 PROJECT REF : CGS2398 SHEET : 1 OF 1 EQUIPMENT TYPE : 5.5t Excavator METHOD : 300 mm Hydraulic Auger DATE EXCAVATED : 9/9/14 LOGGED BY : BB CHECKED BY : STRUCTURE & Other Observations 400 HAND PENETROMETER (kPa) 300 200 100 DYNAMIC PENETROMETER MOISTURE / WEATHERING SYMBOL MATERIAL DESCRIPTION Soil Type, plasticity or particle characteristic, colour Rock Type, grain size, colour Secondary and minor components CONSISTENCY / REL DENSITY / ROCK STRENGTH 0.0 CLASSIFICATION GRAPHIC LOG DEPTH (m) SAMPLES & FIELD TESTS GROUND WATER LEVELS LOCATION : See Drawing for location TOPSOIL, Silty Sandy CLAY, low to medium plasticity, dark brown, with organics 5 M-W 0.20m Silty CLAY, medium to high plasticity 3 4 0.5 3 5 MC > PL St - VSt Not Encountered GEOTECH_SOLUTIONS_03 LIBRARY.GLB Log CGS_TESTHOLE_LOG_02 CGS_2398_ NORTHLAKES ESTATE STAGES 33 & 34.GPJ 10/10/2014 14:07 8.30.003 7 9 1.0 1.20m 1.20m U50 Silty CLAY, low plasticity, mottled pale brown & red 1.46m 1.5 MC = PL VSt - H 1.90m Silty CLAY, medium plasticity, pale yellow-white MC > PL H 2.00m 2.0 Testbore TB015 terminated at 2.00 m Target depth WATER / MOISTURE SAMPLES & FIELD TESTS CONSISTENCY RELATIVE DENSITY ROCK STRENGTH ROCK WEATHERING D M W OMC PL U D ES B SPT HP VS S F St VSt H VL L MD D VD EL VL L M H VH EH RS XW DW SW FR - Dry Moist Wet Optimum MC Plastic Limit Water inflow See Explanatory Notes for details of abbreviations & basis of descriptions. - Undisturbed Sample Disturbed Sample Environmental sample Bulk Disturbed Sample Standard Penetration Test Hand/Pocket Penetrometer - Very Soft Soft Firm Stiff Very Stiff Hard - Very Loose Loose Medium Dense Dense Very Dense - Extremely low Very low Low Medium High Very high Extremely high - Residual soil Extremely weathered Distinctly weathered Slightly weathered Fresh rock CARDNO GEOTECH SOLUTIONS File: CGS2398 TB015 Page 1 OF 1 CLIENT : Northlakes Pty Ltd C/- McCloy Group PROJECT : Site Classification LOCATION : Stage 33 & 34, Northlakes Estate, Cameron Park TESTBORE LOG HOLE NO : TB016 PROJECT REF : CGS2398 SHEET : 1 OF 1 EQUIPMENT TYPE : 5.5t Excavator METHOD : 300 mm Hydraulic Auger DATE EXCAVATED : 9/9/14 LOGGED BY : BB CHECKED BY : STRUCTURE & Other Observations 400 HAND PENETROMETER (kPa) 300 200 100 DYNAMIC PENETROMETER MOISTURE / WEATHERING SYMBOL MATERIAL DESCRIPTION Soil Type, plasticity or particle characteristic, colour Rock Type, grain size, colour Secondary and minor components CONSISTENCY / REL DENSITY / ROCK STRENGTH 0.0 CLASSIFICATION GRAPHIC LOG DEPTH (m) SAMPLES & FIELD TESTS GROUND WATER LEVELS LOCATION : See Drawing for location Silty CLAY, low plasticity, dark brown, with organics W 0.30m Silty CLAY, medium to high plasticity, orange-pale brown, trace sand Not Encountered F 0.50m D 0.5 MC > PL St - VSt 0.90m SILTSTONE, pale grey GEOTECH_SOLUTIONS_03 LIBRARY.GLB Log CGS_TESTHOLE_LOG_02 CGS_2398_ NORTHLAKES ESTATE STAGES 33 & 34.GPJ 10/10/2014 14:07 8.30.003 1.0 XW EL - L 1.20m Testbore TB016 terminated at 1.20 m Virtual refusal on weathered siltstone 1.5 2.0 WATER / MOISTURE SAMPLES & FIELD TESTS CONSISTENCY RELATIVE DENSITY ROCK STRENGTH ROCK WEATHERING D M W OMC PL U D ES B SPT HP VS S F St VSt H VL L MD D VD EL VL L M H VH EH RS XW DW SW FR - Dry Moist Wet Optimum MC Plastic Limit Water inflow See Explanatory Notes for details of abbreviations & basis of descriptions. - Undisturbed Sample Disturbed Sample Environmental sample Bulk Disturbed Sample Standard Penetration Test Hand/Pocket Penetrometer - Very Soft Soft Firm Stiff Very Stiff Hard - Very Loose Loose Medium Dense Dense Very Dense - Extremely low Very low Low Medium High Very high Extremely high - Residual soil Extremely weathered Distinctly weathered Slightly weathered Fresh rock CARDNO GEOTECH SOLUTIONS File: CGS2398 TB016 Page 1 OF 1 CLIENT : Northlakes Pty Ltd C/- McCloy Group PROJECT : Site Classification LOCATION : Stage 33 & 34, Northlakes Estate, Cameron Park TESTBORE LOG HOLE NO : TB017 PROJECT REF : CGS2398 SHEET : 1 OF 1 EQUIPMENT TYPE : 5.5t Excavator METHOD : 300 mm Hydraulic Auger DATE EXCAVATED : 9/9/14 LOGGED BY : BB CHECKED BY : STRUCTURE & Other Observations 400 HAND PENETROMETER (kPa) 300 200 100 DYNAMIC PENETROMETER MOISTURE / TOPSOIL, Silty CLAY, medium plasticity, dark brown-grey, trace root fibres & gravel WEATHERING SYMBOL MATERIAL DESCRIPTION Soil Type, plasticity or particle characteristic, colour Rock Type, grain size, colour Secondary and minor components CONSISTENCY / REL DENSITY / ROCK STRENGTH 0.0 CLASSIFICATION GRAPHIC LOG DEPTH (m) GROUND WATER LEVELS SAMPLES & FIELD TESTS LOCATION : See Drawing for location M-W 0.10m Silty CLAY, high plasticity, grey-brown mottled orange, trace root fibres MC > PL St 0.5 0.80m Not Encountered GEOTECH_SOLUTIONS_03 LIBRARY.GLB Log CGS_TESTHOLE_LOG_02 CGS_2398_ NORTHLAKES ESTATE STAGES 33 & 34.GPJ 10/10/2014 14:07 8.30.003 Silty CLAY, low plasticity, grey-brown, interbedded carbonaceous layers 1.00m B 1.0 1.30m MC > PL St - VSt 1.5 1.80m Silty CLAY, low to medium plasticity, pale grey-white (borderline xw siltstone) MC < PL H 2.00m 2.0 Testbore TB017 terminated at 2.00 m Target depth WATER / MOISTURE SAMPLES & FIELD TESTS CONSISTENCY RELATIVE DENSITY ROCK STRENGTH ROCK WEATHERING D M W OMC PL U D ES B SPT HP VS S F St VSt H VL L MD D VD EL VL L M H VH EH RS XW DW SW FR - Dry Moist Wet Optimum MC Plastic Limit Water inflow See Explanatory Notes for details of abbreviations & basis of descriptions. - Undisturbed Sample Disturbed Sample Environmental sample Bulk Disturbed Sample Standard Penetration Test Hand/Pocket Penetrometer - Very Soft Soft Firm Stiff Very Stiff Hard - Very Loose Loose Medium Dense Dense Very Dense - Extremely low Very low Low Medium High Very high Extremely high - Residual soil Extremely weathered Distinctly weathered Slightly weathered Fresh rock CARDNO GEOTECH SOLUTIONS File: CGS2398 TB017 Page 1 OF 1 CLIENT : Northlakes Pty Ltd C/- McCloy Group PROJECT : Site Classification LOCATION : Stage 33 & 34, Northlakes Estate, Cameron Park TESTBORE LOG HOLE NO : TB018 PROJECT REF : CGS2398 SHEET : 1 OF 1 EQUIPMENT TYPE : 5.5t Excavator METHOD : 300 mm Hydraulic Auger DATE EXCAVATED : 9/9/14 LOGGED BY : BB CHECKED BY : STRUCTURE & Other Observations 400 HAND PENETROMETER (kPa) 300 200 100 DYNAMIC PENETROMETER MOISTURE / WEATHERING SYMBOL MATERIAL DESCRIPTION Soil Type, plasticity or particle characteristic, colour Rock Type, grain size, colour Secondary and minor components CONSISTENCY / REL DENSITY / ROCK STRENGTH 0.0 CLASSIFICATION GRAPHIC LOG DEPTH (m) SAMPLES & FIELD TESTS GROUND WATER LEVELS LOCATION : See Drawing for location FILL, Silty Clayey SAND, fine to coarse grained, dark brown, with organics M-W 3 0.15m FILL, Gravelly CLAY, medium plasticity, with silt & sand 4 MC > PL St 4 0.40m Silty CLAY, medium to high plasticity, pale brown-grey mottled orange, trace sand 0.5 Not Encountered 10 10 MC > PL VSt 10 1.00m GEOTECH_SOLUTIONS_03 LIBRARY.GLB Log CGS_TESTHOLE_LOG_02 CGS_2398_ NORTHLAKES ESTATE STAGES 33 & 34.GPJ 10/10/2014 14:07 8.30.003 1.0 SILTSTONE, pale grey-brown XW EL - VL 1.30m Testbore TB018 terminated at 1.30 m Virtual refusal on weathered siltstone 1.5 2.0 WATER / MOISTURE SAMPLES & FIELD TESTS CONSISTENCY RELATIVE DENSITY ROCK STRENGTH ROCK WEATHERING D M W OMC PL U D ES B SPT HP VS S F St VSt H VL L MD D VD EL VL L M H VH EH RS XW DW SW FR - Dry Moist Wet Optimum MC Plastic Limit Water inflow See Explanatory Notes for details of abbreviations & basis of descriptions. - Undisturbed Sample Disturbed Sample Environmental sample Bulk Disturbed Sample Standard Penetration Test Hand/Pocket Penetrometer - Very Soft Soft Firm Stiff Very Stiff Hard - Very Loose Loose Medium Dense Dense Very Dense - Extremely low Very low Low Medium High Very high Extremely high - Residual soil Extremely weathered Distinctly weathered Slightly weathered Fresh rock CARDNO GEOTECH SOLUTIONS File: CGS2398 TB018 Page 1 OF 1 CLIENT : Northlakes Pty Ltd C/- McCloy Group PROJECT : Site Classification LOCATION : Stage 33 & 34, Northlakes Estate, Cameron Park TESTBORE LOG HOLE NO : TB019 PROJECT REF : CGS2398 SHEET : 1 OF 1 EQUIPMENT TYPE : 5.5t Excavator METHOD : 300 mm Hydraulic Auger DATE EXCAVATED : 9/9/14 LOGGED BY : BB CHECKED BY : STRUCTURE & Other Observations 400 HAND PENETROMETER (kPa) 300 200 100 DYNAMIC PENETROMETER MOISTURE / WEATHERING SYMBOL MATERIAL DESCRIPTION Soil Type, plasticity or particle characteristic, colour Rock Type, grain size, colour Secondary and minor components CONSISTENCY / REL DENSITY / ROCK STRENGTH 0.0 CLASSIFICATION GRAPHIC LOG DEPTH (m) SAMPLES & FIELD TESTS GROUND WATER LEVELS LOCATION : See Drawing for location TOPSOIL, Silty CLAY, low to medium plasticity, dark brown-black M-W 3 0.15m Silty CLAY, high plasticity, pale brown-grey mottled orange, trace sand, trace roots 5 4 0.50m U50 0.5 MC > PL St 5 6 0.70m 0.90m Not Encountered GEOTECH_SOLUTIONS_03 LIBRARY.GLB Log CGS_TESTHOLE_LOG_02 CGS_2398_ NORTHLAKES ESTATE STAGES 33 & 34.GPJ 10/10/2014 14:07 8.30.003 7 Silty CLAY, low to medium plasticity, mottled pale grey & yellow, trace rock fragments, trace roots 1.0 MC = PL VSt 1.5 1.60m Silty CLAY, low plasticity, dark brown (carbonaceous) MC > PL VSt - H 1.80m SILTSTONE, pale grey-white XW EL 2.00m 2.0 Testbore TB019 terminated at 2.00 m Target depth on weathered siltstone WATER / MOISTURE SAMPLES & FIELD TESTS CONSISTENCY RELATIVE DENSITY ROCK STRENGTH ROCK WEATHERING D M W OMC PL U D ES B SPT HP VS S F St VSt H VL L MD D VD EL VL L M H VH EH RS XW DW SW FR - Dry Moist Wet Optimum MC Plastic Limit Water inflow See Explanatory Notes for details of abbreviations & basis of descriptions. - Undisturbed Sample Disturbed Sample Environmental sample Bulk Disturbed Sample Standard Penetration Test Hand/Pocket Penetrometer - Very Soft Soft Firm Stiff Very Stiff Hard - Very Loose Loose Medium Dense Dense Very Dense - Extremely low Very low Low Medium High Very high Extremely high - Residual soil Extremely weathered Distinctly weathered Slightly weathered Fresh rock CARDNO GEOTECH SOLUTIONS File: CGS2398 TB019 Page 1 OF 1 CLIENT : Northlakes Pty Ltd C/- McCloy Group PROJECT : Site Classification LOCATION : Stage 33 & 34, Northlakes Estate, Cameron Park TESTBORE LOG HOLE NO : TB020 PROJECT REF : CGS2398 SHEET : 1 OF 1 EQUIPMENT TYPE : 5.5t Excavator METHOD : 300 mm Hydraulic Auger DATE EXCAVATED : 9/9/14 LOGGED BY : BB CHECKED BY : 0.05m STRUCTURE & Other Observations 400 HAND PENETROMETER (kPa) 300 200 100 DYNAMIC PENETROMETER MOISTURE / TOPSOIL, Silty Sandy CLAY, low plasticity, dark brown, with organics WEATHERING SYMBOL MATERIAL DESCRIPTION Soil Type, plasticity or particle characteristic, colour Rock Type, grain size, colour Secondary and minor components CONSISTENCY / REL DENSITY / ROCK STRENGTH 0.0 CLASSIFICATION GRAPHIC LOG DEPTH (m) SAMPLES & FIELD TESTS GROUND WATER LEVELS LOCATION : See Drawing for location M-W Silty CLAY, medium to high plasticity, brown mottled red, trace sand, trace root fibres HP In-situ = 500 kPa MC > PL H Not Encountered 0.5 >> HP In-situ = 600 kPa 0.80m SILTSTONE, grey GEOTECH_SOLUTIONS_03 LIBRARY.GLB Log CGS_TESTHOLE_LOG_02 CGS_2398_ NORTHLAKES ESTATE STAGES 33 & 34.GPJ 10/10/2014 14:07 8.30.003 1.0 XW EL 1.20m Testbore TB020 terminated at 1.20 m Virtual refusal on weathered siltstone 1.5 2.0 WATER / MOISTURE SAMPLES & FIELD TESTS CONSISTENCY RELATIVE DENSITY ROCK STRENGTH ROCK WEATHERING D M W OMC PL U D ES B SPT HP VS S F St VSt H VL L MD D VD EL VL L M H VH EH RS XW DW SW FR - Dry Moist Wet Optimum MC Plastic Limit Water inflow See Explanatory Notes for details of abbreviations & basis of descriptions. - Undisturbed Sample Disturbed Sample Environmental sample Bulk Disturbed Sample Standard Penetration Test Hand/Pocket Penetrometer - Very Soft Soft Firm Stiff Very Stiff Hard - Very Loose Loose Medium Dense Dense Very Dense - Extremely low Very low Low Medium High Very high Extremely high - Residual soil Extremely weathered Distinctly weathered Slightly weathered Fresh rock CARDNO GEOTECH SOLUTIONS File: CGS2398 TB020 Page 1 OF 1 TESTBORE LOG CLIENT : Northlakes Pty Ltd C/- McCloy Group PROJECT : Site Classification LOCATION : Stage 33 & 34, Northlakes Estate, Cameron Park HOLE NO : TB021 PROJECT REF : CGS2398 SHEET : 1 OF 1 EQUIPMENT TYPE : 5.5t Excavator METHOD : 300 mm Hydraulic Auger DATE EXCAVATED : 9/9/14 LOGGED BY : BB CHECKED BY : STRUCTURE & Other Observations 400 HAND PENETROMETER (kPa) 300 200 100 DYNAMIC PENETROMETER MOISTURE / WEATHERING SYMBOL MATERIAL DESCRIPTION Soil Type, plasticity or particle characteristic, colour Rock Type, grain size, colour Secondary and minor components CONSISTENCY / REL DENSITY / ROCK STRENGTH 0.0 CLASSIFICATION GRAPHIC LOG DEPTH (m) SAMPLES & FIELD TESTS GROUND WATER LEVELS LOCATION : See Drawing for location TOPSOIL, Silty Sandy CLAY, low to medium plasticity, pale grey-brown, with root fibres, trace gravel M-W 0.30m Silty Sandy CLAY, medium to high plasticity, grey cobbles present between 0.3-0.4 HP In-situ = 250 kPa Not Encountered 0.5 MC > PL St - VSt HP In-situ = 350 kPa 0.90m SILTSTONE, pale grey-white GEOTECH_SOLUTIONS_03 LIBRARY.GLB Log CGS_TESTHOLE_LOG_02 CGS_2398_ NORTHLAKES ESTATE STAGES 33 & 34.GPJ 10/10/2014 14:07 8.30.003 1.0 XW EL 1.30m Testbore TB021 terminated at 1.30 m Virtual refusal on weathered siltstone 1.5 2.0 WATER / MOISTURE SAMPLES & FIELD TESTS CONSISTENCY RELATIVE DENSITY ROCK STRENGTH ROCK WEATHERING D M W OMC PL U D ES B SPT HP VS S F St VSt H VL L MD D VD EL VL L M H VH EH RS XW DW SW FR - Dry Moist Wet Optimum MC Plastic Limit Water inflow See Explanatory Notes for details of abbreviations & basis of descriptions. - Undisturbed Sample Disturbed Sample Environmental sample Bulk Disturbed Sample Standard Penetration Test Hand/Pocket Penetrometer - Very Soft Soft Firm Stiff Very Stiff Hard - Very Loose Loose Medium Dense Dense Very Dense - Extremely low Very low Low Medium High Very high Extremely high - Residual soil Extremely weathered Distinctly weathered Slightly weathered Fresh rock CARDNO GEOTECH SOLUTIONS File: CGS2398 TB021 Page 1 OF 1 CLIENT : Northlakes Pty Ltd C/- McCloy Group PROJECT : Site Classification LOCATION : Stage 33 & 34, Northlakes Estate, Cameron Park TESTBORE LOG HOLE NO : TB022 PROJECT REF : CGS2398 SHEET : 1 OF 1 EQUIPMENT TYPE : 5.5t Excavator METHOD : 300 mm Hydraulic Auger DATE EXCAVATED : 9/9/14 LOGGED BY : BB CHECKED BY : STRUCTURE & Other Observations 400 HAND PENETROMETER (kPa) 300 200 100 DYNAMIC PENETROMETER MOISTURE / WEATHERING SYMBOL MATERIAL DESCRIPTION Soil Type, plasticity or particle characteristic, colour Rock Type, grain size, colour Secondary and minor components CONSISTENCY / REL DENSITY / ROCK STRENGTH 0.0 CLASSIFICATION GRAPHIC LOG DEPTH (m) SAMPLES & FIELD TESTS GROUND WATER LEVELS LOCATION : See Drawing for location FILL, Silty Clayey SAND, fine to coarse grained, dark brown-black, with organics 1 W 0.20m Silty Sandy CLAY, medium plasticity, dark brown-grey, with roots 3 5 0.5 8 MC > PL St Not Encountered 6 1.00m GEOTECH_SOLUTIONS_03 LIBRARY.GLB Log CGS_TESTHOLE_LOG_02 CGS_2398_ NORTHLAKES ESTATE STAGES 33 & 34.GPJ 10/10/2014 14:07 8.30.003 1.0 Silty Sandy CLAY, low plasticity, pale grey-brown, with siltstone fragments MC = PL St - VSt 1.5 1.60m SILTSTONE, pale grey-white XW EL - VL 1.80m Testbore TB022 terminated at 1.80 m Virtual refusal on weathered siltstone 2.0 WATER / MOISTURE SAMPLES & FIELD TESTS CONSISTENCY RELATIVE DENSITY ROCK STRENGTH ROCK WEATHERING D M W OMC PL U D ES B SPT HP VS S F St VSt H VL L MD D VD EL VL L M H VH EH RS XW DW SW FR - Dry Moist Wet Optimum MC Plastic Limit Water inflow See Explanatory Notes for details of abbreviations & basis of descriptions. - Undisturbed Sample Disturbed Sample Environmental sample Bulk Disturbed Sample Standard Penetration Test Hand/Pocket Penetrometer - Very Soft Soft Firm Stiff Very Stiff Hard - Very Loose Loose Medium Dense Dense Very Dense - Extremely low Very low Low Medium High Very high Extremely high - Residual soil Extremely weathered Distinctly weathered Slightly weathered Fresh rock CARDNO GEOTECH SOLUTIONS File: CGS2398 TB022 Page 1 OF 1 CLIENT : Northlakes Pty Ltd C/- McCloy Group PROJECT : Site Classification LOCATION : Stage 33 & 34, Northlakes Estate, Cameron Park TESTBORE LOG HOLE NO : TB023 PROJECT REF : CGS2398 SHEET : 1 OF 1 EQUIPMENT TYPE : 5.5t Excavator METHOD : 300 mm Hydraulic Auger DATE EXCAVATED : 9/9/14 LOGGED BY : BB CHECKED BY : STRUCTURE & Other Observations 400 HAND PENETROMETER (kPa) 300 200 100 DYNAMIC PENETROMETER MOISTURE / WEATHERING SYMBOL MATERIAL DESCRIPTION Soil Type, plasticity or particle characteristic, colour Rock Type, grain size, colour Secondary and minor components CONSISTENCY / REL DENSITY / ROCK STRENGTH 0.0 CLASSIFICATION GRAPHIC LOG DEPTH (m) SAMPLES & FIELD TESTS GROUND WATER LEVELS LOCATION : See Drawing for location FILL, Silty Sandy CLAY, dark brown, with organics (topsoil fill) M-W 0.20m 0.20m U50 FILL, Gravelly CLAY, medium plasticity, mottled pale brown & dark grey, with sand, trace cobbles 0.40m 0.5 Not Encountered MC > PL GEOTECH_SOLUTIONS_03 LIBRARY.GLB Log CGS_TESTHOLE_LOG_02 CGS_2398_ NORTHLAKES ESTATE STAGES 33 & 34.GPJ 10/10/2014 14:07 8.30.003 1.0 1.10m Silty CLAY, medium plasticity, mottled grey, brown & orange MC > PL VSt - H 1.5 1.60m Testbore TB023 terminated at 1.60 m Virtual refusal on weathered siltstone 2.0 WATER / MOISTURE SAMPLES & FIELD TESTS CONSISTENCY RELATIVE DENSITY ROCK STRENGTH ROCK WEATHERING D M W OMC PL U D ES B SPT HP VS S F St VSt H VL L MD D VD EL VL L M H VH EH RS XW DW SW FR - Dry Moist Wet Optimum MC Plastic Limit Water inflow See Explanatory Notes for details of abbreviations & basis of descriptions. - Undisturbed Sample Disturbed Sample Environmental sample Bulk Disturbed Sample Standard Penetration Test Hand/Pocket Penetrometer - Very Soft Soft Firm Stiff Very Stiff Hard - Very Loose Loose Medium Dense Dense Very Dense - Extremely low Very low Low Medium High Very high Extremely high - Residual soil Extremely weathered Distinctly weathered Slightly weathered Fresh rock CARDNO GEOTECH SOLUTIONS File: CGS2398 TB023 Page 1 OF 1 CLIENT : Northlakes Pty Ltd C/- McCloy Group PROJECT : Site Classification LOCATION : Stage 33 & 34, Northlakes Estate, Cameron Park TESTBORE LOG HOLE NO : TB024 PROJECT REF : CGS2398 SHEET : 1 OF 1 EQUIPMENT TYPE : 5.5t Excavator METHOD : 300 mm Hydraulic Auger DATE EXCAVATED : 9/9/14 LOGGED BY : BB CHECKED BY : STRUCTURE & Other Observations 400 HAND PENETROMETER (kPa) 300 200 100 DYNAMIC PENETROMETER MOISTURE / WEATHERING SYMBOL MATERIAL DESCRIPTION Soil Type, plasticity or particle characteristic, colour Rock Type, grain size, colour Secondary and minor components CONSISTENCY / REL DENSITY / ROCK STRENGTH 0.0 CLASSIFICATION GRAPHIC LOG DEPTH (m) SAMPLES & FIELD TESTS GROUND WATER LEVELS LOCATION : See Drawing for location FILL, Clayey Silty SAND, fine to coarse grained, brown, with organics 1 M 3 0.30m FILL, Gravelly Silty CLAY, medum plasticity, brown-grey mottled orange & white, with sand, trace cobbles 9 R 0.5 0.90m Not Encountered GEOTECH_SOLUTIONS_03 LIBRARY.GLB Log CGS_TESTHOLE_LOG_02 CGS_2398_ NORTHLAKES ESTATE STAGES 33 & 34.GPJ 10/10/2014 14:07 8.30.003 MC > PL FILL, Silty CLAY, medium plasticity, mottled brown-grey & orange, trace gravel & sand 1.0 MC > PL 1.5 2.00m 2.0 Testbore TB024 terminated at 2.00 m Target depth WATER / MOISTURE SAMPLES & FIELD TESTS CONSISTENCY RELATIVE DENSITY ROCK STRENGTH ROCK WEATHERING D M W OMC PL U D ES B SPT HP VS S F St VSt H VL L MD D VD EL VL L M H VH EH RS XW DW SW FR - Dry Moist Wet Optimum MC Plastic Limit Water inflow See Explanatory Notes for details of abbreviations & basis of descriptions. - Undisturbed Sample Disturbed Sample Environmental sample Bulk Disturbed Sample Standard Penetration Test Hand/Pocket Penetrometer - Very Soft Soft Firm Stiff Very Stiff Hard - Very Loose Loose Medium Dense Dense Very Dense - Extremely low Very low Low Medium High Very high Extremely high - Residual soil Extremely weathered Distinctly weathered Slightly weathered Fresh rock CARDNO GEOTECH SOLUTIONS File: CGS2398 TB024 Page 1 OF 1 CLIENT : Northlakes Pty Ltd C/- McCloy Group PROJECT : Site Classification LOCATION : Stage 33 & 34, Northlakes Estate, Cameron Park TESTBORE LOG HOLE NO : TB025 PROJECT REF : CGS2398 SHEET : 1 OF 1 EQUIPMENT TYPE : 5.5t Excavator METHOD : 300 mm Hydraulic Auger DATE EXCAVATED : 9/9/14 LOGGED BY : BB CHECKED BY : STRUCTURE & Other Observations 400 HAND PENETROMETER (kPa) 300 200 100 DYNAMIC PENETROMETER MOISTURE / FILL, Silty Clayey SAND, fine to coarse grained, dark brown, with organics (topsoil fill) WEATHERING SYMBOL MATERIAL DESCRIPTION Soil Type, plasticity or particle characteristic, colour Rock Type, grain size, colour Secondary and minor components CONSISTENCY / REL DENSITY / ROCK STRENGTH 0.0 CLASSIFICATION GRAPHIC LOG DEPTH (m) SAMPLES & FIELD TESTS GROUND WATER LEVELS LOCATION : See Drawing for location MC > PL 1 0.10m FILL, Silty Sandy CLAY, medium to high plasticity, grey-brown mottled orange 3 MC > PL St 3 0.50m 0.5 Silty CLAY, low to medium plasticity, mottled pale grey & orange, trace sand and fine gravel 6 5 Siltstone boulder present @ 0.8 m GEOTECH_SOLUTIONS_03 LIBRARY.GLB Log CGS_TESTHOLE_LOG_02 CGS_2398_ NORTHLAKES ESTATE STAGES 33 & 34.GPJ 10/10/2014 14:07 8.30.003 Not Encountered 4 4 1.0 MC > PL St 5 6 6 1.5 10 1.70m Silty CLAY, low plasticity, dark brown-black (carbonaceous) MC = PL H 1.90m Testbore TB025 terminated at 1.90 m Virtual refusal 2.0 on weathered siltstone WATER / MOISTURE SAMPLES & FIELD TESTS CONSISTENCY RELATIVE DENSITY ROCK STRENGTH ROCK WEATHERING D M W OMC PL U D ES B SPT HP VS S F St VSt H VL L MD D VD EL VL L M H VH EH RS XW DW SW FR - Dry Moist Wet Optimum MC Plastic Limit Water inflow See Explanatory Notes for details of abbreviations & basis of descriptions. - Undisturbed Sample Disturbed Sample Environmental sample Bulk Disturbed Sample Standard Penetration Test Hand/Pocket Penetrometer - Very Soft Soft Firm Stiff Very Stiff Hard - Very Loose Loose Medium Dense Dense Very Dense - Extremely low Very low Low Medium High Very high Extremely high - Residual soil Extremely weathered Distinctly weathered Slightly weathered Fresh rock CARDNO GEOTECH SOLUTIONS File: CGS2398 TB025 Page 1 OF 1 CLIENT : Northlakes Pty Ltd C/- McCloy Group PROJECT : Site Classification LOCATION : Stage 33 & 34, Northlakes Estate, Cameron Park TESTBORE LOG HOLE NO : TB026 PROJECT REF : CGS2398 SHEET : 1 OF 1 EQUIPMENT TYPE : 3.5t Excavator METHOD : 300 mm Hydraulic Auger DATE EXCAVATED : 19/9/14 LOGGED BY : KH CHECKED BY : STRUCTURE & Other Observations 400 HAND PENETROMETER (kPa) 300 200 100 DYNAMIC PENETROMETER MOISTURE / WEATHERING SYMBOL MATERIAL DESCRIPTION Soil Type, plasticity or particle characteristic, colour Rock Type, grain size, colour Secondary and minor components CONSISTENCY / REL DENSITY / ROCK STRENGTH 0.0 CLASSIFICATION GRAPHIC LOG DEPTH (m) SAMPLES & FIELD TESTS GROUND WATER LEVELS LOCATION : See Drawing for location TOPSOIL: Sandy SILT; brown, fine to medium grained sand, with fine to medium sub-angular to sub-rounded gravel, with cobbles, trace orangics 15 D 0.20m Silty CLAY; grey mottled brown, low to medium plasticity, with fine grained sand 15 Not Encountered R MC < PL 0.5 0.70m SANDSTONE; brown, fine grained sand HW VL 0.90m Testbore TB026 terminated at 0.90 m Refusal GEOTECH_SOLUTIONS_03 LIBRARY.GLB Log CGS_TESTHOLE_LOG_02 CGS_2398_ NORTHLAKES ESTATE STAGES 33 & 34.GPJ 10/10/2014 14:07 8.30.003 1.0 on weathered sandstone 1.5 2.0 WATER / MOISTURE SAMPLES & FIELD TESTS CONSISTENCY RELATIVE DENSITY ROCK STRENGTH ROCK WEATHERING D M W OMC PL U D ES B SPT HP VS S F St VSt H VL L MD D VD EL VL L M H VH EH RS XW DW SW FR - Dry Moist Wet Optimum MC Plastic Limit Water inflow See Explanatory Notes for details of abbreviations & basis of descriptions. - Undisturbed Sample Disturbed Sample Environmental sample Bulk Disturbed Sample Standard Penetration Test Hand/Pocket Penetrometer - Very Soft Soft Firm Stiff Very Stiff Hard - Very Loose Loose Medium Dense Dense Very Dense - Extremely low Very low Low Medium High Very high Extremely high - Residual soil Extremely weathered Distinctly weathered Slightly weathered Fresh rock CARDNO GEOTECH SOLUTIONS File: CGS2398 TB026 Page 1 OF 1 CLIENT : Northlakes Pty Ltd C/- McCloy Group PROJECT : Site Classification LOCATION : Stage 33 & 34, Northlakes Estate, Cameron Park TESTBORE LOG HOLE NO : TB027 PROJECT REF : CGS2398 SHEET : 1 OF 1 EQUIPMENT TYPE : 3.5t Excavator METHOD : 300 mm Hydraulic Auger DATE EXCAVATED : 19/9/14 LOGGED BY : KH CHECKED BY : STRUCTURE & Other Observations 400 HAND PENETROMETER (kPa) 300 200 100 DYNAMIC PENETROMETER MOISTURE / WEATHERING SYMBOL MATERIAL DESCRIPTION Soil Type, plasticity or particle characteristic, colour Rock Type, grain size, colour Secondary and minor components CONSISTENCY / REL DENSITY / ROCK STRENGTH 0.0 CLASSIFICATION GRAPHIC LOG DEPTH (m) SAMPLES & FIELD TESTS GROUND WATER LEVELS LOCATION : See Drawing for location Silty CLAY; brown mottled grey, low to medium plasticity, trace fine grained sand 3 Not Encountered 5 MC < PL St - VSt 7 0.5 21 0.70m SANDSTONE; brown XW EL 0.80m Testbore TB027 terminated at 0.80 m Refusal on weathered sandstone GEOTECH_SOLUTIONS_03 LIBRARY.GLB Log CGS_TESTHOLE_LOG_02 CGS_2398_ NORTHLAKES ESTATE STAGES 33 & 34.GPJ 10/10/2014 14:07 8.30.003 1.0 1.5 2.0 WATER / MOISTURE SAMPLES & FIELD TESTS CONSISTENCY RELATIVE DENSITY ROCK STRENGTH ROCK WEATHERING D M W OMC PL U D ES B SPT HP VS S F St VSt H VL L MD D VD EL VL L M H VH EH RS XW DW SW FR - Dry Moist Wet Optimum MC Plastic Limit Water inflow See Explanatory Notes for details of abbreviations & basis of descriptions. - Undisturbed Sample Disturbed Sample Environmental sample Bulk Disturbed Sample Standard Penetration Test Hand/Pocket Penetrometer - Very Soft Soft Firm Stiff Very Stiff Hard - Very Loose Loose Medium Dense Dense Very Dense - Extremely low Very low Low Medium High Very high Extremely high - Residual soil Extremely weathered Distinctly weathered Slightly weathered Fresh rock CARDNO GEOTECH SOLUTIONS File: CGS2398 TB027 Page 1 OF 1 CLIENT : Northlakes Pty Ltd C/- McCloy Group PROJECT : Site Classification LOCATION : Stage 33 & 34, Northlakes Estate, Cameron Park TESTBORE LOG HOLE NO : TB028 PROJECT REF : CGS2398 SHEET : 1 OF 1 EQUIPMENT TYPE : 3.5t Excavator METHOD : 300 mm Hydraulic Auger DATE EXCAVATED : 19/9/14 LOGGED BY : KH CHECKED BY : STRUCTURE & Other Observations 400 HAND PENETROMETER (kPa) 300 200 100 DYNAMIC PENETROMETER MOISTURE / WEATHERING SYMBOL MATERIAL DESCRIPTION Soil Type, plasticity or particle characteristic, colour Rock Type, grain size, colour Secondary and minor components CONSISTENCY / REL DENSITY / ROCK STRENGTH 0.0 CLASSIFICATION GRAPHIC LOG DEPTH (m) SAMPLES & FIELD TESTS GROUND WATER LEVELS LOCATION : See Drawing for location Sandy Silty CLAY; grey, with sandstone boulders 1 6 Not Encountered M 15 0.50m 0.5 SANDSTONE; brown 18 XW - HW VL 0.70m Testbore TB028 terminated at 0.70 m Refusal on weathered sandstone GEOTECH_SOLUTIONS_03 LIBRARY.GLB Log CGS_TESTHOLE_LOG_02 CGS_2398_ NORTHLAKES ESTATE STAGES 33 & 34.GPJ 10/10/2014 14:07 8.30.003 1.0 1.5 2.0 WATER / MOISTURE SAMPLES & FIELD TESTS CONSISTENCY RELATIVE DENSITY ROCK STRENGTH ROCK WEATHERING D M W OMC PL U D ES B SPT HP VS S F St VSt H VL L MD D VD EL VL L M H VH EH RS XW DW SW FR - Dry Moist Wet Optimum MC Plastic Limit Water inflow See Explanatory Notes for details of abbreviations & basis of descriptions. - Undisturbed Sample Disturbed Sample Environmental sample Bulk Disturbed Sample Standard Penetration Test Hand/Pocket Penetrometer - Very Soft Soft Firm Stiff Very Stiff Hard - Very Loose Loose Medium Dense Dense Very Dense - Extremely low Very low Low Medium High Very high Extremely high - Residual soil Extremely weathered Distinctly weathered Slightly weathered Fresh rock CARDNO GEOTECH SOLUTIONS File: CGS2398 TB028 Page 1 OF 1 CLIENT : Northlakes Pty Ltd C/- McCloy Group PROJECT : Site Classification LOCATION : Stage 33 & 34, Northlakes Estate, Cameron Park TESTBORE LOG HOLE NO : TB029 PROJECT REF : CGS2398 SHEET : 1 OF 1 EQUIPMENT TYPE : 3.5t Excavator METHOD : 300 mm Hydraulic Auger DATE EXCAVATED : 19/9/14 LOGGED BY : KH CHECKED BY : STRUCTURE & Other Observations 400 HAND PENETROMETER (kPa) 300 200 100 DYNAMIC PENETROMETER MOISTURE / WEATHERING SYMBOL MATERIAL DESCRIPTION Soil Type, plasticity or particle characteristic, colour Rock Type, grain size, colour Secondary and minor components CONSISTENCY / REL DENSITY / ROCK STRENGTH 0.0 CLASSIFICATION GRAPHIC LOG DEPTH (m) SAMPLES & FIELD TESTS GROUND WATER LEVELS LOCATION : See Drawing for location Sandy Silty CLAY; grey, with sandstone boulders Not Encountered M 0.50m 0.5 SANDSTONE; brown XW - HW VL 0.70m Testbore TB029 terminated at 0.70 m Refusal on weathered sandstone GEOTECH_SOLUTIONS_03 LIBRARY.GLB Log CGS_TESTHOLE_LOG_02 CGS_2398_ NORTHLAKES ESTATE STAGES 33 & 34.GPJ 10/10/2014 14:07 8.30.003 1.0 1.5 2.0 WATER / MOISTURE SAMPLES & FIELD TESTS CONSISTENCY RELATIVE DENSITY ROCK STRENGTH ROCK WEATHERING D M W OMC PL U D ES B SPT HP VS S F St VSt H VL L MD D VD EL VL L M H VH EH RS XW DW SW FR - Dry Moist Wet Optimum MC Plastic Limit Water inflow See Explanatory Notes for details of abbreviations & basis of descriptions. - Undisturbed Sample Disturbed Sample Environmental sample Bulk Disturbed Sample Standard Penetration Test Hand/Pocket Penetrometer - Very Soft Soft Firm Stiff Very Stiff Hard - Very Loose Loose Medium Dense Dense Very Dense - Extremely low Very low Low Medium High Very high Extremely high - Residual soil Extremely weathered Distinctly weathered Slightly weathered Fresh rock CARDNO GEOTECH SOLUTIONS File: CGS2398 TB029 Page 1 OF 1 CLIENT : Northlakes Pty Ltd C/- McCloy Group PROJECT : Site Classification LOCATION : Stage 33 & 34, Northlakes Estate, Cameron Park TESTBORE LOG HOLE NO : TB030 PROJECT REF : CGS2398 SHEET : 1 OF 1 EQUIPMENT TYPE : 3.5t Excavator METHOD : 300 mm Hydraulic Auger DATE EXCAVATED : 19/9/14 LOGGED BY : KH CHECKED BY : STRUCTURE & Other Observations 400 HAND PENETROMETER (kPa) 300 200 100 DYNAMIC PENETROMETER MOISTURE / WEATHERING SYMBOL MATERIAL DESCRIPTION Soil Type, plasticity or particle characteristic, colour Rock Type, grain size, colour Secondary and minor components CONSISTENCY / REL DENSITY / ROCK STRENGTH 0.0 CLASSIFICATION GRAPHIC LOG DEPTH (m) SAMPLES & FIELD TESTS GROUND WATER LEVELS LOCATION : See Drawing for location Silty Sandy CLAY; low to medium plasticity, grey mottled brown, fine to medium grained sand 3 MC = PL F Not Encountered 0.20m Sandy CLAY; low to medium plasticity, grey, fine to medium grained sand 8 MC = PL St 15 R 0.50m 0.5 SANDSTONE: brown, fine to medium grained HW VL 0.60m Testbore TB030 terminated at 0.60 m Refusal on weathered sandstone GEOTECH_SOLUTIONS_03 LIBRARY.GLB Log CGS_TESTHOLE_LOG_02 CGS_2398_ NORTHLAKES ESTATE STAGES 33 & 34.GPJ 10/10/2014 14:07 8.30.003 1.0 1.5 2.0 WATER / MOISTURE SAMPLES & FIELD TESTS CONSISTENCY RELATIVE DENSITY ROCK STRENGTH ROCK WEATHERING D M W OMC PL U D ES B SPT HP VS S F St VSt H VL L MD D VD EL VL L M H VH EH RS XW DW SW FR - Dry Moist Wet Optimum MC Plastic Limit Water inflow See Explanatory Notes for details of abbreviations & basis of descriptions. - Undisturbed Sample Disturbed Sample Environmental sample Bulk Disturbed Sample Standard Penetration Test Hand/Pocket Penetrometer - Very Soft Soft Firm Stiff Very Stiff Hard - Very Loose Loose Medium Dense Dense Very Dense - Extremely low Very low Low Medium High Very high Extremely high - Residual soil Extremely weathered Distinctly weathered Slightly weathered Fresh rock CARDNO GEOTECH SOLUTIONS File: CGS2398 TB030 Page 1 OF 1 CLIENT : Northlakes Pty Ltd C/- McCloy Group PROJECT : Site Classification LOCATION : Stage 33 & 34, Northlakes Estate, Cameron Park TESTBORE LOG HOLE NO : TB031 PROJECT REF : CGS2398 SHEET : 1 OF 1 EQUIPMENT TYPE : 3.5t Excavator METHOD : 300 mm Hydraulic Auger DATE EXCAVATED : 19/9/14 LOGGED BY : KH CHECKED BY : D-M STRUCTURE & Other Observations 400 HAND PENETROMETER (kPa) 300 200 100 DYNAMIC PENETROMETER MOISTURE / TOPSOIL: Silty SAND; grey, fine to medium grained, with fine to medium sub-angular to sub-rounded gravel WEATHERING SYMBOL MATERIAL DESCRIPTION Soil Type, plasticity or particle characteristic, colour Rock Type, grain size, colour Secondary and minor components CONSISTENCY / REL DENSITY / ROCK STRENGTH 0.0 CLASSIFICATION GRAPHIC LOG DEPTH (m) SAMPLES & FIELD TESTS GROUND WATER LEVELS LOCATION : See Drawing for location L 15 0.10m Not Encountered Sandy CLAY; low plasticity, grey mottled brown, fine to medium grained sand R MC < PL H HW EL - VL HP In-situ > 400 kPa 0.50m 0.5 SANDSTONE; brown 0.70m Testbore TB031 terminated at 0.70 m Refusal on weathered sandstone GEOTECH_SOLUTIONS_03 LIBRARY.GLB Log CGS_TESTHOLE_LOG_02 CGS_2398_ NORTHLAKES ESTATE STAGES 33 & 34.GPJ 10/10/2014 14:07 8.30.003 1.0 1.5 2.0 WATER / MOISTURE SAMPLES & FIELD TESTS CONSISTENCY RELATIVE DENSITY ROCK STRENGTH ROCK WEATHERING D M W OMC PL U D ES B SPT HP VS S F St VSt H VL L MD D VD EL VL L M H VH EH RS XW DW SW FR - Dry Moist Wet Optimum MC Plastic Limit Water inflow See Explanatory Notes for details of abbreviations & basis of descriptions. - Undisturbed Sample Disturbed Sample Environmental sample Bulk Disturbed Sample Standard Penetration Test Hand/Pocket Penetrometer - Very Soft Soft Firm Stiff Very Stiff Hard - Very Loose Loose Medium Dense Dense Very Dense - Extremely low Very low Low Medium High Very high Extremely high - Residual soil Extremely weathered Distinctly weathered Slightly weathered Fresh rock CARDNO GEOTECH SOLUTIONS File: CGS2398 TB031 Page 1 OF 1 CLIENT : Northlakes Pty Ltd C/- McCloy Group PROJECT : Site Classification LOCATION : Stage 33 & 34, Northlakes Estate, Cameron Park TESTBORE LOG HOLE NO : TB032 PROJECT REF : CGS2398 SHEET : 1 OF 1 EQUIPMENT TYPE : 3.5t Excavator METHOD : 300 mm Hydraulic Auger DATE EXCAVATED : 19/9/14 LOGGED BY : KH CHECKED BY : STRUCTURE & Other Observations 400 HAND PENETROMETER (kPa) 300 200 100 DYNAMIC PENETROMETER MOISTURE / WEATHERING SYMBOL MATERIAL DESCRIPTION Soil Type, plasticity or particle characteristic, colour Rock Type, grain size, colour Secondary and minor components CONSISTENCY / REL DENSITY / ROCK STRENGTH 0.0 CLASSIFICATION GRAPHIC LOG DEPTH (m) SAMPLES & FIELD TESTS GROUND WATER LEVELS LOCATION : See Drawing for location Sandy CLAY; low to medium plasticity, grey mottled brown, fine to medium grained sand, with silt 3 4 Not Encountered MC = PL VSt HP In-situ = 300 - 350 kPa 5 0.5 15 0.60m SANDSTONE; grey, fine to medium grained MW VL 0.80m Testbore TB032 terminated at 0.80 m Refusal on weathered sandstone GEOTECH_SOLUTIONS_03 LIBRARY.GLB Log CGS_TESTHOLE_LOG_02 CGS_2398_ NORTHLAKES ESTATE STAGES 33 & 34.GPJ 10/10/2014 14:07 8.30.003 1.0 1.5 2.0 WATER / MOISTURE SAMPLES & FIELD TESTS CONSISTENCY RELATIVE DENSITY ROCK STRENGTH ROCK WEATHERING D M W OMC PL U D ES B SPT HP VS S F St VSt H VL L MD D VD EL VL L M H VH EH RS XW DW SW FR - Dry Moist Wet Optimum MC Plastic Limit Water inflow See Explanatory Notes for details of abbreviations & basis of descriptions. - Undisturbed Sample Disturbed Sample Environmental sample Bulk Disturbed Sample Standard Penetration Test Hand/Pocket Penetrometer - Very Soft Soft Firm Stiff Very Stiff Hard - Very Loose Loose Medium Dense Dense Very Dense - Extremely low Very low Low Medium High Very high Extremely high - Residual soil Extremely weathered Distinctly weathered Slightly weathered Fresh rock CARDNO GEOTECH SOLUTIONS File: CGS2398 TB032 Page 1 OF 1 CLIENT : Northlakes Pty Ltd C/- McCloy Group PROJECT : Site Classification LOCATION : Stage 33 & 34, Northlakes Estate, Cameron Park TESTBORE LOG HOLE NO : TB033 PROJECT REF : CGS2398 SHEET : 1 OF 1 EQUIPMENT TYPE : 3.5t Excavator METHOD : 300 mm Hydraulic Auger DATE EXCAVATED : 19/9/14 LOGGED BY : KH CHECKED BY : STRUCTURE & Other Observations 400 HAND PENETROMETER (kPa) 300 200 100 L - MD DYNAMIC PENETROMETER CONSISTENCY / REL DENSITY / ROCK STRENGTH D-M MOISTURE / SYMBOL MATERIAL DESCRIPTION Soil Type, plasticity or particle characteristic, colour Rock Type, grain size, colour Secondary and minor components TOPSOIL: Silty SAND; grey, fine to medium grained, with clay, with fine to medium sub-angular to sub-rounded gravel 0.20m 0.20m U50 Not Encountered WEATHERING 0.0 CLASSIFICATION GRAPHIC LOG DEPTH (m) SAMPLES & FIELD TESTS GROUND WATER LEVELS LOCATION : See Drawing for location Silty CLAY; low plasticity, grey mottled brown, with fine to medium grained sand HP In-situ > 400 kPa 0.50m 0.5 MC < PL H HW VL 0.80m SANDSTONE: grey 1.00m GEOTECH_SOLUTIONS_03 LIBRARY.GLB Log CGS_TESTHOLE_LOG_02 CGS_2398_ NORTHLAKES ESTATE STAGES 33 & 34.GPJ 10/10/2014 14:07 8.30.003 1.0 Testbore TB033 terminated at 1.00 m Refusal on weathered sandstone 1.5 2.0 WATER / MOISTURE SAMPLES & FIELD TESTS CONSISTENCY RELATIVE DENSITY ROCK STRENGTH ROCK WEATHERING D M W OMC PL U D ES B SPT HP VS S F St VSt H VL L MD D VD EL VL L M H VH EH RS XW DW SW FR - Dry Moist Wet Optimum MC Plastic Limit Water inflow See Explanatory Notes for details of abbreviations & basis of descriptions. - Undisturbed Sample Disturbed Sample Environmental sample Bulk Disturbed Sample Standard Penetration Test Hand/Pocket Penetrometer - Very Soft Soft Firm Stiff Very Stiff Hard - Very Loose Loose Medium Dense Dense Very Dense - Extremely low Very low Low Medium High Very high Extremely high - Residual soil Extremely weathered Distinctly weathered Slightly weathered Fresh rock CARDNO GEOTECH SOLUTIONS File: CGS2398 TB033 Page 1 OF 1 CLIENT : Northlakes Pty Ltd C/- McCloy Group PROJECT : Site Classification LOCATION : Stage 33 & 34, Northlakes Estate, Cameron Park TESTBORE LOG HOLE NO : TB034 PROJECT REF : CGS2398 SHEET : 1 OF 1 EQUIPMENT TYPE : 3.5t Excavator METHOD : 300 mm Hydraulic Auger DATE EXCAVATED : 19/9/14 LOGGED BY : KH CHECKED BY : STRUCTURE & Other Observations 400 HAND PENETROMETER (kPa) 300 200 100 DYNAMIC PENETROMETER MOISTURE / WEATHERING SYMBOL MATERIAL DESCRIPTION Soil Type, plasticity or particle characteristic, colour Rock Type, grain size, colour Secondary and minor components CONSISTENCY / REL DENSITY / ROCK STRENGTH 0.0 CLASSIFICATION GRAPHIC LOG DEPTH (m) SAMPLES & FIELD TESTS GROUND WATER LEVELS LOCATION : See Drawing for location FILL: Silty Clayey SAND; grey, fine to medium grained 8 W L 0.20m Silty CLAY; low plasticity, grey mottled brown, with fine to medium grained sand 15 HP In-situ > 400 kPa Not Encountered 17 0.5 MC < PL 1.00m 1.0 GEOTECH_SOLUTIONS_03 LIBRARY.GLB Log CGS_TESTHOLE_LOG_02 CGS_2398_ NORTHLAKES ESTATE STAGES 33 & 34.GPJ 10/10/2014 14:07 8.30.003 H SANDSTONE: grey mottled brown, fine to medium grained EL HW VL - L 1.10m Testbore TB034 terminated at 1.10 m Refusal on weathered sandstone 1.5 2.0 WATER / MOISTURE SAMPLES & FIELD TESTS CONSISTENCY RELATIVE DENSITY ROCK STRENGTH ROCK WEATHERING D M W OMC PL U D ES B SPT HP VS S F St VSt H VL L MD D VD EL VL L M H VH EH RS XW DW SW FR - Dry Moist Wet Optimum MC Plastic Limit Water inflow See Explanatory Notes for details of abbreviations & basis of descriptions. - Undisturbed Sample Disturbed Sample Environmental sample Bulk Disturbed Sample Standard Penetration Test Hand/Pocket Penetrometer - Very Soft Soft Firm Stiff Very Stiff Hard - Very Loose Loose Medium Dense Dense Very Dense - Extremely low Very low Low Medium High Very high Extremely high - Residual soil Extremely weathered Distinctly weathered Slightly weathered Fresh rock CARDNO GEOTECH SOLUTIONS File: CGS2398 TB034 Page 1 OF 1 CLIENT : Northlakes Pty Ltd C/- McCloy Group PROJECT : Site Classification LOCATION : Stage 33 & 34, Northlakes Estate, Cameron Park TESTBORE LOG HOLE NO : TB035 PROJECT REF : CGS2398 SHEET : 1 OF 1 EQUIPMENT TYPE : 3.5t Excavator METHOD : 300 mm Hydraulic Auger DATE EXCAVATED : 19/9/14 LOGGED BY : KH CHECKED BY : STRUCTURE & Other Observations 400 HAND PENETROMETER (kPa) 300 200 100 DYNAMIC PENETROMETER MOISTURE / WEATHERING SYMBOL MATERIAL DESCRIPTION Soil Type, plasticity or particle characteristic, colour Rock Type, grain size, colour Secondary and minor components CONSISTENCY / REL DENSITY / ROCK STRENGTH 0.0 CLASSIFICATION GRAPHIC LOG DEPTH (m) SAMPLES & FIELD TESTS GROUND WATER LEVELS LOCATION : See Drawing for location Sandy CLAY; low to medium plasticity, grey mottled brown, fine to medium grained sand 8 MC < PL St 0.20m Silty CLAY; low to medium plasticity, grey mottled brown, with fine to medium grained sand 15 0.30m R U50 HP In-situ > 400 kPa 0.45m MC < PL H MC < PL H XW EL Not Encountered 0.5 0.80m Sandy CLAY; low to medium plasticity, grey mottled brown, fine to medium grained sand GEOTECH_SOLUTIONS_03 LIBRARY.GLB Log CGS_TESTHOLE_LOG_02 CGS_2398_ NORTHLAKES ESTATE STAGES 33 & 34.GPJ 10/10/2014 14:07 8.30.003 1.0 1.10m SANDSTONE; brown, fine to medium grained 1.30m Testbore TB035 terminated at 1.30 m Refusal on weathered sandstone 1.5 2.0 WATER / MOISTURE SAMPLES & FIELD TESTS CONSISTENCY RELATIVE DENSITY ROCK STRENGTH ROCK WEATHERING D M W OMC PL U D ES B SPT HP VS S F St VSt H VL L MD D VD EL VL L M H VH EH RS XW DW SW FR - Dry Moist Wet Optimum MC Plastic Limit Water inflow See Explanatory Notes for details of abbreviations & basis of descriptions. - Undisturbed Sample Disturbed Sample Environmental sample Bulk Disturbed Sample Standard Penetration Test Hand/Pocket Penetrometer - Very Soft Soft Firm Stiff Very Stiff Hard - Very Loose Loose Medium Dense Dense Very Dense - Extremely low Very low Low Medium High Very high Extremely high - Residual soil Extremely weathered Distinctly weathered Slightly weathered Fresh rock CARDNO GEOTECH SOLUTIONS File: CGS2398 TB035 Page 1 OF 1 TESTBORE LOG CLIENT : Northlakes Pty Ltd C/- McCloy Group PROJECT : Site Classification LOCATION : Stage 33 & 34, Northlakes Estate, Cameron Park HOLE NO : TB036 PROJECT REF : CGS2398 SHEET : 1 OF 1 EQUIPMENT TYPE : 3.5t Excavator METHOD : 300 mm Hydraulic Auger DATE EXCAVATED : 19/9/14 LOGGED BY : KH CHECKED BY : STRUCTURE & Other Observations 400 HAND PENETROMETER (kPa) 300 200 100 DYNAMIC PENETROMETER MOISTURE / WEATHERING SYMBOL MATERIAL DESCRIPTION Soil Type, plasticity or particle characteristic, colour Rock Type, grain size, colour Secondary and minor components CONSISTENCY / REL DENSITY / ROCK STRENGTH 0.0 CLASSIFICATION GRAPHIC LOG DEPTH (m) SAMPLES & FIELD TESTS GROUND WATER LEVELS LOCATION : See Drawing for location TOPSOIL: Silty Clayey SAND; grey, fine to medium grained W L 2 0.10m Silty Sandy CLAY; low to medium plasticity, grey mottled brown, fine grained St 3 Not Encountered HP In-situ > 400 kPa 5 MC > PL St - VSt 0.5 8 R H 0.80m SANDSTONE; grey mottled brown XW EL 0.90m Testbore TB036 terminated at 0.90 m Refusal GEOTECH_SOLUTIONS_03 LIBRARY.GLB Log CGS_TESTHOLE_LOG_02 CGS_2398_ NORTHLAKES ESTATE STAGES 33 & 34.GPJ 10/10/2014 14:07 8.30.003 1.0 on weathered sandstone 1.5 2.0 WATER / MOISTURE SAMPLES & FIELD TESTS CONSISTENCY RELATIVE DENSITY ROCK STRENGTH ROCK WEATHERING D M W OMC PL U D ES B SPT HP VS S F St VSt H VL L MD D VD EL VL L M H VH EH RS XW DW SW FR - Dry Moist Wet Optimum MC Plastic Limit Water inflow See Explanatory Notes for details of abbreviations & basis of descriptions. - Undisturbed Sample Disturbed Sample Environmental sample Bulk Disturbed Sample Standard Penetration Test Hand/Pocket Penetrometer - Very Soft Soft Firm Stiff Very Stiff Hard - Very Loose Loose Medium Dense Dense Very Dense - Extremely low Very low Low Medium High Very high Extremely high - Residual soil Extremely weathered Distinctly weathered Slightly weathered Fresh rock CARDNO GEOTECH SOLUTIONS File: CGS2398 TB036 Page 1 OF 1 TESTBORE LOG CLIENT : Northlakes Pty Ltd C/- McCloy Group PROJECT : Site Classification LOCATION : Stage 33 & 34, Northlakes Estate, Cameron Park HOLE NO : TB037 PROJECT REF : CGS2398 SHEET : 1 OF 1 EQUIPMENT TYPE : 3.5t Excavator METHOD : 300 mm Hydraulic Auger DATE EXCAVATED : 19/9/14 LOGGED BY : KH CHECKED BY : STRUCTURE & Other Observations 400 HAND PENETROMETER (kPa) 300 200 100 DYNAMIC PENETROMETER MOISTURE / WEATHERING SYMBOL MATERIAL DESCRIPTION Soil Type, plasticity or particle characteristic, colour Rock Type, grain size, colour Secondary and minor components CONSISTENCY / REL DENSITY / ROCK STRENGTH 0.0 CLASSIFICATION GRAPHIC LOG DEPTH (m) SAMPLES & FIELD TESTS GROUND WATER LEVELS LOCATION : See Drawing for location TOPSOIL: Silty Clayey SAND; grey, fine to medium grained D L 0.10m Silty CLAY; low to medium plasticity, grey mottled brown St HP In-situ = 300 kPa Not Encountered VSt MC = PL HP In-situ > 450 kPa 0.5 H 0.80m SANDSTONE: grey mottled brown XW 1.00m 1.0 GEOTECH_SOLUTIONS_03 LIBRARY.GLB Log CGS_TESTHOLE_LOG_02 CGS_2398_ NORTHLAKES ESTATE STAGES 33 & 34.GPJ 10/10/2014 14:07 8.30.003 EL Testbore TB037 terminated at 1.00 m Refusal on weathered sandstone 1.5 2.0 WATER / MOISTURE SAMPLES & FIELD TESTS CONSISTENCY RELATIVE DENSITY ROCK STRENGTH ROCK WEATHERING D M W OMC PL U D ES B SPT HP VS S F St VSt H VL L MD D VD EL VL L M H VH EH RS XW DW SW FR - Dry Moist Wet Optimum MC Plastic Limit Water inflow See Explanatory Notes for details of abbreviations & basis of descriptions. - Undisturbed Sample Disturbed Sample Environmental sample Bulk Disturbed Sample Standard Penetration Test Hand/Pocket Penetrometer - Very Soft Soft Firm Stiff Very Stiff Hard - Very Loose Loose Medium Dense Dense Very Dense - Extremely low Very low Low Medium High Very high Extremely high - Residual soil Extremely weathered Distinctly weathered Slightly weathered Fresh rock CARDNO GEOTECH SOLUTIONS File: CGS2398 TB037 Page 1 OF 1 CLIENT : Northlakes Pty Ltd C/- McCloy Group PROJECT : Site Classification LOCATION : Stage 33 & 34, Northlakes Estate, Cameron Park TESTBORE LOG HOLE NO : TB038 PROJECT REF : CGS2398 SHEET : 1 OF 1 EQUIPMENT TYPE : 3.5t Excavator METHOD : 300 mm Hydraulic Auger DATE EXCAVATED : 19/9/14 LOGGED BY : KH CHECKED BY : STRUCTURE & Other Observations 400 HAND PENETROMETER (kPa) 300 200 100 DYNAMIC PENETROMETER MOISTURE / WEATHERING SYMBOL MATERIAL DESCRIPTION Soil Type, plasticity or particle characteristic, colour Rock Type, grain size, colour Secondary and minor components CONSISTENCY / REL DENSITY / ROCK STRENGTH 0.0 CLASSIFICATION GRAPHIC LOG DEPTH (m) SAMPLES & FIELD TESTS GROUND WATER LEVELS LOCATION : See Drawing for location TOPSOIL: Silty Clayey SAND; grey, fine to medium grained D L 2 0.10m Silty CLAY; low to medium plasticity, grey mottled brown, trace fine grained sand 0.20m U50 3 MC > PL VSt 4 0.40m Not Encountered 0.5 4 0.60m R Sandy CLAY; low to medium plasticity, grey mottled brown, fine to medium grained sand, with silt MC > PL H XW EL GEOTECH_SOLUTIONS_03 LIBRARY.GLB Log CGS_TESTHOLE_LOG_02 CGS_2398_ NORTHLAKES ESTATE STAGES 33 & 34.GPJ 10/10/2014 14:07 8.30.003 1.0 1.10m SANDSTONE: brown 1.20m Testbore TB038 terminated at 1.20 m Refusal on weathered sandstone 1.5 2.0 WATER / MOISTURE SAMPLES & FIELD TESTS CONSISTENCY RELATIVE DENSITY ROCK STRENGTH ROCK WEATHERING D M W OMC PL U D ES B SPT HP VS S F St VSt H VL L MD D VD EL VL L M H VH EH RS XW DW SW FR - Dry Moist Wet Optimum MC Plastic Limit Water inflow See Explanatory Notes for details of abbreviations & basis of descriptions. - Undisturbed Sample Disturbed Sample Environmental sample Bulk Disturbed Sample Standard Penetration Test Hand/Pocket Penetrometer - Very Soft Soft Firm Stiff Very Stiff Hard - Very Loose Loose Medium Dense Dense Very Dense - Extremely low Very low Low Medium High Very high Extremely high - Residual soil Extremely weathered Distinctly weathered Slightly weathered Fresh rock CARDNO GEOTECH SOLUTIONS File: CGS2398 TB038 Page 1 OF 1 CLIENT : Northlakes Pty Ltd C/- McCloy Group PROJECT : Site Classification LOCATION : Stage 33 & 34, Northlakes Estate, Cameron Park TESTBORE LOG HOLE NO : TB039 PROJECT REF : CGS2398 SHEET : 1 OF 1 EQUIPMENT TYPE : 3.5t Excavator METHOD : 300 mm Hydraulic Auger DATE EXCAVATED : 19/9/14 LOGGED BY : KH CHECKED BY : STRUCTURE & Other Observations 400 HAND PENETROMETER (kPa) 300 200 100 DYNAMIC PENETROMETER MOISTURE / WEATHERING SYMBOL MATERIAL DESCRIPTION Soil Type, plasticity or particle characteristic, colour Rock Type, grain size, colour Secondary and minor components CONSISTENCY / REL DENSITY / ROCK STRENGTH 0.0 CLASSIFICATION GRAPHIC LOG DEPTH (m) SAMPLES & FIELD TESTS GROUND WATER LEVELS LOCATION : See Drawing for location TOPSOIL: Silty Clayey SAND; grey, fine to medium grained D L MC > PL VSt MC > PL H XW EL 0.10m Silty CLAY; low to medium plasticity, grey mottled brown, trace fine grained sand Not Encountered 0.5 0.60m Sandy CLAY; low to medium plasticity, grey mottled brown, fine to medium grained sand, with silt GEOTECH_SOLUTIONS_03 LIBRARY.GLB Log CGS_TESTHOLE_LOG_02 CGS_2398_ NORTHLAKES ESTATE STAGES 33 & 34.GPJ 10/10/2014 14:07 8.30.003 1.0 1.10m SANDSTONE: brown 1.20m Testbore TB039 terminated at 1.20 m Refusal on weathered sandstone 1.5 2.0 WATER / MOISTURE SAMPLES & FIELD TESTS CONSISTENCY RELATIVE DENSITY ROCK STRENGTH ROCK WEATHERING D M W OMC PL U D ES B SPT HP VS S F St VSt H VL L MD D VD EL VL L M H VH EH RS XW DW SW FR - Dry Moist Wet Optimum MC Plastic Limit Water inflow See Explanatory Notes for details of abbreviations & basis of descriptions. - Undisturbed Sample Disturbed Sample Environmental sample Bulk Disturbed Sample Standard Penetration Test Hand/Pocket Penetrometer - Very Soft Soft Firm Stiff Very Stiff Hard - Very Loose Loose Medium Dense Dense Very Dense - Extremely low Very low Low Medium High Very high Extremely high - Residual soil Extremely weathered Distinctly weathered Slightly weathered Fresh rock CARDNO GEOTECH SOLUTIONS File: CGS2398 TB039 Page 1 OF 1 CLIENT : Northlakes Pty Ltd C/- McCloy Group PROJECT : Site Classification LOCATION : Stage 33 & 34, Northlakes Estate, Cameron Park TESTBORE LOG HOLE NO : TB040 PROJECT REF : CGS2398 SHEET : 1 OF 1 EQUIPMENT TYPE : 3.5t Excavator METHOD : 300 mm Hydraulic Auger DATE EXCAVATED : 19/9/14 LOGGED BY : KH CHECKED BY : STRUCTURE & Other Observations 400 HAND PENETROMETER (kPa) 300 200 100 DYNAMIC PENETROMETER MOISTURE / WEATHERING SYMBOL MATERIAL DESCRIPTION Soil Type, plasticity or particle characteristic, colour Rock Type, grain size, colour Secondary and minor components CONSISTENCY / REL DENSITY / ROCK STRENGTH 0.0 CLASSIFICATION GRAPHIC LOG DEPTH (m) SAMPLES & FIELD TESTS GROUND WATER LEVELS LOCATION : See Drawing for location FILL: Sandy Gravelly CLAY, low to medium plasticity, brown, fine to medium sub-angular to sub-rounded gravel, fine to coarse grained sand 1 MC = PL 2 2 0.40m FILL: Silty CLAY; low to medium plasticity, brown Not Encountered 0.5 MC = PL 7 0.60m Silty CLAY: low to medium plasticity, brown mottled grey 9 MC = PL VSt XW EL GEOTECH_SOLUTIONS_03 LIBRARY.GLB Log CGS_TESTHOLE_LOG_02 CGS_2398_ NORTHLAKES ESTATE STAGES 33 & 34.GPJ 10/10/2014 14:07 8.30.003 1.0 1.10m SANDSTONE: brown 1.20m Testbore TB040 terminated at 1.20 m Refusal on weathered sandstone 1.5 2.0 WATER / MOISTURE SAMPLES & FIELD TESTS CONSISTENCY RELATIVE DENSITY ROCK STRENGTH ROCK WEATHERING D M W OMC PL U D ES B SPT HP VS S F St VSt H VL L MD D VD EL VL L M H VH EH RS XW DW SW FR - Dry Moist Wet Optimum MC Plastic Limit Water inflow See Explanatory Notes for details of abbreviations & basis of descriptions. - Undisturbed Sample Disturbed Sample Environmental sample Bulk Disturbed Sample Standard Penetration Test Hand/Pocket Penetrometer - Very Soft Soft Firm Stiff Very Stiff Hard - Very Loose Loose Medium Dense Dense Very Dense - Extremely low Very low Low Medium High Very high Extremely high - Residual soil Extremely weathered Distinctly weathered Slightly weathered Fresh rock CARDNO GEOTECH SOLUTIONS File: CGS2398 TB040 Page 1 OF 1 CLIENT : Northlakes Pty Ltd C/- McCloy Group PROJECT : Site Classification LOCATION : Stage 33 & 34, Northlakes Estate, Cameron Park TESTBORE LOG HOLE NO : TB041 PROJECT REF : CGS2398 SHEET : 1 OF 1 EQUIPMENT TYPE : 3.5t Excavator METHOD : 300 mm Hydraulic Auger DATE EXCAVATED : 19/9/14 LOGGED BY : KH CHECKED BY : STRUCTURE & Other Observations 400 HAND PENETROMETER (kPa) 300 200 100 DYNAMIC PENETROMETER MOISTURE / WEATHERING SYMBOL MATERIAL DESCRIPTION Soil Type, plasticity or particle characteristic, colour Rock Type, grain size, colour Secondary and minor components CONSISTENCY / REL DENSITY / ROCK STRENGTH 0.0 CLASSIFICATION GRAPHIC LOG DEPTH (m) SAMPLES & FIELD TESTS GROUND WATER LEVELS LOCATION : See Drawing for location FILL: Silty Sandy CLAY; low plasticity, brown, fine to coarse grained sand, with fine to coarse sub-angular to sub-rounded gravel, trace cobbles 3 4 11 0.5 8 15 Not Encountered MC = PL GEOTECH_SOLUTIONS_03 LIBRARY.GLB Log CGS_TESTHOLE_LOG_02 CGS_2398_ NORTHLAKES ESTATE STAGES 33 & 34.GPJ 10/10/2014 14:07 8.30.003 1.0 1.50m 1.5 Silty CLAY; low plasticity, grey mottled brown, with fine grained sand MC = PL 1.80m Testbore TB041 terminated at 1.80 m Target depth 2.0 WATER / MOISTURE SAMPLES & FIELD TESTS CONSISTENCY RELATIVE DENSITY ROCK STRENGTH ROCK WEATHERING D M W OMC PL U D ES B SPT HP VS S F St VSt H VL L MD D VD EL VL L M H VH EH RS XW DW SW FR - Dry Moist Wet Optimum MC Plastic Limit Water inflow See Explanatory Notes for details of abbreviations & basis of descriptions. - Undisturbed Sample Disturbed Sample Environmental sample Bulk Disturbed Sample Standard Penetration Test Hand/Pocket Penetrometer - Very Soft Soft Firm Stiff Very Stiff Hard - Very Loose Loose Medium Dense Dense Very Dense - Extremely low Very low Low Medium High Very high Extremely high - Residual soil Extremely weathered Distinctly weathered Slightly weathered Fresh rock CARDNO GEOTECH SOLUTIONS File: CGS2398 TB041 Page 1 OF 1 TESTBORE LOG CLIENT : Northlakes Pty Ltd C/- McCloy Group PROJECT : Site Classification LOCATION : Stage 33 & 34, Northlakes Estate, Cameron Park HOLE NO : TB042 PROJECT REF : CGS2398 SHEET : 1 OF 1 EQUIPMENT TYPE : 3.5t Excavator METHOD : 300 mm Hydraulic Auger DATE EXCAVATED : 19/9/14 LOGGED BY : KH CHECKED BY : STRUCTURE & Other Observations 400 HAND PENETROMETER (kPa) 300 200 100 DYNAMIC PENETROMETER MOISTURE / WEATHERING SYMBOL MATERIAL DESCRIPTION Soil Type, plasticity or particle characteristic, colour Rock Type, grain size, colour Secondary and minor components CONSISTENCY / REL DENSITY / ROCK STRENGTH 0.0 CLASSIFICATION GRAPHIC LOG DEPTH (m) SAMPLES & FIELD TESTS GROUND WATER LEVELS LOCATION : See Drawing for location FILL: Sandy Silty CLAY; low to medium plasticity, brown, fine to medium grained sand, with fine to medium sub-angular to sub-rounded gravel 3 2 4 0.5 Not Encountered 7 8 MC = PL 8 7 GEOTECH_SOLUTIONS_03 LIBRARY.GLB Log CGS_TESTHOLE_LOG_02 CGS_2398_ NORTHLAKES ESTATE STAGES 33 & 34.GPJ 10/10/2014 14:07 8.30.003 1.0 15 19 1.40m SANDSTONE: grey mottled brown XW EL 1.50m 1.5 Testbore TB042 terminated at 1.50 m Refusal on weathered sandstone 2.0 WATER / MOISTURE SAMPLES & FIELD TESTS CONSISTENCY RELATIVE DENSITY ROCK STRENGTH ROCK WEATHERING D M W OMC PL U D ES B SPT HP VS S F St VSt H VL L MD D VD EL VL L M H VH EH RS XW DW SW FR - Dry Moist Wet Optimum MC Plastic Limit Water inflow See Explanatory Notes for details of abbreviations & basis of descriptions. - Undisturbed Sample Disturbed Sample Environmental sample Bulk Disturbed Sample Standard Penetration Test Hand/Pocket Penetrometer - Very Soft Soft Firm Stiff Very Stiff Hard - Very Loose Loose Medium Dense Dense Very Dense - Extremely low Very low Low Medium High Very high Extremely high - Residual soil Extremely weathered Distinctly weathered Slightly weathered Fresh rock CARDNO GEOTECH SOLUTIONS File: CGS2398 TB042 Page 1 OF 1 CLIENT : Northlakes Pty Ltd C/- McCloy Group PROJECT : Site Classification LOCATION : Stage 33 & 34, Northlakes Estate, Cameron Park TESTBORE LOG HOLE NO : TB043 PROJECT REF : CGS2398 SHEET : 1 OF 1 EQUIPMENT TYPE : 3.5t Excavator METHOD : 300 mm Hydraulic Auger DATE EXCAVATED : 19/9/14 LOGGED BY : KH CHECKED BY : STRUCTURE & Other Observations 400 HAND PENETROMETER (kPa) 300 200 100 DYNAMIC PENETROMETER MOISTURE / WEATHERING SYMBOL MATERIAL DESCRIPTION Soil Type, plasticity or particle characteristic, colour Rock Type, grain size, colour Secondary and minor components CONSISTENCY / REL DENSITY / ROCK STRENGTH 0.0 CLASSIFICATION GRAPHIC LOG DEPTH (m) SAMPLES & FIELD TESTS GROUND WATER LEVELS LOCATION : See Drawing for location FILL: Clayey Silty SAND; brown, fine to medium grained 3 4 D-M 7 0.50m 0.5 Not Encountered FILL: Clayey Silty SAND; dark brown mottled white, fine to medium grained (or Silty Sandy CLAY) 11 10 MC = PL 8 GEOTECH_SOLUTIONS_03 LIBRARY.GLB Log CGS_TESTHOLE_LOG_02 CGS_2398_ NORTHLAKES ESTATE STAGES 33 & 34.GPJ 10/10/2014 14:07 8.30.003 12 1.00m 1.0 FILL: Silty Sandy CLAY; low plasticity, brown, fine to medium grained sand, with fine gravel 10 MC = PL 15 1.30m Silty CLAY; low plasticity, brown, some organics R MC = PL VSt - H 1.50m 1.5 Testbore TB043 terminated at 1.50 m Refusal 2.0 WATER / MOISTURE SAMPLES & FIELD TESTS CONSISTENCY RELATIVE DENSITY ROCK STRENGTH ROCK WEATHERING D M W OMC PL U D ES B SPT HP VS S F St VSt H VL L MD D VD EL VL L M H VH EH RS XW DW SW FR - Dry Moist Wet Optimum MC Plastic Limit Water inflow See Explanatory Notes for details of abbreviations & basis of descriptions. - Undisturbed Sample Disturbed Sample Environmental sample Bulk Disturbed Sample Standard Penetration Test Hand/Pocket Penetrometer - Very Soft Soft Firm Stiff Very Stiff Hard - Very Loose Loose Medium Dense Dense Very Dense - Extremely low Very low Low Medium High Very high Extremely high - Residual soil Extremely weathered Distinctly weathered Slightly weathered Fresh rock CARDNO GEOTECH SOLUTIONS File: CGS2398 TB043 Page 1 OF 1 Report on Site ClassificationCGS2398-002/0 Northlakes Estate Stage 33 & 34, Cameron Park Prepared for Northlakes Pty Ltd C/- McCloy Group Pty Ltd APPENDIX C CSIRO INFORMATION SHEET BTF 18 CGS2398-002.0 October 2014 Cardno Geotech Solutions 12 Foundation Maintenance and Footing Performance: A Homeowner’s Guide BTF 18 replaces Information Sheet 10/91 Buildings can and often do move. This movement can be up, down, lateral or rotational. The fundamental cause of movement in buildings can usually be related to one or more problems in the foundation soil. It is important for the homeowner to identify the soil type in order to ascertain the measures that should be put in place in order to ensure that problems in the foundation soil can be prevented, thus protecting against building movement. This Building Technology File is designed to identify causes of soil-related building movement, and to suggest methods of prevention of resultant cracking in buildings. Soil Types The types of soils usually present under the topsoil in land zoned for residential buildings can be split into two approximate groups – granular and clay. Quite often, foundation soil is a mixture of both types. The general problems associated with soils having granular content are usually caused by erosion. Clay soils are subject to saturation and swell/shrink problems. Classifications for a given area can generally be obtained by application to the local authority, but these are sometimes unreliable and if there is doubt, a geotechnical report should be commissioned. As most buildings suffering movement problems are founded on clay soils, there is an emphasis on classification of soils according to the amount of swell and shrinkage they experience with variations of water content. The table below is Table 2.1 from AS 2870, the Residential Slab and Footing Code. Causes of Movement Settlement due to construction There are two types of settlement that occur as a result of construction: • Immediate settlement occurs when a building is first placed on its foundation soil, as a result of compaction of the soil under the weight of the structure. The cohesive quality of clay soil mitigates against this, but granular (particularly sandy) soil is susceptible. • Consolidation settlement is a feature of clay soil and may take place because of the expulsion of moisture from the soil or because of the soil’s lack of resistance to local compressive or shear stresses. This will usually take place during the first few months after construction, but has been known to take many years in exceptional cases. These problems are the province of the builder and should be taken into consideration as part of the preparation of the site for construction. Building Technology File 19 (BTF 19) deals with these problems. Erosion All soils are prone to erosion, but sandy soil is particularly susceptible to being washed away. Even clay with a sand component of say 10% or more can suffer from erosion. Saturation This is particularly a problem in clay soils. Saturation creates a boglike suspension of the soil that causes it to lose virtually all of its bearing capacity. To a lesser degree, sand is affected by saturation because saturated sand may undergo a reduction in volume – particularly imported sand fill for bedding and blinding layers. However, this usually occurs as immediate settlement and should normally be the province of the builder. Seasonal swelling and shrinkage of soil All clays react to the presence of water by slowly absorbing it, making the soil increase in volume (see table below). The degree of increase varies considerably between different clays, as does the degree of decrease during the subsequent drying out caused by fair weather periods. Because of the low absorption and expulsion rate, this phenomenon will not usually be noticeable unless there are prolonged rainy or dry periods, usually of weeks or months, depending on the land and soil characteristics. The swelling of soil creates an upward force on the footings of the building, and shrinkage creates subsidence that takes away the support needed by the footing to retain equilibrium. Shear failure This phenomenon occurs when the foundation soil does not have sufficient strength to support the weight of the footing. There are two major post-construction causes: • Significant load increase. • Reduction of lateral support of the soil under the footing due to erosion or excavation. • In clay soil, shear failure can be caused by saturation of the soil adjacent to or under the footing. GENERAL DEFINITIONS OF SITE CLASSES Class Foundation A Most sand and rock sites with little or no ground movement from moisture changes S Slightly reactive clay sites with only slight ground movement from moisture changes M Moderately reactive clay or silt sites, which can experience moderate ground movement from moisture changes H Highly reactive clay sites, which can experience high ground movement from moisture changes E Extremely reactive sites, which can experience extreme ground movement from moisture changes A to P P Filled sites Sites which include soft soils, such as soft clay or silt or loose sands; landslip; mine subsidence; collapsing soils; soils subject to erosion; reactive sites subject to abnormal moisture conditions or sites which cannot be classified otherwise Tree root growth Trees and shrubs that are allowed to grow in the vicinity of footings can cause foundation soil movement in two ways: Trees can cause shrinkage and damage • Roots that grow under footings may increase in cross-sectional size, exerting upward pressure on footings. • Roots in the vicinity of footings will absorb much of the moisture in the foundation soil, causing shrinkage or subsidence. Unevenness of Movement The types of ground movement described above usually occur unevenly throughout the building’s foundation soil. Settlement due to construction tends to be uneven because of: • Differing compaction of foundation soil prior to construction. • Differing moisture content of foundation soil prior to construction. Movement due to non-construction causes is usually more uneven still. Erosion can undermine a footing that traverses the flow or can create the conditions for shear failure by eroding soil adjacent to a footing that runs in the same direction as the flow. Saturation of clay foundation soil may occur where subfloor walls create a dam that makes water pond. It can also occur wherever there is a source of water near footings in clay soil. This leads to a severe reduction in the strength of the soil which may create local shear failure. Seasonal swelling and shrinkage of clay soil affects the perimeter of the building first, then gradually spreads to the interior. The swelling process will usually begin at the uphill extreme of the building, or on the weather side where the land is flat. Swelling gradually reaches the interior soil as absorption continues. Shrinkage usually begins where the sun’s heat is greatest. Effects of Uneven Soil Movement on Structures Erosion and saturation Erosion removes the support from under footings, tending to create subsidence of the part of the structure under which it occurs. Brickwork walls will resist the stress created by this removal of support by bridging the gap or cantilevering until the bricks or the mortar bedding fail. Older masonry has little resistance. Evidence of failure varies according to circumstances and symptoms may include: • Step cracking in the mortar beds in the body of the wall or above/below openings such as doors or windows. • Vertical cracking in the bricks (usually but not necessarily in line with the vertical beds or perpends). Isolated piers affected by erosion or saturation of foundations will eventually lose contact with the bearers they support and may tilt or fall over. The floors that have lost this support will become bouncy, sometimes rattling ornaments etc. Seasonal swelling/shrinkage in clay Swelling foundation soil due to rainy periods first lifts the most exposed extremities of the footing system, then the remainder of the perimeter footings while gradually permeating inside the building footprint to lift internal footings. This swelling first tends to create a dish effect, because the external footings are pushed higher than the internal ones. The first noticeable symptom may be that the floor appears slightly dished. This is often accompanied by some doors binding on the floor or the door head, together with some cracking of cornice mitres. In buildings with timber flooring supported by bearers and joists, the floor can be bouncy. Externally there may be visible dishing of the hip or ridge lines. As the moisture absorption process completes its journey to the innermost areas of the building, the internal footings will rise. If the spread of moisture is roughly even, it may be that the symptoms will temporarily disappear, but it is more likely that swelling will be uneven, creating a difference rather than a disappearance in symptoms. In buildings with timber flooring supported by bearers and joists, the isolated piers will rise more easily than the strip footings or piers under walls, creating noticeable doming of flooring. As the weather pattern changes and the soil begins to dry out, the external footings will be first affected, beginning with the locations where the sun’s effect is strongest. This has the effect of lowering the external footings. The doming is accentuated and cracking reduces or disappears where it occurred because of dishing, but other cracks open up. The roof lines may become convex. Doming and dishing are also affected by weather in other ways. In areas where warm, wet summers and cooler dry winters prevail, water migration tends to be toward the interior and doming will be accentuated, whereas where summers are dry and winters are cold and wet, migration tends to be toward the exterior and the underlying propensity is toward dishing. Movement caused by tree roots In general, growing roots will exert an upward pressure on footings, whereas soil subject to drying because of tree or shrub roots will tend to remove support from under footings by inducing shrinkage. Complications caused by the structure itself Most forces that the soil causes to be exerted on structures are vertical – i.e. either up or down. However, because these forces are seldom spread evenly around the footings, and because the building resists uneven movement because of its rigidity, forces are exerted from one part of the building to another. The net result of all these forces is usually rotational. This resultant force often complicates the diagnosis because the visible symptoms do not simply reflect the original cause. A common symptom is binding of doors on the vertical member of the frame. Effects on full masonry structures Brickwork will resist cracking where it can. It will attempt to span areas that lose support because of subsided foundations or raised points. It is therefore usual to see cracking at weak points, such as openings for windows or doors. In the event of construction settlement, cracking will usually remain unchanged after the process of settlement has ceased. With local shear or erosion, cracking will usually continue to develop until the original cause has been remedied, or until the subsidence has completely neutralised the affected portion of footing and the structure has stabilised on other footings that remain effective. In the case of swell/shrink effects, the brickwork will in some cases return to its original position after completion of a cycle, however it is more likely that the rotational effect will not be exactly reversed, and it is also usual that brickwork will settle in its new position and will resist the forces trying to return it to its original position. This means that in a case where swelling takes place after construction and cracking occurs, the cracking is likely to at least partly remain after the shrink segment of the cycle is complete. Thus, each time the cycle is repeated, the likelihood is that the cracking will become wider until the sections of brickwork become virtually independent. With repeated cycles, once the cracking is established, if there is no other complication, it is normal for the incidence of cracking to stabilise, as the building has the articulation it needs to cope with the problem. This is by no means always the case, however, and monitoring of cracks in walls and floors should always be treated seriously. Upheaval caused by growth of tree roots under footings is not a simple vertical shear stress. There is a tendency for the root to also exert lateral forces that attempt to separate sections of brickwork after initial cracking has occurred. The normal structural arrangement is that the inner leaf of brickwork in the external walls and at least some of the internal walls (depending on the roof type) comprise the load-bearing structure on which any upper floors, ceilings and the roof are supported. In these cases, it is internally visible cracking that should be the main focus of attention, however there are a few examples of dwellings whose external leaf of masonry plays some supporting role, so this should be checked if there is any doubt. In any case, externally visible cracking is important as a guide to stresses on the structure generally, and it should also be remembered that the external walls must be capable of supporting themselves. Effects on framed structures Timber or steel framed buildings are less likely to exhibit cracking due to swell/shrink than masonry buildings because of their flexibility. Also, the doming/dishing effects tend to be lower because of the lighter weight of walls. The main risks to framed buildings are encountered because of the isolated pier footings used under walls. Where erosion or saturation cause a footing to fall away, this can double the span which a wall must bridge. This additional stress can create cracking in wall linings, particularly where there is a weak point in the structure caused by a door or window opening. It is, however, unlikely that framed structures will be so stressed as to suffer serious damage without first exhibiting some or all of the above symptoms for a considerable period. The same warning period should apply in the case of upheaval. It should be noted, however, that where framed buildings are supported by strip footings there is only one leaf of brickwork and therefore the externally visible walls are the supporting structure for the building. In this case, the subfloor masonry walls can be expected to behave as full brickwork walls. Effects on brick veneer structures Because the load-bearing structure of a brick veneer building is the frame that makes up the interior leaf of the external walls plus perhaps the internal walls, depending on the type of roof, the building can be expected to behave as a framed structure, except that the external masonry will behave in a similar way to the external leaf of a full masonry structure. Water Service and Drainage Where a water service pipe, a sewer or stormwater drainage pipe is in the vicinity of a building, a water leak can cause erosion, swelling or saturation of susceptible soil. Even a minuscule leak can be enough to saturate a clay foundation. A leaking tap near a building can have the same effect. In addition, trenches containing pipes can become watercourses even though backfilled, particularly where broken rubble is used as fill. Water that runs along these trenches can be responsible for serious erosion, interstrata seepage into subfloor areas and saturation. Pipe leakage and trench water flows also encourage tree and shrub roots to the source of water, complicating and exacerbating the problem. Poor roof plumbing can result in large volumes of rainwater being concentrated in a small area of soil: • Incorrect falls in roof guttering may result in overflows, as may gutters blocked with leaves etc. • Corroded guttering or downpipes can spill water to ground. • Downpipes not positively connected to a proper stormwater collection system will direct a concentration of water to soil that is directly adjacent to footings, sometimes causing large-scale problems such as erosion, saturation and migration of water under the building. Seriousness of Cracking In general, most cracking found in masonry walls is a cosmetic nuisance only and can be kept in repair or even ignored. The table below is a reproduction of Table C1 of AS 2870. AS 2870 also publishes figures relating to cracking in concrete floors, however because wall cracking will usually reach the critical point significantly earlier than cracking in slabs, this table is not reproduced here. Prevention/Cure Plumbing Where building movement is caused by water service, roof plumbing, sewer or stormwater failure, the remedy is to repair the problem. It is prudent, however, to consider also rerouting pipes away from the building where possible, and relocating taps to positions where any leakage will not direct water to the building vicinity. Even where gully traps are present, there is sometimes sufficient spill to create erosion or saturation, particularly in modern installations using smaller diameter PVC fixtures. Indeed, some gully traps are not situated directly under the taps that are installed to charge them, with the result that water from the tap may enter the backfilled trench that houses the sewer piping. If the trench has been poorly backfilled, the water will either pond or flow along the bottom of the trench. As these trenches usually run alongside the footings and can be at a similar depth, it is not hard to see how any water that is thus directed into a trench can easily affect the foundation’s ability to support footings or even gain entry to the subfloor area. Ground drainage In all soils there is the capacity for water to travel on the surface and below it. Surface water flows can be established by inspection during and after heavy or prolonged rain. If necessary, a grated drain system connected to the stormwater collection system is usually an easy solution. It is, however, sometimes necessary when attempting to prevent water migration that testing be carried out to establish watertable height and subsoil water flows. This subject is referred to in BTF 19 and may properly be regarded as an area for an expert consultant. Protection of the building perimeter It is essential to remember that the soil that affects footings extends well beyond the actual building line. Watering of garden plants, shrubs and trees causes some of the most serious water problems. For this reason, particularly where problems exist or are likely to occur, it is recommended that an apron of paving be installed around as much of the building perimeter as necessary. This paving CLASSIFICATION OF DAMAGE WITH REFERENCE TO WALLS Description of typical damage and required repair Hairline cracks Approximate crack width limit (see Note 3) Damage category <0.1 mm 0 Fine cracks which do not need repair <1 mm 1 Cracks noticeable but easily filled. Doors and windows stick slightly <5 mm 2 Cracks can be repaired and possibly a small amount of wall will need to be replaced. Doors and windows stick. Service pipes can fracture. Weathertightness often impaired 5–15 mm (or a number of cracks 3 mm or more in one group) 3 15–25 mm but also depend on number of cracks 4 Extensive repair work involving breaking-out and replacing sections of walls, especially over doors and windows. Window and door frames distort. Walls lean or bulge noticeably, some loss of bearing in beams. Service pipes disrupted • Water that is transmitted into masonry, metal or timber building elements causes damage and/or decay to those elements. • High subfloor humidity and moisture content create an ideal environment for various pests, including termites and spiders. • Where high moisture levels are transmitted to the flooring and walls, an increase in the dust mite count can ensue within the living areas. Dust mites, as well as dampness in general, can be a health hazard to inhabitants, particularly those who are abnormally susceptible to respiratory ailments. Gardens for a reactive site The garden The ideal vegetation layout is to have lawn or plants that require only light watering immediately adjacent to the drainage or paving edge, then more demanding plants, shrubs and trees spread out in that order. Overwatering due to misuse of automatic watering systems is a common cause of saturation and water migration under footings. If it is necessary to use these systems, it is important to remove garden beds to a completely safe distance from buildings. Existing trees Where a tree is causing a problem of soil drying or there is the existence or threat of upheaval of footings, if the offending roots are subsidiary and their removal will not significantly damage the tree, they should be severed and a concrete or metal barrier placed vertically in the soil to prevent future root growth in the direction of the building. If it is not possible to remove the relevant roots without damage to the tree, an application to remove the tree should be made to the local authority. A prudent plan is to transplant likely offenders before they become a problem. Information on trees, plants and shrubs State departments overseeing agriculture can give information regarding root patterns, volume of water needed and safe distance from buildings of most species. Botanic gardens are also sources of information. For information on plant roots and drains, see Building Technology File 17. should extend outwards a minimum of 900 mm (more in highly reactive soil) and should have a minimum fall away from the building of 1:60. The finished paving should be no less than 100 mm below brick vent bases. It is prudent to relocate drainage pipes away from this paving, if possible, to avoid complications from future leakage. If this is not practical, earthenware pipes should be replaced by PVC and backfilling should be of the same soil type as the surrounding soil and compacted to the same density. Except in areas where freezing of water is an issue, it is wise to remove taps in the building area and relocate them well away from the building – preferably not uphill from it (see BTF 19). It may be desirable to install a grated drain at the outside edge of the paving on the uphill side of the building. If subsoil drainage is needed this can be installed under the surface drain. Condensation In buildings with a subfloor void such as where bearers and joists support flooring, insufficient ventilation creates ideal conditions for condensation, particularly where there is little clearance between the floor and the ground. Condensation adds to the moisture already present in the subfloor and significantly slows the process of drying out. Installation of an adequate subfloor ventilation system, either natural or mechanical, is desirable. Warning: Although this Building Technology File deals with cracking in buildings, it should be said that subfloor moisture can result in the development of other problems, notably: Excavation Excavation around footings must be properly engineered. Soil supporting footings can only be safely excavated at an angle that allows the soil under the footing to remain stable. This angle is called the angle of repose (or friction) and varies significantly between soil types and conditions. Removal of soil within the angle of repose will cause subsidence. Remediation Where erosion has occurred that has washed away soil adjacent to footings, soil of the same classification should be introduced and compacted to the same density. Where footings have been undermined, augmentation or other specialist work may be required. Remediation of footings and foundations is generally the realm of a specialist consultant. Where isolated footings rise and fall because of swell/shrink effect, the homeowner may be tempted to alleviate floor bounce by filling the gap that has appeared between the bearer and the pier with blocking. The danger here is that when the next swell segment of the cycle occurs, the extra blocking will push the floor up into an accentuated dome and may also cause local shear failure in the soil. If it is necessary to use blocking, it should be by a pair of fine wedges and monitoring should be carried out fortnightly. This BTF was prepared by John Lewer FAIB, MIAMA, Partner, Construction Diagnosis. The information in this and other issues in the series was derived from various sources and was believed to be correct when published. The information is advisory. It is provided in good faith and not claimed to be an exhaustive treatment of the relevant subject. Further professional advice needs to be obtained before taking any action based on the information provided. Distributed by C S I R O P U B L I S H I N G PO Box 1139, Collingwood 3066, Australia Freecall 1800 645 051 Tel (03) 9662 7666 Fax (03) 9662 7555 www.publish.csiro.au Email: [email protected] © CSIRO 2003. Unauthorised copying of this Building Technology file is prohibited
© Copyright 2024