Food Weighing and solutions Analysis inin the Analytical the Laboratory laboratory Easy Measurement of Tomato Paste A globally famous food supplier manufactures tomato paste and tomato products and distributes worldwide. In its quality test lab, METTLER TOLEDO’s DL22 Food & Beverage Analyzer plays an important role in analyzing the nutrition content of potato paste accurately, efficiently and safely. Challenges in Measurement Tomato is rich in nutrition and has multiple uses. Its vitamin C is beneficial to the human body and raises its capability to resist cancer. Tomato paste is a condensed fresh tomato product with a bright red color. It’s often used as the basis for making ketchup or reconstituted tomato juice. Traditionally, tomato paste is tested through manual titration. This method is prone to errors due to the characteristic of paste itself and the skill of operators. End points are judged visually from the color change on the indicator. However, the bright red color of the paste may interfere with accurate judgment. Tailor-Made for Food Industry The DL22 Food & Beverage Analyzer from METTLER TOLEDO is a specialized titrator for the food and beverage industry. It overcomes all the uncertainties which arise from manual titration. It is based on the principle of potentiometric titration which detects potential sudden change that indicate that the end point has been reached, free from solution color interference. There are several other advantages. Samples can be fully dissolved and mixed for optimal measuring results thanks to the DL22’s propeller and magnetic stirring functions. Titrant dispensed is controlled by a motor-driven dosing unit and pushed by a piston. As lifting distance can be controlled precisely with mechanical technique, the minimal adding precision of titrant can reach ±0.0001mL. The result 3 News Titration is automatically calculated by the instrument in order to avoid transcript errors. Tailor-Made for Food Industry Lab operators praise the high efficiency of the DL22, “All we need to do is start the selected method and go on to perform other tasks,” said one technician. “All the end results are printed automatically. No more tedious calculation works.” The DL22 analyzer provides preprogrammed test methods developed for food and beverage industry requirements, i.e. applications including total acid, reducing sugar, vitamin C, chloride content and pH value. “Previously, samples had to be kept in boiling status in order to complete the titration. The operators were exposed to risks of being burnt.” said the operators who are responsible for detecting the reducing sugar content. “Now, we only need to press the ‘Run’ button and the rest is carried out automatically.” The laboratory director also points out, “We highly appreciate the password protection function ensuring that only an authorized person can alter the different titration methods.” Featuring reliability, efficiency and safety, the DL22 analyzer makes the different testing requirements of tomato paste easier and more professional. www.mt.com/dl22FB Know-how Learn more about analytical chemical applications UserCom 13, the user magazine, provides valuable information about the following topics: • Customer Reports • Applications • Expert Tips • New Products Download free UserCom 13 www.mt.com/AC-UserCom13 Publisher Mettler-Toledo AG Laboratory Division Im Langacher CH-8606 Greifensee, Switzerland Production Segment Marketing LAB Global MarCom Switzerland Subject to technical changes. © Mettler-Toledo AG 08/09 Printed in Switzerland. 2 METTLER TOLEDO FoodNews 3 Reliable Sugar Production Meeting Customer Expectations Every autumn 10 000 tons of sugar beets are delivered to the Frauenfeld sugar plant daily from which 125 000 tons of sugar are produced annually. Such a high throughput along with a harsh production environment presents real challenges for much of the equipment used. The METTLER TOLEDO precision balances and laboratory instruments used in the quality control laboratory have successfully overcome these challenges. highly accurate sample weight reading for exact final sugar content determination. Further precision balances are used to weigh the reagents and during the preparation of standards. Sugar beets. Checking the Sugar Content The sugar beet is tested in an incoming control laboratory upon delivery from the fields. As farmers are paid according to the quality of sugar beet delivered, the beet sugar content must be determined. This initial testing process mimics the actual production process, although on a much smaller scale. In Frauenfeld, the whole process is fully automated. A METTLER TOLEDO GB1302 Precision Balance (of 1310 g capacity and 0.01g readability) is integrated into the system to provide a Sweet Quality Control Following production, the sugar is tested in the QC laboratory working to GLP quality standards. Seven technicians in the QC laboratory use in-house SOPs to test the sugar for color determination. As well as using METTLER TOLEDO balances and pH meters, the Frauenfeld sugar plant also uses an HB43-S Moisture Analyzer. The moisture content of the final sugar should not exceed 0.04%. HB43-S Moisture Analyzer is used to determine the moisture content of final sugar. By employing a comprehensive array of analytical methods and sophisticated laboratory equipment, the Frauenfeld plant ensures that their sugar fulfils customers’ high expectations. www.mt.com/excellence-precision www.mt.com/sugarMA A METTLER TOLEDO precision balance is integrated into an automatic sugar content determination process. Quality is Written in Capitals The head of quality control at the Frauenfeld sugar plant, Dr. Gabriele Schober, praised the performance of the METTLER TOLEDO balances under difficult operating environments including: humidity, high temperature and the strong vibrations caused by the conveyor belt transportation of sugar beet for large scale production. Apart from their robustness, METTLER TOLEDO instruments are also outstanding for their accuracy, efficiency and reliability. METTLER TOLEDO FoodNews 3 3 Karl Fischer Titration V30 Karl Fischer Guarantees Unique Nutella Taste The unique taste of Nutella is guarantee by a secret recipe but also by constant quality control. One of the most important parameters to be monitored is the water content, which is carried out using a volumetric Karl Fischer titrator from METTLER TOLEDO. Water Content: a Practical Problem Ferrero is one of the biggest confectionary companies in the world with more than 20 000 employees and 15 production plants. Among many well known products, one of the most popular is Nutella, a delicious cream consisting of chocolate and nuts in a unique, fantastic taste combination. The Problem Solver This is a thing of the past with the new METTLER TOLEDO V30 Volumetric Karl Fischer. It is now possible to connect a high-speed homogenizer, activated automatically by the instrument that assures the complete dissolution of the sample so that water is completely available for the titration. Thanks to this, toxic solvents previously used are no longer necessary. Thanks to the shortcuts of the exclusive ‘One Click Water Titration’ concept and to the new Solvent Manager™ device, the replacement of the titrated liquid with fresh solvent in the titration beaker can’t be easier. The operators have only to press a button on the instrument’s touchscreenand that’s all. No one comes into contact with any dangerous chemical substances. Dr. Jan Pierre Studer, the QC responsible, says, ‘With METTLER TOLEDO we have a long history of cooperation. We know we can count on their simple-to-use and reliable instruments and the expertise of their technicians both in pre- and after sales support. With the V30, the water determinations are now more secure than ever.” www.mt.com/Karl-Fischer The water content in raw materials and products is crucial for quality. Too much water can cause problems in production and storage. For these reasons, the QC lab of Ferrero in Alba, northwestern Italy, needs to know its exact content. Many samples are not soluble in methanol and thus chloroform must be used as an additional solvent to ensure the complete sample’s dissolution. This solvent, and others eventually needed as auxiliary medium for Karl Fischer titrations, are very often toxic and particular care is needed by the operators handling them. 4 METTLER TOLEDO FoodNews 3 V30 Volumetric Karl Fischer Titrator with Solvent ManagerTM. Enhancing the Quality of Peanuts with Thermal Analysis The selection of raw materials and the roasting process are important aspects that influence the manufacturing and production of high quality peanuts. Over-roasting or under-roasting can significantly affect the color, flavor, texture and shelf-life of the end product. Nowadays, optimization of the roasting process and quality control of peanuts can be easily achieved by differential scanning calorimetry (DSC). Analyzing the Roasting Process of Peanuts Peanuts were grated into fine powder and filled into medium pressure crucibles. The same amount of weight in water was added and the crucibles were sealed. Evaluation of DSC curves indicates that temperatures in the range of 149-163 °C for 5 to 8 minutes are required for optimum finishedproduct texture, flavor and color. The optimum temperature and time conditions were established by determining the effect oil-roasting has on the peanut’s levels of residual undenatured arachin and nonarachin protein fractions (Figure 1). The DSC curves in Figure 1 show evaluations for blanched and roasted peanuts respectively. The heating curves of blanched peanuts exhibit a small starch gelatinization endotherm at 80°C. This indicates that some gelatinization has already occurred during blanching. However, the denaturation peaks for nonarachin and arachin at 98 and 113°C, respectively, suggesting that blanching has not resulted in any significant protein denaturation. In comparison, roasting would result in a smaller residual starch gelatinization peak, the absence of the non-arachin peak and a broadened arachin peak which is significantly reduced in size. This indicates that arachin is partially denatured, due to over-roasting at too high a temperature. Figure 1: DSC curves for blanched and roasted peanuts. Differential scanning calorimetry is a fast and easy technique that can be used to establish criteria for the optimization of raw material selection and the roasting process of peanuts. The DSC 1 profiles provide valuable information on the temperature and time conditions required for optimum texture, flavor and color as well as determining the effect oil-roasting has on the undenatured nonarachin and arachin proteins of the peanut. The DSC 1 is an extremely useful instrument for quality control, research and development and, ultimately, for satisfying consumer expectations. DSC 1 www.mt.com/dsc METTLER TOLEDO FoodNews 3 5 Pipette Tips 100% Inert Pipette Tips a Necessary Ingredient For food manufacturers, it is vital that quality control processes are not contaminated by the equipment in use including pipette tips. Highperformance tips need to be free of any bioactive components, be it from external contamination or the plastic itself. From raw material selection and clean production to safe packaging, RAININ’s 100% inert BioClean™ tips are the purest and safest on the market. Many products on the market are labeled as 100% contamination-free or sterile, but recent publications[1] show that even these tips can compromise the outcome of scientific work. How Plastic Labware can Influence your Experiments Results can be affected by additives in the virgin polypropylene, such as the detergent DiHEMDA and releasing agent oleamide, commonly used by manufacturers of pipette tips. These bioactive components can adversely affect the outcome of experiments. RAININ’s BioClean Tips have been proven to be free of such components and therefore have zero interference on results. RAININ BioClean™ – 100% Clean, 100% Pure BioClean tips from RAININ show no traces of such additives or bioactive contaminants, in internal quality controls and external audits. • Proven absence of bioactive components in the materials • Proven lack of external contaminates (DNA, DNAse, RNAse, ATP, Pyrogens, PCR Inhibitors) Contaminants Tested Testing Detection Levels RNase ≤ 10-9 Kunitz units/μl DNase ≤ 10-7 Kunitz units/μl DNA < 1 copy human DNA Pyrogens (LAL test) 0.001 EU/ml ATP < 10-12 mg/μl Trace Materials No trace metals Trace Organics No organic contaminants [1] McDonald, G., Hudson, A., Dunn, S., You, H., Baker, G., Whittal, R., Martin, J., Jha, A., Edmondson, D., and A. Holt. 2008. Bioactive Contaminants Leach from Disposable Laboratory Plasticware. Science 322 (5903): 917. [2] CFR Title 21 (2003) 177.1520 (a), (b) and (c) 1.1, Basell Polyolefins Datasheet. 6 METTLER TOLEDO FoodNews 3 RAININ BioClean tips are completely inert and do not influence experimental outcomes in any way. RAININ BioClean tips are a safe investment for your lab performance. Maximum Performance with Zero Interference • The Purest Material • Clean Production and Packaging • Best Tested for Maximum Safety www.mt.com/bioclean Medical steam sterilizer. Tips & Tricks Innovative Solutions for Moisture Control in Food Immediate Productivity, Thanks to a ‘Built-In’ Method Library Farmdale Creamery in San Bernardino, California, is using METTLER TOLEDO’s HB43-S Halogen Moisture Analyzer for in-process monitoring of moisture content during cheese production. With the built-in ‘plug and play’ applications the moisture analyzer has more than 100 established methods at hand. Monitoring Vat-to-Vat Variation Farmdale Creamery produces cheese, buttermilk and sour cream at its San Bernardino cultured dairy plant and uses the HB43-S Moisture Analyzer to monitor vatto-vat variation during production. The system’s built-in application methods and compact size make it ideal for this role as explains Ms. Shannon Shunk, QA manager at Farmdale, “The HB43-S Analyzer is a straightforward and reliable instrument, robust enough to cope with the production environment. For our application, it offers rapid moisture analysis, and provides reproducible results in just 5 to 8 minutes.” Clear operating instructions on the display and the chemical-free procedure ensure safe and error-free measurements under all conditions. Quick and Simple Method Development The integrated method library has been designed by METTLER TOLEDO with the specific needs of the food industry in mind. All the methods that can be activated on the HB43-S Analyzer correspond to official reference methods in food analysis and can Wherever quality and shelf-life depend on moisture content, fast and accurate moisture analyses are vital. The 100 tried-and-tested food methods documented in the method library provide valuable information for accurate and fast food testing. Sign up and request the valuable food methods: www.mt.com/foodMA be easily fine-tuned to the user’s requirements. Ms. Shunk confirms how method development has been greatly simplified, “The built-in plug and play applications are a real benefit of this instrument providing established baseline methodologies for many food analysis functions. Overall, the HB43-S Analyzer is a very user-friendly instrument, and consistently does exactly what we need it to.” HB43-S Moisture Analyzer METTLER TOLEDO FoodNews 3 7 Online Tools Use www.mt.com as a Work Efficiency Resource Quick results with application notes METTLER TOLEDO Application Data Sheet for Moisture Determination Using the Halogen Moisture Analyzer This data sheet contains details of Halogen Moisture Analyzer settings for drying coffee cream. These settings enable you to develop your own drying method. The settings must be checked individually and adapted to the relevant sample. The reference method data enables you to make comparisons with the Halogen Moisture Analyzer method. Moisture Determination Method for Coffee Cream Description/material properties Valflora coffee cream UHT, 0.25 l TetraPak, Migros We offer comprehensive application support for weighing, moisture analysis, titration and many other analytical methods. Our titration application database alone holds over 300 applications for each relevant industry segment. e.g. Titration Applications: www.mt.com/titration_applications Reference Method: Oven Accessories METTLER TOLEDO AX205 DR balance, oven, aluminum pans, pipette, desiccator with silica gel, sea sand, small glass stirrer, spoon Sample preparation/procedure Pre-dry the aluminum pans with 20 g of sea sand and a small glass stirrer in the oven (1 hour at 110°C) and then leave to cool in the desiccator. Using the pipette, place the cream in the pre-weighed aluminum pans and stir well. Leave the samples to thicken in the oven for 30 mins at 90°C, then start drying them at 103°C in the oven. Remove the contents after the preset drying time has elapsed, leave to cool in the desiccator and weigh. Repeat the process until mass constancy is achieved. Sample weight: 4 [g] Drying temperature: 103 [°C] Drying times: 3/1/1 [hour(s)] Moisture content (average of 6 measurements): 77.67 [%] Standard deviation: 0.30 [%] Important notes/bibliography Literature: Schweizerisches Lebensmittelbuch (Swiss Food Book) (Issue 5), 3A / 03 Tips & tricks for daily work improvements www.mt.com offers a great deal of background information on techniques, such as weighing processes, in addition to tips and tricks on how to improve your results. Our UserCom magazines offer many examples of how to carry out better and more efficient working practice. e.g. Good Weighing Practice: www.mt.com/GWP e.g. Thermal Analysis UserCom: www.mt.com/ta-usercoms 8 METTLER TOLEDO FoodNews 3 e.g. Moisture Applications: www.mt.com/moisture-methods Learn new techniques with little time or effort in our webinars You can join a wide array of webinars to gain knowledge about various topics from process optimization and applications to advanced techniques. e.g. Automated Chemistry Webinars: www.mt.com/ac-webinars e.g. Thermal Analysis Webinars: www.mt.com/ta-webinars Get the right help to fix problematic issues quickly We offer tools which interactively troubleshoot common issues with lab equipment, such as electrodes for example. Electrode Diagnosis Cockpit: www.mt-electrode.com Download comprehensive documentation We offer manuals and other documents related to our products and your business including various information supporting your equipment qualification needs. e.g. Balance Instruction Manuals: Find corresponding manuals on our product page e.g. Conformity Documents: Find corresponding manuals on our product page METTLER TOLEDO FoodNews 3 9 G20 Compact Titrator Intelligent Solutions for Incoming Inspection and Quality Control The new G20 Compact Titrator combines simplicity and dependability for the food industry in one instrument. The G20 is especially designed for basic applications and can be simply operated due to the well established unique One Click™ user interface and the Plug & Play accessory concept. Automate up to 9 samples with the automated Rondolino titration stand whilst LabX light titration laboratory PC software offers data reliability and comprehensive documentation. Dependable Operation Plug & Play The burette and sensor automatically identify and reduce any errors during installation. One Click Titration™ Shortcuts The One Click™ user interface offers four shortcuts for an immediate operation start. Every user has personalized screen, shortcuts and operation language. 10 METTLER TOLEDO FoodNews 3 Easy Automation Compact Sample Changer Analyze up to 9 samples automatically with the Rondolino Sample Changer. www.mt.com/G20-Titrator Daily preparation of solutions or formulations require efficient weighing solutions without compromise. With the Excellence Plus Precision Balances the weighing process can be significantly improved. Full compliance Full regulatory compliance is easily achieved with the XP Precision Balances' innovative QM tools which warn, remind and protect. That’s the weigh The XP Precision Balances provide outstanding measurement performance and process security for – optimum weighing productivity. Designed to be cleaned Thanks to its straightforward design with large, flat surfaces and removable terminal, the robust XP Precision Balance is fast and easy to clean. www.mt.com/XP-precision METTLER TOLEDO FoodNews 3 11 Spotlight on Promotion Get e e r F Save Time and Money with ErgoClips ips* l C o g r E Say goodbye to the traditional weighing process using weighing papers. • One step dosing directly into the tare container eliminates transfer errors and saves money by minimizing sample loss. • The ErgoClips safer dosing method substantially reduces contamination risks, enables fast dosing processes and increases productivity. ErgoClips can be easily assembled on all XP/XS Excellence Analytical and Micro Balances. For more information, visit www.mt.com/ergoclips *Get 3 ErgoClips free with each XP/XS Analytical Balance order!! Contact your local representatives for detailed information. Mettler-Toledo AG Laboratory Division Im Langacher CH-8606 Greifensee, Switzerland www.mt.com For more information
© Copyright 2024