RE920S Manual - Resolution Products

Picture
Integrated
Z-wave Capability
Ethernet
Card
Status LEDs
RE920S-03-00 IP Communicator with Z-wave
Revert to
Factory
Default Button
Features
•
Connects panels to Ethernet
•
Compatible with:
o
Simon XT
o
Simon XTi
•
Enables:
o
Alarm Reporting
o
Interactive Control Functions
o
Ethernet data reliability
o
Z-Wave Communicator included
Key Instructions
• The same unit works for Simon XT & Simon XTi.
• RE920S mounts inside the Simon XT panel and communicates with the
Simon XT and Simon XTi via the Expansion Connector
• Contains RF Module label – must be affixed to exterior of panel
enclosure.
Ethernet
Connector
Operation
Event Reporting:
Events are reported to both the CMS monitoring receiver and the
SiteControl interactive server. All events use Contact ID reporting codes.
The following events are reported by default:
Alarms
Alarm cancels
Openings
Closings
System Low Battery
System Low Battery Restoral
AC Power Fail
AC Power Restoral
LEDs
Interactive Control:
Four LEDs on the Ethernet card itself indicate the status of the card and its
connections.
The system may be controlled remotely through the SiteControl
interactive platform.
Z-Wave
Ethernet LEDs
Indication
Z-Wave devices can be controlled via the Interactive function.
Power
On and pulsing once per second when the board is powered and
running
Local
On when the unit is registered with the local ethernet router
CS
On when the connection to the CMS central station is established
Platform
On when the connection to the SiteControl interactive server is
established
Siren (RE116-C)
Can be used with a Simon XT
Future: Simon XTi
Revert to Factory Default Button
Press and hold for 5 seconds: Resets the board and keeps all settings
Press and hold for 10 seconds: Reverts board back to the factory default settings
RE920S_IP Communicator
Page 1 of 4
24-Hour Tech Support Line: (715)808-0164
www.ResolutionProducts.com
16-Jan-15
RE920S_IP Communicator
Page 2 of 4
24-Hour Tech Support Line: (715)808-0164
www.ResolutionProducts.com
16-Jan-15
Programming:
1) Refer to server setup instructions and set up the account on the Site Control
Dealer Portal.
2) Disarm the system.
Specifications
Current Draw:
Temperature Range:
Board dimensions:
130 mA Nominal
0F to 120F
2x4x1/2 inches
Specifications subject to change without notice.
3) Power down the GE Simon XT system.
4) Plug RE920S into the back of the GE Simon XT control panel. (Picture below)
board communicates via the Expansion Connector.
GE Simon XT Firmware Version Compatibility
1.3 (minimum)
5) Connect an Ethernet cable to the local router and connect it to the RE920S.
6) Apply power to the GE Simon XT system.
Notices
7) The keypad should display “Resolution TCP\IP Module”.
“GE”, “Honeywell”, “DSC”, “2GIG” and “Napco” are trademarks owned by General Electric
Company, Honeywell International Inc., Tyco Safety Products Canada LTD, 2GIG Technologies
Inc., and NAPCO Security Systems, Inc., respectively.
8) Installation is complete.
Resolution Products, Inc. products will function with one of either GE, Honeywell, DSC or
Napco systems. However, no Resolution product is produced by, endorsed by, nor is officially
associated with GE, Honeywell, DSC or Napco. Resolution recommends verifying proper
enrollment and operation, per control panel installation instructions, at installation.
IP Communicator
in the
Expansion Connector
Warranty
Resolution Products, Inc. will replace products that are defective in their first five (5) years.
FCC Notice
This device complies with Part 15 of the FCC rules. Operation is subject to the
following two conditions:
This device may not cause harmful interference.
This device must accept any interference that may be received, including
interference that may cause undesired operation.
Changes or modifications not expressly approved by the Resolution Products, Inc. could
void the user's authority to operate this equipment.
FCC ID: U5X-RE920A
IC Notice
This device complies with Industry Canada license-exempt RSS standard(s). Operation is
subject to the following two conditions:
(1)This device may not cause interference, and
(2)This device must accept any interference, including interference that may
cause undesired operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils
radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes :
(1)l'appareil ne doit pas produire de brouillage, et
(2)l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi,
même si le brouillage est susceptible d'en compromettre le fonctionnement.
IC: 8310A-RE920A
RE920S_IP Communicator
Page 3 of 4
24-Hour Tech Support Line: (715)808-0164
www.ResolutionProducts.com
16-Jan-15
RE920S_IP Communicator
Page 4 of 4