INVITATION TO BID Jaffrey-Rindge Cooperative School District SAU #47 ELEVATOR MODERNIZATION AND UPGRADES Jaffrey Grade School, Jaffrey Middle School, Conant High School The Jaffrey-Rindge Cooperative School District is requesting sealed bids for the replacement of elevator controls and other specified components for three (3) elevators within the school district. Sealed bids will be accepted until 11 am on Thursday, April 29, 2015. Any variance to the bid specifications must be specifically noted in your response. All elevator replacement parts and labor must be installed after July 1, 2015 and completed on or before August 28, 2015. Mail your sealed bid to: Jaffrey-Rindge Cooperative School District Elevator Modernization Bid 81 Fitzgerald Drive, Unit 2 Jaffrey, NH 03452 A mandatory pre-proposal walk-through will be held at 3:00p.m. on Wednesday, April 22, 2015. Interested bidders should meet in the main office of Conant High School, 3 Conant Way, Jaffrey, NH. The winning bid will be chosen on its merit consisting of cost, bidder’s reputation, references, and the ability to meet the District’s time schedule, service after-the-fact and the best all-around interest to the Jaffrey-Rindge Cooperative School District. The Jaffrey-Rindge School Board reserves the right to reject any or all bids and to accept that bid which appears to be in the best interest of the district, even if the bid is not the lowest price. The board reserves the right to waive any formalities in, or reject, any or all bids or any part of any bid. Any bid may be withdrawn prior to the scheduled time for the opening of bids. Any bid received after the time and date specified shall not be considered. The board also reserves the right to negotiate with a bidder when all bids exceed the budgeted appropriation. For additional information concerning this bid, please contact: Bill Sudsbury, Facilities Manager, Jaffrey-Rindge Cooperative School District, 81 Fitzgerald Drive, Unit 2, Jaffrey, NH 03452, (603) 532-8100 x 260, [email protected]. Conant High School Replace existing controller with a new non-proprietary control system. The motor starter shall be solid state. The controls shall operate in selective collective operation, and shall include independent service, as well as fire service operation. Replace the car operating panel with a new panel that includes integral emergency lighting, and ADA phone. Replace hall call stations with new fixtures. Replace the door operators with new closed loop GAL MOVFR operator’s Replace the existing pumping unit with a new submersible type pumping unit. Install new Infrared detector on both doors if not already installed. The elevator shall be made fire code compliant, including all necessary wiring for and including circuitry for the operation of smoke detectors. The owner will have the fire detection devices installed by others. Jaffrey-Rindge Middle School Replace existing controller with a new non-proprietary control system. The motor starter shall be solid state. The controls shall operate in selective collective operation, and shall include independent service, as well as fire service operation. Replace the car operating panel with a new panel that includes integral emergency lighting, and ADA phone. Replace hall call stations with new fixtures. Replace the door operator with a new closed loop GAL MOVFR operator. Install new Infrared detector on the door if not already installed. The elevator shall be made fire code compliant, including all necessary wiring for and including circuitry for the operation of smoke detectors. The owner will have the fire detection devices installed by others. Jaffrey Grade School Replace existing controller with a new non-proprietary control system. The motor starter shall be solid state. The controls shall operate in selective collective operation, and shall include independent service, as well as fire service operation. Replace the car operating panel with a new panel that includes integral emergency lighting, and ADA phone. Replace hall call stations with new innovation stations. Replace the door operators with a new closed loop GAL MOVFR operator. This elevator is currently fire code compliant. -END OF RFP-
© Copyright 2024