SEAL “How To” SEAL Analytical - Mequon Technology Center 10520-C Baehr Road Mequon, WI 53092 262-241-7900 www.Seal-us.com Copyright © 2010 SEAL Analytical Reproduction or distribution of this document is expressly forbidden without written permission from SEAL Analytical 1 SEAL “How To” Change Lamp 3 Peristaltic Pumps 4 Change Syringe 5 Change Sample Probe and Flusher 6 SEAL Analytical - Mequon Technology Center 10520-C Baehr Road Mequon, WI 53092 262-241-7900 www.Seal-us.com Copyright © 2010 SEAL Analytical Reproduction or distribution of this document is expressly forbidden without written permission from SEAL Analytical 2 SEAL “How To” Change Lamp Disconnect • Turn Power Off • Remove Top Cover • Remove 3 mounting screws • Un-plug from Main Board Reconnect • Plug new into Main Board • Place lamp into position • Note the screw holes only line up one way • Insert and tighten screws AQ1 Lamp (11-0019) Lamp Plug Mounting Screws Adjust Measurement System • Select Measurement Setup • Wash The Cuvette 3 times • Start Readings • Click on each wavelength • Select the filter with the highest • Adjust to 8.9V with Gain • Select Dark Current • Adjust to 0.0030 with Offset Offset Gain Hover your Mouse Pointer over any Icon To see the function. SEAL Analytical - Mequon Technology Center 10520-C Baehr Road Mequon, WI 53092 262-241-7900 www.Seal-us.com Copyright © 2010 SEAL Analytical Reproduction or distribution of this document is expressly forbidden without written permission from SEAL Analytical 3 SEAL “How To” Peristaltic Pump Change Pump Tube • Loosen Knurled Nut • Slide Platen • Remove Pump Tubes • Disconnect from Nipple • Clean Pump Rollers • Clean Platen • Oil Rollers • Connect New Tube to Nipple Knurled Nut Pump Rollers Pump Platen Pump Tube Pump Roller Pin Point Oiler Oil Here Clean Platen Here Clean Rollers SEAL Analytical - Mequon Technology Center 10520-C Baehr Road Mequon, WI 53092 262-241-7900 www.Seal-us.com Copyright © 2010 SEAL Analytical Reproduction or distribution of this document is expressly forbidden without written permission from SEAL Analytical 4 SEAL “How To” Change Syringe 1. 2. 3. 4. Disconnect • Water in/out • 4 Mounting Screws • Syringe Clamp • Clamp Screw • Rotate Screw Down • Valve Wire Connector Mounting Screws Syringe Clamp Clamp Screw Screw Drive Replace • Syringe O-ring • Syringe Barrel • Syringe Piston Valve Wire Connector Top of Syringe Barrel Re-Connect • Valve Wire Connector • 4 Mounting Screws (loose) • Syringe Clamp • 4 Mounting Screws (tighten) • Water in/out Syringe Header Block Inlet Valve Syringe Glass Barrel Header Block Adjust Syringe Piston • Rotate Screw Up • Piston 1 -2 mm down • Tighten Clamp Screw Clamp Screw Needle Nose Pliers Syringe Screw Base SEAL Analytical - Mequon Technology Center 10520-C Baehr Road Mequon, WI 53092 262-241-7900 www.Seal-us.com Copyright © 2010 SEAL Analytical Reproduction or distribution of this document is expressly forbidden without written permission from SEAL Analytical 5 SEAL “How To” Change Sample Probe & Flusher 1. Disconnect Sample Probe • Unscrew thumbscrew • Disconnect tygon sample line 2. Replace old Sample Probe • Reconnect tygon sample line • Place sample probe in arm • and tighten thumbscrew 3. Disconnect Probe flusher • Using Allen wrench unscrew Probe Flusher • Carefully disconnect silicon tubing 4. Reconnect Probe Flusher • Attach silicon tubing to metal prongs • Install Probe Flusher on the bottom of Sample Arm 5. In Mechanical Setup of Maintenance check dilutor operation • See operator manual SEAL Analytical - Mequon Technology Center 10520-C Baehr Road Mequon, WI 53092 262-241-7900 www.Seal-us.com Copyright © 2010 SEAL Analytical Reproduction or distribution of this document is expressly forbidden without written permission from SEAL Analytical 6
© Copyright 2024