How to select parts to build an MHH series progressive divider valve assembly, with NPT threading, and MH inlet with bleed screws. MHH parts are now easier to order • No longer necessary to order the base components individually (NPT only) • Select the correct base assembly, then select valves and optional components • Base assembly is delivered assembled – Just install valves and other options, – Test, – Ship! How many sections are in the assembly? This includes working sections and bypass blocks Choose the appropriate MHH Base Plate Assembly. Count up the number of sections, and order a base assembly that has the correct number of sections. • • • • Part #, Description 24F596, MHH–3 Section 24F597, MHH–4 Section 24F598, MHH–5 Section • • • • Part #, Description 24F599, MHH–6 Section 24F600, MHH–7 Section 24F601, MHH–8 Section Completely assembled and tested with inlet, subplate (base plate), end section, tie rods, and nuts. Which valve sections do you need? MHH Working Sections • • • • • • 562679 MHH-6S* 562680 MHH-9S* 562681 MHH-12S* 562682 MHH-18S* 562683 MHH-24S* 562684 MHH-30S* *Each “S” section only uses one outlet, but each subplate has two outlets. For each “S” section in the assembly, order qty 1 of p/n 557349, 1/8” NPT pipe plug ,to plug the unused outlet. • • • • • • • 562685 MHH-6T 562686 MHH-9T 562687 MHH-12T 562688 MHH-18T 562689 MHH-24T 562690 MHH-30T 562660 MHH-BP (By-Pass Section) All MHH valve and BP sections must be ordered in multiples of 5 Optional components Crossports Cycle Indicators CR option: • 563469 Crossport Bar, Right Side CL option: • 563470 Crossport Bar, Left Side CB option: • 563471 Crossport Bar, Both Sides (Right and Left) For each CR or CL bar used, order qty 1 of p/n 557349, 1/8” NPT pipe plug, to plug the unused outlet. For the CB option, order 2 plugs. • For visual indication on a standard valve, order p/n 563251, Visual Cycle Indicator Assembly • For proximity switches, see next page Proximity switches See literature L15600 for more information. Explosion-proof prox switches include 6ft, 3 conductor cable. All others ship without connecting cable, order cable separately (see next page). Part No. Prox. Switch Type Operating Voltage Cable Electric Connection LED 24K415 DC PNP 10-36 VDC M12 Yes 600? 5100 557741 FSM 115 VAC 3-pin BH Mini No 200 3,500 150,000,000+ 557745 FSM 115 VAC Explosion Proof No 200 3,500 150,000,000+ 557746 FSM 115 VAC 5-pin BH Mini No 200 3,500 150,000,000+ 557747 FSM 10-32 VDC 4-pin CH Mini No 200 3,500 150,000,000+ 563477 FSmech 20-32 VDC 5-pin BH Mini Yes 150 7,500 10,000,000+ 563478 FSmech 20-32 VDC 3-pin BH Mini Yes 150 7,500 10,000,000+ 563484 FSmech 5-pin BH Mini No 150 7,500 10,000,000+ 563485 FSmech No 150 7,500 10,000,000+ 563427 Reed No 60 7,500 10,000,000+ 563501 FSmech Yes 150 7,500 10,000,000+ 115 VAC or 10-32 VDC 115 VAC or 10-32 VDC 115 VAC or 10-32 VDC 20-32 VDC Explosion Proof 1/2 in NPT cond 4-pin Micro Max Cycle Max Pressure Rate Per Min Rating - psi Rated Life Cycle Cables for Prox switches • Most prox switches ship without a cable, so order the correct cable for the connector on the prox switch: • 124333, M12 Cable, Male by Female, 5 m/16 ft (for G3 pump) • 558021, 3-Pin Cable, Straight Connector - 6 ft • 558022, 3-Pin Cable, Straight Connector - 12 ft • 558025, 4-Pin Cable, Straight Connector, Polarity - PNP - 12 ft • 558026, 4-Pin Cable, 90° Connector, Polarity - PNP - 12 ft • 558023, 5-Pin Cable, Straight Connector - 6 ft • 558024, 5-Pin Cable, Straight Connector - 12 ft Performance (High Pressure) Indicators Reset Indicator with Memory Automatic Relief Indicator Shows you which line is blocked during a lube fault. Vents to atmosphere when a line is blocked, allowing other lines to keep working. • • • • • • • • • • • • • • • • • 563252 563253 563254 563255 563256 563257 563258 563261 563263 563262 250 psi 500 psi 750 psi 1000 psi 1500 psi 2000 psi 2500 psi 3000 psi 3500 psi 5000 psi 563170 563171 563172 563173 563174 563175 563176 750 psi 1000 psi 1250 psi 1500 psi 2000 psi 2500 psi 3000 psi Check Valves Outlet Check Valves: Bearing Point Check Valves: • • • 1/8 NPT male inlet x 1/8 NPSM female outlet See L15825 for more information Single Ball Check Valves (steel body, steel ball): • 5000 psi max pressure • 563195 10 psi cracking pressure, • 563196 35 psi cracking pressure, • 563197 120 psi cracking pressure, • 563198 250 psi cracking pressure • 563051 360 psi cracking pressure Soft Seat Check Valve (SST body, Viton ball): • 7500 psi max pressure • 563425 35-60 psi cracking pressure • Required for oil systems to keep oil in lines and controlled Optional for grease systems Many options available, see L15825 for product offerings that match the needs of the application. Appendix A: MHH Valve Suffixes Code MH-xxA MH-xxB MH-xxC MH-xxD Description Not used Twin valve with cycle pin on Right side. Single valve with cycle pin on Right side, outlet on Right side. Single valve with cycle pin on Right side, outlet on Left side. MH-xxE Twin valve with prox switch. MH-xxF Single valve with prox switch, outlet on Right side. MH-xxG MH-xxH MH-xxI MH-xxJ MH-xxK Single valve with prox switch, outlet on Left side. Twin valve with cycle pin on Left side. Not used Single valve with cycle pin on Left side, outlet on Right side. Single valve with cycle pin on Left side, outlet on Left side. MH-xxL Standard Single valve, but with outlet on Left side. MH-xxM Twin valve with prox switch, but prox is on the Left side. MH-xxN MH-xxO Single valve with prox switch on Left, outlet on Right side. Not used MH-xxP MH-xxQ MH-xxR MH-xxS MH-xxT MH-xxU MH-xxV MH-xxW MH-xxX MH-xxY MH-xxZ MH-BP Single valve with prox switch on Left, outlet on Left side. Not used Not used Standard single valve, with outlet on Right side. Standard twin valve. Not used Not used Not used Not used Not used Not used Not used Additional comments Use standard "T" valve, plus prox switch specified by customer. Lubriquip used 527-006-060 (563485). Use standard "S" valve, plus prox switch specified by customer, plug left outlet on subplate. Lubriquip used 527-006-060 (563485). Use standard "S" valve, plus prox switch specified by customer, but plug right outlet on subplate. Lubriquip used 527-006-060 (563485). Use standard "S" valve, but plug Right outlet on subplate, leave Left outlet open. Use standard "T" valve, plus prox switch specified by customer. Lubriquip used 527-006-060 (563485). Use standard "S" valve, plus prox switch specified by customer, plug left outlet on subplate. Lubriquip used 527-006-060 (563485). Use standard "S" valve, plus prox switch specified by customer, but plug right outlet on subplate. Lubriquip used 527-006-060 (563485). Use standard "S" valve, plug left outlet on subplate, leave right outlet open. Appendix B: Technical Specifications Torque Specifications Tie Rod Nut: • 5-8 ft lbs (6.8 – 10.8 N-m) Valve Block Mtg. Screw: • 8-9 ft lbs (10.8 – 12.2 N-m)* Indicator Port Plug: • 8-9 ft lbs (10.8 – 12.2 N-m)* Inlet Bleed Screw: • 1-2 ft lbs (1.4 – 2.7 N-m) Piston Enclosure Plug: • 12-15 ft lbs (16.3 – 20.3 N-m)* *O-Ring sealed components Net Weight lbs (kg) • 3 section: 5.9 (2.7) • 4 section: 7.3 (3.3) • 5 section: 8.7 (4.0) • 6 section: 10.2 (4.6) • 7 section: 11.6 (5.6) • 8 section: 13.0 (5.9) For more specs see L10103 For other options and specialty parts, see the ILE Buyers Guide, or contact Graco. This guide is intended to keep the subject matter as simple as possible, but Graco does offer other thread options, and more optional components.
© Copyright 2024