RS232 CONTROL How to Connect to Audia/Nexia Using HyperTerminal

How to Connect to Audia/Nexia Using HyperTerminal
RS232 CONTROL
One of the many ways that Audia and Nexia can be controlled is via RS232 commands. This type of control is one
of the preferred methods when using third party controllers. Sometimes it is required to test these commands
before implementing them or gain access to a unit in order to view/change IP settings or rescue a faulty unit. In
any of these cases, a unit can be accessed by using HyperTerminal. This note explains how to establish a
connection via HyperTerminal. For further information on changing IP settings or rescuing a faulty unit, please refer
to the proper notes.
PROCEDURE
1.
2.
3.
Connect your computer serial port (Com port) to the RS232 port on the unit using a 9 pin straight-through
cable. (NOT a null-modem cable)
In Windows XP or 2000, open a HyperTerminal session by going to Start Æ Programs Æ Accessories Æ
Communications Æ HyperTerminal. Please note that Windows Vista does not have the HyperTerminal
application installed by default. The application can be downloaded from the web.
In the connection description dialog, enter a name for your connection and click OK.
Figure 1 – Connection Description Dialog
4.
In the Connect To dialog, under the pull-down menu labeled Connect Using, select the location of your Serial
Com Port and click OK.
Figure 2 – Connect to dialog
BIAMP SYSTEMS TECHNICAL SUPPORT GROUP
www.biamp.com
•
Page 1 of 3
5.
In the COMx Properties dialog, set the Com port properties to 38400 / 8 / None / 1 / None as shown in
figure 3 and click OK.
Figure 3 – COMx Properties Dialog
6.
To display what’s being typed, go to File Æ Properties, and select the Settings Tab. Click on ASCII Setup
and enable "echo typed characters locally". For easier reading, you can also enable “Send line ends with line
feeds” and click OK.
Figure 4 – ASCII Setup Dialog
7.
To test the connection, hit the Enter key a couple of times to ensure that communication has been
established. The unit should respond with a –ERR message as seen in figure 5. If “Send line ends with line
feeds” was also enabled, there will be a second message from the unit every time we hit the Enter key.
Please disregard these. A second option would be to power cycle the unit (unplug the AC and plug it back
in), after the unit reboots, it should respond with a welcome message as seen in figure 6.
BIAMP SYSTEMS TECHNICAL SUPPORT GROUP
www.biamp.com
•
Page 2 of 3
Figure 5 – Error messages
Figure 6 – Welcome message
If this application note did not answer your questions on the topic of “How to Connect to Audia/Nexia Using
HyperTerminal”, please contact Biamp Technical Support Group by phone at + 1 800 426 1457 or by email at
[email protected].
BIAMP SYSTEMS TECHNICAL SUPPORT GROUP