Digital control AC method (Hybrid Digital Control AC) What is HDC-AC ? Features of HDC-AC The unique AC-type high-voltage power supply (patent pending) developed by our company is compact and maintains a stable electrical supply. The HDC-AC mounted ionizer is equipped with superior features such as the ability to maintain long-term stability in static elimination. A power supply with superior features has become a reality by using digital control for the input of the wire-wound transformer Long-term stability in static elimination capabilities Past transformers HDC-AC transformers 2)By using digital control (PWM*) for the transformer, we have achieved easy control of highvoltage power output. 200Hz IB voltage (V) / ± Decay time (sec) 1)Ultra compact and high-voltage generating wirewound transformer has been made as small as possible (about 1/10th the size of existing models). Running data (HDC-AC mounted ionizer) ⅠB 30 25 20 15 10 5 0 −5 −10 −15 −20 −25 −30 0 500 1000 1500 2000 2500 6140 7196 +DEC 8660 12140 −DEC 13964 16580 Time (h) Decrease in emitter needle abrasions High voltage power stoppages contribute to fewer emitter needle abrasions leading to less dirt and long-term stability. Ultra low ozone (same as background level) Control by varying the pulse input Control by moving one of the poles *Pulse Width Modulation By controlling the primary side signal of the transformer using PWM (pulse width modulation), we have achieved high quality output. Unique ion balance adjustment functions Amplitude modulation: Controls the amount of ions generated Position modulation: Emitter needle absorbs excess ions 5 Bar type Ionizer HDC-AC with built-in high-voltage power supply Bar type ionizer ELIMINOSTAT CABX HDC-AC technology provides long-term stability in static elimination without the need for cleaning over the long term. 30% improvement in static elimination times and products sizes over existing models! TIMER RESET TIME SELECT Indicator Panel CLEANING ALARM POWER RUN Display explanation CLEANING TIMER RESET T・SELECT Dimensional Diagrams ●Cleaning timer function that indicates the cleaning time An LED will light up when the timer had been set in advance and will indicate the cleaning time. The client can set the time when the light will appear. (9 patterns, 100-1000 hours and option not to set the light.) ●Emitter needle variations (scheduled to be released soon) We provide needles that collect less dust, glass emitter needles and silicon emitter needles to respond to static elimination in environments in which little dirt is permitted. 22 8 Mounting bracket Electrode base (ABS) 74 84 67 59.8 10 Air joint 350~1600mm: φ6 1850~3100mm: φ8 8 7 1 L (350-3100) Pitch 250 Emitter needle nozzle Emitter pole (stainless steel) Pitch 50 L−20 L+32 Model Ion generation method Input power supply Electric consumption Output voltage Output voltage under abnormal circumstances Unit dimensions Air supply range Ion balance Operating environment ●Maintaining safety Safety is maintained during use through the detection of minute electrical discharges and the low-voltage wiring input of the DC24V. 0 65 ●Simplified low-flow type emitter needle nozzle for air consumption Two types of emitter needle nozzles are available: the usual nozzle for air consumption and a low-flow type nozzle for compressed air consumption. Nozzles can be easily replaced. 6 10 9 INPUT :24V DC 150mA AIR PRESSURE:0.01-0.5MPa(Clean and Dry Air Only) 5 32 Indication Panel 3 ●30% improvement in static elimination times and product sizes (compared to Shishido Electrostatic’s existing products) The CABX is the next generation of Shishido Electrostatic’s existing CABC model. A 30% improvement over the existing product has been achieved with increased static elimination times and downsizing of the product. This is the industry’s leading static elimination ionizer. Mounting bracket (angle adjustable) Intermediate bracket (over 1100mm) Power supply and signal connector 2 HDC-AC technology provides stable and long-term static elimination capabilities. We have designed an ionizer that does not require cleaning over the long term. 1) 30% increase in capabilities 2) Long-term stability of static elimination capabilities 3) Decrease in emitter needle abrasions 4) Ultra low ozone 5) Superior ion balance 6) Minimum flow type nozzle 7) Cleaning timer 8) Emitter needle variations 9) Safety features : The LED is lit while the power is turned on. : The LED is lit under normal operations. : The LED lights up when a minute electrical discharge occurs in the emitter needle of the high-voltage main body or when an in-circuit current surge occurs. : When the approximate operating time exceeds that set using T-SELECT, a yellow LED lights up. It will stay lit until the RESET button is pressed. : To turn off the CLEANING LED. : To select the approximate operating time before the CLEANING LED lights up. 4 Main Features POWER RUN ALARM Accompanying items ELIMINATOR CABX Corona discharge method(HDC-AC) DC24 V ±5 % 3.6 VA 10 kV0-p(0 to peak) No voltage contact output (by normal close MOSFET relay) 350 to 3100×92×29 mm(W×H×D) Less than 0.5 Mpa Within ±30 V (distance 300 mm, air pressure 0.3 Mpa at time of supply) Surrounding temperature: 10 to 40 ℃, surrounding humidity: 5% to 85%(no condensation) Air supply: clean dry air Operation manual, mounting bracket, power supply and signal connector cable(3 m) , intermediate bracket(over 1100 mm) [ HDC-AC with built-in high-voltage power supply ] Bar type Ionizer Power Supplies Models according to electrode dimensions ★Please state the length of the electric pole and type of emitter needle required, along with the product model when placing your order with Shishido Electrostatic. CABX350 Lengths 450g 600mm 650g 850mm 1100mm 860g 1060g 1350mm 1260g CABX□□□□ -□□ CABX600 Length and nozzle type ●Lengths are 350-3100mm (250mm pitch) ●Nozzle flow H or L ●Emitter needle material W, S or G CABX850 Examples Length 1850mm, high flow tungsten emitter needle: CABX1850-HW Length 600mm, low-flow silicon emitter needle: CABX600-LS CABX1100 CABX1350 CABX1600 Weights 350mm 1600mm 1470g 1850mm 1670g 2100mm 1880g 2350mm 2080g 2600mm 2290g 2850mm 2500g 3100mm 2710g CABX1850 CABX2100 CABX2350 CABX2600 CABX2850 CABX3100 Static Elimination Features CABX850mm, air pressure: 0.5 Mpa 3.0 CABX850 high flow nozzle 2.5 CABX850 low-flow nozzle 2.0 CABC (our company’s existing products) Static elimination time (sec) Static elimination time (sec) CABX850mm, air pressure: 0.3 Mpa 1.5 1.0 0.5 0.0 100 300 Measurement distance (mm) CABX high flow nozzle CABX low-flow nozzle CABC (our company’s existing products) 500 100 0.2 0.2 0.3 500 0.6 0.8 1.1 700 1.0 1.5 1.8 1000 1.7 2.4 2.7 1.5 1.0 0.5 30 +DEC −DEC 25 20 15 10 5 0 0 95 240 360 480 Time (sec) 600 720 780 6756 100 300 Measurement distance (mm) CABX high flow nozzle CABX low-flow nozzle IB voltage (V) / ± Decay time (sec) IB voltage (V) / ± Decay time (sec) ⅠB CABX850 low-flow nozzle 2.0 Running Data CABX CABX850 high flow nozzle 2.5 0.0 700 1000 Measurement distance (mm) 300 0.3 0.4 0.7 3.0 30 25 20 15 10 5 0 −5 −10 −15 −20 −25 −30 500 300 0.3 0.3 100 0.2 0.2 700 500 0.5 0.6 700 0.7 1.1 (CABC) ⅠB (Existing product: HDC-AC mounted product) 0 500 1000 1500 2000 2500 1000 1200 Measurement distance (mm) 6140 7196 8660 1000 1.3 1.8 +DEC 12140 1200 1.9 2.2 −DEC 13964 16580 Time (sec) 9 Bar type Ionizer HDC-AC with built-in high-voltage power supply Bar type ionizer ELIMINOSTAT CABX Safety features detect abnormal discharges and sparks Stable elimination of static over the entire area Since large amounts of positive and negative ions are constantly supplied to the area requiring static elimination, there is very little difference in static elimination between one area to the next. The ELIMINOSTAT CABX is therefore ideal for electronic devices where delicate static elimination is required. Image This safety feature automatically detects abnormal high-voltage discharge and shuts down the input such as when there is a short circuit in the ionizer s emitter needle. Image Realization of a reduction in the amount of air consumption (*When using the low-flow type L nozzle) The shape of our proprietary nozzle has enabled a considerable reduction in the amount of air consumption (60% when compared with other Shishido Electrostatic products). This supports powerful and stable static elimination. The nozzle can be detached and replaced. Exchange of the emitter needle (Image) Image Choose from two types of nozzles depending on the purpose ●For rapid static elimination: High-flow type H nozzle (4 holes) 0.05Mpa 0.1Mpa 0.2Mpa 0.3Mpa 0.4Mpa 0.5Mpa 350 22 32 48 61 78 95 600 41 59 89 117 149 177 850 53 81 122 165 208 255 1100 62 95 151 200 259 323 1350 68 105 168 230 293 362 1600 92 112 180 248 321 393 1850 130 194 294 381 499 622 2100 145 223 328 426 559 687 2350 149 229 343 466 614 748 2600 154 244 362 496 654 806 ●For low air consumption: Low-flow type L nozzle (2 holes) 0.05Mpa 0.1Mpa 0.2Mpa 0.3Mpa 0.4Mpa 0.5Mpa 350 11 16 26 34 42 51 600 22 32 48 63 82 91 850 33 48 70 95 120 143 1100 44 52 91 123 157 187 1350 50 60 106 149 188 233 1600 55 81 129 173 222 274 1850 80 112 177 240 306 374 2100 91 130 201 276 363 425 2350 100 146 227 303 388 471 unit: l/min(ANR) 2850 159 250 374 516 678 848 3100 163 259 383 531 698 882 unit: l/min(ANR) 2600 108 158 246 333 423 515 2850 115 171 270 363 461 556 3100 126 184 289 397 492 598 Optional parts to support easy static elimination We provide needles that collect less dust, glass emitter needles and silicon emitter needles (scheduled to be released soon) to respond to static elimination in environments in which little dirt is permitted. ●CABX custom AC adapter ●Intermediate bracket ●Power supply and signal extension cable ●Low-flow type L nozzle Tungsten emitter needle type Silicon emitter needle type Glass emitter needle type ●High-flow type H nozzle Tungsten emitter needle type Silicon emitter needle type Glass emitter needle type 10 : OCABX-DA (input voltage AC100V-240 V) : OCABX-SUSP-A (over 1100 mm comes as standard equipment) Optional parts : OCABX-ENC3M (length : 3 m) : OCABX-NDL-LW01 : OCABX-NDL-LS01 : OCABX-NDL-LG01 : OCABX-NDL-HW01 : OCABX-NDL-HS01 : OCABX-NDL-HG01 Custom AC adapter Intermediate bracket Power supply and signal extension cable HDC-AC with built-in high-voltage power supply Bar type ionizer ELIMINOSTAT CAB Air Bar Ionizer with a static elimination control function High-level type that has realized a static elimination device control system Centralized management system Air Bar Ionizer with a static elimination control function … ELIMINOSTAT CAB The ELIMINOSTAT CAB ionizer, featuring a built-in high-voltage power supply, is available in eight different lengths from 600 to 2350 mm to suit a diverse range of environments. ELIMINOSTAT CAB POWER RUN COMM ALARM I.B. P.D. POWER RUN COMM ALARM I.B. P.D. + Power box … PB24-01 Two D-sub connectors are provided to enable two static-eliminating electrodes to be connected. − Unit ID 012 3 12345678 O.C. ION CONDITION POWER/SIGNAL ELIMINOSTAT CAB + [ HDC-AC with built-in high-voltage power supply ] Bar type Ionizer Power Supplies Bar type Ionizer − Unit ID 012 3 12345678 O.C. ION CONDITION POWER/SIGNAL Connecting cable elimination 1.Normal electrical discharge observation function 2.Ion balance monitoring function 3.Detection of abnormalities such as short-circuit discharges (sparks), over-current, or imbalance L1 8.2 5.2 72 650 Power supply and signal connector 30 ●Wide range of functions to ensure reliable static 75 10 Intermediate mounting bracket (120) supply by the miniaturization of the winding transformer It comes true with a digital technology. (Patent pending) (35) 17 5.2 Dimensional Diagrams Main Features ●A storehouse type ionizer in the high-voltage power One touch Air joint ELIMINOSTAT CAB POWER RUN COMM ALARM I.B. P.D. + − Unit ID O.C. ION CONDITION POWER/SIGNAL 75 50 a×50(=L2) L Emitter needle ●Utilization of nozzles that enable a considerable reduction in the amount of air consumption (60% when compared with other Shishido Electrostatic products); the nozzles are replaceable ●Alarm displays and output signals enable a speedy response when abnormalities occur in the main unit. ●Reduction in the amount of ozone generated Static Elimination Features HV power supply used Ion generation method Main unit dimensions Weight Ion balance Within Static charge discharge time 1000 Charged voltage (V) Model Input power supply Ozone density Material of Emitter Supply air range *3 Air tube Operating Environment Main functions 300mm 400mm 500mm 600mm 750 500 250 0 0 1 2 3 4 5 6 7 Static decay time (sec) Note: This data is for reference purposes only. The values are not guaranteed values. The reference values are those for when the length of the CAB electrode is 600 mm(and when the induced air pressure is 0.20 MPa) The static decay time is the time taken to decay to(±)100 V when the voltage applied to the charged plate is(±)1 kV. The ion balance voltage is the offset voltage(V)when the charge plate is in steady state.(US standard EOS/ESD-STM 3.1-2000)Please refer to the values at the right for the static decay time. These values represent the distance from the front surface of the device, and are(±)mean decay values. Power box Model Input power supply Output voltage Number of units that can be connected Output signal setting Power supply signal line Model Connector CAB 24 VDC ±5% PB-01 power box required when the main unit is used Alternating current power supply (built into the main unit) AC corona discharge 36×150×600 to 2350 mm(W×H×D) 2.3 kg (in the case of the CAB 1600 mm model) 30 V (measurement distance: 300 mm, air pressure: 0.3 MPa at time of shipment from the factory) 0.8 ( s measurement distance: 300 mm, air pressure: 0.3 MPa at time of shipment from the factory) 0.002 ppm or less (reference value) Tungsten 0.01 to 0.3 MPa(usable range) 6-mm diameter(air supplied at two locations, at both ends) 10 to 40℃ / 15 to 85% RH(no condensation) Ion condition alarm output, ion balance alarm output, pulse discharge alarm output, over-current alarm output, auto ion balance adjustment, normal operating display, communication status display(when Controller CR-01 is connected[will be available shortly] ) , setting of IDs for individual recognition(when Controller CR-01 is connected[will be available shortly] ) PB24-01 100 to 240 VAC(50/60 Hz) 24 VDC 2 "A contact, B contact, switching exclusion method used" CAB-CA05(5 m) , CAB-CA10(10 m) D-sub 11
© Copyright 2024