6"X6" PRESSURE TREATED WOOD POSTS 2"x8" CEDAR RAILS 4" SPACING 12'-0" SPACING FENCE ENCLOSURE - TOP VIEW BOLLARD NOTE: NUMBER OF BOARDS WILL VARY DEPENDING ON SPACE BETWEEN BOARDS AND ACTUAL WIDTH OF BOARDS. CONCRETE FILL 6"Ø X 1/8" PAINTED STEEL BOLLARD FILLED SOLID WITH CONCRETE SLOPE TO GRADE MIN 1/4" PER FOOT PREMOULDED JOINT FILLER GRADE LEVEL 24"Ø POURED CONCRETE PIER FOOTING 8 2'-6" 1'-0" PAVING (SEE PLAN) 1/2" PREMOULDED JOINT FILLER AT PAVING TOOLED EDGES CONCRETE APRON W/ REINF #4 DOWEL @ 18" OC 1.4 X 1.4 X 6 X 6 WWF 2'-0" GRAVEL BASE CONCRETE APRON DETAIL Scale: 1" = 1'-0" 3/8" WD x1 1/4" DEEP SAWCUT CONTROL JOINT CONCRETE APRON W/ W2.9xW2.9 6"x6" WWF COMPACTED GRAVEL BASE COURSE REF STRUCTURAL TYPICAL CJ DETAIL Scale: 1" = 1'-0" GATE POST COLLAR WELDED ALL AROUND POST HINGE COLLAR W/ GREASE FITTING 1/2" THICK STL PLATE -SLOTTED 4" GATE POST 1/2" THICK STL PLATE -SLOTTED STL BOLTS & WASHERS STL BOLTS HINGE COLLAR W/ GREASE FITTING COLLAR WELDED ALL AROUND POST Scale: 1" = 1'-0" GATE HINGE DETAIL 4" STL BOLTS & WASHERS ELEVATION 9 SECTION 6" 1"x6" CEDAR FACE BOARDS Scale: 1/2" = 1'-0" FENCE ENCLOSURE - REAR VIEW BOLLARD DETAIL 1'-6" 6"X6" PRESSURE TREATED WOOD POSTS 2"x8" CEDAR RAILS 5 Scale: 1/8" = 1'-0" 2" 7 Scale: 1/2" = 1'-0" 8'-0"± GATE 1.9" O.D. GALV FRAME W/ 4" x 8' HIGH CEDAR SLATS ATTACHED W/ SELF TAPPING SCREWS. PROVIDE HINGES AND LATCH W/ EYE FOR PADLOCK. GATE LOCK W/ FLAT MOUNT & ADA STYLE LEVER SWING GATE WHEEL AT EACH GATE 3 3" 6" 3" 1"x6" CEDAR FACE BOARDS (2) 801 X 1 12" GALV. NAILS (TYP.) 1'-10" GATE POST (TYP) Scale: 1/4" = 1'-0" 4'-0" 3'-6" 6 12'-0" SPACING Scale: 1/2" = 1'-0" 6'-0" 18'-0" • 1'-0" 4" 6"X6" PRESSURE TREATED WOOD POSTS 2'-4" 18'-0" FENCE ENCLOSURE - FRONT VIEW 6'-0" DUMPSTER CONC APRON COORDINATE WITH CIVIL LINE OF PIER BELOW PIVOTING CANE BOLT FABRICATED FROM 1/2" DIA STL ROD 8'-0" 2'-6" GATE ELEVATION PROVIDE 3/4" DIA 4" DEEP SLEEVES IN CONC PAVEMENT FOR CANE BOLTS 2 48" MAX 2"x8" CEDAR RAILS 4 1'-10" DUMPSTER PROVIDE STEEL RECIEVER SLEEVE SET IN CONC @ CANE BOLT 8 A0-01 17'-6" @ GATE DUMPSTER ENCLOSURE PLAN NOTE: REF CIVIL PLANS FOR LOCATION 2 A0-01 2" Scale: 1/4" = 1'-0" 3" 1"x6" CEDAR FACE BOARDS TYP (2) 801 X 1 12" GALV. NAILS (TYP.) 6" THK SEALED CONC PAD - SEE SITE DWGS FOR GRADE ELEVS 1"x6" CEDAR FACE BOARDS 4 A0-01 6" DIA BOLLARD SEE DETAIL 7/A0-01 2 EA EQUAL GATES 1.9" OD GALV FRAME W/ 4"x8'H CEDAR SLATS ATTACHED W/ SELF TAPPING SCREWS. PROVIDE SWING GATE WHEEL HINGES, CENTRAL GATE STOPS & LATCH W/ EYE FOR PADLOCK 1 12'-6" 5'-6" 8'-0" 36" Florida Business License: AA26001620 CONSULTANT: SEAL: DONALD FRANCIS BARRY, AR94443 PERMIT 0 REV Dept Mgr Approval B.COLBURN THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION PURPOSES UNTIL THE SEAL AND SIGNATURE OF THE RESPONSIBLE REGISTRANT APPEARS ON THE DRAWING, AND PROPER PERMIT FORMS AND RELATED FEES ARE TRANSMITTED BY THE OWNER, OWNER'S AGENT OR CONTRACTOR TO THE AUTHORITY HAVING JURISDICTION. 9/28/2012 A.RICCUTTI B.COLBURN 9/20/2012 PALMETTO CAPITAL GROUP 220 East High Street Charlottesville, VA 22903 Office: (434) 295-7131 Contact: Austin Cox DOLLAR GENERAL US HWY 27 & SANDMINE ROAD DAVENPORT, FLORIDA DO NOT SCALE DRAWING JCDT.12.0279 T/O PARAPET = 18'-4" AFF FINISH FLOOR = 0'-0" A 3 19'-8" 9a B 6 1 9a Scale: 1/8" = 1'-0" 3 9 2 C 2 5 9 8 11 10 9b 9a 9 8 7 2 REAR BUILDING PARAPET WALL EIFS SYSTEM @ FRONT ENTRANCE STANDARD METAL ROOF PANELS EIFS SYSTEM EIFS SYSTEM SMOOTH FACE CMU PIERS GUTTERS & DOWN SPOUTS METAL AWNING SPLIT FACE CMU VENEER MATERIAL TO MATCH SHERWIN WILLIAMS PEMB MANUFACTURER REF PRODUCT APPROVAL ON COVER SHEET PEMB MANUFACTURER REF PRODUCT APPROVAL ON COVER SHEET REF PRODUCT APPROVAL ON COVER SHEET JOHNSON CONCRETE COMPANY PEMB MANUFACTURER PEMB MANUFACTURER JOHNSON CONCRETE COMPANY MANUFACTURER SW #6149 "RELAXED KHAKI" SW #7055 "ENDURING BRONZE" TO MATCH SHERWIN WILLIAMS SW #6149 "RELAXED KHAKI" GALVALUME TO MATCH SHERWIN WILLIAMS SW #7034 "STATUS BRONZE" TO MATCH SHERWIN WILLIAMS SW #6149 "RELAXED KHAKI" COLOR JC-521 "ROCK RIDGE" TO MATCH SHERWIN WILLIAMS SW #6149 "RELAXED KHAKI" TO MATCH SHERWIN WILLIAMS SW #7034 "STATUS BRONZE" COLOR JC-521 "ROCK RIDGE" COLOR / STYLE STANDING SEAM LIT 1.0- FINE OR APPROVED EQUAL LIT 1.0- FINE OR APPROVED EQUAL OR APPROVED EQUAL GENERAL REMARKS 12 PREFINISHED METAL COPING @ HVAC ENCLOSURE 5 Scale: 1/8" = 1'-0" B SW #7034 "STATUS BRONZE" 21 11 3 9a 2 1 9 18 11 21 15 9 11 21 15 9a REF PRODUCT APPROVAL ON COVER SHEET 3 9a 9 2 9 9a NORTH ELEVATION 6 2 9a HOLLOW METAL DOOR / FRAME D 2 13 22 4'-0" 9b 23 9 8 9a 9 TO MATCH SHERWIN WILLIAMS SW #6149 "RELAXED KHAKI" 1 7 9 4 3'-6" 1 A5 12 10 9a 9 6 REF PRODUCT APPROVAL ON COVER SHEET 21 11 9b 1 7 9 1 A3 3 3 EIFS ACCENT BAND 3 11 21 EXTERIOR BUILDING CANOPY NOTE: ALL EXTERIOR SIGNAGE SHALL BE SUBMITTED UNDER SEPARATE PERMIT EQ 24 8 9 1 23 D 9 Scale: 1/8" = 1'-0" 1 A3 9a 16 16 DARK BRONZE 21 11 3 9a 6 4 16 EAST ELEVATION 8 9 WEST ELEVATION Scale: 1/8" = 1'-0" 16'-0" REF PRODUCT APPROVAL ON COVER SHEET 2 3 16 2'-8" 3 17 22 14 A 9 16 8 18 11 21 REF PRODUCT APPROVAL ON COVER SHEET ALUMINUM FRAME LIT 1.0- FINE OR APPROVED EQUAL OR APPROVED EQUAL 16 C SW #7055 "ENDURING BRONZE" 9b TO MATCH SHERWIN WILLIAMS 7'-4" PREFINISHED METAL COPING @ PARAPET 10'-0" 9'-8" STOREFRONT SYSTEM 20'-4" 24 9a 20'-4" 21 TAG EXTERIOR FINISHES 4 A3 9a 4 4'-4" 14'-0" 8" 19'-8" 21 11 9 9a SOUTH ELEVATION 4 9 21 21 11 9 9a 9 10'-8" 9'-8" PEMB MANUFACTURER SHALL PROVIDE ALL METAL FRAMING, REAR PANELS, CRICKETS, AND REQUIRED FLASHING FOR ANY AND ALL PARTS OF THE RAISED PARAPET AND MASONRY PILASTERS ABOVE THE ROOF LINE - TYP 1 PEMB MANUFACTURER SHALL PROVIDE ALL METAL FRAMING, REAR PANELS, CRICKETS, AND REQUIRED FLASHING FOR ANY AND ALL PARTS OF THE RAISED PARAPET AND MASONRY PILASTERS ABOVE THE ROOF LINE - TYP FINISH FLOOR = 0'-0" 1'-8" 1'-0" 8 9 16 22 T/O PARAPET = 20'-4" AFF T/O PARAPET = 19'-8" AFF 16'-0" FINISH FLOOR = 0'-0" 14'-4" 4'-0" 1'-4" 18'-4" 18'-4" 14'-0" 18'-4" KEYED NOTES 10 9b 9a 9 8 7 6 5 4 3 2 EIFS CORNICE (REF EXTERIOR FINISH SCHEDULE THIS SHEET) PRE-FINISHED METAL ROOF (REF EXTERIOR FINISH SCHEDULE THIS SHEET) EIFS SYSTEM ON EXTERIOR SHEATHING ON METAL STUD FRAMING (REF EXTERIOR FINISH SCHEDULE THIS SHEET) EIFS SYSTEM ON METAL WALL PANELS (REF EXTERIOR FINISH SCHEDULE THIS SHEET) SMOOTH FACE CMU PIERS (REF EXTERIOR FINISH SCHEDULE THIS SHEET) GUTTER AND DOWNSPOUT (REF EXTERIOR FINISH SCHEDULE THIS SHEET) METAL CANOPY (REF EXTERIOR FINISH SCHEDULE THIS SHEET) EXTERIOR RECEPTACLE. (REF ELECTRICAL DRAWING E1) EXTERIOR WALL MOUNTED PARKING LOT FIXTURE - INSTALL T/O FIXTURE AT 12'-0" AFF (REF TO ELECTRICAL DRAWING E2) EXTERIOR BUILDING WALL FIXTURE INSTALL T/O FIXTURE AT 12'-0" AFF (REF TO ELECTRICAL DRAWING E2) EXTERIOR BUILDING WALL FIXTURE INSTALL T/O FIXTURE AT 16'-0" AFF (REF TO ELECTRICAL DRAWING E2) SPLIT FACE CMU VENEER (REF EXTERIOR FINISH SCHEDULE FOR COLOR) 1 11 PRE-FINISHED METAL PARAPET PANEL (BY PEMB) (REF EXTERIOR FINISH SCHEDULE THIS SHEET) GC SHALL COORDINATE THE EXTERIOR CANOPY SIGN WITH DOLLAR GENERAL CORP. GC TO PROVIDE ADEQUATE BLOCKING AS REQUIRED BY SIGN MANUFACTURER TO SUPPORT SIGN WEIGHT (MAX 1,400 LBS) AND SHALL BE SUPPORTED BY CANOPY FACE. GC TO PROVIDE CIRCUIT AS NOTED ON ELECTRICAL PLAN. SIGN TO BE PROVIDED AND INSTALLED BY DOLLAR GENERAL CORP. INSTALL BUILDING SIGN CENTERED ON FRONT ELEVATION. 12 DOOR BUZZER. REFER TO ELECTRICAL DRAWING E1 FOR ADDITIONAL INFORMATION. 13 14 WALL HYDRANT. REFER TO PLUMBING DRAWING P1 FOR ADDITIONAL INFORMATION. VENT FOR BATHROOM EXHAUST. REFER TO MECHANICAL DRAWING M1 FOR ADDITIONAL INFORMATION. 15 OUTSIDE AIR TEMP. SENSOR MOUNTED OVER RECEIVING DOORS @ 8'-0" A.F.F. GROUND MOUNTED HVAC UNITS ON RASIED 6" CONC PAD, (REF EXTERIOR FINISH SCHEDULE THIS SHEET) (REF SHEET S1 AND M1) 17 EAVE STRUT HEIGHT AT 14'-0" A.F.F. 16 18 NOT USED NOT USED 19 20 22 EIFS ACCENT BAND (REF EXTERIOR FINISH SCHEDULE THIS SHEET) SERIVCE DOOR (REF EXTERIOR FINISH SCHEDULE THIS SHEET) 21 23 STOREFRONT SYSTEM (REF EXTERIOR FINISH SCHEDULE THIS SHEET) PRE-FINISHED METAL COPING (REF EXTERIOR FINISH SCHEDULE THIS SHEET) 24 Florida Business License: AA26001620 CONSULTANT: SEAL: DONALD FRANCIS BARRY, AR94443 PERMIT 0 REV Dept Mgr Approval B.COLBURN THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION PURPOSES UNTIL THE SEAL AND SIGNATURE OF THE RESPONSIBLE REGISTRANT APPEARS ON THE DRAWING, AND PROPER PERMIT FORMS AND RELATED FEES ARE TRANSMITTED BY THE OWNER, OWNER'S AGENT OR CONTRACTOR TO THE AUTHORITY HAVING JURISDICTION. 9/28/2012 A.RICCUTTI B.COLBURN 9/20/2012 PALMETTO CAPITAL GROUP 220 East High Street Charlottesville, VA 22903 Office: (434) 295-7131 Contact: Austin Cox DOLLAR GENERAL US HWY 27 & SANDMINE ROAD DAVENPORT, FLORIDA DO NOT SCALE DRAWING JCDT.12.0279 A 2 A3 4" R 24 1'-2 3/4" T/O PARAPET 20'-4" AFF EIFS ON EXTERIOR SHEATHING (SEE FL APPROVAL) 6"x18ga MTL STUD FRAMING AT 16"oc WITH 14ga STUD CLIPS SECURED TO HORZIONTAL GIRTS 3 31 B D 4" 1'-10 1/2" 1'-0 1/2" 8" 24 26 13 17 31 2 6 1/2" 3 A3 • 5'-0" 1 12 1 5 8 28 21 16 18 FINISH FLOOR = 0'-0" T/O PARAPET 20'-4" AFF BUILDING SECTION 20'-4" 9 1 1'-10 1/2" 1'-2 1/2" 2" 5 7 5 A3 15 12 8 28 22 21 6" 15 22 PEMB WALL 6" TYPICAL CORNICE DETAIL 1 3/4" 1'-2 1/2" 1'-4" SCALE 1" = 1'-0" 21 16 WALL SECTION Scale: 1/2" = 1'-0" C 22 Scale: 1/4" = 1'-0" 4 1 10 3 5 1 8 15 12 28 21 16 D 7'-0" 7 31 6 4 24 7 A3 3 A10 30 CONC SIDEWALK SLOPE AWAY FROM BLDG RE: CIVIL "BLOK-FLASH" BASE FLASHING SYSTEM DRAINAGE MAT VERTICAL REINFORCING REF STRUCTURAL WALL SECTION Scale: 1/2" = 1'-0" 3 5 12 14 T/O PARAPET 18'-4" AFF FINISH FLOOR = 0'-0" D 2 7 12 5 31 11 3 10 3 A3 D 1'-3" PEMB WALL 7" 1" 24 /8" -2 3 R1' 19 31 1'-4" D 5 1/4" T/O PARAPET 18'-4" AFF SCALE 1" = 1'-0" 2 31 CONT SOLID 2x WOOD BLOCKING PRE-ENGINEERED METAL BUILDING SYSTEM (BY PREFAB BUILDING MANUFACTURER) KEYED NOTES 1 2 7 6 5 4 ACOUSTICAL DROP CEILING - @10'-0" A.F.F. VINYL FACED R11 INSULATION PRE-FINISHED SOFFIT AND CANOPY (BY PRE-ENGINEERED BUILDING MANUFACTURER) VINYL FACED R19 INSULATION 8" SPLIT FACE CMU (REF EXTERIOR ELEVATIONS) EXTERIOR BUILDING SIGN (BY DOLLAR GENERAL) METAL ROOF - GALVALUME FINISH (BY PREFAB BUILDING MANUFACTURER) 8 PRE-FINISHED DOWNSPOUT & GUTTER (BY PRE-ENGINEERED BUILDING MANUFACTURER) 3 9 10 GC SHALL COORDINATE WITH PRE-ENGINEERED METAL BUILDING MANUFACTURER AND PROVIDE ALL METAL CLOSURE, SEALANT, AND CAULKING TO WEATHERTIGH FINISH GYP BOARD ON 3 5/8" x 20 ga METAL STUDS AT 16" oc (EXTEND TO U/S STEEL) 11 12 CLEAR GLASS TRANSOM AS SCHEDULED LOCATION OF 1 1/2" CONDUIT WITH PULLSTRING (ABOVE OFFICE) FOR SATELLITE LINE. PROVIDE WEATHER TIGHT SEAL AT HORIZONTAL PARAPET PENETRATION. CONTRACTOR RESPONSIBLE FOR INSTALLATION OF CONDUIT. 13 18"x18" INTERIOR WINDOW WITH ONE WAY GLASS CONC SLAB ON VINYL VAPOR BARRIER (REF STRUCTURAL) METAL BUILDING COLUMNS SHALL BE STRAIGHT. TAPERED COLUMNS & INTERIOR COLUMNS REQUIRE WRITTEN APPROVAL. MAINTAIN INTERIOR CLEARANCE OF 68'-1 1/4" BETWEEN FACE OF COLUMNS ON SALES FLOOR. 14 15 16 17 UNDISTURBED EARTH AND COMPACTED SUB GRADE (REF STRUCTURAL AND GEOTECH REPORT) STOREFRONT SYSTEM AS SCHEDULED - COORDINATE WITH FLORIDA PRODUCT APPROVAL INSTALLATION GUIDELINES (REF SHEET A5) 18 EIFS CORNICE ON EXTERIOR GRADE SHEATHING ON METAL WALL PANELS PREPARED GRANNULAR FILL (REF STRUCTURAL) 19 21 REINFORCED CONCRETE FOOTING (REF STRUCTURAL) NOT USED 22 NOT USED 20 23 28 27 26 25 NOT USED INTERIOR WALL PAINTED (REF INTERIOR ROOM FINISH SCHEDULE) COORDINATE DOWNSPOUT CONNECTION TO STORM WITH CIVIL PLANS LIGHTING (REF ELECTRICAL) FINISH GRADE (REF CIVIL DRAWINGS) 24 29 MC CUE TRIM KIT, ORDER KIT "D". PREFINISHED METAL COPING WITH 1/2"/ft SLOPE ON (1) LAYER 3/4" PLYWOOD ON CONT WOOD NALIERS ON (2) LAYERS 3/4" PLYWOOD SECURED TO T/O MASONRY (TYP EIFS CORNICE) 30 31 STRUCTURAL BOND BEAM (REF STRUCTURAL) EIFS SYSTEM ON 5/8" EXTERIOR GRADE SHEATHING ON METAL WALL PANELS (REF EXTERIOR ELEVATIONS) 32 4" 33 D 8" CMU 5 1/4" 4 CONTINUOUS SHIM AND SEALANT EACH SIDE OF STOREFRONT PERIMETER (TYP) SCALE: 1" = 1'-0" STORE FRONT JAMB DETAIL 1'-11 7/8" 1'-2 5/8" 11 7/8" STEEL LINTEL AT STOREFRONT (REF STRUCTURAL) PROVIDE CONT 1/4" SHIM AND SEALANT W/ BACKER ROD (TYP AT PERIMETER) STOREFRONT SYSTEM AS SCHEDULED COORDINATE WITH FLORIDA PRODUCT APPROVAL INSTALLATION GUIDELINES ELASTOMERIC MEMBRANE BETWEEN STEEL AND ALUMIMUM BREAK METAL 6 12 PRE-FINISHED ALUMIMUM BREAK METAL TO MATCH STOREFRONT 15 SYSTEM B/O STEEL 7'-8" AFF PROVIDE CONT 1/4" SHIM AND SEALANT W/ BACKER ROD (TYP AT PERIMETER) AUTOMATIC DOOR SYSTEM AS SCHEDULED - COORDINATE WITH FLORIDA PRODUCT APPROVAL INSTALLATION GUIDELINES SCALE: 1" = 1'-0" STORE FRONT HEAD DETAIL 1'-8 1/2" 1'-3 1/4" TYPICAL CORNICE DETAIL 12 4" 9 1/4" 2 3/4" 14 ga STUD CLIP ON METAL WALL PANEL AT PEMB WALL GIRT REAR PARAPET WALL PANEL BY PEMB 8 A 3 5 1 8 12 28 15 7 22 16 WALL SECTION 3 18'-4" (REF FINISH SCHEDULE) 3'-0" 1'-4" 26'-0" 4'-0" SPLIT FACE CMU 6'-4" 8" 6'-0" 4" 9 1/4" 2 3/4" Scale: 1/2" = 1'-0" 1'-6" 2'-6" 9 19 25 27 2 1/4" 1/4" 1'-8 3/4" 6" 7 3/4" 10'-4" 10'-0" 1'-4" 9'-0" 2'-4" 8" 7'-0" T/O EAVE STRUT (LP) = 14'-0" FINISH FLOOR = 0'-0" 14'-0" Florida Business License: AA26001620 CONSULTANT: SEAL: DONALD FRANCIS BARRY, AR94443 PERMIT 0 REV Dept Mgr Approval B.COLBURN THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION PURPOSES UNTIL THE SEAL AND SIGNATURE OF THE RESPONSIBLE REGISTRANT APPEARS ON THE DRAWING, AND PROPER PERMIT FORMS AND RELATED FEES ARE TRANSMITTED BY THE OWNER, OWNER'S AGENT OR CONTRACTOR TO THE AUTHORITY HAVING JURISDICTION. 9/28/2012 A.RICCUTTI B.COLBURN 9/20/2012 PALMETTO CAPITAL GROUP 220 East High Street Charlottesville, VA 22903 Office: (434) 295-7131 Contact: Austin Cox DOLLAR GENERAL US HWY 27 & SANDMINE ROAD DAVENPORT, FLORIDA DO NOT SCALE DRAWING JCDT.12.0279 IVES WALL MOUNTED DOOR STOP GRAB BAR EWC 1'-6" RAIL ELEV 8" TOILET AND TOILET PAPER HOLDER MIRROR UNIT SEE NOTE #2 20 A3 4'-0" MAX CLEAR FLOOR SPACE FOR LAVATORY FIXTURE BABY CHANGING STATION • 3'-4" CLEAR FLOOR SPACE 4'-0" MIN • 4'-6" MIN 39"-41" EXISTING DOOR NEW EXIT SIGNAGE RE: 21/A3 HAND DRYERCOAT HOOK 3'-4" T.O. HOOK 3'-6" MIN FINISHED FLOOR 8" MIN HC WALL SIGN • INTERNATIONAL SYMBOL OF ACCESSIBILITY HC WALL SIGN SIGNAGE SHALL COMPLY WITH ANSI A117.1 2003 SIGNS SHALL HAVE A NON-GLARE FINISH. CHARACTERS AND SYMBOLS SHALL CONTRAST WITH THEIR BACKGROUND. Scale: 1" = 1'-0" EXIT 3/8" MIN TO 1/2" MAX 4 1" 12 SIGNAGE BACKGROUND TO BE CONTRASTING COLOR TO TEXT. GRADE 2 BRAILLE EITHER CENTERED OR JUSTIFIED LEFT 3/8" TO 1/2" MAX BELOW TACTILE CHARACTERS. SEE ADA ACCESSIBILITY GUIDELINES FOR BRAILLE SPECIFICATIONS. Scale: 6" = 1'-0" 3" 1" 12 IVES WALL-STOP Scale: NTS GRAB BAR DETAIL 34" A.F.F. TACTILE EXIT SIGNAGE DETAIL CONTRACTOR TO VERIFY THAT EXISTING SIGNAGE COMPLIES WITH THIS DETAIL. IF SIGNAGE DOES NOT COMPLY OR DOES NOT EXIST THEN PROVIDE NEW PER DETAILS & AS REQUIRED BY LOCAL AUTHORITIES. TACTILE CHARACTERS TO BE FONT 'SANS SERIF' (ALLUPPERCASE) WITH MAX. HEIGHT OF 2", WIDTH TO HEIGHT RATIO BTWN 3:5 AND 1:1 AND STROKE WIDTH TO HEIGHT RATIO BTWN 1:5 AND 1:10. CHARACTERS SHALL BE RAISED 1/32" FROM SIGN SURFACE. ACCESSIBILITY SIGNAGE HC RESTROOM SIGN LOCATED ON THE WALL ADJACENT TO THE LATCH SIDE OF THE DOOR OR ON THE NEAREST ADJACENT WALL, PREFERABLY ON THE RIGHT 1'-6" 17" - 19" 6" MAX STAINLESS STL. GRAB BAR 4" BASE BASS SECURITY SERVICES, INC. 888-774-3400 EXT. 2024 54-US32D 5410-32D-26D-GRIP DDH-2250 ** DS/1000MB 608Z 770SAV-3FT 770SAV-4FT W101S-DANE-626 W581PD-DANE-626 A-24x36 150Sx36 150Sx42 150Sx18 MS-1 5400 7015SC8-26D * 402-1/2B-26D 452B26D-4 B155 B2740 B253 BURNS PUSH PLATE BURNS PULL PLATE DETEX DOUBLE DOOR HOLDER DOOR SCOPE (FOR RECEIVING EXIT DOOR) 8" DOOR HOLDER 3 FT DOOR SWEEP 4 FT DOOR SWEEP FALCON PASSAGE LEVERSET FALCON STOREROOM LEVERSET GAMCO 24" x 36" ANGLE FRAME MIRROR GAMCO 1 1/2" X 36" GRAB BAR GAMCO 1 1/2" X 42" GRAB BAR GAMCO 1 1/2" X 18" GRAB BAR GAMCO MOP HOLDER HAGER DOOR CLOSER ILCO RIM CYLINDER IVES WALL STOP IVES 4" DOOR HOLDER BOBRICK 24 OZ. SOAP DISPENSER BOBRICK DOUBLE TOILET TISSUE DISPENSER BOBRICK PAPER TOWEL DISPENSER BASS SECURITY PARTS 8400-S32D-8X34 TACO DOOR VIEWER VON DUPRIN GUARD-X EXIT ALARM LOCK VON DUPRIN GUARD-X DOUBLE DOOR STRIKE WEATHERSTRIPPING IVES KICK PLATE NATIONAL GUARD HD THRESHOLD (FOR RECEIVING EXIT DOOR) 425 HD - 6 FT. TA3310PC 2670-28 2609 ** 892SAV-84INCH * MUST HAVE ONE RIM PER EXIT DEVICE. ** MUST HAVE DOUBLE DOOR STRIKE AND TWO DOUBLE DOOR HOLDERS FOR ALL DOUBLE EXIT DOORS. 7. 6. 5. 4. 3. 2. 1. 6"x9" ACCESSIBLE TOILET ROOM SIGNAGE TO BE WHITE TEXT AND SYMBOLS ON BLUE BACKGROUND, TYP. VERIFY REQUIREMENTS WITH LOCAL CODES. CONTRACTOR TO VERIFY LOCATION OF OWNER SUPPLIED TOILET ACCESSORIES WITH ARCHITECT PRIOR TO INSTALLATION. SEE FIXTURE MOUNTING HEIGHTS FOR ALL TOILET ROOM ACCESSORIES. VERIFY HEIGHT WITH LOCAL CODES. INSTALL INSULATION ON ALL EXPOSED PIPES BELOW SINKS AND LAVATORIES TO COMPLY WITH STATE AND LOCAL CODES. CONTRACTOR TO INSTALL SOAP DISPENSERS, TOILET PAPER HOLDERS, DOOR CLOSERS, DOOR HOLDERS, EXHAUST FANS, AND ALL BASS SECURITY PARTS IN BOTH RESTROOMS.FAUCETS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST. PROVIDE AND INSTALL 2'x3' MIRROR (OR LARGER IF REQUIRED BY CODE). RESTROOMS SHALL COMPLY WITH ALL BUILDING (FEDERAL, STATE, AND LOCAL) FIRE, AND HEALTH DEPARTMENT CODES AND ADA REQUIREMENT. REST ROOMS: 8. WHERE WASTE RECEPTACLES, DISPENSERS AND OTHER EQUIPMENT WITH CONTROLS ARE PROVIDED, AT LEAST ONE OF EACH IN EACH TOILET ROOMS SHALL BE LOCATED ON AN ACCESSIBLE ROUTE WITH ALL OPERABLE PARTS WITHIN 48" FROM THE FINISHED FLOOR. MIRROR INSULATE AROUND PIPES 8" MIN 6" MAX 34" MAX 40" TO REAR WALL SOAP DISPENSER 10'-3" 1'-5" MIN 1'-0" 3'-0" MAX 2'-10" T.O. SINK ADA CLEARANCES Scale: NTS 6 2'-3" MIN 2'-8" IVES WALL MOUNTED DOOR STOP 3 24 SOAP DISPENSER PAPER TOWEL HOLDER 3'-0" MIN 1'-6" 2 ROLL TOILET TISSUE HOLDER 4" BASE 18 1/2" 29" MIN FINISHED FLOOR 10'-0" 20'-0" MIRROR W/ FRAME 1'- 6" 4" BASE 4" BASE 36" 40" MAX ADA DRINKING FOUNTAIN (REF PLUMBING) 4" TYP WALL HYDRANT (REF PLUMBING) 10'-512" 17" MIN. 27" MIN 1'-7" MIN. RESTROOM ELEVATIONS 9" MIN 5/8" TO 2" MAX. 1'-6" 40" 3'-0" 3'-2" Scale: NTS 36 3'-9" MIN 3'-4" TO HANDLE 1'-6" 9" MIN 18" MIN. 39"-41" IVES WALL MOUNTED DOOR STOP 18"x18" ONE WAY WINDOW SILL AT 36" AFF CONTRACTOR SHALL LEAVE AN AS-BUILT SET OF CONSTRUCTION PLANS, ROLLED UP AND PLACED INSIDE 4"x36" PVC PIPE MOUNTED HORIZONTALLY ON THE WALL ABOVE THE DOOR 10'-0" 2 29" MIN. 5'-0" (60") 2'-10" 2'-6" MIN 34" MAX 3'-4" RESTROOM/OFFICE/BREAK ROOM PLAN 40" 34" T.O. BAR 7'-4" 5'-0" 7'-2" Scale: 1/4" = 1'-0" 1'-7" 1'-6" 36" 3'-4" 36" CORNER GUARDS, MOUNTED 42" AFF (TYP) PROVIDE 2 ADDITIONAL GUARDS TO FLANK STOREFRONT DOORS 1 1'-6" 1'-6" 9" 5'-4" 10'-1" 5'-0" 7'-7" 1'-0" 2'-3" 3'-0" (MAX) Florida Business License: AA26001620 CONSULTANT: SEAL: DONALD FRANCIS BARRY, AR94443 PERMIT 0 REV Dept Mgr Approval B.COLBURN THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION PURPOSES UNTIL THE SEAL AND SIGNATURE OF THE RESPONSIBLE REGISTRANT APPEARS ON THE DRAWING, AND PROPER PERMIT FORMS AND RELATED FEES ARE TRANSMITTED BY THE OWNER, OWNER'S AGENT OR CONTRACTOR TO THE AUTHORITY HAVING JURISDICTION. 9/28/2012 A.RICCUTTI B.COLBURN 9/20/2012 PALMETTO CAPITAL GROUP 220 East High Street Charlottesville, VA 22903 Office: (434) 295-7131 Contact: Austin Cox DOLLAR GENERAL US HWY 27 & SANDMINE ROAD DAVENPORT, FLORIDA DO NOT SCALE DRAWING JCDT.12.0279 BUILDING DISTANCE FROM STREET: LESS THAN 75' BUILDING DISTANCE FROM STREET: 75' - 175' BUILDING DISTANCE FROM STREET: 175' - 275' BUILDING DISTANCE FROM STREET: 275' AND ABOVE THIS IS THE PRIMARY SIGN FOR ALL LOCATIONS. 16'-1" 23'-0" 26'-0" 33'-3" 1 1" 5'-02 40'-0" 10'-1" THIS SIGN IS USED ON SECONDARY ACCESS LOCATIONS FOR SITES WITH MULTIPLE ACCESS SIGN DETAILS Scale: NTS 8'-0" COMING SOON THIS AREA IS FOR CONTRACTOR AND DEVELOPER USE. SAVE TIME. SAVE MONEY. THIS SIGN IS FOR SPECIALTY USE ONLY. NOT RECOMMENDED FOR PRIMARY SIGNAGE 1" 8'-02 THIS SIGN IS TO BE PROVIDED AND INSTALLED BY THE DEVELOPER OR CONTRACTOR AT THE BEGINNING OF CONSTRUCTION PROJECT. 4'-0" 3'-0" 3'-9" 4'-6" 5'-0" 6'-0" 4'-0" STANDARD SIGN SPECIFICATIONS BOX SIGNS 3' x 23' 5.0 AMPS / 584 WATTS 2.5 AMPS / 292 WATTS 1087 LBS. 695 LBS. 485 LBS. WEIGHT 3'-9" x 26' 5.4 AMPS / 630 WATTS 1400 LBS. AMPS / WATTS 4'-6"x33'-3" 10 AMPS / 1168 WATTS 30 LBS. SIZE 5' x 40' 0.70 AMPS / 65 WATTS INDIVIDUAL LETTERS WARM CLIMATE AMPS COLD CLIMATE AMPS 30MA - 7.88 AMPS 60MA - 15.75 AMPS 30MA - 7.88 AMPS 60MA - 15.75 AMPS 30MA - 9.75 AMPS 60MA - 19.00 AMPS 30MA - 12.00 AMPS 60MA - 24.00 AMPS PYLON SIGNS AMPS / WATTS WEIGHT 400 LBS. 330 LBS. 245 LBS. 210 LBS. WEIGHT 1' x 4' SIZE 18" LTRS. 24" LTRS. 30" LTRS. 36" LTRS. SIZE 389 LBS. 250 LBS. 3.4 AMPS / 396 WATTS 750 LBS. 1.7 AMPS / 198 WATTS 5' x 10' 5.0 AMPS / 584 WATTS 4' x 8' 6' x 16' SIGN SPECIFICATIONS 1. BUILDING SIGNS: PROVIDE CONDUIT FROM ELECTRICAL PANEL TO THE CENTER OF THE SIGN CANOPY. THE CONDUIT IS TO BE 1" AND HAVE ONE SET OF 10/2 WIRE WITH GROUND AND A 20-AMP BREAKER AT THE PANEL. BUILDING CANOPY MUST BE SUFFICIENTLY BUILT TO SUPPORT THE DOLLAR GENERAL SIGN OF UP TO 1400 LBS. NOTE: IF THE LEASE SPECIFIES A 5'-0" X 40'-0" BUILDING SIGN OR 24" LETTER SET (OR LARGER), 2 qty. - 10/2 WIRE WITH GROUND AND 2 qty. 20 AMP CIRCUITS REQUIRED. 2. PYLON SIGNS: PROVIDE CONDUIT FROM ELECTRICAL PANEL TO LOCATION OF THE PYLON SIGN BASE. BURY CONDUIT UNDER PARKING AREA. THE CONDUIT IS TO BE 1" AND HAVE ONE SET OF 10/2 WIRE WITH GROUND AND A 20-AMP BREAKER AT THE PANEL. 4. SEE SHEET A8 FOR SIGN BRACING DETAILS. SEE CHART ABOVE FOR SIGN SPECIFICATIONS. 3. FINAL ELECTRICAL CONNECTIONS FOR SIGN SHALL BE THE OWNERS RESPONSIBILITY AFTER SIGNS ARE INSTALLED. 5. NOTE: SIGNAGE SHALL BE SUBMITTED UNDER SEPARATE PERMIT Florida Business License: AA26001620 CONSULTANT: SEAL: DONALD FRANCIS BARRY, AR94443 PERMIT 0 REV Dept Mgr Approval B.COLBURN THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION PURPOSES UNTIL THE SEAL AND SIGNATURE OF THE RESPONSIBLE REGISTRANT APPEARS ON THE DRAWING, AND PROPER PERMIT FORMS AND RELATED FEES ARE TRANSMITTED BY THE OWNER, OWNER'S AGENT OR CONTRACTOR TO THE AUTHORITY HAVING JURISDICTION. 9/28/2012 A.RICCUTTI B.COLBURN 9/20/2012 PALMETTO CAPITAL GROUP 220 East High Street Charlottesville, VA 22903 Office: (434) 295-7131 Contact: Austin Cox DOLLAR GENERAL US HWY 27 & SANDMINE ROAD DAVENPORT, FLORIDA DO NOT SCALE DRAWING JCDT.12.0279 NOTE: SIGNAGE SHALL BE SUBMITTED UNDER SEPARATE PERMIT Florida Business License: AA26001620 CONSULTANT: SEAL: DONALD FRANCIS BARRY, AR94443 PERMIT 0 REV Dept Mgr Approval B.COLBURN THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION PURPOSES UNTIL THE SEAL AND SIGNATURE OF THE RESPONSIBLE REGISTRANT APPEARS ON THE DRAWING, AND PROPER PERMIT FORMS AND RELATED FEES ARE TRANSMITTED BY THE OWNER, OWNER'S AGENT OR CONTRACTOR TO THE AUTHORITY HAVING JURISDICTION. 9/28/2012 A.RICCUTTI B.COLBURN 9/20/2012 PALMETTO CAPITAL GROUP 220 East High Street Charlottesville, VA 22903 Office: (434) 295-7131 Contact: Austin Cox DOLLAR GENERAL US HWY 27 & SANDMINE ROAD DAVENPORT, FLORIDA DO NOT SCALE DRAWING JCDT.12.0279 GENERAL NOTES THE GENERAL CONTRACTOR IS RESPONSIBLE FOR SITE SAFETY AND CONSTRUCTION MEANS AND METHODS IN THE PERFORMANCE OF THE WORK. PROVIDE ALL MEASURES REQUIRED TO PROTECT THE STRUCTURE, WORKERS AND OTHER PERSONS DURING CONSTRUCTION OPERATIONS. CONTRACTOR TO COMPLY WITH ALL OSHA REGULATIONS, AND ANY OTHER SITE SAFETY REQUIREMENTS OF THE OWNER IN THE PERFORMANCE OF THE WORK. ALL WORK SHALL BE PERFORMED IN A SAFE MANNER AND ALL CONTRACTOR EMPLOYEES SHALL AT ALL TIMES WORK IN COMPLIANCE WITH THE OWNER'S SAFETY REGULATIONS AND ANY GENERAL CONTRACTOR SAFETY REQUIREMENTS. PROVIDE ADEQUATE BRACING AND SHORING FOR CONSTRUCTION EQUIPMENT AND FOR THE BUILDING. PROVIDE SCAFFOLDING, SHEETING, TEMPORARY BARRIERS, BRACING OF EXCAVATIONS AND OTHER TEMPORARY SUPPORTS AS REQUIRED. DO NOT STORE OR STACK CONSTRUCTION MATERIALS ON ERECTED FLOORS OR ROOFS IN EXCESS OF 80 PERCENT OF THE SPECIFIED DESIGN LIVE LOAD. MINIMIZE DYNAMIC IMPACT TO EXISITNG STRUCTURES WHEN PLACING MATERIALS ON FLOORS OR ROOFS. DO NOT OBSTRUCT EXISTING BUILDING DOORS OR EGRESS PATHS DURING THE PERFORMANCE OF THE WORK. CONTRACTOR SHALL CLEAN THE SITE OF CONSTRUCTION DEBRIS TO MAINTAIN A SAFE ENVIRONMENT ON A DAILY BASIS. LEGALLY DISPOSE OF ALL HAZARDOUS AND NON-HAZARDOUS MATERIALS. CONSTRUCTION SITE NOTES: 1. 2. 3. 4. 5. GENERAL COORDINATION NOTES: 6. CONFORM TO ALL OWNER'S GENERAL AND SPECIAL CONDITIONS IN THE PERFORMANCE OF THE WORK OR AS HEREIN SPECIFED. 7. ALL WORK IS TO BE PERFORMED IN ACCORDANCE WITH THE APPLICABLE BUILDING CODE AND ALL APPLICABLE STATE AND LOCAL CODES, ACCESSIBILITY STANDARDS AS WELL AS ANY APPLICABLE OWNER'S CORPORATE STANDARDS. THE LOCAL CODE AUTHORITY HAS THE AUTHORITY TO INTERPRET CODE REQUIREMENTS AND THESE INTERPRETATIONS MAY VARY FROM NORMAL INTERPRETATION AND INFORMATION REPRESENTED IN THE CONTRACT DOCUMENTS. THE CONTRACTOR SHALL INFORM THE OWNER'S REPRESENTATIVE OR THE ARCHITECT/ ENGINEER OF ANY DISCREPANCIES OR DIFFERENCES AND SHALL PROCEED WITH THE WORK ONLY UPON RECEIVING WRITTEN AUTHORIZATION 8. THE DRAWINGS SHALL NOT BE USED FOR CONSTRUCTION PURPOSES UNTIL THE SEAL AND SIGNATURE OF THE RESPONSIBLE REGISTRANT APPEARS ON THE DRAWING, AND PROPER PERMIT FORMS AND RELATED FEES ARE TRANSMITTED BY THE OWNER, OWNER'S AGENT, OR CONTRACTOR TO THE AUTHORITY HAVING JURISDICTION. 9. CONTRACTOR TO OBTAIN ALL REQUIRED CONSTRUCTION PERMIT FORMS, PAY ALL RELATED FEES, AND ARRANGE FOR ALL REQUIRED INSPECTIONS AND APPROVALS. 10. BIDDER/CONTRACTOR SHALL VISIT THE SITE, EXAMINE AND VERIFY EXISTING CONDITIONS UNDER WHICH THE WORK SHALL BE CONDUCTED AND ACCOUNT FOR EXISTING FIELD CONDITIONS AND ACTUAL FIELD DIMENSIONS IN ALL BIDS SUBMITTED AND ALL WORK PERFORMED. REPORT ANY DISCREPANCIES IN THE EXISTING CONDITIONS IMMEDIATELY TO THE OWNER'S REPRESENTATIVE OR ARCHITECT/ ENGINEER 11. CONTRACTOR SHALL REVIEW ALL CONTRACT DOCUMENTS, INCLUDING SPECIFICATIONS, OF INTERFACING TRADES AND OTHER RELATED CONTRACTS PRIOR TO BIDDING AND COMMENCEMENT OF WORK TO ENSURE COMPLETE COORDINATION OF FINISHED WORK. 12. EACH SUBCONTRACTOR IS RESPONSIBLE TO COORDINATE AND SCHEDULE THEIR WORK WITH THE GENERAL CONTRACTOR AND ALL OTHER CONTRACTORS WHO'S WORK WILL BE AFFECTED. SPECIFICATIONS ARE APPLICABLE AND BINDING TO ALL CONTRACTORS AND SUBCONTRACTORS. REPORT ANY DISCREPANCIES, PRIOR TO CONSTRUCTION, TO THE OWNER'S REPRESENTATIVE OR ARCHITECT/ ENGINEER FOR REVIEW AND CLARIFICATION. 13. BEFORE AWARD OF CONTRACT, IF THERE ARE QUESTIONS ABOUT INTENT, CLARITY, APPLICATION OF NOTES, OR WORK SHOWN OR SPECIFIED, OR IF CONFLICTING DIRECTIONS ARE FOUND IN THE DOCUMENTS, THE GENERAL CONTRACTOR SHALL REQUEST WRITTEN CLARIFICATION FROM THE OWNER'S REPRESENTATIVE OR ARCHITECT/ ENGINEER. ANY CLARIFICATIONS OR INTREPRETATIONS OF THE CONTRACT DOCUMENTS PROVIDED AFTER CONTRACT AWARD SHALL BE AT NO ADDITIONAL COST. 14. CONTRACTOR SHALL NOT SCALE DRAWINGS FOR CONSTRUCTION PURPOSES. IN THE EVENT OF AN OMMISSION OF NECESSARY DIMENSIONS OR INFORMATION, CONTRACTOR SHALL NOTIFY THE OWNER'S REPRESENTATIVE OR ARCHITECT/ ENGINEER. FIGURED AND CALCULATED DIMENSIONS TAKES PRECEDENCE OVER SCALED MEASUREMENTS. DETAIL DRAWINGS AND LARGER SCALE DRAWINGS TAKES PRECEDENCE OVER SMALLER SCALE DRAWINGS. ALL PLAN DETAILS AND WALL SECTIONS ARE ASSUMED TO BE TYPICAL CONDITIONS UNLESS DETAILED OR NOTED OTHERWISE. 15. SOME STANDARD SYMBOLS, ABBREVIATIONS AND DETAILS INDICATED IN CONTRACT DOCUMENTS MAY NOT BE APPLICABLE TO THIS SPECIFIC CONTRACT ISSUE. 16. DRAWING DETAILS ARE CONCEPTUAL IN NATURE AND ACTUAL FIELD CONDITIONS MAY VARY SLIGHTLY FROM CONCEPTUAL DEPICTIONS. DETAILS LABELED "TYPICAL DETAILS" ON DRAWINIGS APPLY TO SITUATIONS THAT ARE THE SAME OR SIMILAR TO THOSE SPECIFICALLY DETAILED. SUCH DETAILS APPLY WHETHER OR NOT DETAILS ARE REFERENCED AT EACH LOCATION 17. SUBSTITUTIONS ARE SUBJECT TO THE APPROVAL OF THE OWNER. IF A SUBSTITUTION IS PROPOSED, SUBMIT COMPLETE SPECIFICATION AND PERFORMANCE DETAILS FOR EVALUATION. IF SUBSTITUTIONS ARE APPROVED, NOTIFY ALL OTHER CONTRACTORS AND SUBCONTRACTORS AFFECTED BY THE CHANGE AND FULLY COORDINATE ALL RELATED WORK. ANY COSTS RESULTING FROM THE SUBSTITUTION AND CHANGE IS THE RESPONSIBILITY OF THE CONTRACTOR. 18. COORDINATE AND PERFORM WORK BASED ONLY ON REVIEWED/ CERTIFIED SHOP DRAWINGS, A FIELD CHECK OF EXISTING CONDITIONS, AND INSPECTION OF NEWLY INSTALLED WORK. VERIFY THE LATEST REVISION OF CONTRACT DOCUMENTS, INCLUDING ALL INTERFACING DISCIPLINE DRAWINGS, BEFORE PROCEEDING WITH THE PROCUREMENT, DETAILING, FABRICATION OR INSTALLATION OF THE WORK. ANY SYSTEMS OR EQUIPMENT INSTALLED PRIOR TO REVIEW OF SHOP DRAWINGS BECOMES THE RESPONSIBILITY OF THE CONTRACTOR. 19. ALL EQUIPMENT SHALL BE INSTALLED IN FULL ACCORDANCE WITH MANUFACTURER'S DATA AND INSTALLATION INSTRUCTIONS. IT IS THE CONTRACTOR'S RESPONSIBILTY TO CHECK AND CONFORM TO MANUFACTURER SPECIFICATIONS AND REQUIREMENTS PRIOR TO STARTING THE WORK. VERIFY SIZE, LOCATIONS AND CHARACTERISTICS OF ALL EQUIPMENT TO BE FURNISHED WITH MANUFACTURER OR SUPPLIERS BEFORE COMMENCEMENT OF CONSTRUCTION. VERIFY SIZE AND LOCATIONS OF ALL OPENINGS AND SUPPORTS WITH ACTUAL EQUIPMENT PURCHASED. REFER TO MANUFACTURERS STANDARD DETAILS FOR INSTALLATION. 20. ALL EQUIPMENT AND SYSTEMS SHALL BE COMPLETE AND OPERATIONAL IN ALL RESPECTS, SECURED IN LOCATION AND PROPERLY ADJUSTED. PROVIDE OPERATIONS AND MAINTENANCE MANUALS FOR THE OWNER AT THE COMPLETION OF THE WORK. 21. FULLY WARRANT ALL MATERIALS, EQUIPMENT AND WORKMANSHIP FOR ONE (1) YEAR FROM DATE OF ACCEPTANCE, UNLESS OTHERWISE SPECIFIED. REPAIR OR REPLACE WITHOUT CHARGE TO THE OWNER ALL ITEMS FOUND DEFECTIVE DURING THE WARRANTY PERIOD. 22. BEFORE PENETRATING EXISTING CONCRETE OR SOIL SURFACES, CONSULT WITH ALL LOCAL UTILITIES' PROGRAMS FOR THE AREA OF WORK AND VERIFY LOCATION OF ALL EXISTING UNDERGROUND UTILITIES AND STRUCTURES BY USE OF "ELECTRONIC" OR SIMILAR NON-INVASIVE DETECTOR DEVICES. IF POTENTIAL INTERFERENCES ARE DISCOVERED, PROPOSE ALTERNATE ROUTING AND ASSOCIATED COSTS TO THE OWNER'S REPRESENTATIVE OR ARCHITECT/ENGINEER FOR APPROVAL BEFORE PROCEEDING. 23. MAINTAIN MINIMUM CLEARANCE REQUIREMENTS OF EQUIPMENT MANUFACTURER'S SPECIFICATIONS OR RECOMMENDATIONS, OWNER STANDARDS, NATIONAL ELECTRICAL CODE (NEC), AND ALL APPLICABLE FEDERAL, STATE AND LOCAL CODES, AND REGULATIONS. 24. MAINTAIN A MINIMUM OF 6' 8" HEADROOM CLEARANCE FOR BULKHEADS, SUPPORTS AND UTILITIES PASSING OVER WALKWAYS, PLATFORMS OR CATWALKS. ARCHITECTURAL NOTES: 25. ALL FINISH FLOOR ELEVATIONS ARE FOR ARCHITECTURAL PURPOSES ONLY. REFER TO CIVIL AND STRUCTURAL DRAWINGS FOR ACTUAL ELEVATIONS AND RELATIONSHIP TO SITE BENCHMARKS. 26. COORDINATE WITH MECHANICAL CONTRACTOR THE LOCATIONS OF ALL FLOOR DRAINS. 27. TRANSITION OF DIFFERENT FLOORING MATERIALS AT DOORWAYS SHALL OCCUR AT CENTERLINE OF DOORS AND SHALL BE ½" HIGH MAXIMUM. 28. ALL PLAN DIMENSIONS ARE TO FINISHED FACE OF FINISHED WALLS, FACE OF MASONRY, AND CENTERLINE OF COLUMNS, UNLESS NOTED OTHERWISE. 29. PARTITIONS ARE TO EXTEND AND SEAL AGAINST THE BOTTOM OF THE DECK ABOVE UNLESS OTHERWISE NOTED. 30. INSTALL METAL TRIM ON ALL GYPSUM BOARD EDGES ABUTTING OTHER MATERIALS OR WHERE GYP BD STOPS SHORT OF OTHER MATERIALS TO FORM A REVEAL OR RECESS. USE METAL CORNER BEAD ON ALL GYPSUM BOARD EXTERIOR CORNERS. 31. ADD SUFFICIENT BLOCKING IN STUD WALLS TO SUPPORT ALL ITEMS OR EQUIPMENT SHOWN OR SPECIFIED TO BE ATTACHED TO WALLS. PROVIDE ADDITONAL STRUCTURAL SUPPORT (PLATES, ANGLES, CHANNELS, ETC.) WITHIN WALLS WHERE WEIGHT OF ATTACHED ITEMS EXCEED WALL CAPACITY. PROVIDE BACKING PLATES OR BLOCKING FOR ANY OWNER FURNISHED OR INSTALLED ITEMS. 32. PAINT ALL WALL SURFACES, DOOR FRAMES, BULKHEADS AND CEILINGS IN ROOMS WHERE INDICATED ON PLANS OR ROOM FINISH SCHEDULE. PAINT BEHIND ALL MOVEABLE ITEMS ADJACENT TO WALLS RECEIVING PAINT AND RELOCATE ITEMS AS NECESSARY. 33. ALL EXTERIOR SURFACES TO HAVE A TEMPORARY OR PERMANENT WEATHER RESISTIVE BARRIER DURING CONSTRUCTION OPERATIONS TO PROTECT THE BUILDING INTERIOR AND WALL SURFACES. EXTERIOR OPENINGS SHALL BE FLASHED IN SUCH A MANNER AS TO MAKE THEM WATERPROOF. 34. THE AREA OF WORK SHALL BE MAINTAINED WEATHERTIGHT AND IN A SECURED CONDITION AT ALL TIMES. THE CONTRACTOR SHALL TAKE ALL PRECAUTIONS NECESSARY TO SECURE THE AREA OF WORK. 35. REFER TO FLOOR AND REFLECTED CEILING PLANS AND MECHANICAL AND ELECTRICAL DRAWINGS FOR SPACE ALLOCATIONS IN ROUTING OF ALL MECHANICAL AND ELECTRICAL WORK INCLUDING DIFFUSERS, REGISTERS, GRILLES, LIGHTS, ETC. THE REFLECTED CEILING PLAN LOCATIONS SHALL BE ADHERED TO UNLESS OTHERWISE NOTED ON DRAWINGS. EXCEPTIONS SHALL REQUIRE SPECIFIC WRITTEN APPROVAL BY THE OWNER'S REPRESENTATIVE OR ARCHITECT/ ENGINEER. NOTE THAT ELECTRIC LIGHT FIXTURE LOCATIONS AND FIRE SPRINKLER HEADS SHALL TAKE PRECEDENCE OVER OTHER UTILITY ITEMS IN ANY AND ALL LOCATIONS FOR AREAS WITH OR WITHOUT CEILINGS; THE CONTRACTOR SHALL COORDINATE AS REQUIRED, AND IF THERE IS NO APPARENT SOLUTION TO COORDINATION ISSUE, CONTACT THE OWNER'S REPRESENTATIVE OR ARCHITECT/ ENGINEER FOR A RESOLUTION. 36. REFER TO STRUCTURAL DRAWINGS FOR SUPPORT STRUCTURE INFORMATION, DETAILS AND DIMENSIONS NOT INDICATED ON THE ARCHITECTURAL DRAWINGS. REPORT ANY DISCREPANCIES BETWEEN THE ARCHITECTURAL AND STRUCTURAL DRAWINGS TO THE ARCHITECT/ ENGINEER OR OWNER'S REPRESENTATIVE, PRIOR TO CONSTRUCTION. 37. COORDINATE MECHANICAL AND ELECTRICAL EQUIPMENT CONCRETE PADS AND ROOF CURB LOCATIONS, SIZES, SUPPORTS AND CONSTRUCTION REQUIREMENTS, ONLY WITH REVIEWED AND CERTIFIED SHOP DRAWINGS OF THE RELATED TRADES. 38. REFER TO AND COORDINATE WITH STRUCTURAL DRAWINGS FOR ALL FLOOR AND EXTERIOR WALL PENETRATIONS. INSULATE AND WATERTIGHT SEAL ALL EXTERIOR WALL PENETRATIONS. 39. REFER TO MECHANICAL AND ELECTRICAL DRAWINGS AND THE SPECIFICATIONS FOR WALL, FLOOR AND BUILDING SURFACES PENETRATION AND SEALING REQUIREMENTS. FIRE STOP ALL PENETRATIONS OF FIRE RATED WALL OR FIRE RATED FLOOR OPENINGS PER TESTED UL ASSEMBLIES AND AS REQUIRED BY CODE. 40. PROVIDE WALL AND CEILING ACCESS DOORS AS MAY BE REQUIRED BY CODE OR TO PROPERLY SERVICE OR ADJUST ALL VALVES, DAMPERS, CLEAN OUTS, ELECTRICAL JUNCTION BOXES AND OTHER DEVICES. DEMOLITON NOTES: 41. 42. 43. 44. 45. 46. PLAN AND SCHEUDLE CONSTRUCTION AND DEMOLITION ACTIVITIES TO AVOID INTERFERENCE AND TO MINIMIZE DISRUPTION OF THE OWNER'S OPERATIONS. SCHEDULE AND COORDINATE ALL DEMOLITION WORK AND UTILITY SHUT DOWNS AND TIE INS WITH THE OWNERS REPRESENTATIVE. PROCEED WITH WORK ONLY AFTER RECEIPT OF WRITTEN AUTHORIZATION. DEMOLISHED MATERIALS, UNLESS OTHERWISE DIRECTED, SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND SHALL BE PROMPTLY REMOVED FROM THE SITE BEFORE THE END OF EACH WORKDAY. OWNER RETAINED SALVAGED EQUIPMENT SHALL BE PROPERLY PROTECTED FOR REUSE OR CRATED FOR PROTECTION AND DELIVERED TO THE OWNER'S SITE STORAGE. ALL HAZARDOUS AND NON-HAZARDOUS MATERIALS SHALL BE PROPERLY DISPOSED OF OFF SITE AND PER ALL APPLICABLE FEDERAL, STATE AND LOCAL CODES. PERFORM CONSTRUCTION AND SELECTIVE DEMOLITION IN A MANNER TO PREVENT DAMAGE TO ANY EXISTING AND NEW STRUCTURES, UTILITIES AND OTHER PROPERTY. ALL CUTTING AND CHASING OF BUILDING CONSTRUCTION SHALL BE IN A NEAT AND WORKMANLIKE MANNER. NEATLY SAWCUT ALL RECTANGULAR OPENINGS, SET SLEEVES THROUGH OPENINGS, AND FINISH PATCH OR PROVIDE TRIM AROUND OPENINGS. CORE DRILL AND SLEEVE ALL ROUND OPENINGS. REPAIR SURFACES THAT HAVE BEEN DAMAGED BY THE WORK. REPAIR DAMAGE TO MATCH EXISTING CONSTRUCTION, INCLUDING BUT NOT LIMITED TO WEATHER AND FIRE SEALING, INSULATING, PATCHING AND PAINTING TO MATCH. MISCELLANEOUS SUPPORT RELATED NOTES: 47. PROVIDE SUPPLEMENTARY OR MISCELLANEOUS STEEL FOR SUPPORT, SWAY BRACING, CROSS BRACING, AND ANCHORAGE OF BUILDING SYSTEMS OR UTILITIES, IN ORDER TO MEET SITE SEISMIC AND SYSTEM SPECIFIC INSTALLATION AND OPERATING CONDITIONS. 48. COORDINATE SUPPLEMENTARY OR MISCELLANEOUS STEEL WITH THE PRIMARY STRUCTURAL STEEL WORK. SUPPORT, BRACE, CROSS BRACE, GUIDE AND ANCHOR AS REQUIRED SO AS TO IMPOSE NO OVERSTRESSING OF THE BUILDING STRUCTURE BEYOND STATED LOADS INDICATED ON THE STRUCTURAL DRAWINGS. 49. DO NOT WELD TO, CUT OR DRILL BUILDING STEEL. 50. DO NOT WELD SUPPLEMENTARY OR MISCELLANEOUS STEEL TO BUILDING STEEL WITHOUT PRIOR WRITTEN APPROVAL OF PROPOSED DETAIL BY THE STRUCTURAL ENGINEER. WELDING TO SUPPLEMENTARY STEEL IS PERMITTED. 51. DO NOT HANG SUPPORTS FROM TOP CHORD OF TRUSS. USE ONLY APPROVED BEAM CLAMPS, C CLAMPS ARE PROHIBITED. B. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. CONFORM TO ALL APPLICABLE CODES AND GOVERNMENT REGULATIONS. OBTAIN PERMITS AND PAY ALL FEES. ARRANGE FOR ALL REQUIRED INSPECTIONS AND APPROVALS. REVIEW FOR THE GENERAL BUILDING PERMIT WILL BE OBTAINED BY THE ARCHITECT. PERMIT FEE IS BY THE CONTRACTOR. CODES, STANDARDS AND REGULATIONS CONFORM TO ALL GENERAL AND SPECIAL CONDITIONS OF CONTRACT AS SPECIFIED BY ARCHITECT AND OWNER. SPECIFICATIONS ARE APPLICABLE TO ALL CONTRACTORS AND/OR SUBCONTRACTORS. CHECK OTHER PLANS AND SPECIFICATIONS AND FULLY COORDINATE WITH OTHER SYSTEMS ON GRADES. VISIT SITE, CHECK FACILITIES AND CONDITIONS, VERIFY ALL UTILITY CONNECTIONS, AND TAKE ALL ITEMS INTO CONSIDERATION IN BID. SYSTEMS ARE TO BE COMPLETE AND WORKABLE IN ALL RESPECTS, PLACED IN OPERATION AND PROPERLY ADJUSTED. EACH CONTRACTOR SHALL PROVIDE FOR HIS OWN CLEAN UP, REMOVAL AND LEGAL DISPOSAL OF ALL RUBBISH ON A DAILY BASIS. FULLY COORDINATE ALL WORK AND COOPERATE COMPLETELY WITH OTHER CONTRACTORS, SUBCONTRACTORS AND OWNER. CONTRACTORS MUST CONFIRM ALL UTILITY CONNECTION POINTS IN FIELD, PRIOR TO STARTING WORK. ARRANGE FOR AND OBTAIN OWNER'S PERMISSION FOR ANY SERVICE SHUTDOWNS REQUIRED UNDER THIS CONTRACT. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, SEQUENCES OF CONSTRUCTION, AND THE SAFETY OF WORKERS. CUTTING, PATCHING AND DRILLING 1. PROVIDE CLASS PB EIFS CONSISTING OF FABRIC SHALL BE ALKALI RESISTANT, OPEN WEAVE FIBER FABRIC WITH TENSILE STRENGTH OF NOT LESS THAN 200 LBS. MANUFACTURER: STO CORP (888)786-3437; STOTHERM LOTUSAN NEXT SYSTEM -OR- APPROVED EQUAL PROVIDE ALL LABOR, MATERIALS, SERVICES AND EQUIPMENT NECESSARY FOR ALL WORK INCLUDED FOR THE EXTERIOR INSULATED AND FINISH WALL SYSTEM. DENS GLASS GOLD SHEATHING (AT METAL STUD FRAMING), RIGID MOLDED CELLULAR INSULATION, ADHESIVE, REINFORCING FABRIC, BASE COAT, FINISH COAT AND ALL ACCESSORIES. 5. 4. 3. 2. 1. FINISH SHALL BE KYNAR 500 FLUOROCARBON COATING. COLOR AS NOTED ON THE DRAWINGS. GUTTER AND DOWNSPOUT SIZE AS NOTED ON THE DRAWINGS. PROVIDE STRAPS AND BRACKETS AS REQUIRED. GUTTERS, AND DOWNSPOUTS SHALL BE PREFINISHED G90 HOT DIPPED GALVANIZED STEEL, MINIMUM 22 GAUGE. MISCELLANEOUS SHEET METAL ACCESSORIES - METAL FLASHING AND COPINGS SHALL BE PREFINISHED G90 HOT DIPPED GALVANIZED STEEL, MINIMUM 22 GAUGE INTERLOCKING 2 PART TYPE CONSTRUCTION. PROVIDE ALL LABOR, MATERIALS, SERVICES AND EQUIPMENT NECESSARY TO COMPLETE ALL WORK ASSOCIATED WITH FLASHING AND SHEET METAL TO INCLUDE, BUT NOT LIMITED TO: METAL FLASHING AND COPINGS METAL COUNTERFLASHINGS AND REGLETS. GUTTERS, DOWNSPOUTS AND SCUPPER. 6. 5. 4. 3. 2. 1. CORNERS TO BE WELDED. FORM EXTERIOR FRAMES OF 16 GAUGE FOR 1-3/4" DOORS, FLUSH DOUBLE RABBETED TYPE WITH 5/8" DEEP STOPS IN 2" FACE. PROVIDE METAL FRAME FOR DOORS, FABRICATED WITH MITERED CORNERS. WHERE FIRE RATED DOOR ASSEMBLIES ARE INDICATED OR REQUIRED PROVIDE DOOR AND FRAME ASSEMBLIES THAT COMPLY WITH NFPA 80. HIGH DOORS, COMPLYING WITH STEEL DOOR INSTITUTE (SDI) RECOMMENDED SPECIFICATIONS. HINGED DOOR AND FRAMES DESCRIBED HEREIN ARE FOR A MAX. OF 4 FT. WIDE AND 8 FT. PROVIDE ALL LABOR AND MATERIALS, SERVICES AND EQUIPMENT NECESSARY TO COMPLETE ALL WORK ASSOCIATED WITH STEEL DOORS AND FRAMES. 20. INSTALL FINISH HARDWARE AS SPECIFIED IN DOOR HARDWARE SCHEDULE. 19. APPLY 3 MIL THICK BITUMINOUS COATING INSIDE OF BOTH INTERIOR AND EXTERIOR DOOR FRAMES THAT WILL BE FILLED WITH MORTAR. 18. EXCEPT ON WEATHER-STRIPPED FRAMES, DRILL STOPS TO RECEIVE 3 SILENCERS ON JAMB STRIKES OF FRAMES FOR SINGLE DOORS, 2 SILENCERS ON HEADS OF FRAMES FOR PAIR OF DOORS. 17. FURNISH JAMB ANCHORS NOT LESS THAN 3 PER JAMB, AS REQUIRED TO SECURE FRAMES TO ADJACENT CONSTRUCTION. FORMED OF NOT LESS THAN 18 GAUGE GALVANIZED STEEL. 16. INTERIOR FRAMES SHALL BE 18 GAUGE WITH KNOCK - DOWN CONSTRUCTION. 15. EXTERIOR DOORS SHALL BE GALVANIZED FLUSH TYPE WITH INSULATION. 7. SECTION 08110 STEEL DOORS AND FRAMES and DOORS AND WINDOWS 6. SECTION 07600 FLASHING AND SHEET METAL 2. SECTION 07240 EXTERIOR INSULATION AND FINISH SYSTEM (E.I.F.S.) ARCHITECTURAL SPECIFICATIONS GENERAL INFORMATION 1. 2. 3. BASE EQUIPMENT, MATERIALS AND SUBSTITUTIONS GENERAL C. A. 1. 2. D. ALL CUTTING AND CHASING OF THE BUILDING CONSTRUCTION AS REQUIRED SHALL BE IN A NEAT AND PROFESSIONAL MANNER. NEATLY SAW CUT ALL RECTANGULAR OPENINGS, SET SLEEVE THROUGH OPENING, AND FINISH PATCH OR PROVIDE TRIM FLANGE AROUND OPENING. CORE DRILL AND SLEEVE ALL ROUND OPENINGS. DO NOT CUT ANY STRUCTURAL COMPONENTS WITHOUT ARCHITECT'S APPROVAL. PATCH AND FINISH TO MATCH ADJACENT AREAS THAT HAVE BEEN CUT, DAMAGED OR MODIFIED AS A RESULT OF THE INSTALLATIONS OF THE MECHANICAL OR ELECTRICAL EQUIPMENT. FIRE STOP ALL PENETRATIONS OF FIRE RATED CONSTRUCTION IN A CODE APPROVED MANNER. 5. 4. 3. ALL EQUIPMENT AND MATERIALS SHALL BE NEW AND FREE OF DEFECTS. BASE EQUIPMENT MANUFACTURER, MODEL, AND CAPACITY OF EQUIPMENT ARE LISTED ON THE DRAWINGS OR IN THIS SPECIFICATION. ANY OTHER MANUFACTURER IS CONSIDERED A SUBSTITUTION. SUBSTITUTIONS ARE SUBJECT TO THE APPROVAL OF THE OWNER. IF A SUBSTITUTION IS SUBMITTED, INCLUDE COMPLETE PERFORMANCE FACTS FOR EVALUATION. IF SUBSTITUTIONS ARE APPROVED, NOTIFY ALL OTHER CONTRACTORS, SUBCONTRACTORS OF TRADES AFFECTED BY SUBSTITUTION AND FULLY COORDINATE. ANY COSTS RESULTING FROM SUBSTITUTION, WHETHER BY CONTRACTORS OR OTHERS, SHALL BE RESPONSIBILITY OF AND PAID FOR BY SUBSTITUTING CONTRACTOR. ALL EQUIPMENT SHALL BE INSTALLED IN FULL ACCORDANCE WITH THE MANUFACTURER'S DATA AND INSTALLATION INSTRUCTIONS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO CHECK AND CONFORM TO THESE REQUIREMENTS PRIOR TO STARTING WORK. 1. 2. 3. 4. 5. WARRANTY PROVIDE AND INSTALL ALUMINUM AND GLASS SLIDING DOOR SYSTEM AND STOREFRONT SYSTEM, AS INDICATED ON THE DRAWINGS. E. 1. INCLUDE ALL FRAMING, BRAKE METAL TRIM, SUPPORTS, CLIPS, BRACKETS, CLOSURES, ETC, AS REQUIRED FOR A COMPLETE STOREFRONT AND ENTRANCE NSTALLATION. 1. ALUMINUM DOOR ENTRANCES, STOREFRONTS AND GLASS WOOD DOORS SECTION 08210 PROVIDE ALL LABOR AND MATERIALS, SERVICES AND EQUIPMENT NECESSARY TO COMPLETE ALL WORK ASSOCIATED WITH SPECIAL DOORS. SOLID CORE WOOD DOORS SHALL HAVE BIRCH VENEER - STAIN GRADE WITH SOLID PARTICLE BOARD CORE PER ANSI A208.1, GRADE LD-1. 2. ALLOW FOR EXPANSION AND CONTRACTION RESULTING FROM AMBIENT TEMPERATURE RANGE OF 120 DEGREES F. PROVIDE FULL WARRANTY ON ALL MATERIALS, EQUIPMENT AND WORKMANSHIP FOR ONE (1) YEAR FROM DATE OF ACCEPTANCE, UNLESS NOTED OTHERWISE. EXTEND ALL MANUFACTURER'S WARRANTIES TO OWNER, INCLUDING FIVE (5) YEAR HEAT EXCHANGER EXTENDED WARRANTY ON HVAC EQUIPMENT. REPAIR OR REPLACE WITHOUT CHARGE TO THE OWNER ALL ITEMS FOUND DEFECTIVE DURING THE WARRANTY PERIOD. 3. PROVIDE CAPACITY TO MEET ALL REQUIRMENTS AS OUTLINE IN FLORDIA THE PRODUCT APPROVAL DESIGN GUIDELINES. 2. 3. 4. INCLUDE TRANSOM FRAMING AS INDICATED ON THE DRAWINGS. SECTION 08410 5. INCLUDE ALL SAFETY RAILS AND ACCESSORIES AS REQUIRED BY LOCAL AUTHORITIES. SHOP DRAWINGS 6. ALL EXTERIOR STOREFRONT FRAMING SYSTEMS SHALL BE "THERMAL BREAK" CONSTRUCTION. KAWNEER SYSTEM "TRI-FAB 451-T" OR APPROVED EQUAL F. 7. ALUMINUM AND GLASS STOREFRONT SYSTEM SHALL COMPLY WITH THE PROVISIONS AAMA "METAL CURTAINWALL, WINDOW, STOREFRONT AND ENTRANCE GUIDESPECIFICATIONS MANUAL". 1. 8. ALUMINUM MEMBERS SHALL MEET ASTM 8221 FOR EXTRUSIONS. PROVIDE JOB SPECIFIC INFORMATION ON REPRODUCIBLE SHEETS WITH GRAPHIC INFORMATION AT ACCURATE SCALE. CONTRACTOR IS RESPONSIBLE TO CHECK ALL SUBMITTALS. PROVIDE SUBMITTALS FOR THE FOLLOWING ITEMS: CONCRETE DESIGN MIX. ALL STRUCTURAL & MISCELLANEOUS STEEL MASONRY & ACCESSORIES METAL GUTTER & DOWNSPOUTS SECTION 03300 - CAST IN PLACE CONCRETE REFER TO STRUCTURAL DRAWINGS 9. CONCRETE 2. A) B) C) D) MASONRY 10. ASTM B209 FOR SHEET/PLATE. 1. SEE WALL SECTIONS FOR INSULATION THICKNESS. FOAMED-IN-PLACE MASONRY INSULATION SHALL BE CORE-FILL 500 MANUFACTURED BY TAILORED CHEMICAL PRODUCTS -OR- APPROVED EQUAL INSULATION PROVIDE ALL LABOR, MATERIALS, SERVICES AND EQUIPMENT NECESSARY FOR INSULATION WORK TO INCLUDE BUT NOT NECESSARILY BE LIMITED TO: INSULATION SHALL BE EXTRUDED POLYSTYRENE BOARD INSULATION FOR USE BELOW GRADE. 1. REFER TO THE DRAWINGS FOR ADDITIONAL ITEMS. PROVIDE LABOR, MATERIALS, SERVICES AND EQUIPMENT NECESSARY FOR COMPLETE INSTALLATION OF FINISH HARDWARE. 8. 7. 6. 5. 4. 3. 2. 1. APPLY TREATMENT AT GYPSUM BOARD JOINTS, INCLUDING JOINT TAPE AT ALL JOINTS BETWEEN GYPSUM BOARDS AND MIN. 2 COATS GYPSUM JOINT COMPOUND (OMIT THIRD COAT AND SANDING ON CONCEALED DRYWALL WORK) PROVIDE CONTROL JOINTS IN WALLS AT NOT MORE THAN 30' SPACING AND IN SOFFITS NOT EXCEEDING 50' SPACING, OR AS INDICATED ON THE DRAWINGS. PROVIDE MANUFACTURER'S STANDARD TRIM ACCESSORIES, INCLUDING BUT NOT LIMITED TO CORNER BEAD, L TYPE EDGES, TRIM BEDS, U TYPE EDGE TRIM BEAD, SPECIAL L CURVED TYPE EDGE TRIM BEAD AND ONE PIECE CONTROL JOINT BEAD. INSTALL WATER RESISTANT GYPSUM BOARD, PER ASTM C30 AT TOILETS, SERVICE SINK, ALL SINKS AND FLOOR DRAIN AREAS. FOR LOADING REFER TO THE DRAWINGS FOR MINIMUM GAUGE. ADJUST GAUGE AS REQUIRED FOR UNSUPPORTED LENGTH PER 5 PSF. GYPSUM BOARD INSTALLATION WILL BE ON METAL STUDS OR FURRING @ 16" ON CENTER UNLESS OTHERWISE NOTED. PROVIDE GYPSUM BOARD AS INDICATED ON THESE DRAWINGS, AS MANUFACTURED BY DOMTAR GYPSUM AMERICA, INC., GOLD BOND BLDG. PRODUCTS, AND US GYPSUM CO. PROVIDE AND INSTALL GYPSUM DRYWALL AS INDICATED ON THESE DRAWINGS, AND PER ASTM C11 OR GA-505 BY THE GYPSUM ASSOCIATION. ACOUSTIC CEILING & GRID SECTION 009510 1. INTERIOR ACOUSTIC CEILING TILES TO BE 5/8" x 24" x 48" STANDARD FISSURE TILE IN 15/16" WHITE GALVANIZED SUSPEND GRID. INSTALL PER MANUFACTURERS REQUIREMENTS. EXTERIOR ACOUSTIC CEILING TO BE 5/8" x 24" x 48" EXTERIOR FISSURE TILE IN 15/16" WHITE GALVANIZED SUSPENDED GRID. ARMSTRONG - CERAMAGUARD OR EQUAL. PROVIDE HOLD DOWN CLIPS. INSTALL PER MANUFACTURERS REQUIREMENTS. PAINTING SECTION 09900 1. PROVIDE ALL LABOR AND MATERIALS AS NECESSARY FOR FINISHES AS INDICATED IN THESE SPECIFICATIONS. 2. ACCEPTABLE PAINT MANUFACTURERS INCLUDE: SHERWIN WILLIAMS, PPG, AND BENJAMIN MOORE 3. ALL FINISHES AND MATERIALS TO RECEIVE PAINT SHALL BE CLEANED THOROUGHLY AND PREPARED PER MANUFACTURES RECOMMENDATIONS. 4. INTERIOR DRYWALL 4.1. 1 COAT LATEX PRIMER 4.2. 2 COATS LATEX EGGSHELL 5. INTERIOR WOOD DOORS. 5.1. 1 COAT OPEN GRAIN WOOD FILLER 5.2. 2 COATS WOOD SATIN POLYURETHANE SEALER 6. INTERIOR HOLLOW METAL FRAMES AND DOORS 6.1. 1 COAT FACTORY PRIME COAT 6.2. 2 COATS SPREAD LUSTER SEMI-GLOSS ENAMEL 7. EXTERIOR METAL 7.1. 1 COAT PRIMER (IF NOT FACTORY PRIMED) 7.2. 2 COATS SPREAD LUSTER SEMI-GLOSS ENAMEL 8. SEE ROOM FINISH SCHEDULE SHEET A4 FOR SPECIFIC COLORS. 2. 3. 4. 5. 10. EXTERIOR GYPSUM SHEATHING - 5/8" DENS-GLASS GOLD PER ASTM. C79. - OR - APPROVED EQUAL 9. SECTION 09250 GYPSUM DRYWALL FINISHES 2. SECTION 08710 FINISH HARDWARE 17. PROVIDE 1/4" GLASS IN DOORS AS INDICATED IN THE DRAWINGS. 16. ALUMINUM FRAME & BRAKE METAL SHALL HAVE FINISH PER EXTERIOR FINISH SCHEDULE. 15. ALL GLASS SHALL BE CLEAR UNLESS OTHERWISE NOTED. 14. PROVIDE TEMPERED GLASS ADJACENT TO ENTRY DOORS OR AS REQUIRED BY LOCAL AUTHORITIES. INTERIOR GLASS SHALL BE 1/4" TEMPERED GLASS 13. GLASS SHALL BE 1/4" THICK PANES WITH 1/2" AIR SPACE WITH A LOW-E COATING. 12. BRAKE METAL SHALL BE 0.050 THICKNESS. PROVIDE 1" INSULATED UNITS AT EXTERIOR. 11. STEEL REINFORCEMENT SHALL BE HOT ROLLED TYPE MEETING ASTM A36. SECTION 04200 1. 2. 3. 4. 5. 8. 9. 10. 11. 12. 13. 14. 15. INSTALL MASONRY UNITS AS INDICATED ON THE DOCUMENTS. THESE UNITS SHALL INCLUDE, BUT NOT BE LIMITED TO REGULAR CONCRETE BLOCK. PROVIDE COLD WEATHER PROTECTION WHEN WEATHER CONDITIONS DICTATE. MASONRY UNITS SHALL BE REINFORCED WITH TRUSS TYPE REINFORCING PER ASTM A153. CONTRACTOR IS RESPONSIBLE TO INSTALL ALL NECESSARY ITEMS INCLUDING STEEL LINTELS, ANCHORS, REINFORCING, ETC., AND ALL OTHER ITEMS NECESSARY FOR A COMPLETE INSTALLATION. MASONRY SHALL BE MINIMUM 2000 PSI - NORMAL WEIGHT AND MEET ASTM C 90. MORTAR SHALL BE TYPE "S" AND SHALL MEET ASTM. C270. COLOR AS SCHEDULED ON EXTERIOR FINISH SCHEDULE. FLASHING, WEEP HOLES, AND VENTS: GENERAL: INSTALL EMBEDDED FLASHING AND WEEP HOLES IN MASONRY AT SHELF ANGLES, LINTELS, LEDGES, OTHER OBSTRUCTIONS TO DOWNWARD FLOW OF WATER IN WALL, AND WHERE INDICATED. EXTEND FLASHING 4 INCHES AT ENDS AND TURN FLASHING UP NOT LESS THAN 2 INCHES TO FORM A PAN. INSTALL METAL DRIP EDGES BENEATH FLASHING AT EXTERIOR FACE OF WALL STOP FLASHING 1/2 INCH BACK FROM OUTSIDE FACE OF WALL AND ADHERE FLASHING TO TOP OF METAL DRIP EDGE. INSTALL METAL FLASHING TERMINATION BENEATH FLASHING AT EXTERIOR FACE OF WALL. STOP FLASHING 1/2 INCH BACK FROM OUTSIDE FACE OF WALL AND ADHERE FLASHING TO TOP OF METAL FLASHING TERMINATION. PROVIDE SINGLE WYTHE CONCRETE MASONRY UNIT DRAINAGE SYSTEM USING BLOK-FLASH, MANUFACTURED BY MORTAR NET USA. DRAINAGE SYSTEM INCLUDES PAN, INTEGRATED WEB SPACER/BRIDGE AND DRAINAGE MAT. FOLLOW MANUFACTURER'S SPECIFICATIONS FOR HANDLING AND INSTALLATION. FOR VERTICAL AND HORIZONTAL REINFORCING REF TO STRUCTURAL DRAWINGS. COAT EXTERIOR BLOCK WITH CLEAR PROSOCO SILOXANE WB MASONRY SEALER IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS, COVERAGE RATES AND SPECIFICATIONS. METALS SECTION 05120 STRUCTURAL STEEL REFER TO STRUCTURAL DRAWINGS. SECTION 05400 COLD FORMED METALS REFER TO STRUCTURAL DRAWINGS SECTION 05500 METAL FABRICATIONS PROVIDE AND INSTALL ALL ITEMS MADE FROM IRON AND STEEL SHAPES, PLATES, BARS, STRIPS, TUBES, PIPES AND CASTINGS WHICH ARE NOT A PART OF THE STRUCTURAL STEEL OR OTHER METAL SYSTEMS SPECIFIED ELSEWHERE. LOOSE STEEL LINTELS. 1. 2.a. LOOSE BEARING AND LEVELING PLATES. THESE SHALL INCLUDE, BUT NOT NECESSARILY BE LIMITED TO THE FOLLOWING: 2.b. MISCELLANEOUS FRAMING AND SUPPORTS. 2. 2.c. STEEL BOLLARDS (SCHEDULE 40) ALL FERROUS METALS SHALL BE SHOP PRIMED AND FIELD TOUCHED UP. 2.d. 3. PROVIDE A ZINC COATING FOR ITEMS EXPOSED TO THE EXTERIOR. DOWNSPOUT GUARDS 4. ALSO, PROVIDE ZINC COATING FOR ANY STEEL INSIDE EXTERIOR MASONRY WALLS. 2.e. 5. ROUGH CARPENTRY PROVIDE AND INSTALL ALL WORK NECESSARY FOR ROUGH CARPENTRY INCLUDING: WOOD GROUNDS, NAILERS, AND BLOCKING. WOOD FURRING & FRAMING. ROOF PLATES AND CANTS. ALL WOOD BLOCKING, NAILERS, PLATES AND PLYWOOD SHALL BE EXTERIOR GRADE, CHEMICALLY FIRE RETARDANT TREATED. ALL WOOD IN CONTACT WITH MASONRY OR CONCRETE SHALL COMPLY WITH APPLICABLE STANDARDS FOR PRESERVATIVE TREATMENT LUMBER. (LUMBER AWPA C2). CARPENTRY SECTION 06100 1. 2. 3. SECTION 06200 FINISH CARPENTRY PROVIDE ALL LABOR, MATERIALS, SERVICE AND EQUIPMENT NECESSARY FOR ALL FINISH CARPENTRY WORK, INCLUDING, BUT NOT LIMITED TO: INSTALLATION OF DOORS AND HARDWARE. THERMAL & MOISTURE PROTECTION 2. INSTALLATION SHALL BE PER MANUFACTURER'S INSTRUCTIONS. SECTION 07200 3. Florida Business License: AA26001620 CONSULTANT: SEAL: DONALD FRANCIS BARRY, AR94443 PERMIT Dept Mgr Approval 0 REV THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION PURPOSES UNTIL THE SEAL AND SIGNATURE OF THE RESPONSIBLE REGISTRANT APPEARS ON THE DRAWING, AND PROPER PERMIT FORMS AND RELATED FEES ARE TRANSMITTED BY THE OWNER, OWNER'S AGENT OR CONTRACTOR TO THE AUTHORITY HAVING JURISDICTION. 9/28/2012 A.RICCUTTI B.COLBURN 9/20/2012 PALMETTO CAPITAL GROUP 220 East High Street Charlottesville, VA 22903 Office: (434) 295-7131 Contact: Austin Cox DOLLAR GENERAL US HWY 27 & SANDMINE ROAD DAVENPORT, FLORIDA DO NOT SCALE DRAWING JCDT.12.0279
© Copyright 2024