ALTAMONT - VA HOMELESS SHELTER SILVESTRI ARCHITECTS, P.C. A.F.F ACT. A.C. ALT. ALUM. APPROX. ARCH. AUTO CIVIL: 1321 MILLERSPORT HIGHWAY, SUITE 101 AMHERST, NY 14221 SP-101 SITE PLAN ARCHITECTURAL: A-101 A-102 A-103 A-104 A-201 A-301 A-401 A-601 STRUCTURAL ENGINEER: PETRILLI ENGINEERING 429 FRANKLIN ST. BUFFALO, NY 14202 CONSTRUCTION MANAGMENT: SAVARINO COMPANIES THIRD FLOOR PLAN & PARTITION TYPES REFLECTED CEILING PLAN ATTIC PLAN ROOF FRAMING & ROOF PLAN EXTERIOR ELEVATIONS BUILDING SECTIONS ENLARGED PLANS & DETAILS ROOM FINISHES, WINDOW & DOOR SCHEDULE ELECTRICAL E-101 THIRD FLOOR ELECTRICAL PLAN 26 MISSISSIPPI ST. BUFFALO, NY 14203 DRAWING AREA LOGIC 3 4 5 A-101 6 E 2 E 1 SHEET IDENTIFICATION LOGIC D D TITLE BLOCK B C4 B B3 A1 A4 A3 1 2 A A C C D3 3 4 5 6 DISCIPLINE DESIGNATOR SHEET TYPE DESIGNATOR SEQUENCE NUMBER DISCIPLINE DESIGNATOR G C L S A AI F P M E GENERAL CIVIL LANDSCAPE STRUCTURAL ARCHITECTURAL ARCH. INTERIORS FIRE PROTECTION PLUMBING MECHANICAL ELECTRICAL SHEET TYPE DESIGNATOR 0 1 2 3 4 5 6 7 GENERAL PLANS ELEVATIONS SECTIONS LARGE SCALE VIEWS DETAILS SCHEDULES & DIAGRAMS REFLECTED CEILING PLAN ABOVE FINISH FLOOR ACOUSTICAL TILE AIR CONDITION ALTERNATE ALUMINUM APPROXIMATE ARCHITECTURAL AUTOMATIC BM BRG B.M. BLK BLKG BD BOT BRK B.E.J. B.C. BLDG BUR BEAM BEARING BENCH MARK BLOCK BLOCKING BOARD BOTTOMS BRICK BRICK EXPANSION JOINT BRICK COURSE BUILDING BUILT-UP ROOFING CLG. CAB CPT C.W. C.B. CEM CT CHBD CLR COL CONC. CMU CONT. CONTR CJT C.G. CRS CEILING CABINET CARPET CASEWORK CATCH BASIN CEMENT CERAMIC TILE CHALK BOARD CLEAR COLUMN CONCRETE CONCRETE MASONRY UNIT CONTINUOUS CONTRACTOR CONTROL JOINT CORNER GUARD COURSE DET. DIA. DIM. DISP. DN DS DWG D.F. DIFF. DETAIL DIAMETER DIMENSION DISPENSER DOWN DOWNSPOUT DRAWING DRINKING FOUNTAIN DIFFUSER EA EIFS ELEC EPNL EL ELEV. EQ EX. F. EXIST. EXP. JT. EACH EXTERIOR INSULATION & FINISH SYSTEM ELECTRICAL ELECTRIC PANEL ELEVATOR ELEVATION EQUAL EXHAUST FAN EXISTING EXPANSION JOINT FB FIN F.A. FEC FHC F.P. FL. F.D. FT F.W.C. FTG FDTN FUR FACE BRICK FINISH (ED) FIRE ALARM FIRE EXTINGUISHER CABINET FIRE HOSE CABINET FIRE PROOFING FLOOR FLOOR DRAIN FOOT FACE WALL COVERING FOOTING FOUNDATION FURRING GAL GA G.C. GL. G.B. G.W.B. GYP. GALLON GAGE GENERAL CONTRACTOR GLASS GRAB BAR GYPSUM WALL BOARD GYPSUM HDW HD. WD. HVAC HT HC HM HORIZ HB H.W. HARDWARE HARDWOOD HEATING, VENTILATING, & AIR CONDITIONING HEIGHT HOLLOW CORE HOLLOW METAL HORIZONTAL HOSE BIB HOT WATER INSUL INS. GL INV INSULATE (D) (ION) INSULATED GLASS INVERT JAN JT JANITOR JOINT KIT KO KITCHEN KNOCK OUT LAM LAV LH LGT LT L.F. LTL LL LLH LLV L.M.F. LVR L.P. LAMINATED LAVATORY LEFT HAND LENGTH LIGHT LINEAR FEET LINTEL LIVE LOAD LONG LEG HORIZONTAL LONG LEG VERTICAL LIGHT GAUGE METAL FRAMING LOUVER LOW POINT MACH M.H. MFR MAS M.O. MATL MAX MECH MEMB MET M.T.P. MIN MISC. MULL MACHINE MANHOLE MANUFACTURE MASONRY MASONRY OPENING MATERIAL MAXIMUM MECHANICAL MEMBRANE METAL METAL TOILET PARTITION MINIMUM MISCELLANEOUS MULLION N.I.C. N.T.S. NOM NO. NOT IN CONTRACT NOT TO SCALE NOMINAL NUMBER O.C. OPNG OPP OPPH OH ON CENTER OPENING OPPOSITE OPPOSITE HAND OVERHEAD PMBC PNT PNL P.T.D. P.T.R. PVMT PG. BD PLAS. P. LAM PL POL PWD PT PSI PSF P.P. PRE. FAB. PREF PROJ. PL PRENGINEERED METAL BUILDING CONTRACTOR PAINT (ED) PANEL PAPER TOWEL DISPENSER PAPER TOWEL RECEPTER PAVEMENT PEG BOARD PLASTER PLASTIC LAMINATE PLATE POLISHED PLYWOOD POINT POUNDS PER SQ. INCH POUNDS PER SQ. FOOT POWER PANEL PREFABRICATED PREFINISHED PROJECTION PROPERTY LINE QT QUARRY TILE RAD R.W.L. RECPT. REC. REFR REG REINF. REQ'D RES R.C.P. RET RA RVS REV RH ROW R R.D. RFG RM RND RADIUS RAIN WATER LEADER RECEPTACLE, ELECTRIC RECESS REFRIGERATOR REGISTER REINFORCE (D) (ING) REQUIRED RECESS (ED) REFLECTED CEILING PLAN RETURN RETURN AIR REVERSE REVISION RIGHT HAND RIGHT OF WAY RISER ROOF DRAIN ROOFING ROOM ROUND SDL STG SHTH SHT SHR SIM SPKR SPEC SQ. SST SP STD SD S.G.T. STRUCT. SUSP. SW. SWBD SV SADDLE SEATING SHEATHING SHEET SHOWER SIMILAR SPEAKER SPECIFICATIONS SQUARE STAINLESS STEEL STAND PIPE STANDARD STORM DRAIN STRUCTURAL GLAZED TILE STRUCTURAL SUSPENDED SWITCH SWITCH BOARD SHEET VINYL T.B. TEL TEMP TEX THK THR TP T/O TB TYP TACKBOARD TELEPHONE TEMPERATURE TEXTURE THICK (NESS) THRESHOLD TOILET PAPER HOLDER TOP OF TOWEL BAR TYPICAL U.C.L. U.C. UR UNDER CABINET LIGHT UNDERCUT URINAL V.T.R. VENT VERT VEST V.C.T. V.I.F. V.W.C. VENT THRU ROOF VENTILATOR VERTICAL VESTIBULE VINYL COMPOSITE TILE VERIFY IN FIELD VINYL WALL COVERING DIRECTION OF SECTION DETAIL / SECTION NO. 1 A-000 1 SHEET NUMBER 4 SHEET NUMBER WAINSCOT WEATHER STRIP WEIGHT WELDED WIRE FABRIC WHEELCHAIR DRINKING FOUNTAIN WITH WITHOUT WOOD 1 DIRECTION OF VIEW ELEVATION NO. 3 OFFICE PHONE ROOM NAME ROOM NUMBER 000 DIRECTION OF SLOPE WINDOW TYPE WALL MOUNTED SINK 2 A-000 SLOPE 1 PARTITION TYPE V-1 VIEW WINDOW TYPE DOOR NUMBER 01 FIRE EXTINGUISHER IN RECESSED CABINET NEW DOOR FE FIRE EXTINGUISHER ON MOUNTING BRACKET EXISTING DOOR DEMO DOOR DATUM LINE ELEVATION MATERIAL SYMBOLS CONCRETE BLOCK WALL EARTH RIGID INSULATION CONCRETE BLOCK (SECTION) GYPSUM BOARD BRICK (SECTION) METAL BATT INSULATION WOOD POURED CONCRETE PLYWOOD COMPACT POROUS GRAVEL NEW PARTITION GLASS/MIRROR (ELEVATION) EXISTING PARTITION CONTINUOUS WOOD STUD ACOUSTICAL TILE DEMO PARTITION BUILDING DATA OCCUPANCY CLASSIFICATION: R-2 - BOARDING HOUSE CONSTRUCTION TYPE: 3B GROSS S.F. (WORK AREA): 1562 S.F. NET S.F. (WORK AREA): 1484 S.F. WSCT WS WT WWF W.C.D.F. W/ W/O WD WINDOW UNIT SPRINKLER REQ'D?: EXISTING TO BE MODIFIED OCCUPANCY LOAD: 8 PEOPLE INTERIORS: DRAFTER: TITLE SHEET JOB CAPTAIN: DRAFTING SYMBOLS PROJ. ARCHITECT: ABBREVIATIONS SA PROJECT TEAM: PRINCIPAL: P.Silvestri SHEET INDEX S.A. PROJECT # 10030 DATE: 10-04-2011 ARCHITECT: 30 WYOMING AVE. BUFFALO, NY S.A. PROJECT # 10030 DATE: 10-04-2011 ALTAMONT - VA HOMELESS SHELTER 30 WYOMING AVE. BUFFALO, NY 1 3 2 4 5 6 E E NOTICE This document, the property of, prepared and issued by the architect, is submitted for the specific project namely and the recipient by accepting this document assumes custody and agrees that this document will not be copied or reproduced in part or in whole, and any special features peculiar to this design shall not be incorporated in any other project, unless prior agreement has been obtained in writing.These documents will be returned immediately upon completion of the project or upon the request of the architect. This document is the exclusive property of the architect, no rights to ownership are transferable, or shall be lost by the filing of this document with any and all public authorities for the purpose of compliance with Codes and or Ordinances, i.e. Building Permit, etc. Savarino Companies DRIVE EXIST. BLACKTOP OVER CONCRETE 26 Mississippi St Buffalo, NY 14203 BRICK GARAGE NO EAVES D D 118'-0" ISSUE: C +/- 7'-5" V.I.F. EXACT BRICK HOUSE NO. 30 30 Wyoming Ave Buffalo, NY MOSELLE STREET (60' WIDE) 47'-0" 32'-5" 47'-0" EXIST. CONC. PAD SA PROJECT TEAM: PRINCIPAL P.Silvestri PROJ. ARCH. DRAFTER M. Merkwa JOB CAPT. +/- 12'-3" V.I.F. EXACT 5'-083" C WYOMING STREET (60' WIDE) EXIST. 8" WIDE CONCRETE RETAINING WALL 68'-10" 9'-658" 18'-314" Altamont VA Homeless Shelter INTERIORS A. Fornataro SEAL: NEW CONC. SIDEWALK TO REAR EGRESS DOOR; V.I.F. EXIST. CONDITIONS & EXACT EXTENT OF NEW WALK EXIST. GAURD RAIL EXIST. GROTTO TITLE: SITE PLAN EXISTING PARKING AREA SITE PLAN SCALE: 1/8" =1'-0" A A B2 B B EXISTING BLACK TOP DRIVE SA JOB #: 10030 DRAWING #: A5 1 2 3 4 5 TYPICAL SIDEWALK DETAIL SCALE: NTS 6 DATE: 10-04-11 SP-101 1 2 3 4 5 6 GENERAL NOTES: NOTICE 1. FIRE PROTECTION SYSTEMS ARE EXISTING. CONTRACTOR TO DROP NEW HEADS INTO SPACES AND INSTALL ADDITIONAL FIRE PULL STATIONS AND ANNUNCIATORS AS REQ'D. PER NFPA 70 2. CONTRACTOR SHALL PROVIDE AND INSTALL (1) ADDITIONAL REQ'D. PORTABLE FIRE EXTINGUISHER, TYPE 10B, PER NFPA 10, AND AS DIRECTED BY THE LOCAL FIRE DEPARTMENT THROUGHOUT BUILDING. 66'-6" EXIST 5'-4" 8'-1" 6'-358" 4'-8" A1 4'-8" D3 A-301 4'-421" 1 1 1 1 3 1 1 4'-0" 4'-0" 2 3 4. CONTRACTOR IS TO VERIFY ALL DIMENSIONS PRIOR TO THE START OF CONSTRUCTION AND NOTIFY ARCHITECT OF ANY DIFFERENCES PRIOR TO BEGINNING OF CONSTRUCTION. 1 1 1 2 7. CONTRACTOR SHALL REVIEW AND SUBMIT SHOP DRAWINGS SUFFICIENTLY IN ADVANCE OF THE WORK TO ALLOW PROPER TIME FOR REVIEW. MATERIALS SHALL NOT BE FABRICATED OR DELIVERED TO THE SITE BEFORE THE SHOP DRAWINGS HAVE BEEN REVIEWED AND APPROVED BY THE OWNER'S REPRESENTATIVE. 2 9'-6" 3 16'-058" 8'-8" 307 306 12'-434" 1 CO 1 3 2 2 1 1 309 9'-7" 1 3 2 6'-0" EXIST. DOOR TO BE REMOVED 8'-6" 9'-1034" 5'-2" 1 1 1 C 1 2'-4" 7'-334" 3'-3" 2 1 2'-4" B6 2'-5" A-401 9'-021" 5'-6" ALL FURNITURE PROVIDED & INSTALLED BY OWNER EXIST. 2-1/2" VENT 1 4'-421" 1 4'-0" 4'-1" 4'-1" 1 4'-10" 4'-1" 4'-0" 4'-0" 1 EXIST. SPRINKLER DROP TO 2ND FLR. 8'-4" EXIST. 2'-4" 9'-021" 13'-4" 12. MECHANICAL, ELECTRICAL, AND PLUMBING, ARE SCHEMATIC IN NATURE. THEREFORE, IT IS THE GENERAL CONTRACTOR'S RESPONSIBILITY TO COORDINATE THE ROUTING OF THESE TRADES, AS WELL AS, THE OWNER'S WORK TO ASSURE THAT THESE SYSTEMS DO NOT CONFLICT WITH THE ARCHITECTURAL AND STRUCTURAL ELEMENTS OF THE BUILDING. IF THE GENERAL CONTRACTOR ROUTE THESE ITEMS TO AVOID A CONFLICT, THEN THEY SHALL NOTIFY THE ARCHITECT PRIOR TO STARTING ANY RELATED WORK. 1 4'-321" 5'-521" D 30 Wyoming Ave Buffalo, NY ISSUE: 5'-221" SA PROJECT TEAM: PRINCIPAL P.Silvestri PROJ. ARCH. DRAFTER JOB CAPT. M. Merkwa INTERIORS A. Fornataro SEAL: 13. CONTRACTOR TO PROTECT ALL NEW WORK DURING CONSTRUCTION AND REPLACE DAMAGED MATERIAL IN KIND. C1 Altamont VA Homeless Shelter 11. THE LOCATION OF ALL ITEMS WHEN ON THE DRAWINGS OR CALLED FOR IN THE SPECIFICATIONS THAT ARE NOT DEFINITELY FIXED BY DIMENSIONS ARE DIAGRAMMATIC. THE EXACT LOCATIONS NECESSARY TO SECURE THE BEST CONDITIONS AND RESULTS MUST BE DETERMINED AT THE PROJECT AND SHALL HAVE THE APPROVAL OF THE OWNER'S REPRESENTATIVE BEFORE BEING INSTALLED. DO NOT SCALE DRAWINGS. THE CONTRACTOR SHALL FURNISH AND INSTALL, WITHOUT ADDITIONAL REMUNERATION, ANY COMPONENT NECESSARY TO COMPLETE THE SYSTEMS IN ACCORDANCE WITH THE BEST PRACTICE OF THE TRADE. 1 4'-1" 1 10. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY AND ALL DISCREPANCIES BETWEEN FIELD CONDITIONS AND THE CONTRACT DOCUMENTS BEFORE PROCEEDING WITH THAT PORTION OF THE WORK. FAILURE TO NOTIFY THE ARCHITECT WILL NOT RELIEVE THE CONTRACTOR OF RESPONSIBILITY TO COMPLY WITH THE DOCUMENTS. THE CONTRACTOR SHALL CORRECT ANY AND ALL WORK ARISING FROM SUCH FAILURE AND COORDINATE DISCREPANCIES TO THE SATISFACTION OF THE ARCHITECT WITHOUT ADDITIONAL COST TO THE OWNER. RECOMMENDED BY MANUFACTURER. 9'-641" 10'-221" EXIST. F.E. 310 8'-6" 302 EXIST. DOOR TO REMIAN CO 3 311 301 2 6'-3" 2 3 1'-5" A-101 2 2'-921" 3 2 3 A4 3 2 9. DO NOT SCALE DRAWINGS, THE DIMENSIONS SHOWN ON THE PLANS MAY VARY FROM THE ACTUAL DIMENSIONS IN THE FIELD. IT IS, THEREFORE, IMPERATIVE THAT THE CONTRACTOR, PRIOR TO COMMENCEMENT OF WORK, TAKE EXACT MEASUREMENTS TO VERIFY ALL DIMENSIONS SHOWN ON THE PLANS AND SHOP DRAWINGS. ALL WORKING DRAWINGS PREPARED BY THE CONTRACTOR SHALL INCLUDE A STATEMENT CERTIFYING THAT THOSE DRAWINGS HAVE BEEN PREPARED IN ACCORDANCE WITH THE FIELD MEASURED DIMENSIONS. 315 C UP ATTIC HATCH 2 NEW F.E. 5'-4" 2 3'-11" EXIST. 303 3 3308 2 10'-6" EXIST. 11'-1" EXIST. 31'-6" EXIST. D 3 9'-834" 305 26 Mississippi St Buffalo, NY 14203 8. ALL SUBSTITUTE MANUFACTURERS, EQUIPMENT, MATERIALS AND PRODUCTS SHALL BE APPROVED BY THE OWNERS REPRESENTATIVE. THE CONTRACTORS IS RESPONSIBLE FOR ALL ASSOCIATED COSTS TO ANY AND ALL BUILDING COMPONENTS THAT ARE AFFECTED BY THE SUBSTITUTIONS. ADDITIONAL COSTS INCLUDE ANY REDESIGN THAT IS REQUIRED DUE TO THE SUBSTATION. 1 5'-2"304 Savarino Companies 6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VISITING THE SITE TO VERIFY EXISTING CONDITIONS PRIOR TO SUBMITTING HER/HIS BID. 1 1 2 2 1 EXIST. CHIMNEY 1 1 5. BEFORE SUBMITTING BID, EXAMINE ALL DRAWINGS RELATED TO THE WORK, BECOME FULLY INFORMED AS TO THE EXTEND AND CHARACTER OF THE WORK OF ALL TRADES AND ITS RELATION TO THE WORK UNDER THE CONTRACT. NO CONSIDERATIONS WILL BE GIVEN FOR ALLEGED MISUNDERSTANDING OF THE MATERIALS TO BE FURNISHED OR THE WORK TO BE DONE. 3 3 6'-5" 3'-3" 2'-4" 4'-0" 2'-4" 3. ALL DIMENSIONS ARE FROM FACE OF STUD TO STUD OR EXISTING CONSTRUCTION. A-301 4'-0" E A-301 6'-334" E 8'-314" EXIST 4'-0" 3'-3" 9'-021" 8'-921" 3 B17'-34" This document, the property of, prepared and issued by the architect, is submitted for the specific project namely and the recipient by accepting this document assumes custody and agrees that this document will not be copied or reproduced in part or in whole, and any special features peculiar to this design shall not be incorporated in any other project, unless prior agreement has been obtained in writing.These documents will be returned immediately upon completion of the project or upon the request of the architect. This document is the exclusive property of the architect, no rights to ownership are transferable, or shall be lost by the filing of this document with any and all public authorities for the purpose of compliance with Codes and or Ordinances, i.e. Building Permit, etc. 14. ALL GYPSUM WALL BOARD TO BE TAPED AND SANDED AT INTERSECTION OF CONSTRUCTION (NO. "J" MOLD) THIRD FLOOR PLAN SCALE: 1/4" = 1'-0" 15. PROVIDE CORNER BEAD AT ALL EXPOSED GYPSUM WALL BOARD CORNERS. 16. DOOR OPENINGS SHALL BE LOCATED 4" FROM THE NEAREST FACE OF WALL IN MASONRY WALL CONSTRUCTION, UNLESS OTHERWISE NOTED. TITLE: 17. CONTRACTOR SHALL PROVIDE ALL MATERIALS, FABRICATION, LABOR AND SUPERVISION, ERECTION EQUIPMENT AND APPLIANCES REQUIRED TO INSTALL ALL EQUIPMENT SHOWN ON DRAWINGS AS INDICATED IN THE SPECIFICATIONS. 18. THE TERM "PROVIDE" SHALL MEAN "FURNISH AND INSTALL, INCLUDING ALL LABOR, EQUIPMENT, MATERIALS AND PRODUCTS," UNLESS OTHERWISE NOTED. THIRD FLOOR PLAN B B 19. CONTRACTOR SHALL COORDINATE HER/HIS WORK WITH THE OWNER SO THAT THERE IS NO INTERFERENCE WITH OWNER'S PERSONAL OR WORK SCHEDULE. 20. ALL WORK SHALL COMPLY WITH RULES AND REGULATIONS OF ALL GOVERNMENTAL AGENCIES HAVING JURISDICTION. 21. THE CONTRACTOR SHALL BE RESPONSIBLE FOR INITIATING, MAINTAINING AND SUPERVISING ALL SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE PERFORMANCE OF THE CONTRACT. TOTAL R-38 BATT INSUL. GWB @7'-6" WHERE SPECIFIED ACT @7'-6" WHERE SPECIFIED 421" R-19 SOUND BATT INSUL. 2x4 WOOD STUDS @16" OC. ELEVATED FLOOR +0'-10" EXIST. WOOD FLOOR 1 2" GWB (INTERIOR ONLY) TO 6" ABV. FINISHED CLG. EA. SIDE; USE MOISTURE RESISTANT GWB IN BATHROOM GWB (INTERIOR ONLY) TO 6" ABV. FINISHED CLG. EA. SIDE AS SHOWN; USE MOISTURE RESISTANCE GWB IN BATHROOM 2x4 WOOD STUDS @16" OC. EXISTING 2x4 WOOD STUDS @16" OC. EXIST. WOOD FLOOR EXIST. WOOD FLOOR 3 4" 2 STANDARD 2x4 WALL PARTITION 26. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SECURING AND PAYING FOR ALL PERMITS AND APPROVALS NECESSARY FOR THE COMPLETION OF THE PROJECT. 28. THE CONTRACTOR SHALL COORDINATE ALL FINISHES AND COLOR SELECTIONS WITH THE OWNER. DBL. 2x10 3 EXISTING 2x4 WALL PARTITION A4 SCALE: 1" = 1'-0" 2 PLYWD TREAD 27. ALL NEW MATERIALS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURERS LATEST WRITTEN INSTRUCTIONS AND SPECIFICATIONS. PARTITION TYPES 1 25. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO INSURE AGAINST DAMAGE TO EXISTING WORK TO REMAIN IN PLACE. ANY DAMAGE TO SUCH WORK SHALL BE REPAIRED OR REPLACED TO THE SATISFACTION OF THE OWNER AT NO ADDITIONAL COST. 1'-0" 2x10 @16" OC STANDARD KNEE WALL PARTITION T&G WOOD SUBFLOOR WOOD NOSING FINISHED FLOOR +0'-0" 1 24. CONTRACTOR SHALL FURNISH ALL SCAFFOLDING, HOISTING EQUIPMENT AND ANY OTHER EQUIPMENT THAT MAY BE REQUIRED TO PERFORM THE WORK INDICATED IN A SAFE AND ORDERLY MANNER. 5" A GWB (INTERIOR ONLY) TO 6" ABV. FINISHED CLG. USE MOISTURE RESISTANT GWB IN BATHROOM ACT @7'-6" R-19 SOUND BATT INSUL. 1 2" 1 2" 3 4" 10" MIN. R-19 BATT INSUL. 23. CONTRACTOR SHALL REMOVE AND PROPERLY DISPOSE OF ALL DEBRIS FROM SITE AND LEAVE THE WORK AREA BROOM CLEAN ON A DAILY BASIS AND PROVIDE DUMPSTER SERVICE. PLACE DUMPSTER AS DIRECTED BY THE "OWNER'S REPRESENTATIVE" 6" 6" 421" GWB TO TEMINATE AT SLOPED CLG. ABV. 4" TOP PLATE; BRACE TO ADJACENT EXIST. 2x8 RAFTERS AS REQ'D. EXIST. 2x8 6" EXIST. 2x8 TOP PLATE; BRACE TO ADJACENT EXIST. 2x8 RAFTERS AS REQ'D. (HGT. VARIES) 22. SAFE WORKING CONDITIONS ARE ALL SAFETY REQUIREMENTS ESTABLISHED BY JURISDICTIONAL AGENCIES AND/OR THE OWNER SHALL BE OBSERVED. WHERE CONFLICTS EXIST, THE MORE STRINGENT REQUIREMENTS SHALL APPLY. CARE MUST BE EXERCISED TO AVOID ENDANGERING PERSONNEL OR THE STRUCTURE. B.O. CHORD +8'-4" 3 A B.O. CHORD +8'-4" TOTAL R-38 BATT INSUL. 4 DBL 2x6 RIPPED TO SIZE EXIST. WOOD SUBFLOOR 29. ALL FASTENERS INTO PRESSURE TREATED LUMBER ARE TO BE HOT DIPPED GALVANIZED OR STAINLESS STEEL AS RECOMMENDED BY MANUFACTURER. 30. ALL RAFTERS & JOISTS DFL - NO. 2 OR BETTER STAIR DETAIL SCALE: 1-1/2" = 1'-0" 5 6 SA JOB #: 10030 DRAWING #: DATE: 10-04-11 A-101 2 3 4 5 NOTES 1. 2. E 3. FIRE PROTECTION CONTRACTOR TO PROVIDE EMERGENCY LIGHTING, CO DETECTION & SMOKE DETECTION AS REQUIRED BY LOCAL CODE AND IHG LIFE SAFETY STANDARDS. ELECTRICAL CONTRACTOR TO RELOCATE ALL EXISTING EXIT AND EMERGENCY SIGNAGE. ALL LIGHTING ON GWB CEILINGS TO BE SURFACE MOUNTED. ALL LIGHTING ON ACT CEILINGS TO BE LAY-IN TYPE. 6 REFLECTED CEILING PLAN LEGEND 9'-0" A HEIGHT ABOVE FINISHED FLOOR CEILING TYPE CEILING TYPE "A" - GYPSUM BOARD PAINTED CEILING TYPE "B" - 2X2 SUSPENDED ACOUSTICAL TILE CEILING TYPE "C" - 2X4 SUSPENDED ACOUSTICAL TILE CEILING TYPE "D" EXPOSED - PAINTED 4. FIRE PROTECTION CONTRACTOR TO INSTALL NEW SPRINKLER HEADS AND FIRE PULL STATIONS ONTO EXIST. SYSTEM AS REQ'D. PER NFPA. NOTICE E 1 2X2 DIFFUSER 2X2 RETURN Savarino Companies EXIT SIGN 2X4 FLUORESCENT LIGHT FIXTURE 1 2" GWB ON CHANNELS APPLIED TO EXIST. RAFTERS 7 8" This document, the property of, prepared and issued by the architect, is submitted for the specific project namely and the recipient by accepting this document assumes custody and agrees that this document will not be copied or reproduced in part or in whole, and any special features peculiar to this design shall not be incorporated in any other project, unless prior agreement has been obtained in writing.These documents will be returned immediately upon completion of the project or upon the request of the architect. This document is the exclusive property of the architect, no rights to ownership are transferable, or shall be lost by the filing of this document with any and all public authorities for the purpose of compliance with Codes and or Ordinances, i.e. Building Permit, etc. EMERGENCY LIGHT 26 Mississippi St Buffalo, NY 14203 7'-0" HEAD ROOM MIN. 7'-0" HEAD ROOM MIN. 7'-6" C 7'-6" 7'-6" C C 7'-6" 7'-6" C C C E D D 7'-6" 7'-0" HEAD ROOM MIN. 7'-0" HEAD ROOM MIN. 7'-6" SD C C WALL MOUNTED FLOUR. FIXTURE CENTERED OVER VANITY @7'-0" AFF. SOFFIT @7'-6" AFF. CO SD 7'-6" 7'-6" CO 7'-6" 7'-6" C 7'-6" C C 7'-6" 30 Wyoming Ave Buffalo, NY C C 7'-0" HEAD ROOM MIN. ISSUE: 7'-0" 1 2" 7 8" A NEW SURFACE MOUNTED FIXTURE GWB ON CHANNELS APPLIED TO EXIST. RAFTERS C C RELOCATE EXIST. EMERGENCY LIGHT/EXIT SIGNAGE E-Z HATCH ATTIC ACCESS SCUTTLE DOOR R-42+ (22"x30") OR EQUAL. C1 Altamont VA Homeless Shelter SA PROJECT TEAM: PRINCIPAL P.Silvestri PROJ. ARCH. DRAFTER JOB CAPT. RELOCATE EXIST. EMERGENCY LIGHT/EXIT SIGNAGE M. Merkwa INTERIORS A. Fornataro SEAL: REFLECTED CEILING PLAN SCALE: 1/4" = 1'-0" TITLE: B B A A REFLECTED CEILING PLAN SA JOB #: 10030 DRAWING #: 1 2 3 4 5 6 DATE: 10-04-11 A-102 1 2 3 4 5 6 1. PROVIDE BATT INSULATION IN ATTIC; ACHIEVE IN ANY COMBINATION (1) CAVITY LAYER BETWEEN JOISTS AND (1) CONTINUOUS LAYER RUN PERPENDICULAR. TOTAL VALUE TO BE R-38 MIN. 2. PROVIDE ADDITIONAL CEILING JOISTS AS REQ'D. 3. PROVIDE PLYWD. PLATFORM FOR NEW 80K BTU, GAS-FIRED FORCED AIR FURNACE. CONTRACTOR TO ENSURE MIN. MAINTENANCE AND OPERATION CLEARANCE AROUND FURNACE. NOTICE E E NOTES This document, the property of, prepared and issued by the architect, is submitted for the specific project namely and the recipient by accepting this document assumes custody and agrees that this document will not be copied or reproduced in part or in whole, and any special features peculiar to this design shall not be incorporated in any other project, unless prior agreement has been obtained in writing.These documents will be returned immediately upon completion of the project or upon the request of the architect. This document is the exclusive property of the architect, no rights to ownership are transferable, or shall be lost by the filing of this document with any and all public authorities for the purpose of compliance with Codes and or Ordinances, i.e. Building Permit, etc. Savarino Companies INSTALL NEW 2x8 JOISTS AT NEW & EXIST. DORMERS THAT ARE TO RECEIVE GWB CEILING PLWD CATWALK INSTALL BATT INSULATION (TOTAL R-38) BETWEEN CEILING JOISTS PROVIDE DBL. 1-3/4"x7-1/4" LVL HEADER BETWEEN EXIST. 2x8 CHORDS TO HANG NEW JOISTS 3'-0" 3 4" INSTALL NEW 2x8 JOISTS BETWEEN EXIST. 2x8 CHORDS AS REQ'D. TO SUPPORT CATWALK 26 Mississippi St Buffalo, NY 14203 D 4'-0" D 3'-0" 3'-0" 3'-0" Altamont VA Homeless Shelter CO LOCATE DETECTORS ON RAFTER ADJACENT TO ACCESS HATCH 30 Wyoming Ave Buffalo, NY INSTALL BATT INSULATION (TOTAL R-38) BETWEEN CEILING JOISTS C C ISSUE: SA PROJECT TEAM: PRINCIPAL P.Silvestri PROJ. ARCH. DRAFTER JOB CAPT. M. Merkwa INTERIORS A. Fornataro SEAL: C1 ATTIC PLAN SCALE: 1/4" = 1'-0" TITLE: B B A A ATTIC PLAN SA JOB #: 10030 DRAWING #: 1 2 3 4 5 6 DATE: 10-04-11 A-103 1 3 2 4 5 6 IP JO IS T 8 2x H JO IP T IS P. T. ER IL 2x 8 8 N 2x6 RAFTERS @16" OC A IL ER DBL. 1-3/4"x7-1/4" LVL 2x 8 ER x8 IL ER 2 T. P. P. T. N JO IP IS T 8 2x H 2x 8 N A IL x8 .2 T P. ER 26 Mississippi St Buffalo, NY 14203 I A T P. x .2 8 N P. T. 2x 8 N A IL ER (3)2x8 HEADER 2x6 RAFTERS @16" OC 8 2x IP H JO N Savarino Companies ER IL A R LE (3)2x8 HEADER DBL. 1-3/4"x7-1/4" LVL T IS JO (3)2x8 HEADER IL A N A H IP 2x6 RAFTERS @16" OC DBL. 1-3/4"x7-1/4" LVL 8 2x A N T. P. 2x DBL. 1-3/4"x7-1/4" LVL D P. T. A IL ER N ER IL A DBL. 1-3/4"x7-1/4" LVL T. N H 8 2x (3)2x8 HEADER P. 8 2x 8 2x6 RAFTERS @16" OC (3)2x8 HEADER 2x IS T 2x6 RAFTERS @16" OC P. T. IP IS DBL. 1-3/4"x7-1/4" LVL H JO JO E IP DBL. 1-3/4"x7-1/4" LVL 2x 8 T H DBL. 1-3/4"x7-1/4" LVL E DBL. 1-3/4"x7-1/4" LVL 8 D 2x DBL. 1-3/4"x7-1/4" LVL NOTICE 2x 8 T IS H IP JO IP 8 2x IS T JO This document, the property of, prepared and issued by the architect, is submitted for the specific project namely and the recipient by accepting this document assumes custody and agrees that this document will not be copied or reproduced in part or in whole, and any special features peculiar to this design shall not be incorporated in any other project, unless prior agreement has been obtained in writing.These documents will be returned immediately upon completion of the project or upon the request of the architect. This document is the exclusive property of the architect, no rights to ownership are transferable, or shall be lost by the filing of this document with any and all public authorities for the purpose of compliance with Codes and or Ordinances, i.e. Building Permit, etc. 2x 8 T IS H IP H JO IS T Altamont VA Homeless Shelter 30 Wyoming Ave Buffalo, NY ISSUE: SCALE: 1/4" = 1'-0" C C C1 REPAIR/REPLACE EXIST. EAVE AS REQ'D.; TYP. AT ALL NEW DORMERS EXIST. RAFTERS TO BE CUT @8'-5" AFF.; REFER TO A-301; TYP. AT ALL NEW DORMERS ROOF FRAMING PLAN SA PROJECT TEAM: PRINCIPAL P.Silvestri PROJ. ARCH. DRAFTER JOB CAPT. 9:12 9:12 MATCH EXIST. 9:12 MATCH EXIST. 9:12 MATCH EXIST. 9:12 9:12 DS MATCH EXIST. DS EXIST. CHIMNEY DS 9:12 9:12 MATCH MATCH EXIST. EXIST. DS SEAL: TITLE: 9:12 MATCH MATCH EXIST. EXIST. ROOF FRAMING PLAN & ROOF PLAN DS PROVIDE NEW ALUM. GUTTERS & DOWNSPOUTS AT ENTIRE PERIMETER EXIST. PORCH ROOF BELOW; REMOVE EXIST. ROOFING MATERIALS INCLUDING SHEATHING; REPLACE W/ NEW 21" EXT. GRADE PLYWD SHEATHING, 15# BUILDERS FELT, ICE & WATER SHIELD, AND ARCHITECTURAL ASPHALT SHINGLES B B INTERIORS A. Fornataro PROVIDE NEW ALUM. GUTTERS & DOWNSPOUTS AT ENTIRE PERIMETER MATCH EXIST. EXIST. DORMER DS M. Merkwa EXIST. ROOF NOT IN CONTRACT NEW BOX VENTS; TYP. OF 4 ICE & WATER SHIELD @ ALL VALLEYS; TYP. ALL DORMERS DS 9:12 9:12 MATCH EXIST. MATCH EXIST. A A 9:12 9:12 REMOVE ALL EXIST. FASCIA AND EAVE BOARDS. REPLACE W/ NEW P.T. 1x FASCIA & VENTED ALUM. SOFFIT MATCH EXIST. MATCH EXIST. MATCH EXIST. 9:12 MATCH EXIST. 9:12 LINE OF NEW WALLS DS DS DS A1 1 DS EXIST. ROOF AND DORMERS; REMOVE EXIST. ROOFING MATERIALS INCLUDING SHEATHING; REPLACE W/ NEW 21" EXT. GRADE PLYWD SHEATHING, 15# BUILDERS FELT, ICE & WATER SHIELD, AND ARCHITECTURAL ASPHALT SHINGLES ROOF PLAN SCALE: 1/4" = 1'-0" 2 3 DS EXIST. DORMER SA JOB #: 10030 LINE OF EXIST. MASONRY WALL BELOW ASPHALT SHINGLES TO MATCH EXIST. TYP. ALL NEW DORMERS DRAWING #: 4 5 6 DATE: 10-04-11 A-104 1 2 3 4 5 6 NOTICE PROVIDE NEW FASCIA BD & VENTED ALUM. SOFFITS E E ENTIRE ROOF (INCLUDING EXIST. DORMERS) TO BE STRIPPED DOWN TO EXIST. RAFTERS; PROVIDE NEW 21" PLYWD SHEATHING, ICE & WATER SHIELD, 15# BUILDERS FELT, AND ARCHITECTURAL ASPHALT SHINGLES NEW DORMER, STYLE & MATERIAL TO MATCH EXISTING DORMER. TYP. EXIST. ROOF NOT IN CONTRACT This document, the property of, prepared and issued by the architect, is submitted for the specific project namely and the recipient by accepting this document assumes custody and agrees that this document will not be copied or reproduced in part or in whole, and any special features peculiar to this design shall not be incorporated in any other project, unless prior agreement has been obtained in writing.These documents will be returned immediately upon completion of the project or upon the request of the architect. This document is the exclusive property of the architect, no rights to ownership are transferable, or shall be lost by the filing of this document with any and all public authorities for the purpose of compliance with Codes and or Ordinances, i.e. Building Permit, etc. Savarino Companies ASPHALT SHINGLES TO RUN UP SIDES OF NEW DORMERS PROVIDE NEW FASCIA BD & VENTED ALUM. SOFFITS 26 Mississippi St Buffalo, NY 14203 PROVIDE NEW ALUM. GUTTERS & DOWNSPOUTS AROUND ENTIRE BUILDING EXIST. ROOF NOT IN CONTRACT D D PROVIDE NEW FASCIA BD & VENTED ALUM. SOFFITS PROVIDE NEW ALUM. GUTTERS & DOWNSPOUTS AROUND ENTIRE BUILDING D1 Altamont VA Homeless Shelter 30 Wyoming Ave Buffalo, NY NORTH ELEVATION SCALE: 1/8" = 1'-0" ISSUE: NEW DORMER, STYLE & MATERIAL TO MATCH EXISTING DORMER. TYP. EXISTING CHIMNEY C C ENTIRE ROOF (INCLUDING EXIST. DORMERS) TO BE STRIPPED DOWN TO EXIST. RAFTERS; PROVIDE NEW 21" PLYWD SHEATHING, ICE & WATER SHIELD, 15# BUILDERS FELT, AND ARCHITECTURAL ASPHALT SHINGLES PROVIDE NEW FASCIA BD & VENTED ALUM. SOFFITS SA PROJECT TEAM: PRINCIPAL P.Silvestri PROJ. ARCH. DRAFTER JOB CAPT. EXIST. ROOF NOT IN CONTRACT M. Merkwa INTERIORS A. Fornataro SEAL: ASPHALT SHINGLES TO RUN UP SIDES OF NEW DORMERS PROVIDE NEW FASCIA BD & VENTED ALUM. SOFFITS TITLE: PROVIDE NEW ALUM. GUTTERS & DOWNSPOUTS AROUND ENTIRE BUILDING EXTERIOR ELEVATIONS EXIST. ROOF NOT IN CONTRACT B B PROVIDE NEW FASCIA BD & VENTED ALUM. SOFFITS B1 SOUTH ELEVATION A SCALE: 1/8" = 1'-0" A B1 D1 SA JOB #: A5 KEY PLAN 10030 SCALE: NTS DRAWING #: 1 2 3 4 5 6 DATE: 10-04-11 A-201 1 3 2 4 5 6 NOTICE NEW ARCHITECTURAL ASPHALT SHINGLES NEW 15# BUILDERS FELT NEW 21" EXT. GRADE PLYWD SHEATHING 5'-721" EXIST. ROOF RAFTERS TO REMAIN 3 4" E E PLYWD CATWALK VAPOR BARRIER EXIST. 2x8 CHORD BATT INSUL (R-38) 12 9 VIF Savarino Companies 7 8" HAT CHANNELS @ 8" OC. ON EXIST. RAFTERS ACT HUNG FROM EXIST. 2x8 CHORDS BATT INSUL. (R-19) VAPOR BARRIER 1 2" GWB 7'-6" 8'-5" TOP PLATE @5'-0" AFF. 2x4 STUDS @16" OC W/ 21" GWB EA. SIDE 1 2" 26 Mississippi St Buffalo, NY 14203 EXIST. 2x8 RAFTERS GWB ICE & WATER SHIELD TO 3'-0" FROM INTERIOR FACE OF EXTERIOR WALL 5'-0" 2x4 STUDS @16" OC VAPOR BARRIER BATT INSUL. (R-15) NEW ALUM. DRIP EDGE NEW ALUM. GUTTERS W/ DOWNSPOUTS PROVIDE NEW FASCIA BD. & ALUM. VENTED SOFFIT EXIST. FLOOR JOISTS EXIST. T&G WOOD FLOOR D EXIST. MASONRY WALL D D3 This document, the property of, prepared and issued by the architect, is submitted for the specific project namely and the recipient by accepting this document assumes custody and agrees that this document will not be copied or reproduced in part or in whole, and any special features peculiar to this design shall not be incorporated in any other project, unless prior agreement has been obtained in writing.These documents will be returned immediately upon completion of the project or upon the request of the architect. This document is the exclusive property of the architect, no rights to ownership are transferable, or shall be lost by the filing of this document with any and all public authorities for the purpose of compliance with Codes and or Ordinances, i.e. Building Permit, etc. Altamont VA Homeless Shelter SECTION SCALE: 3/8" = 1'-0" 30 Wyoming Ave Buffalo, NY NEW ARCHITECTURAL ASPHALT SHINGLES NEW 15# BUILDERS FELT NEW 1 2" ISSUE: EXT. GRADE PLYWD SHEATHING 5'-721" EXIST. ROOF RAFTERS TO REMAIN 3 4" PLYWD CATWALK VAPOR BARRIER EXIST. 2x8 CHORD 12 BATT INSUL (R-38) C C 9 VIF 7 8" HAT CHANNELS @ 8" OC. ON EXIST. RAFTERS VAPOR BARRIER 1 2" GWB 8'-5" 7'-585" 1 2" PRINCIPAL P.Silvestri PROJ. ARCH. DRAFTER JOB CAPT. M. Merkwa INTERIORS A. Fornataro BATT INSUL. (R-19) SEAL: TOP PLATE @5'-0" AFF. GWB EXIST. 2x8 RAFTERS 2x4 STUDS @16" OC ICE & WATER SHIELD TO 3'-0" FROM INTERIOR FACE OF EXTERIOR WALL 5'-0" 2x4 STUDS @16" OC W/ 21" GWB EA. SIDE SA PROJECT TEAM: VAPOR BARRIER BATT INSUL. (R-15) NEW ALUM. DRIP EDGE 10" NEW ALUM. GUTTERS W/ DOWNSPOUTS PROVIDE NEW FASCIA BD. & ALUM. VENTED SOFFIT 2x8 FLOOR JOISTS @16" OC EXIST. FLOOR SYSTEM 3 4"x4" EXIST. MASONRY WALL T&G WOOD FLOOR SECTIONS EXIST. RAFTERS TO REMAIN SECTION PROVIDE NEW 21" EXT. GRADE PLYWD SHEATHING; ICE & WATER SHIELD, ARCH. ASPHALT SHINGLES 9 VIF 5'-721" 3 4" PLYWD CATWALK VAPOR BARRIER EXIST. 2x8 CHORD BATT INSUL (R-38) ASPHALT SHINGLES TO MATCH EXIST. 15# BUILDERS FELT 12 B SCALE: 3/8" = 1'-0" B B1 TITLE: 1 2" EXT GRADE PLYWD 2x8 RAFTERS @16" OC 2x8 NAILER 12 9 VIF MATCH EXIST. INSTALL (3)2x8 HEADER SUPPORT FOR EXIST. ROOF; APPLY SLOPEABLE JOIST HANGERS TO NEW HEADER 2x4 SOFFIT FRAMING 2x6 EAVE FRAMING ALUM. DRIP EDGE 1x FASCIA BD. 6" 3 8" EXT. GRADE PLYWD SOFFIT; PAINT TO MATCH 1'-221" VINYL CLAD WOOD WINDOW 1 2" GWB 2x4 STUDS @16" OC 2x4 STUDS @16" OC W/ 21" GWB EA. SIDE VAPOR BARRIER BATT INSUL. (R-13) EXT. GRADE PLYWD TRIM EXT. GRADE PLYWD. SHEATHING; TYVEK WRAP; 1-1/2" RIGID INSUL. (R-7.5); 3 8" EXT. GRADE PLYWD SHEATHING (PAINT WHITE) BACKER ROD & SEALANT FLASHING 2x6 NAILER PROVIDE NEW 21" EXT. GRADE PLYWD SHEATHING; ICE & WATER SHIELD, ARCH. ASPHALT SHINGLES; ALUM. DRIP EDGE, & ALUM. GUTTERS PROVIDE NEW FASCIA BD. & ALUM. VENTED SOFFIT EXIST. 2x6 EAVE FRAMING; REPLACE AS REQ'D. EXIST. FLOOR JOISTS EXIST. T&G WOOD FLOOR A3 1 2 3 EXIST. MASONRY WALL 1 2" EXT. GRADE PLYWD SHEATHING; TYVEK WRAP SECTION SCALE: 3/8" = 1'-0" 4 5 6 A 8'-5" 7'-6" REMOVE EXIST. RAFTER SUPPORTS AT NEW DORMER LOCATIONS ONLY A INSTALL (3)2x8 HEADER SUPPORT FOR EXIST. ROOF; APPLY SLOPEABLE JOIST HANGERS TO NEW HEADERS CUT EXIST. RAFTERS @8'-5" AFF. (MATCH CHORD) 3 8" 1 2" 7'-3" MATCH EXIST. B.O. HEADER 3'-5" 3'-10" ACT HUNG FROM EXIST. 2x8 CHORDS ASPHALT SHINGLES TO RETURN UP WALL ON EXTERIOR; TYPICAL ALL DORMERS (NEW & EXIST.) HEADER: (2)2x6 W/ 21" PLYWD SPCR SA JOB #: 10030 DRAWING #: DATE: 10-04-11 A-301 1 2 3 4 5 6 E E NOTICE This document, the property of, prepared and issued by the architect, is submitted for the specific project namely and the recipient by accepting this document assumes custody and agrees that this document will not be copied or reproduced in part or in whole, and any special features peculiar to this design shall not be incorporated in any other project, unless prior agreement has been obtained in writing.These documents will be returned immediately upon completion of the project or upon the request of the architect. This document is the exclusive property of the architect, no rights to ownership are transferable, or shall be lost by the filing of this document with any and all public authorities for the purpose of compliance with Codes and or Ordinances, i.e. Building Permit, etc. Savarino Companies D D 26 Mississippi St Buffalo, NY 14203 Altamont VA Homeless Shelter 30 Wyoming Ave Buffalo, NY ISSUE: 7'-9" A1 C TOWEL HOOK 3'-0" A3 TOWEL BAR A4 TOILET PAPER DISPENSOR 3'-0" C 1'-421" A-401 7'-7" A6 SA PROJECT TEAM: PRINCIPAL P.Silvestri PROJ. ARCH. DRAFTER M. Merkwa INTERIORS A. Fornataro SEAL: 3'-0" 4'-0" JOB CAPT. CURTAIN ROD W/ CURTAIN FIBERGLASS SHOWER STALL TITLE: 3-1/2" SPINKLER LEADER EXIST. 4-1/2" VENT B B ENLARGED PLANS & DETAILS B6 FLOUR. FIXTURE BATHROOM PLAN SCALE: 1/2" = 1'-0" SHOWER CURTAIN ROD TOWEL HOOK FRAMED MIRROR VANITY SHELF 7'-6" A 5'-0" 5'-634" 3'-0" 3'-0" SA JOB #: 1'-9" 3'-0" 6'-6" 2'-0" 7'-0" 6" 7'-6" 6" PAPER DISPENSER 4'-0" 3'-0" 3'-0" PROVIDE BLOCKING W/IN WALL FOR FUTURE GRAB BAR 5'-634" 6'-8" 7'-6" 6'-8" 3'-6" A 6'-0" 7'-6" TOWEL BAR 10030 VINYL BASE A1 1 VINYL BASE BATHROOM ELEVATION A3 SCALE: 1/2" = 1'-0" 2 BATHROOM ELEVATION SCALE: 1/2" = 1'-0" 3 VINYL BASE A4 4 DRAWING #: VINYL BASE BATHROOM ELEVATION A6 SCALE: 1/2" = 1'-0" 5 BATHROOM ELEVATION SCALE: 1/2" = 1'-0" 6 DATE: 10-04-11 A-401 1 2 4 3 5 6 NOTICE 301 BEDROOM CPT-1 302 BEDROOM 303 E ROOM NAME FLOOR CEILING BASE REMARKS North South East West MATL CPT-1 PT-1 PT-1 PT-1 PT-1 GWB CPT-1 CPT-1 PT-1 PT-1 PT-1 PT-1 GWB BEDROOM CPT-1 CPT-1 PT-1 PT-1 PT-1 PT-1 GWB 304 BEDROOM CPT-1 CPT-1 PT-1 PT-1 PT-1 PT-1 GWWB 305 BEDROOM CPT-1 CPT-1 PT-1 PT-1 PT-1 PT-1 ACT-1 306 BEDROOM CPT-1 CPT-1 PT-1 PT-1 PT-1 PT-1 NO CHANGES OR SUBSTITUTIONS WILL BE MADE TO THE FOLLOWING FINISHES UNLESS DIRECTED BY THE OWNER OR ARCHITECT. ACOUSTICAL CEILING TILE (ACT-1) ACT-1: ARMSTRONG ULTIMA OR APPROVED EQUAL. MANY FINISH MATERIALS REQUIRE A SUBSTANTIAL LEAD TIME. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO ORDER ALL MATERIALS AT THE APPROPRIATE TIME. ANY FEE'S INCURRED AS A RESULT OF FINISHES NOT BEING ORDERED ON TIME WILL BE THE RESPONSIBILITY OF THE CONTRACTOR. PAINT (PT): ANY AND ALL FINISH SELECTIONS/ COLORS MUST BE SUBMITTED TO ARCHITECT FOR APPROVAL ACCOUNTING FOR PROPER LEAD TIME. ANY FINISH THAT IS INSTALLED WITHOUT ARCHITECTS APPROVAL MAY BE REQUIRED TO BE REMOVED AND REPLACED BY THE GENERAL CONTRACTOR. PT-2: SHERWIN WILLIAMS, COLOR: MOUNTAIN ROAD (FRAMES), FINISH: SEMI GLOSS PT-1: SHERWIN WILLIAMS, COLOR: TECHNO GRAY (FIELD PAINT), FINISH: SATIN CARPET (CPT): CPT-1: SHAW, NEYLAND II 26 ALL CABINET HARDWARE SHALL BE SATIN CHROME. ACT-1 E WALLS ROOM NUMBER WALL FINISHES GENERAL FINISH NOTES ROOM FINISH SCHEDULE Savarino Companies VINYL COMPOSITION TILE (VCT): GYPSUM BOARD CEILINGS ARE TO BE PAINTED CEILING WHITE UNLESS OTHERWISE NOTED ON THE REFLECTED CEILING PLAN. 307 BEDROOM CPT-1 CPT-1 PT-1 PT-1 PT-1 PT-1 ACT-1 308 BEDROOM CPT-1 CPT-1 PT-1 PT-1 PT-1 PT-1 ACT-1 309 BEDROOM CPT-1 CPT-1 PT-1 PT-1 PT-1 PT-1 ACT-1 310 BEDROOM CPT-1 CPT-1 PT-1 PT-1 PT-1 PT-1 ACT-1 311 BATHROOM VCT-1 VB-1 PT-1 PT-1 PT-1 PT-1 ACT-1 312 CORRIDOR CPT-1 CPT-1 PT-1 PT-1 PT-1 PT-1 GWB/ACT-1 313 EXISTING STAIR EXIST. EXIST. EXIST. EXIST. EXIST. EXIST. EXIST. NIC ALL FLOORING TO CONTINUE UNDERNEATH ALL MILLWORK. 314 EXISTING STAIR EXIST. EXIST. EXIST. EXIST. EXIST. EXIST. EXIST. NIC ALL HARDWARE TO BE SATIN CHROME. VCT-1: MANNINGTON COMMERCIAL, COLOR: 129 - PUTTY VINYL BASE: JOHNSONITE, 32 - PEBBLE WG ALL MECHANICAL DUCT COVERS SHALL BE PAINTED TO MATCH THE SURROUNDING WALL/ CEILING COLOR. This document, the property of, prepared and issued by the architect, is submitted for the specific project namely and the recipient by accepting this document assumes custody and agrees that this document will not be copied or reproduced in part or in whole, and any special features peculiar to this design shall not be incorporated in any other project, unless prior agreement has been obtained in writing.These documents will be returned immediately upon completion of the project or upon the request of the architect. This document is the exclusive property of the architect, no rights to ownership are transferable, or shall be lost by the filing of this document with any and all public authorities for the purpose of compliance with Codes and or Ordinances, i.e. Building Permit, etc. 26 Mississippi St Buffalo, NY 14203 PROVIDE (1) COAT WALL PRIMER FOLLOWED BY (2) COATS WALL PAINT ON ALL INTERIOR WALL SURFACES. SEE FLOOR PLAN (SHEET A-101) FOR TRUE NORTH. PROVIDE MARBLE THRESHOLD AT ALL TOILET ROOM LOCATIONS. PROVIDE ARCHITECT WITH COLOR SAMPLES DURING SUBMITTAL PROCESS. D D USE APPROPRIATE RUBBER & SCHLUTER TRANSITIONS WHERE FLOOR MATERIALS MEET. SUBMIT STYLE(S) AND COLOR(S) TO ARCHITECT FOR APPROVAL. Altamont VA Homeless Shelter 30 Wyoming Ave Buffalo, NY ISSUE: DOOR AND FRAME SCHEDULE 3'-5" 7'-2" VIF EXACT EXIST. R.O. 3'-11" 3'-11" C DOOR NUM. HARD WARE FRAMES DOOR OPN'G SIZE LOCATION TYPE THK WIDTH HEIGHT FIRE RATING DETAILS MAT'L FINISH MAT'L FINISH TYPE HEAD JAMB REMARKS SET NO. 301 BEDROOM 301 F 2'-8" 6'-8" 1-3/4" SCWD PAINT HM PAINT A H1 J1 -- HW1 302 BEDROOM 302 F 2'-8" 6'-8" 1-3/4" SCWD PAINT HM PAINT A H1 J1 -- HW1 303 BEDROOM 303 F 2'-8" 6'-8" 1-3/4" SCWD PAINT HM PAINT A H1 J1 -- HW1 304 BEDROOM 304 F 2'-8" 6'-8" 1-3/4" SCWD PAINT HM PAINT A H1 J1 -- HW1 305 BEDROOM 305 F 2'-8" 6'-8" 1-3/4" SCWD PAINT HM PAINT A H1 J1 -- HW1 306 BEDROOM 306 F 2'-8" 6'-8" 1-3/4" SCWD PAINT HM PAINT A H1 J1 -- HW1 307 BEDROOM 307 F 2'-8" 6'-8" 1-3/4" SCWD PAINT HM PAINT A H1 J1 -- HW1 308 BEDROOM 308 F 2'-8" 6'-8" 1-3/4" SCWD PAINT HM PAINT A H1 J1 -- HW1 309 BEDROOM 309 F 2'-8" 6'-8" 1-3/4" SCWD PAINT HM PAINT A H1 J1 -- HW1 310 BEDROOM 310 F 2'-8" 6'-8" 1-3/4" SCWD PAINT HM PAINT A H1 J1 -- HW1 311 BATHROOM F 2'-8" 6'-8" 1-3/4" SCWD PAINT HM PAINT A H1 J1 -- HW1 315 CLOSET AC 2'-0" 3-0" 1-3/4" SCWD PAINT WD PAINT B H2 J2 - HW2 C DOORS PRINCIPAL P.Silvestri PROJ. ARCH. DRAFTER JOB CAPT. M. Merkwa INTERIORS A. Fornataro SEAL: REPLACMENT VINYL CLAD NEW VINYL CLAD 2 1 VERIFY EXIST. R.O. WINDOW NOTES: 10'-0" VIF EXACT EXIST. R.O. 1. ALL REPLACEMENT WINDOWS SIZES TO BE FIELD VERIFIED PRIOR TO PURCHASE. TITLE: 1" UNDERCUT 3. FIXED SCREENS TO BE PROVIDED W/ ALL WINDOW UNITS. HARDWARE SCHEDULE 4. RE-FRAME EXISTING ROUGH OPENINGS AS REQ'D. * PROVIDE SOLID WOOD BLOCKING AT ALL WALL STOPS * ALL HARDWARE TO BE ADA COMPLIANT 5. PROVIDE FLASHING AT ALL WINDOW HEADS AND SILLS. REPLACMENT VINYL CLAD 3 B 3'-11" 2. ALL WINDOWS TO BE VINYL CLAD WOOD WINDOWS IN WHITE. B SA PROJECT TEAM: HDW-1 EACH DOOR TO HAVE: 3- HINGES 1- PRIVACY LOCKSET 1- WALL STOP 6. ALL WINDOWS BY PELLA OR APPROVED EQUAL. VERIFY EXIST. R.O. 5/8" DRYWALL BOTH SIDES 2x4 STUDS @ 16" O.C. (2) 2x6 W/ PLYWD SPCR SHIM AS REQ'D. HDW-2 EACH DOOR TO HAVE: 2-HINGES 1- STOREROOM LOCKSET 1- WALL STOP H.M. FRAME 5/8" DRYWALL BOTH SIDES 2x4 STUDS @ 16" O.C. (2) 2x6 W/ PLYWD SPCR WOOD TRIM DOOR, REFER TO SCHEDULE WINDOW TYPES ROOM FINISH SCHEDULE, WINDOW & DOOR SCHEDULE 1x TRIM BD. DOOR, REFER TO SCHEDULE WOOD STOP 2" SEE SCHEDULE 2" H1 2" SEE SCHEDULE H2 SHIM AS REQ'D. DOOR, REFER TO SCHEDULE DOOR, REFER TO SCHEDULE DBL. 2x4 STUDS @16" OC 2" SEE SCHEDULE 2" 3'-0" 3'-0" A A 2" 6'-8" 6'-8" SEE SCHEDULE WOOD TRIM DBL. 2x4 STUDS @ 16" O.C. 5/8" DRYWALL BOTH SIDES H.M. FRAME F FLUSH DOOR AC DOOR TYPES 1 2 ACCESS DOOR A 3 J1 B FRAME TYPES 5/8" DRYWALL BOTH SIDES 1x TRIM BD. WOOD STOP 10030 DRAWING #: 5 DATE: 10-04-11 J2 DOOR DETAILS 4 SA JOB #: 6 A-601
© Copyright 2024