SITE INVESTIGATION FACTUAL REPORT Report No: 148670 Client: Cunningham Lindsey - Solent Site: 77 Hillyard Road, London Client Ref: 7379021-Mr Ioannou Date of Visit: 23/07/2013 Home Emergency Response - Subsidence Investigation - Drainage Services – Crack & Level Monitoring – Property Video Surveys Unit E2 First Floor Suite, Boundary Court ( 0843 2272362 CET is the trading name of CET Structures Ltd Willow Farm Business Park, Castle Donington * [email protected] : www.cet-uk.com Registered in England No. 02527130 Leicestershire, DE74 2NN Investigation Layout Plan MD (SI) 1 of 1 Job No: 148670E Date: 23/07/2013 Site: 77 Hillyard Rd, W7 1BJ Work carried out for: Weather: RAIN AR PS Sheet: Cunningham Lindsey (Drawn) (Checked) REAR LAWN TREE HT: 14m D: 12m SOAK AWAY? 3.5 m TREE HT: 7m D: 6m DECKING TREE HT: 12m D: 9m 3.0 m TP/BH1 RWP2 CONS B SVP RWP1 A TP/BH2 3.0 m WG1 2.6 m 0.2m NO.79 NO.77 NO.75 BH3 + DATUM HEDGE HT: 1m D: 3.5m TREE HT: 12m D: 10m ON SITE TREE IDENTIFICATION FOR GUIDANCE ONLY. NOT AUTHENTICATED. Remarks: Key: Unable to test SVP, it was boxed in inside conservatory. Parking - road. Water supply - outside tap. Scale: N.T.S. Combined Gulley RWWG Surface Water Drain Manhole MH Foul Water Drain Rain Water Pipe RWP Tree / Bush Rain Water Gulley RWG (approx. ht in m) Soil Vent Pipe SVP Waste Gulley WG Waste Pipe WP Trial Pit Borehole TREES HT: 10m D: 9m Sheet: Trial Pit No: 1 1 of 1 Job No: 148670E Site: 77 Hillyard Rd, W7 Date: 23/07/2013 Excavation Method: Hand tools Drawn by: AR Weather: Dry Ground Level mOD: Work carried out for: Cunningham Lindsey 500 X 400 25 JOISTS 190 BRICK DECKING 70 Ground Level JOISTS 200 CONCRETE FOUNDATION 95 75 390 400 MADE GROUND: Medium compact, dark brown / orange, silty clay with occasional gravel and brick fragments. D M 20 27 27 22 690 Roots to 1mmØ. FOR STRATA BELOW 590mm SEE BH1 LOG Remarks: All measurements in millimetres. Key: D Small disturbed sample J Jar sample B Bulk disturbed sample V Pilcon Vane (kPa) W Water sample M Mackintosh probe TDTD Too dense to drive Logged: MD Checked: PS Approved: Scale: N.T.S. Sheet: Trial Pit No: 2A 1 of 2 Job No: 148670E Site: 77 Hillyard Rd, W7 Date: 23/07/2013 Excavation Method: Hand tools Drawn by: AR Weather: Dry Ground Level mOD: Work carried out for: Cunningham Lindsey 600 X 400 Ground Level 160 200 BRICK AND CONCRETE FOUNDATION 25 85 JOISTS 55 CONCRETE 200 75 DECKING CONCRETE AND BRICK RUBBLE MADE GROUND: Medium compact, dark brown / orange, silty clay with occasional gravel and brick fragments. 260 165 BRICK No roots observed. 700 CONCRETE UNDERPIN 800 Stiff mid brown / orange, grey veined, silty CLAY with partings of orange and brown silt and fine sand. No roots observed. D V 104 98 FOR STRATA BELOW 1425mm SEE BH2 LOG Remarks: All measurements in millimetres. Key: D Small disturbed sample J Jar sample B Bulk disturbed sample V Pilcon Vane (kPa) W Water sample M Mackintosh probe TDTD Too dense to drive Logged: MD Checked: PS Approved: Scale: N.T.S. Sheet: Trial Pit No: 2B 2 of 2 Job No: 148670E Site: 77 Hillyard Rd, W7 Date: 23/07/2013 Excavation Method: Hand tools Drawn by: AR Weather: Dry Ground Level mOD: Work carried out for: Cunningham Lindsey Ground Level 165 BRICK 200 150 CONCRETE FOUNDATION 365 STRATA as TP2 SHEET 1 of 2 D M 16 16 19 24 665 Remarks: All measurements in millimetres. Key: D Small disturbed sample J Jar sample B Bulk disturbed sample V Pilcon Vane (kPa) W Water sample M Mackintosh probe TDTD Too dense to drive Logged: MD Checked: PS Approved: Scale: N.T.S. Borehole No: Sheet: 1 1 of 1 Job No: 148670E D10001 Boring Method: Diameter: 80mm Depth (m) Site: 77 Hillyard Road, W7 Work Carried out for: Cunningham Lindsey 23/07/2013 Hand Auger Date: Coordinates: Ground Level mOD: ThickTest ness Legend Sample Type Result (m) Description of Strata As Trial Pit 1 Depth (m) Roots to 1mm diameter to 1.3m MADE GROUND: medium compact dark brown/orange silty clay with 0.70 occasional gravel & brick fragments 0.11 Stiff mid brown/orange, grey veined silty CLAY with partings of orange & brown silt & fine sand 0.80 1.50 Stiff mid brown/orange, grey veined silty CLAY thinly laminated with orange & brown silt & fine sand 0.50 2.00 Stiff moist as above with occasional 2.10 gravel BH ends at 2.1m Obstruction: Thought to be gravel too dense to hand auger 0.10 Remarks: BH moist at base & open on completion MD Depth to water (m) 0.59 0.59 Logged: Field Records/Comments Checked: PS Drawn by SL __.x __ __ __ __ __ x __ __ __ __ __ __ __.x __ __ __ __ __ x __ __.x __ __ D V 100 110 1.00 No roots observed below 1.3m D V D M 100 100 1.50 29 2.00 Water seepage 41 50(70) 50(50) Key: T.D.T.D. Too Dense to Drive D Small disturbed sample J Jar sample B Bulk disturbed sample V Pilcon Vane (kPa) M Mackintosh Probe W Water sample Scale: NTS Weather: Dry 2.00 Borehole No: Sheet: 2 1 of 1 Job No: 148670E Boring Method: Diameter: 80mm Depth (m) Site: 77 Hillyard Road, W7 Work Carried out for: Cunningham Lindsey 23/07/2013 Hand Auger Date: Coordinates: Ground Level mOD: ThickTest ness Legend Sample Type Result (m) Description of Strata As Trial Pit 2 Depth (m) 1.425 Field Records/Comments Depth to water (m) No roots observed 1.425 Stiff mid brown/orange, grey veined silty CLAY with partings of orange & brown silt & fine sand 2.00 Stiff as above thinly laminated with orange & brown silt & fine sand 3.20 __.x __ __ 0.575 __ __ __ x __ __ __ __.x __ __ __ 1.20 __ __ x __ __ __ __ __ __ __x. __ __ __ __x__ D V 100 96 1.50 D V 96 92 2.00 D V 120 130+ 2.50 Water seepage Water standing on completion D V 130+ 130+ 3.00 BH ends at 3.2m Obstruction: Thought to be gravel too dense to hand auger Remarks: Key: T.D.T.D. Too Dense to Drive Jar sample D Small disturbed sample J V Pilcon Vane (kPa) B Bulk disturbed sample M Mackintosh Probe W Water sample BH open on completion Logged: MD Checked: PS Drawn by SL Scale: NTS Weather: Rain 2.50 2.80 Borehole No: Sheet: 3 Job No: 148670E & DATUM Boring Method: Diameter: 1 of 1 CFA Date: Depth 77 Hillyard Road, W7 Work Carried out for: Cunningham Lindsey 23/07/2013 Ground Level mOD: 100mm Coordinates: Site: Thick- (m) Description of Strata ness Legend Sample Type Test Result (m) Depth Depth Field Records/Comments (m) to water (m) G/L Topsoil over MADE GROUND: medium compact dark brown/orange, silty clay with occasional gravel & brick fragments 0.50 0.50 Stiff mid brown/orange, grey veined, silty CLAY with partings of orange & brown silt & fine sand 2.70 3.20 Stiff as above with numerous gravel 0.60 3.80 Stiff dark brown/orange, silty CLAY with partings of orange & brown silt & fine sand 2.20 6.00 __.x __ __ __ __ __ x __ __ __ __ __ __ __x. __ __ __ __x__ __ __ __ __ __ __ __ __ __ x.__ __ __ __.x __ __ __.x __ __ __o __ __ __.x __ __ __ __ __ x __ __ __ __ __ __ __x. __ __ __ __x__ D V 120 120 0.50 Roots to 1mm diameter to 1.8m D V 124 120 1.00 D 1.50 No roots observed below 1.8m D V 112 120 D D 2.00 2.50 V 130+ 130+ D 3.00 3.50 Water strike D V 130+ 130+ D D 4.00 4.50 Water standing on completion V 130+ 130+ 5.00 BH ends at 6.0m Remarks: BH open on completion Datum installed at 6.0m - no soil samples taken or insitu strength tests carried out below 5.0m Logged: MD Checked: PS Drawn by SL 3.80 Key: T.D.T.D. Too Dense to Drive D Small disturbed sample J Jar sample B Bulk disturbed sample V Pilcon Vane (kPa) M Mackintosh Probe W Water sample Scale: Weather: Rain NTS 4.50 Our Ref : 148670 Location : Work carried out for: TP/BH No Sample Ref Depth (m) Laboratory Testing Results Date Sampled: 23/07/2013 77, Hillyard Road, W7 Date Received : 24/07/2013 Cunningham Lindsey - Solent Date Tested : Date of Report : 24/07/2013 26/07/2013 Type Moisture Content ( % ) [1] 1 Soil Fraction > 0.425mm ( % ) [2] Liquid Limit Plastic Limit ( % ) [3] ( % ) [4] Plasticity Index Liquidity Index ( % ) [5] [5] Modified Plasticity Index ( % ) [6] Soil Class [7] Filter Paper Contact Time ( h ) [8] Soil Sample Suction (kPa) In situ Shear Vane Strength (kPa) [9] 0.39(U/S) D 20 14 46 17 29 0.10 25 CI 1.0 D 27 <5 77 21 55 0.11 55 CV 105 1.5 D 21 <5 49 16 33 0.16 33 CI 100 2.0 D 16 42 49 16 33 0.00 19 CI Organic Content ( % )[10] Test Methods / Notes [9] Values of shear strength were determined in situ by CET using Key [1] BS 1377 : Part 2 : 1990, Test No 3.2 [2] Estimated if <5%, otherwise measured [3] BS 1377 : Part 2 : 1990, Test No 4.4 [4] BS 1377 : Part 2 : 1990, Test No 5.3 [5] BS 1377 : Part 2 : 1990, Test No 5.4 [6] BRE Digest 240 : 1993 [7] BS 5930 : 1981 : Figure 31 - Plasticity Chart for the classification a Pilcon hand vane or Geonor vane (GV). [10] BS 1377 : Part 3 : 1990, Test No 4 [11] BS 1377 : Part 2 : 1990, Test No 9 [12] BS 1377 : Part 3 : 1990, Test No 5.6 D B U W ENP U/S of fine soils [8] In-house method S9a adapted from BRE IP 4/93 [13] SO4 = 1.2 x SO3 [14] BRE Special Digest One (Concrete in Aggressive Ground) August 2005 Note that if the SO4 content falls into the DS-4 or DS-5 class, it would be prudent to consider the sample as falling into the DS-4m or DS-5m class respectively unless water soluble magnesium testing is undertaken to prove otherwise pH Value [11] Sulphate Content (g/l) SO3 SO4 [12] [13] Disturbed sample ( small ) Disturbed sample ( bulk ) Undisturbed sample Groundwater sample Essentially Non-Plastic by inspection Underside of Foundation Class [14] Our Ref : 148670 Location : Work carried out for: Date Sampled : 23/07/2013 77, Hillyard Road, W7 Date Received : 24/07/2013 Cunningham Lindsey - Solent Date Tested : Date of Report : 24/07/2013 26/07/2013 Sample Ref. TP/BH Depth No. (m) Laboratory Testing Results Type Moisture Content ( % ) [1] 2 Soil Fraction > 0.425mm ( % ) [2] Liquid Limit ( % ) [3] Plastic Limit ( % ) [4] Plasticity Index Liquidity Index ( % ) [5] [5] Modified Plasticity Index ( % ) [6] Soil Class [7] 0.37(U/S) D 27 12 54 19 34 0.22 30 CH 1.23(U/S) D 24 <5 58 19 39 0.12 39 CH 1.5 D 27 <5 2.0 D 25 <5 2.5 D 27 6 3.0 D 27 10 Filter Paper Contact Soil Sample In situ Shear Vane Time ( h ) [8] Suction (kPa) Strength (kPa) [9] Organic Content pH Value Sulphate Content (g/l) SO3 ( % )[10] [11] [12] [13] 101 98 54 16 37 0.24 37 CH 94 125 51 16 35 0.32 31 CH > 130 Test Methods / Notes [9] Values of shear strength were determined in situ by CET using Key [1] BS 1377 : Part 2 : 1990, Test No 3.2 [2] Estimated if <5%, otherwise measured [3] BS 1377 : Part 2 : 1990, Test No 4.4 [4] BS 1377 : Part 2 : 1990, Test No 5.3 [5] BS 1377 : Part 2 : 1990, Test No 5.4 [6] BRE Digest 240 : 1993 [7] BS 5930 : 1981 : Figure 31 - Plasticity Chart for the classification of fine soils [8] In-house method S9a adapted from BRE IP 4/93 a Pilcon hand vane or Geonor vane (GV). [10] BS 1377 : Part 3 : 1990, Test No 4 [11] BS 1377 : Part 2 : 1990, Test No 9 [12] BS 1377 : Part 3 : 1990, Test No 5.6 D B U W ENP U/S [13] SO4 = 1.2 x SO3 [14] BRE Special Digest One (Concrete in Aggressive Ground) August 2005 Note that if the SO4 content falls into the DS-4 or DS-5 class, it would be prudent to consider the sample as falling into the DS-4m or DS-5m class respectively unless water soluble magnesium testing is undertaken to prove otherwise Class SO4 Disturbed sample ( small ) Disturbed sample ( bulk ) Undisturbed sample Groundwater sample Essentially Non-Plastic by inspection Underside of Foundation [14] Moisture Content and Shear Strength Profiles Our Ref : 148670 Location : 77, Hillyard Road, W7 Work carried out for: Cunningham Lindsey - Solent Note : Unless specifically noted the profiles have not been related to a site datum. Moisture Content Profile(s) Date Sampled : 23/07/2013 Date Received : 24/07/2013 Date Tested : Date of Report : 24/07/2013 26/07/2013 Shear Strength Profile (s) Soil Moisture Content (%) In Situ Shear Strength (kPa) 12 16 20 24 28 32 0 0.0 20 40 60 80 100 120 0.0 TP/BH1 TP/BH2 TP/BH1 1.0 1.0 2.0 Depth (m) Depth (m) TP/BH2 2.0 3.0 3.0 4.0 4.0 Notes Note 1. If plotted, 0.4 LL and PL+2 ( after Driscoll, 1983 ) should only be applied to London Clay Unless otherwise stated, values of Shear Strength were determined in situ by ( and similarly overconsolidated clays ) at shallow depths. CET using a Pilcon Hand Vane the calibration of which is limited to a maximum reading of 130 kPa. 140 160 Moisture Content and Suction Profiles Our Ref : 148670 Location : 77, Hillyard Road, W7 Work carried out for: Cunningham Lindsey - Solent Note : Unless specifically noted the profiles have not been related to a site datum. Moisture Content Profile(s) 16 20 24 28 Date Received : 24/07/2013 Date Tested : Date of Report : 24/07/2013 26/07/2013 Soil Sample Suction ( kPa) 32 0 0.0 200 400 600 800 0.0 TP/BH1 TP/BH2 1.0 2.0 1.0 Depth (m) Depth (m) 23/07/2013 Suction Profile(s) Soil Moisture Content (%) 12 Date Sampled : 2.0 3.0 3.0 4.0 4.0 Notes Note 1. If plotted, 0.4 LL and PL+2 ( after Driscoll, 1983 ) should only be applied to London Clay When shown, the theoretical equilibrium suction profiles are based on conventional assumptions associated ( and similarly overconsolidated clays ) at shallow depths. with London Clay (and similarly overconsolidated clays) at shallow depths. Note that the sample disturbance component is dependant on the method of sampling and any subsequent recompaction. The above plots show this to be 100kPa which is the value suggested by the BRE on the basis of their limited number of tests on recompacted samples. This may or may not be appropriate in this instance and judgement should be exercised. 1000 Sheet: 1 of 1 Site: EPSL European Plant Science Laboratory Job No: 148670 Date: 30/07/2013 Order No: 458151 77 Hillyard Road, London, W7 Work carried out for: Cunningham Lindsey EPSL Ref: R2748 Certificate of Analysis The following work was commissioned by CET on behalf of their client. Root samples were obtained in sealed packets from the above site with no reference given as to the types of tree or shrub from which they may have originated. The results were as follows Trial pit/ Borehole number Root diameter (mm) Tree, shrub or climber from which root originates Result of starch test TP1 (USF) <1 mm Cupressaceae spp. Negative TP1 (USF) <1 mm Pomoideae gp. 2 roots Positive BH1 (to 1.3m) 1 mm Cupressaceae spp. 5 roots Positive BH3 (to 1.8m) <1 mm Euonymus spp. 4 roots Positive Cupressaceae spp. include Lawson cypress, western red cedar, Monterey cypress, Leyland cypress and junipers. Pomoideae gp include apple, cotoneaster, hawthorn, pear, pyracantha, quince, rowan, snowy mespil and whitebeam. Euonymus spp. are deciduous or evergreen garden shrubs, including spindleberries. MPD Address for correspondence: EPSL , Intec, Parc Menai, Bangor, Gwynedd, North Wales, LL57 4FG Telephone: 01248 672 652 e-mail: [email protected] Head of Laboratory Services : M D Mitchell B.Sc. (Hons), M.Phil. Plant Anatomist : Dr G S Turner B.Sc. (Hons), M.Sc., Ph.D Consultant: Dr M P Denne B.Sc. (Hons), M.Sc., Ph.D Registered in England. No 295427, Registered Office: 6G Greensfield Court, Alnwick, Northumberland, NE66 2DE To: Cunningham Lindsey - Solent Our Ref: 148670 Your Ref: 7379021 Date: 24-Jul-13 Solent House Solent Business Park Whiteley Hants PO15 7AF Ftao: James Dobson ESTIMATE Site:- 77 Hillyard Road, London Item 1.0 Amount Location Shared System Condition Grade Drain Serviceability Rwp 1 downstream No B Unserviceable Work Spec Excavate and replace the rest bend and 1.0 metre of pipe-work £294.53 The decking will need to be removed/replaced by others to allow for the works Notes Repairs to shared runs and off boundary pipe-work may be the responsibility of the water authority. Condition Grade A - Structurally sound with no leakage evident. B - Cracks and fractures observed. C - Structurally unsound Total £294.53 plus VAT @20% £58.91 Total + VAT £353.43 Quotation is binding only if accepted within 28 days from date of issue and is subject to our Standard Terms and Conditions The price qualification notes, stated on the drainage solutions schedule of rates, apply to this quotation. CET Structures Ltd undertakes to return to site free of charge to carry out remedial work to the drainage repairs set out above for a period of 2 months from the date of this invoice. The company standard charge rates will apply to the visit should the work requested be unrelated to the said repairs. ESTIMATING & COSTING SHEET - DOMESTIC DRAINAGE Site:- 77 Hillyard Road, London Client :Attention of:- Client ref Job Number :Insurer Date:Recommendation Cunningham Lindsey - Solent James Dobson Description Rwp 1 downstream Item No Unit Quantity 7379021 148670 AVIVA 24-Jul-13 1 Rate (£) Price (£) 1.0 1.1 1.2 1.3 1.4 Emergency Drain Blockage Clearance Unblock drain 8am-6pm - First 1/2 Hour Unblock drain 8am-6pm- Subsequent 1/2 Hour Unblock drain 6pm-midnight Unblock drain 6pm-midnight - Subsequent 1/2 hour Item Item Item Item £70.00 £30.00 £100.00 £35.00 £0.00 £0.00 £0.00 £0.00 2.1 2.2 2.3 CCTV Surveys Undertake CCTV survey 8am-6pm (up to 3 hours) Additional 1/2 hr survey charge Item Item £130.00 £30.00 £0.00 £0.00 3.0 Replacing Underground Drainage Item Item £130.00 £90.00 £0.00 £0.00 £90.00 £120.00 £0.00 £70.00 £70.00 £70.00 £70.00 £70.00 £70.00 £0.00 £0.00 £0.00 £0.00 £0.00 £0.00 £95.00 £120.00 £95.00 £120.00 £0.00 £0.00 £0.00 3.1 Gullies 3.2 3.3 Take out and replace gulley (100mm outlet) Take out and replace rodding point (100mm outlet) 3.4 Bends/junctions 3.5 3.6 Excavate and replace rest bend (100mm outlet) Excavate and replace rest bend (150mm outlet) Item Item 3.7 3.8 3.9 3.10 3.11 3.12 Excavate and replace junction/bend (100mmØ), Excavation depth 0-1m. Excavate and replace junction/bend (150mmØ), Excavation depth 0-1m Excavate and replace junction/bend (100mmØ), Excavation depth 1-1.5m. Excavate and replace junction/bend (150mmØ), Excavation depth 1-1.5m. Excavate and replace junction/bend (100mmØ), Excavation depth 1.5-2.0m. Excavate and replace junction/bend (150mmØ), Excavation depth 1.5-2.0m. Item Item Item Item Item Item 3.13 3.14 3.15 3.16 3.17 Excavate trench and replace 100mmØ pipework, Excavation depth 0-1m, First 10m. Excavate trench and replace 150mmØ pipework, Excavation depth 0-1m, First 10m. Excavate trench and replace 100mmØ pipework, Excavation depth 0-1m. Excavate trench and replace 150mmØ pipework, Excavation depth 0-1m. m m m m 3.18 3.19 3.20 3.21 Excavate trench and replace 100mmØ pipework, Excavation depth 1-1.5m, First 10m. Excavate trench and replace 150mmØ pipework, Excavation depth 1-1.5m, First 10m. Excavate trench and replace 100mmØ pipework, Excavation depth 1-1.5m. Excavate trench and replace 150mmØ pipework, Excavation depth 1-1.5m. m m m m £150.00 £160.00 £150.00 £160.00 £0.00 £0.00 £0.00 £0.00 3.22 3.23 3.24 3.25 Excavate trench and replace 100mmØ pipework, Excavation depth 1.5-2.0m, First 10m. Excavate trench and replace 150mmØ pipework, Excavation depth 1.5-2.0m, First 10m. Excavate trench and replace 100mmØ pipework, Excavation depth 1.5-2.0m. Excavate trench and replace 150mmØ pipework, Excavation depth 1.5-2.0m. m m m m £270.00 £290.00 £250.00 £270.00 £0.00 £0.00 £0.00 £0.00 3.26 3.27 3.28 3.29 3.30 3.31 3.32 3.33 3.34 3.35 3.36 Excavate through and reinstate turf. Excavate through and replace concrete paving slabs Excavate through and replace block paving Excavate through and reinstate plain concrete, maximum thickness 100mm. Excavate through and reinstate plain concrete, thickness 100- 200mm. Excavate through and reinstate reinforced concrete, maximum thickness 100mm. Excavate through and reinstate reinforced concrete, thickness 100-200mm. Excavate through and reinstate Tarmac - Cold rolled Excavate through and reinstate Tarmac - Hot rolled Reinstatement of crazy paving m m m m m m m m m £0.00 £30.00 £50.00 £47.00 £95.00 £90.00 £115.00 £48.00 POA £75.00 £0.00 £0.00 £0.00 4.0 Lining 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 Set up lining rig for drain lining including first 3m of lining per run, for 100mm or 150mm Line 100mmØ drain Line 150mmØ drain Post lining CCTV survey Minimum lining charge Root cutting of drain prior to lining Set up lining rig for patch lining Patch line 100mmØ drain Patch line 150mmØ drain Post patch lining CCTV survey Minimum patch lining charge Re-open lateral branch up to 2m length, pipe up to 150mm Re-open lateral branch over 2m length, pipe up to 150mm Item m m no Item hr Item no no Item Item no no £290.00 £50.00 £70.00 £100.00 £290.00 £65.00 £0.00 £250.00 £280.00 £100.00 £250.00 £190.00 £280.00 £0.00 £0.00 £0.00 £0.00 £0.00 £0.00 £0.00 £0.00 £0.00 £0.00 £0.00 £0.00 £0.00 Item % hr Item £400.00 1.25 £30.00 £346.50 £0.00 £0.00 £0.00 £346.50 £0.00 £0.00 £0.00 £0.00 £65.00 £90.00 £30.00 £80.00 £600.00 POA £20.00 £40.00 £0.00 £0.00 £0.00 £0.00 £0.00 1 Pipes 1 Surface Reinstatement of Trenches 5.0 Miscellaneous 5.1 5.2 5.3 5.4 5.5 5.6 5.7 5.8 Excavation and backfill of soakaway (1m3) with stone % Uplift on disbursements and suppliers charges Daywork - Hourly labour rate Minimum project value 6.0 Additional items 6.1 6.2 6.3 6.4 6.6 6.7 6.8 6.9 De-scaling (fat/grime) De-scaling (scale using chain flails) Gully surround Manhole works (up to 1.2m) Oversize soakaway (1.5m3) Soakaway >1.5m3 Waste disposal Shoring Total Estimate Price For Recommendation Number Subject to discount Total subject to VAT @ 20% Note: Subject to the attached Terms and Condtions A - When calculating prices, all measurements are rounded up C - Every effort will be made to match existing surfaces where disturbed although this cannot be guaranteed G - Daywork rates do not include for materials that are charged at cost plus 25% KEY: ne = not exceeding, eo = extra over rate, m = linear metre, nr = number, hr = hour hr hr item item item item m m 1 1 1 1.0 0.15 B - Depths are taken to the base of excavations D - All rates exclude VAT F - The above rates are subject to re-measurement E - Depths are taken to the base of excavations £0.00 £0.00 £0.00 £0.00 £0.00 £0.00 £346.50 £51.98 £294.53 Sheet: 1 of 3 Underground Drainage Report Site: 77 Hillyard Road, London Job No: 148670 Work carried Cunningham Lindsey - Solent Date: 23-Jul-13 out for: MANHOLE DETAILS Manhole Depth to Invert Condition CCTV Survey:1. Drainage Run: Break - in - waste gully 1 run X to downstream - 100mm clay foul water - Downstream ( not shared) Surface Material/ Metres: Code: Observations: Condition: 0.0 0.8 0.9 1.5 LR LD JN 1.6 2.5 5.2 LR DE FH Start Decking Slight Slight From 3 o'clock to 9 o'clock - 100mm enters main run - now shared 10% Reached downstream Water Test Grade: 0 - Unable to fill 1 - Heavy Loss 2 - Medium Loss over 2 minutes 3 - Slow Loss over 5 minutes 4 - No Loss Sheet: 2 of 3 Underground Drainage Report Site: 77 Hillyard Road, London Job No: 148670 Work carried Cunningham Lindsey - Solent Date: 23-Jul-13 out for: 2. Drainage Run: Break - in - rain water pipe 1 run X to downstream - 100mm clay surface water - Downstream ( not shared) Surface Material/ Metres: Code: Observations: Condition: 3 0.0 0.0 0.2 0.7 1.1 1.1 3.4 Start LD GO CC LR LD JN 3.5 5.3 LR FH Decking Line levels out From 12 o'clock to 12 o'clock Slight From 3 o'clock to 9 o'clock - 100mm enters main run - now shared Reached downstream Drainage Run: Break - in - rain water pipe 2 run X to downstream - 100mm plastic surface water - Downstream ( not shared) Surface Material/ Metres: Code: Observations: Condition: 0.0 1.7 3.2 4.0 DE DE FH Start 20% 60% Reached possible soakaway - END OF SURVEY - Water Test Grade: 0 - Unable to fill 1 - Heavy Loss 2 - Medium Loss over 2 minutes 3 - Slow Loss over 5 minutes 4 - No Loss Decking Sheet: 3 of 3 Underground Drainage Report Site: 77 Hillyard Road, London Job No: 148670 Work carried Cunningham Lindsey - Solent Date: 23-Jul-13 out for: Our assessment of the drainage system is based on our visual inspection and on information collated at the time of the survey. Where assumptions have been made these are based on our experience and do not constitute any form of guarantee, nor do we guarantee that further deterioration will not occur following this survey. CCTV video records will be stored for a period of 3 months from date of inspection and then destroyed. Water Test Grade: 0 - Unable to fill 1 - Heavy Loss 2 - Medium Loss over 2 minutes 3 - Slow Loss over 5 minutes 4 - No Loss CET STRUCTURES LTD TERMS AND CONDITIONS Site:- 77 Hillyard Road, London Client :Cunningham Lindsey - Solent Attention of:- James Dobson Client Ref:- 7379021 Job Number:Insurer:Date:- 148670 AVIVA 24-Jul-13 General Terms and Conditions 1 On site parking is a prerequisite of any drain repair contract. This quotation is to the addressee only and should not be forwarded unless prior agreement is obtained from CET Structures Ltd. Every effort will be made to match existing surfaces however, there will be evidence of excavation works in certain circumstances. 2 The rates do not include for excavation of surfaces other than soft ground or concrete < 100mm thick; reinstatement other than concrete <100mm thick; internal excavations; reinstatement >750mm in width; excavation of depths greater than 1.2m; reinforced concrete. 3 CET`s standard soakaway that is priced on the agreed alliance schedule of drainage rates is constructed to dimensions specified in the NHBC Guidelines for small soakaways. The soakaway is generally located 5m from any foundations (should site constraints permit) and is constructed to provide adequate short term surface water storage and percolation into surrounding ground. This small 1m3 soakaway is usually of sufficient capacity to accommodate average rainfall from an average surface area of roof space, however in extreme weather conditions and /or larger than average roof surface area feeding the soakaway, surcharging may occur.Alternative designs and prices are available at a cost along with percolation testing. Certain ground conditions may not be suitable for soakaway design due to low permeability and this information is not always readily available. Notes For excavation and reinstatement of any steps, will be done on day work rate. With a minimum of 4 hours. Materials at cost plus 25%. Any obstacles, shubs & plants that are located in the working area will need to be removed by others to allow for these works The decking will need to be removed/replaced by others to allow for the works No allowance has been made for the removal/replacement of the boundary fence Water Authority Sewer Condition Codes B Broken pipe at… (or from… to..) o'clock BR Branch Major JN JX Junction at…o'clock, diameter…mm Junction defective at.. o'clock, diameter.. mm LC Lining of sewer changes/starts/finishes at this point LD Line of sewer deviates down CM Cracks multiple from… to… o'clock LL Line of sewer deviates left CN CC CL Crack circumferential from… to… o'clock Crack longitudinal @… o'clock LN Line defect at (or from.. to.. ) o'clock CNI Connection at… o'clock, diameter… mm, intrusion… mm Connection at… o'clock, diameter… mm LR Line of sewer deviates right CU Camera under water LU Line of sewer deviates up CX Connection defective at… o'clock MB Missing bricks at.. (or from.. to..) o'clock CXI Connection defective at… o'clock, diameter… mm, MC Material of sewer changes at this point intrusion… mm MH Manhole/node D Deformed sewer… % MM Mortar missing medium at.. (or from.. to..) o'clock DB Displaced bricks at (or from.. to..) o'clock MS Mortar missing surface at.. (or from.. to..) o'clock DC Dimension of sewer changes at this point MT Mortar missing total at.. (or from.. to..) o'clock DE Debris (non silt/grease)… % cross-sectional loss OB Obstruction… % height/diameter loss DEG Debris grease… % cross-sectional area loss OJL Open joint large DES Debris silt… % cross-sectional area loss OJM Open joint medium DI PC Dropped invert, gap… mm EHJ Encrustation heavy from.. to.. o'clock % cross-sectional area loss (at joint) ELJ Encrustation light from.. to.. o'clock% new length…mm RFJ ESH Scale heavy… % cross-sectional area loss from... to… o'clock Roots fine (at joint) RMJ Roots mass… % cross-sectional area loss (at joint) EMJ Encrustation medium from.. to.. o'clock %, cross-sectional RTJ area loss (at joint) Length of pipe forming sewer changes at this point, Roots tap (at joint) SA Survey abandoned SC Shape of sewer changes at this point SSL Surface damage, spalling large at (or from.. to..) ESL Scale light from… to… o'clock o'clock ESM Scale medium… % cross-sectional area loss from… to… o'clock SSM Surface damage, spalling medium at (or from.. to..) FC Fracture circumferential from… to… o'clock SSS FL FM Fracture longitudinal at… o'clock Fractures multiple from… to… o'clock SWL Surface damage, wear large at… (or from.. to..) GO GP General observation at this point General photograph number… taken at this point H Hole in sewer at… o'clock IDJ Infiltration dripper at (or from… to…) o'clock (at joint) IGJ Infiltration gusher at (or from… to…) o'clock (at joint) IRJ Infiltration runner at (or from… to…) o'clock (at joint) V ISJ Infiltration seeper at (or from… to…) o'clock (at joint) WL o'clock Surface damage, spalling slight at (or from.. to..) o'clock o'clock SWM Surface damage, wear medium at… (or from.. to..) o'clock SWS Surface damage, wear slight at.. (or from.. to..) o'clock Vermin (rats and mice) Water level… % height/diameter JDM Joint displaced medium X Sewer collapsed… % cross-sectional area loss JDL FH End of survey Joint displaced large Contract: 148670 Site Address: 77 Hillyard Road, London M/H: Depth: Date: Operative Initial: Page: 1 of 1 Depths of run if different to invert level:A B C D E F G H Manhole Condition X Chamber Dimension (mm): M/H: Depth: Depths of run if different to invert level:A B C D E F G H Manhole Condition X Chamber Dimension (mm): M/H: Depth: Depths of run if different to invert level:A B C D E F G H Manhole Condition X Chamber Dimension (mm): KEY…. Internal Back Drop External Back Drop Run X Interceptor Water Pressure Test Results From: To: Pass / Fail
© Copyright 2024