CONTROL/ELEMENTARY SYMBOLS NORMALLY OPEN CONTACT NORMALLY CLOSED CONTACT LIMIT SWITCH, NORMALLY OPEN LIMIT SWITCH, NORMALLY CLOSED PRESSURE SWITCH, NORMALLY OPEN PRESSURE SWITCH, NORMALLY CLOSED FLOAT SWITCH, NORMALLY OPEN FLOAT SWITCH, NORMALLY CLOSED ELECTRICAL PLAN SYMBOLS SYSTEMS BACKBOARD AS NOTED S WALL OUTLET BOX AND 20 AMP SINGLE POLE SWITCH (`a' INDICATES SWITCHES) 48" TO CETERLINE S3 WALL OUTLET BOX AND 20 AMP 3-WAY SWITCH (`a' INDICATES SWITCHES) 48" TO CTR LINE. SV WALL OUTLET BOX AND EXHAUST FAN SPEED CONTROLLER/SWITCH CONNECTIONS. SM MANUAL MOTOR STARTING SWITCH WITH OVERLOADS AND PILOT LIGHT. NEMA 4X TYPICAL WALL OUTLET BOX AND 20 AMP SWITCH WITH PILOT LIGHT. S WP WALL OUTLET BOX AND 20 AMP SWITCH WITH WEATHERPROOF COVER OR ENCLOSURE. WALL OUTLET BOX AND 20 AMP DUPLEX RECEPT MOUNTED 48"AFF TEMPERATURE SWITCH, NORMALLY OPEN OR AS NOTED. KILOWATT METER WALL OUTLET BOX AND DOUBLE 20 AMP DUPLEX RECEPTACLES 18" TO CENTERLINE A AMMETER WALL OUTLET BOX AND SPECIAL PURPOSE RECEPTACLE AS NOTED OR COORDINATE. VS THREE PHASE VOLT SWITCH AS THREE PHASE AMP SWITCH AT CURRENT TRANSMITTER SLASH MARKS INDICATE NUMBER OF CONDUCTORS; (MARKS SHOWN TO AID CONTRACTOR IN BIDDING, KW KILOWATT TRANSMITTER OR NOT SHOWN). SHORT SLASHES INDICATE PHASE CONDUCTOR OR SWITCH LEG, LONG INDICATE PFT POWER FACTOR TRANSMITTER AR ALARM RELAY AT ALARM TIMER CR CONTROL RELAY BRANCH CIRCUIT CONDUIT AND WIRE GENERALLY SURFACE MOUNTED, CONCEALED ABOVE CEILINGS THE CONTRACTOR SHALL PROVIDE THE REQUIRED CONDUCTORS UNDER THE CONTRACT SUM WHETHER PHOTOCELL ON ROOF J FLUSH MOUNTED JUNCTION BOX ( SURFACE IN MECH/ELEC SPACES OR ABOVE CEILINGS). F/T FIT FLOW INDICATOR TRANSMITTER (TOTALIZER) FSH FSL FLOW SWITCH HIGH/LOW LLS FS LIQUID LEVEL SWITCH NEUTRAL CONDUCTOR. GREEN GROUND CONDUCTOR NOT SHOWN; ALL CONDUITS REQUIRE COPPER GROUND CONDUCTOR. TWO CONDUCTORS PLUS GROUND REQUIRED, MINIMUM. L/T LIT LEVEL INDICATOR TRANSMITTER CONDUIT AND WIRE CONCEALED IN FLOOR SLAB OR UNDERGROUND. LS LIMIT SWITCH OR LEVEL SWITCH BRANCH CIRCUIT PANELBOARD M MOTOR SWITCH MANUAL 45 MOTOR STARTER PRESSURE GAUGE PFT PROCESS FLOW TIMER PS PRESSURE SWITCH TS TEMPERATURE SWITCH TR TIMING RELAY SURGE SUPPRESSION DEVICE SV SOLENOID VALVE VS VIBRATION SWITCH AS NOTED; SEE PANEL SCHEDULES GFI GROUND FAULT INTERRUPTER W TRANSFORMER, SIZE AS INDICATED ALARM INDICATING LIGHT R RUN INDICATING LIGHT FUSE SERVING MOTOR LOADS OF 10HP OR GREATER AND FOR ALL MOTOR LOADS SERVED THROUGH CAPACITOR DRAW-OUT CIRCUIT BREAKER COMBINATION MAGNETIC MOTOR STARTER PROVIDED BY ELECTRICAL U.N.O. MOULDED CASE CIRCUIT BREAKER HP MOTOR CONNECTION TYPICAL STARTER CONTROL. SEE SWITCHGEAR CONTROL DIAGRAMS FOR EXACT TYPE. MOV MOTOR OPERATED VALVE CONNECTION NO ELECTRIC A.C. MOTOR, NO. INDICATES HORSEPOWER. HP AIR HANDLING UNIT CONNECTION; PROVIDE FUSED DISCONNECT AS REQUIRED BY EQUIPMENT NAMEPLATE; MAKE CONNECTIONS. NO ELECTRIC D.C. MOTOR, NO. INDICATES HORSEPOWER. NON-FUSIBLE DISCONNECT SWITCH, 30A,3P UNLESS OTHERWISE INDICATED. LIGHTING FIXURES SYMBOLS MOMENTARY BREAK PUSHBUTTON OR RESET MAINTAINED CONTACT ON-OFF SWITCH FLUORESCENT TROFFER FIXTURE AND CEILING OUTLET BOX START/STOP (S/S) CONTROL SWITCH FLUORESCENT WALL MOUNTED FIXTURE AND OUTLET BOX FUSE FLUORESCENT TROFFER FIXTURE WITH INTEGRAL NICAD EMERGENCY BATTERY PACK. MAINTAINED CONTACT CURRENT TRANSFORMERS EMERGENCY LIGHTING BATTERY PACK FIXTURE; PROVIDE POTENTIAL TRANSFORMERS EXIT LIGHT FIXTURE AND WALL OR CEILING OUTLET BOX (3) COPPERWELD GRD. RODS HID FIXTURE COPPERWELD GRD. ROD POLE MOUNTED SEE DETAIL STAND MOUNTED ARTICULATING ARM DOCK LIGHT RKS Consulting Engineers Electrical, Instrumentation & Control Design HOLE MONTES 15400 Shamrock Dr. Fort Myers, Fl. 33912 P.E. DATE MANUAL OR AUTOMATIC TRANSFER SWITCH (SHADED QUADRANT INDICTES FACE(S) OF FIXTURE) DELTA GROUND ROD LAYOUT KIRK KEY INTERLOCK HID OR INCANDESCENT WALL MOUNTED FIXTURE AND OUTLET BOX UNSWITCHED CIRCUIT TO BATTERY CHARGER. COPPERWELD GRD. ROD MOTOR STRIP HEATER K HID OR INCANDESCENT FIXTURE AND CEILING OUTLET BOX REMOTE TERMINAL BLOCK POINT SHR LIGHTING PANELBOARD FLUORESCENT WALL MOUNTED FIXTURE WITH INTEGRAL NICAD EMERGENCY BATTERY PACK CONTROL POWER TRANSFORMER HAND OFF AUTO CONTROL STATION AS REQUIRED BY ELEMENTARY DIAGRAMS OR SPECS. POWER PANELBOARD MOLDED CASE CIRCUIT BREAKER HAND OFF REMOTE CONTROL STATION NON-FUSIBLE DISCONNECT SWITCH, 30A,3P UNLESS OTHERWISE INDICATED, WITH REMOTE CONTROL STATION FLUORESCENT STRIP FIXTURE AND CEILING OUTLET BOX KEYED SWITCH HOR SERVICE OR EQUIPMENT GROUND. MANUAL TRANSFER SWITCH OR REVERSING SWITCH MOMENTARY CONTACT PUSHBUTTON HOA WATT HOUR METER DISCONNECT SWITCH SIZE PER EQUIPMENT NAME PLATE OR AS NOTED: FOR DISCONNECTS ELECTRIC DUCT HEATER CONNECTION; PROVIDE FUSED DISCONNECT AS REQUIRED BY EQUIPMENT NAMEPLATE; MAKE CONNECTIONS. A NO. LOCAL CONTROL PANEL VARIABLE FREQUENCY DRIVES; PROVIDE SURGE SUPPRESSION DEVICE EQUAL TO SQ.-D. SP3650 ZERO SPEED SWITCH Certificate of Authorization #8212 CP OR EQUAL AT DISCONNECT. TORQUE SWITCH K POWER FACTOR METER NORMALLY CLOSED, TIMED TO CLOSE CONTACT ANALYZER INDICATOR TRANSMITTER ZS PF KW AIT YSH VOLTMETER WALL OUTLET BOX AND 20 AMP GFCI RECEPTACLE MOUNTED 48"AFF OR AS NOTED. NORMALLY OPEN, TIMED TO OPEN CONTACT S/S V NORMALLY CLOSED, TIMED TO OPEN CONTACT P/G ELECTRICAL SYMBOLS LEGEND & DRAWING INDEX ELECTRICAL GENERAL NOTES SCHEDULE SLUDGE CONVEYOR SYSTEM RELOCATION POWER PLAN ELECTRICAL DETAILS INDICATES WEATHERPROOF COVER PLATE. NORMALLY OPEN, TIMED TO CLOSE CONTACT MS E1 E2 E3 ED1 SINGLE LINE DIAGRAM SYMBOLS WALL OUTLET BOX AND 20 AMP GFCI DUPLEX RECEPTACLE AT 18" TO CENTERLINE. WP TEMPERATURE SWITCH, NORMALLY CLOSED K:\CCUD NCWRF Operational Readiness Projects\Operational Readiness\Conveyor Mods\E1.dwg Plotted: May 19, 2011 - 12:58pm by tracy LIGHTNING PROTECTION AIR TERMINAL STREAMER RETARDING TYPE. WALL OUTLET BOX AND 20 AMP DUPLEX RECEPTACLE 18" TO CENTERLINE FLOW SWITCH, NORMALLY CLOSED PE #62427 SYSTEMS CABINET AS NOTED OR MARKED. DRAWING INDEX STREAMER RETARDING AIR TERMINAL MOUNTED TO LIGHT POLE. SP FLOW SWITCH, NORMALLY OPEN TRACY PROKOPETZ SYSTEM SYMBOL LEGEND REVISIONS BY ENGINEERS PLANNERS SURVEYORS LANDSCAPE ARCHITECTS 950 Encore Way Naples, FL. 34110 Phone: (239) 254-2000 Florida Certificate of Authorization No.1772 DESIGN BY: T.M.P. DRAWN BY: T.M.P. CHECKED BY: T.M.P. CAD FILE: E1.dwg NORTH COUNTY WATER RECLAMATION FACILITY OPERATIONAL READINESS PROJECT PROJECT NO. : 2010.075 DATE : ELECTRICAL SYMBOLS LEGEND & DRAWING INDEX 05/11 SHEET NO. : E1 ELECTRICAL GENERAL NOTES 1. DO NOT SCALE THE ELECTRICAL DRAWINGS. REFER TO THE MECHANICAL AND STRUCTURAL DRAWINGS AND APPROVED MANUFACTURER'S SHOP DRAWINGS FOR THE EXACT LOCATION OF ALL EQUIPMENT. LOCATIONS OF EXISTING FACILITIES. 23. REFER TO SITE SURVEY DRAWINGS FOR EXACT 2. ALL WORK SHALL COMPLY WITH THE NATIONAL ELECTRICAL CODE, NATIONAL ELECTRICAL SAFETY CODE, UTILITY REQUIRMENTS AND LOCAL CODES. 3. PROVIDE SCHEDULE 40 PVC CONDUIT BELOW GRADE IN CONCRETE ENCASED DUCT BANKS. PROVIDE SCHEDULE 80 PVC CONDUIT BELOW GRADE IN NON-ENCASED DUCT BANKS. CONTROLLERS AND SERVICE POINTS. IDENTIFICATION SHALL MATCH PANELBOARD SCHEDULES, MCC SECTION, I&C SHOP DRAWINGS & SCHEDULES & TAG LISTS, ETC. 24. 4. CONDUCTORS SHALL NOT BE SPLICED WITHOUT WRITTEN PERMISSION FROM ENGINEER. 5. FURNISH AND INSTALL A #2 TINNED BARE COPPER COUNTERPOISE WIRE ABOVE ALL 6. ALL DISCONNECTS, J-BOXES, TERMINAL CABINETS, ETC. & MOUNTING HARDWARE SHALL 7. ALL CONDUITS (POWER, CONTROL, INSTRUMENTATION, ETC.) SHALL HAVE EQUIPMENT 8. PROVIDE CONCRETE REINFORCED ENCASEMENT OF ALL DUCT BANKS INCLUDING 9. DO NOT ABANDON ELECTRICAL IN PLACE. REMOVE CONDUCTORS BACK TO PANEL/MCC. 25. FROM THE DESIGNED FACILITIES, THE CONTRACTOR SHALL REDESIGN THE FACILITIES AND SUBMIT THE REVISED DESIGN FOR THE ENGINEER'S APPROVAL AT NO ADDITIONAL COST TO THE OWNER. PRIOR TO ELECTRICAL SUBMITTAL THE CONTRACTOR SHALL VERIFY ALL SUPPLIED BREAKER SIZES, STARTER SIZES, OVERLOAD SIZES, ETC. FOR ALL SYSTEMS SUCH AS HVAC, EXHAUST FANS, CHEMICAL PUMPS ETC. AND MODIFY BREAKERS, OVERLOADS, ETC. IN CONTRACTOR SUPPLIED EQUIPMENT BE NEMA 4X STAINLESS STEEL UNLESS NOTED OTHERWISE. GROUNDING CONDUCTOR SIZED PER TABLE 250.122 OF THE N.E.C. ACCORDINGLY. 26. DUCTBANKS UNDER STRUCTURES; TYPICAL. 27. THE ELECTRICAL CONTRACTOR SHALL VERIFY ALL INSTRUMENT/CONTROL EQUIPMENT 28. LOCATIONS WITH THE MECHANICAL DRAWINGS AND THE CONTROLS CONTRACTOR PRIOR TO ROUGH-IN. LOCATIONS SHOWN ON DRAWING ARE APPROXIMATE ONLY. THE ELECTRICAL 11. DOCUMENT COORDINATION TO THE GENERAL ALL WIRE INTO AND OUT OF CONTROL CABINETS SHALL BE TYPE TC CONTROL CABLE WITH MULTIPLE CONDUCTORS, #14 STRANDED WIRE AS SPECIFIED; TYPICAL 29. 30. THROUGHOUT. 12. ALL WIRE INTO AND OUT OF INSTRUMENTATION CABINETS SHALL BE TYPE TC TWISTED SHIELDED INSTRUMENT CABLE WITH MULTIPLE CONDUCTOR PAIRS OF #16 STRANDED WIRE AS SPECIFIED; TYPICAL THROUGHOUT K:\CCUD NCWRF Operational Readiness Projects\Operational Readiness\Conveyor Mods\E2.dwg Plotted: May 19, 2011 - 12:57pm by tracy 13. DURING CONSTRUCTION. REQUIREMENTS. SEE MECHANICAL DRAWINGS FOR EXACT ROUTING AND ELEVATIONS OF DUCTBANKS. 15. ALL CONDUCTORS SHALL BE ROUTED IN AND OUT OF MANHOLES TAKING THE DISTANCE TO ALLOW FOR SLACK CABLE. LONGEST 16. ALL CONTROL PANELS SHALL BE CONSTRUCTED BY A UL508A APPROVED PANEL VENDOR AND SHALL BEAR A UL508A LABEL ON THE PANEL. 17. DRAWINGS DO NOT SHOW EXACT ROUTING OF CONDUIT. COORDINATE CONDUIT LOCATIONS WITH OTHER TRADES SO THAT CONFLICTS ARE AVOIDED. 18. LOCATIONS OF MANHOLES, HANDHOLES AND PULL BOXES ARE APPROXIMATE. 19. PROVIDE A #2 BOND FROM ALL FIELD INSTRUMENTS, MOTORS, CONTROL PANELS, 20. PROVIDE 2' MINIMUM DISTANCE BETWEEN PARALLEL RUNS OF LOW VOLTAGE 480V & CONTRACTOR SHALL COORDINATE EXACT LOCATION WITH EXISTING AND PROPOSED PIPING AND OTHER INTERFERENCES. TERMINATION CABINETS, ETC TO THE GROUND GRID. 120V POWER CONDUITS AND I&C CONDUITS. POWER CONDUIT SHALL CROSS INSTRUMENTATION CONDUIT PERPENDICULARLY AT RIGHT ANGLES WITH 6" MINIMUM SEPARATION FOR 480V & 120V. VFD MOTOR LEAD CONDUIT SHALL HAVE 24" NON-DESTRUCTIVE IMAGING METHODS (RADAR, XRAY) TO LOCATE EMBEDDED CONDUIT IN CONCRETE PRIOR TO DEMOLITION, SAW CUTTING AND CORE COORDINATE WITH G.C. THE REQUIRED TEMPORARY 14. IT IS THE CONTRACTOR'S RESPONSIBILITIES TO USE DRILLING. RELOCATE AND RECONSTRUCT AFFECTED CONDUIT AND WIRE PER ELECTRICAL SPECIFICATIONS. 31. SEPARATION TO INSTRUMENTATION & CONTROL CONDUITS. 21. CONDUCTOR PULLING TENSIONS SHALL NOT EXCEED MANUFACTURER'S RECOMMENDATION. 22. PLAN DRAWINGS DO NOT SHOW ALL CONDUITS REQUIRED. PROVIDE ADDITIONAL CONDUIT CONTRACTOR SHALL INSTALL PULL BOXES TO MEET MANUFACTURER'S REQUIREMENTS. FOR CONDUCTORS AS SHOWN ON RISER, ONE-LINE DIAGRAMS, DETAILS AND NOTES. RKS Electrical, Instrumentation & Control Design HOLE MONTES 15400 Shamrock Dr. Fort Myers, Fl. 33912 TRACY PROKOPETZ PE #62427 P.E. Certificate of Authorization #8212 NO. DATE REVISIONS BY ENGINEERS PLANNERS SURVEYORS LANDSCAPE ARCHITECTS 950 Encore Way Naples, FL. 34110 Phone: (239) 254-2000 Florida Certificate of Authorization No.1772 DESIGN BY: T.M.P. DRAWN BY: T.M.P. CHECKED BY: T.M.P. CAD FILE: E2.dwg GROUNDING CONNECTIONS BELOW GRADE SHALL BE EXOTHERMIC UNLESS SPECIFICALLY INDICATED OTHERWISE. ALL ENCLOSURES, TERMINAL CABINETS, WIREWAYS, PULL BOXES ETC. SHALL CONTAIN A GROUNDING BUS BAR. CONNECT ALL RACEWAY BONDS TO BUS BAR VIA GROUNDING BUSHING AND EXTEND BONDING JUMPER FROM BUS BAR TO ENCLOSURE. CONTRACTOR SHALL CORE DRILL EXISTING CONCRETE WALLS, FLOORS, MANHOLES, HANDHOLES AND PULL BOXES FOR CONDUIT 32. ALL CONDUITS PENETRATING RATED FIRE WALLS OR RATED FIRE FLOORS SHALL BE INSTALLED WITH U.L. APPROVED DEVICES TO MAINTAIN THE FIRE RATING OF THE WALL OR FLOOR PENETRATED. 33. PROVIDE CONDUIT DUCT SEAL AT ALL CONDUIT ENDS. 34. ALL SPARE CONDUITS SHALL BE SEALED WITH A CAP AT BOTH ENDS AND A PULL STRING INSTALLED WITH IDENTIFICATION ON BOTH ENDS. 35. FLEXIBLE CONDUITS SHALL BE USED TO TERMINATE ALL MOTORS AND OTHER VIBRATING EQUIPMENT & SHALL BE A MAXIMUM OF 24" IN LENGTH. 36. PROVIDE TYPEWRITTEN PANEL SCHEDULES IN PANELBOARD & TYPEWRITTEN TERMINAL BLOCK SCHEDULES IN TERMINAL CABINETS; PROPOSED & MODIFIED. 37. 38. 39. 40. 41. 42. Consulting Engineers PROVIDE COLORED WARNING TAPE 6" WIDE SHALL BE INSTALLED 12" BELOW FINISHED GRADE DIRECTLY ABOVE ALL UNDERGROUND PENETRATIONS. SEAL PENETRATIONS WITH NON GROUT OR APPROPRIATE FIRE RATED DEVICES WHERE APPLICABLE. THE SEQUENCE OF CONSTRUCTION WILL REQUIRE TEMPORARY ELECTRICAL SERVICES BE PROVIDED TO ALL AFFECTED FACILITIES TO MAINTAIN CONTINUOUS OPERATION MINIMUM DEPTH FROM TOP OF DUCTBANKS OR CONDUITS TO FINISHED GRADE SHALL BE 30" UNLESS OTHERWISE NOTED. YARD CONDUITS. CONTRACTOR SHALL VERIFY ALL CONTROL CABLING REQUIRED WITH THE CONTROLS CONTRACTOR PRIOR TO ROUGH-IN. CONTRACTOR PRIOR TO ROUGH-IN. ALL EXCAVATIONS FOR CONDUITS, HANDHOLES, MANHOLES AND PULLBOXES NEAR EXISTING PIPING, CONDUIT AND EQUIPMENT SHALL BE HAND EXCAVATED AND COORDINATED WITH ENGINEER. REMOVE CONDUIT BACK TO FIRST MANHOLE, HANDHOLE OR REUSE FOR NEW WORK. IF NOT BEING REUSED. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CONDUIT AND WIRING INSTALLATION FOR ALL VENDOR PROVIDED EQUIPMENT (PACKAGE SYSTEMS). IF THE SHOP DRAWINGS DIFFER CONDUITS IN DUCT BANKS, BONDED TO BUILDING COUNTERPOISE AT BOTH ENDS. REMOVE COMPLETE DUCT BANK AND MANHOLES 10. THE EXPOSED RUNS OF CONDUITS SHALL BE INSTALLED WITH RUNS PARALLEL OR PERPENDICULAR TO WALLS, STRUCTURAL MEMBERS OR INTERSECTIONS OF VERTICAL PLANES AND CEILINGS, WITH RIGHT ANGLE TURNS CONSISTING OF SYMMETRICAL BENDS OR PULL BOXES AS INDICATED ON THE DRAWINGS. BENDS AND OFFSETS SHALL BE AVOIDED WHERE POSSIBLE. MAJOR DUCT BANKS AS INDICATED, MINOR DUCT BANKS AS DIRECTED BY ENGINEER IN FIELD. PROVIDE BELL END CONDUIT IN MANHOLES AND AT STUBUP LOCATIONS. ALL U.G. PROCESS RELATED CONDUIT SHALL BE PROTECTED IN CONCRETE ENCASEMENT. ALL CIRCUITS SHALL BE IDENTIFIED IN JUNCTION BOXES, PULL BOXES, CONTROL PANELS, PANELBOARDS, LIGHTING POLES, PROVIDE 1/2"=1' SCALE ELECTRICAL ROOM/AREA LAYOUT DRAWING SUBMITTAL, SHOWING ALL ELECTRICAL EQUIPMENT. 20AMP LIGHTING AND RECEPTACLE BRANCH CIRCUITS EXCEEDING 75 FT IN LENGTH SHALL BE A MINIMUM #10 AWG WIRE. ALL EXTERIOR DISCONNECTS, J-BOXES, TERMINAL CABINETS, ETC. & MOUNTING HARDWARE SHALL BE NEMA 4X STAINLESS STEEL UNLESS NOTED OTHERWISE. PROVIDE CONCRETE REINFORCED ENCASEMENT OF ALL DUCT BANKS. COMPLY WITH NEC REQUIREMENTS FOR HAZARDOUS AREAS AS DEFINED BY NFPA-820 STANDARDS FOR FIRE PROTECTION IN WASTEWATER TREATMENT AND COLLECTION FACILITIES CURRENT EDITION. COMPLY WITH THE NEC REQUIREMENTS FOR HAZARDOUS AREAS AS DEFINED BY NFPA-820 STANDARDS FOR FIRE PROTECTION IN WASTEWATER TREATMENT AND COLLECTION FACILITIES CURRENT EDITION. NORTH COUNTY WATER RECLAMATION FACILITY OPERATIONAL READINESS PROJECT PROJECT NO. : 2010.075 DATE : GENERAL ELECTRICAL NOTES 05/11 SHEET NO. : E2 6' UP TO PANEL EDCCP 6' 0 3/32"=1'-0" 7 KEYNOTES # 1. 5 J TO BE REMOVED 6 EXISTING EAST CONVEYOR TO BE ROTATED 180 DEGREES. ALL ASSOCIATED ELECTRICAL AND 10 15 INSTRUMENT CONNECTIONS REQUIRED TO BE RELOCATED WHETHER SPECIFICALLY SHOWN OR NOT. 2. EXISTING EAST CONVEYOR LOCAL DISCONNECT TO REMAIN. EXISTING ZERO SPEED SWITCH TO BE RELOCATED. 4. EXISTING SURVEILLANCE CAMERA TO BE RELOCATED. 5. EXISTING SURVEILLANCE CAMERA JUNCTION BOX TO REMAIN. 6. REROUTE EXISTING CONDUIT AND WIRE TO 13 K:\CCUD NCWRF Operational Readiness Projects\Operational Readiness\Conveyor Mods\E3.dwg Plotted: May 19, 2011 - 2:35pm by tracy EXISTING H2S ANALYZER ELEMENT TO BE RELOCATED. 12. PROPOSED AUTO LUBRICATION STATION. CONNECTION 6"-DRN MCC-7A 3 LP7C - MCC 8A/B C - MCC 7B LOWER LEVEL PLAN PULL IN NEW WIRE FROM EXISTING DISCONNECT TO RELOCATED MOTOR. MATCH EXISTING WIRE TYPE AND SIZE. 11. 2 LP7B CONDUIT TO PROPOSED EQUIPMENT LOCATION. EXISTING CONDUIT WIRE AND EQUIPMENT TO 4 FD RELOCATED. 10. 9 8 4 8 LP7D PULL IN COAX VIDEO CABLE FROM EXISTING JUNCTION BOX TO RELOCATED CAMERA. MATCH EXISTING CABLE TYPE. INTERCEPT EXISTING CONDUIT AND PROVIDE NEW ZS 6 FD CONDUIT TO PROPOSED EQUIPMENT LOCATION. 9. 7.5 TO BE ROTATED 180 DEGREES AIT INTERCEPT EXISTING CONDUIT AND PROVIDE NEW PROPOSED LOCATION OF EXISTING EQUIPMENT 1 3 8 DRILL REQUIRED. REMOVE 8. AE UP TO UPPER LEVEL CORE UNUSED CONDUIT SUPPORTS FROM STRUCTURE. PATCH AND PAINT. 7. ZS 11 AE 8 3. PROPOSED EQUIPMENT LOCATION. 16 8 7.5 6 EXISTING EAST DISTRIBUTION CONVEYOR CONTROL REMAIN. PANEL (EDCCP) COORDINATE EXACT CONNECTION REQUIREMENTS WITH SUBMITTAL PRIOR TO ROUGH-IN. 13. 14. 15. PROVIDE 20A, 1P BREAKER IN EXISTING M PANEL. MATCH EXISTING MANUFACTURER AND BREAKER TYPE FOR SERVICE TO AUTO LUBRICATION UNIT. FHP SUSPEND PROPOSED CONDUIT FROM EXISTING STRUCTURE WITH STAINLESS STEEL ALL-THREAD AND UNISTRUT. AVOID STAIRS WHEN COMING DOWN TO MAKE CONNECTION TO AUTO LUBE SYSTEM. 12 14 INTERCEPT EXISTING CONDUIT AND PROVIDE NEW CONDUIT TO PROPOSED EQUIPMENT LOCATION. PULL IN NEW CABLE FROM EXISTING EAST DISTRIBUTION CONVEYOR CONTROL PANEL(EDCCP) TO RELOCATED ZERO SPEED SWITCH. EXISTING CABLE TYPE. 16. MATCH INTERCEPT EXISTING CONDUIT AND PROVIDE NEW DN TO PNL LP7D CONDUIT TO PROPOSED EQUIPMENT LOCATION. PULL IN NEW INSTRUMENT CABLE FROM EXISTING ANALYZER TRANSMITTER TO RELOCATED ANALYZER ELEMENT. MATCH EXISTING CABLE TYPE. GENERAL NOTES: EXTEND, REROUTE, RECONNECT, REPAIR EXISTING 1. EQUIPMENT BONDS TO PROPOSED EQUIPMENT LOCATIONS. = DEMO COMPLETE UPPER LEVEL PLAN RKS Consulting Engineers Electrical, Instrumentation & Control Design HOLE MONTES 15400 Shamrock Dr. Fort Myers, Fl. 33912 TRACY PROKOPETZ PE #62427 P.E. Certificate of Authorization #8212 NO. DATE REVISIONS BY ENGINEERS PLANNERS SURVEYORS LANDSCAPE ARCHITECTS 950 Encore Way Naples, FL. 34110 Phone: (239) 254-2000 Florida Certificate of Authorization No.1772 DESIGN BY: T.M.P. DRAWN BY: T.M.P. CHECKED BY: T.M.P. CAD FILE: E3.dwg NORTH COUNTY WATER RECLAMATION FACILITY OPERATIONAL READINESS PROJECT PROJECT NO. : 2010.075 DATE : SLUDGE CONVEYOR SYSTEM RELOCATION POWER PLAN 05/11 SHEET NO. : E3 STEEL OR CONCRETE CONDUIT COVER THIS PORTION WITH SHRINK TUBING 5" MIN. 12" MAX. SIZE AS REQUIRED WRAPPED SHIELD GREEN INSULATED WIRE AWG 18 CRIMPED SPLICE CONNECTOR COVER THIS PORTION WITH SHRINK TUBING AS REQUIRED SINGLE RACK SHIELD SHRINK TUBING 5" MIN. 12" MAX. SIGNAL LEADS LUG. TYPICAL GROUND LEAD CONDUIT SIZE AS REQUIRED OUTER JACKET SHRINK TUBING NOTE: SHIELD GROUNDED AT TERMINATION CONDUIT SIZE AS STAINLESS STEEL HARDWARE TYP OUTER JACKET SHIELD CONCRETE OR STEEL 5" MIN. 12" MAX. OUTER JACKET REQUIRED TERMINATION OF SHIELDED INSTRUMENT & CONTROL CABLE N.T.S. DOUBLE RACK CONDUIT RACKING SYSTEMS FEEDER OR BRANCH CONDUCTOR BRASS OR STAINLESS DISK N.T.S. BUILDING WALL W/STAMPED IDENTIFICATION LB CONDULETS 1/8" DIA. 50-50 SOLDER WIRE OR NYLON TIE STRAP FINISH GRADE U.G. CABLE TAG DETAIL 2'-0" K:\CCUD NCWRF Operational Readiness Projects\Operational Readiness\Conveyor Mods\ED1.dwg Plotted: May 19, 2011 - 12:54pm by tracy MIN. N.T.S. CONDUIT ENTRANCE TO EXISTING FACILITY N.T.S. CONDUIT SHALL BE GROUNDED WITH INSULATED GROUNDING BUSHINGS SIZE AND NUMBER AS REQUIRED STEEL CONDUIT GROUND WIRE CONDUIT GROUNDING DETAIL N.T.S. RKS Consulting Engineers Electrical, Instrumentation & Control Design HOLE MONTES 15400 Shamrock Dr. Fort Myers, Fl. 33912 TRACY PROKOPETZ PE #62427 P.E. Certificate of Authorization #8212 NO. DATE REVISIONS BY ENGINEERS PLANNERS SURVEYORS LANDSCAPE ARCHITECTS 950 Encore Way Naples, FL. 34110 Phone: (239) 254-2000 Florida Certificate of Authorization No.1772 DESIGN BY: T.M.P. DRAWN BY: T.M.P. CHECKED BY: T.M.P. CAD FILE: ED1.dwg NORTH COUNTY WATER RECLAMATION FACILITY OPERATIONAL READINESS PROJECT PROJECT NO. : 2010.075 DATE : ELECTRICAL DETAILS 05/11 SHEET NO. : ED1
© Copyright 2024