TRB sample cooler TRB Sample cooler For Low Pressure Boiler Applications Compact, efficient sample cooling for industrial boiler samples Features Description Helical coil design The TRB sample cooler is a compact sample cooler that provides the industrial boiler user with a cost effective and efficient sampling alternative. It’s small profile allows for easy installation on or near the boiler. Optimal service for flows below 1200 cc/min for single phase heat transfer. Standard tube side material is 300 series stainless steel. Ideal for cooling low pressure boiler water Performance Curve - Water Model TRB-4222 su re (P S 5 I) 10 40 30 op 0 oF 20 Dr 15 10 (1 49 o C) 10 20 30 0o F 20 15 oF 200 5 1 PSI = 0.069 Bar es Pressure Drop (PSI) Pr Approach Temperature (oC) Approach Temperature (oF) 40 pl e ) m 0 (20 4 oC 25 Sa 500 o F ( 260 o C 50 ) Surface Area 1.2 Ft.2 [0.11 m2] 3 GPM [11.4 L/min] Cooling Water at 95oF [35oC] 1 PSI [0.07 Bar] Pressure Drop NOTE: Not recommended for steam condensing service. See TLR, FLR, FXR series sample coolers for this application. o C) (9 3 . Temp Inlet o ) o (66 C 150 F 25 0 30 400 600 0.1 800 0.2 60 80 1000 1200 CCM 1400 0.3 GPM 1600 0.4 1800 2000 0.5 100 120 140 160 180 200 220 240 260 280 Lbm/Hr Flow Rate www.sentry-equip.com 4.1 Rev. 7 09/13 1 3/32” [28mm] 1 15/32” [37mm] 15/32” [12mm] 3/8” FNPT Cooling Water Inlet 1 9/32” [33mm] 3/8” FNPT Cooling Water Outlet 1 25/32” [45mm] 3 9/16” [90mm] Square 21/64” [8mm] Sample Inlet 1/4” O.D. Tube Sample Outlet 1/4” O.D. Tube 4” [102mm] Mounting Bracket (Supplied with each cooler) 3” [76mm] 2 1/4” [57mm] 5/16” [8mm] 2” [51mm] 1 1/4” [32mm] 5 1/2” [140mm] 3 13/16” [97mm] 3/8” FNPT Drain Specifications – TRB TubeShellPart Model No.Shell Design Tube DesignMaterialMaterialArea Weight Number TRB-4222 250 psi @ 450ºF 2000 psi @ 850ºF 300 Series SS 304 SS 1.2 ft2 9 lbs 7-00016A 17 bar @ 232ºC 137 bar @ 454ºC 1/4"O.D. x 0.049" AW 0.11m2 4 kg It is solely the responsibility of the end-user, through its own analysis and testing, to select products and materials suitable for their specific application requirements, ensure they are properly installed, safely applied, properly maintained, and limit their use to their intended purpose. Improper selection, installation, or use may result in personal injury or property damage. SENTRY EQUIPMENT CORP For further information, contact: 966 Blue Ribbon Circle North Oconomowoc, WI 53066 USA Tel: 262-567-7256 • Fax: 262-567-4523 E-mail: [email protected] Website: www.sentry-equip.com © Sentry Equipment Corp 2006 4.1 Rev. 7 09/13
© Copyright 2024