Rx Reveal Report 888-214-8444 586 New York Ave. Huntington, NY 11743

Rx Reveal Report
888-214-8444
586 New York Ave. Huntington, NY 11743
Specimen Id:
Accession:
Control #:
Donor ID:
Name:
DOB:
Order Type:
RX Drugs Taken:
4384
14692, 14691
123456
1234
Doe, John
Dec 25, 1983
PM/Urine
Oxycontin, Xanax
SAMPLE
Agency: NYC PAIN Management
Date Collected:
Test Date:
Jun 21, 2010 9:15 AM
Jun 21, 2010 9:21 AM
19/3
Test
Result
Amphetamine (EIA)
Benzodiazepine (EIA)
----- A-Hydroxyalprazolam
(GCMS)
Negative (Screen)
POSITIVE (Screen)
457 ng/mL
Flag
Reference Range
500 ng/mL
200 ng/mL
25 ng/mL
Rx Reveal
Specimen is positive for A-hydroxyalprazolam. This is consistent with the medication history provided (Xanax).
----- Lorazepam (GCMS)
----- Nordiazepam (GCMS)
----- Oxazepam (GCMS)
Buprenorphine (EIA)
Cannabinoids (EIA)
Cocaine Metabolite (EIA)
Heroin Metabolite (EIA)
Opiate 300 (EIA)
----- Hydrocodone (GCMS)
Negative (Confirm)
Negative (Confirm)
Negative (Confirm)
Negative (Screen)
Negative (Screen)
Negative (Screen)
Negative (Screen)
POSITIVE (Screen)
782 ng/mL
100 ng/mL
25ng/mL
25 ng/mL
5 ng/mL
50 ng/mL
150 ng/mL
10 ng/mL
300 ng/mL
50 ng/mL
Rx Reveal
Specimen is positive for hydrocodone. This is INCONSISTENT with medication history provided.
Oxycodone (EIA)
----- Oxycodone (GCMS)
POSITIVE (Screen)
687 ng/mL
100 ng/mL
10 ng/mL
Rx Reveal
Specimen is positive for oxycodone. This is consistent with the medication history provided (Oxycontin).
----- Oxymorphone (GCMS)
987 ng/mL
10 ng/mL
Rx Reveal
Specimen is positive for oxymorphone. This is consistent with the medication history provided (Oxycontin).
Tramadol (EIA)
Creatinine (EIA)
Negative (Screen)
145.0 mg/dL
Normal
200 ng/mL
Normal: >20 mg/dL
Validity Test
Oxidants (EIA)
Normal
50 ug/mL
Validity Test
pH (EIA)
7.00
Normal
Validity Test
FINAL REPORT
Normal: 4.50 - 8.99
Final Report - Page: 2
Specimen Id: 4384
Laboratory Director: Richard Stripp Ph.D.
All drug screens are performed by immunoassay.
All drug confirmations are performed by gas chromatography/mass spectrometry (GC/MS)or liquid
chromatography tandem mass spectrometry (LC/MS/MS).
Immunoassays provide only a preliminary analytical test result. A more specific alternative chemical method must
be used to obtain a confirmed analytical result. Gas chromatography/mass spectrometry (GC/MS)or liquid
chromatography tandem mass spectrometry (LC/MS/MS)are the preferred confirmatory methods.
Validity testing ensures that submitted specimens are unadulterated and/or within normal human physiological
parameters. Specimens which fail validity testing are considered invalid. Physicians should use discretion when
interpreting analytical results.
Richard Stripp Ph.D
FINAL REPORT