Service Manual Hot Runner Controllers HR & HRD Rev. 1.00.02 02/2014 Translation of original Service Manual PSG Plastic Service GmbH Service Manual Hot Runner Controllers HR & HRD Table of Contents 1 1.1 Typographical Conventions ............................................................................................................... 2 Additional and continuative documents ................................................................................................ 2 2 2.1 2.1.1 2.1.2 2.1.3 2.2 2.3 2.3.1 2.3.2 System Configuration ......................................................................................................................... 3 Components ........................................................................................................................................... 3 Main board .............................................................................................................................................. 3 Power supply card.................................................................................................................................. 3 Power controller card STP6 / STP6 II ................................................................................................... 4 Schematic presentation ......................................................................................................................... 5 Setup....................................................................................................................................................... 6 DIP switch 1 to 3 - Addressing .............................................................................................................. 6 DIP switch 4 – Deactivate phase synchronization ............................................................................... 6 3 Status LED's ......................................................................................................................................... 7 4 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 Messages on LED Display.................................................................................................................. 8 Message E100 – Identification of malfunction of power controller card at system start..................... 8 Message E101 – Identification of malfunction of power controller card at system start..................... 8 Message E102 - Identification of change in system configuration ...................................................... 9 Message E103 – Identification of short circuit ...................................................................................... 9 Message E104 – Version incorrect on power controller card .............................................................. 9 Message E110…114 – Timeout of interface to power controller card .............................................. 10 Message E115 – Timeout of interface to power supply card............................................................. 10 Message E120…E124 – Error phase synchronization ...................................................................... 11 Message E130…E134 - EEPROM error ............................................................................................ 12 Message E140…E144 - Temperature alarm ..................................................................................... 12 Message E150…E154 - Potential error .............................................................................................. 12 5 5.1 Appendix ............................................................................................................................................. 13 Version History ..................................................................................................................................... 13 Right to technical changes reserved Rev. 1.00.02 1 PSG Plastic Service GmbH Service Manual Hot Runner Controllers HR & HRD 1 Typographical Conventions Symbols and conventions are used in this manual for faster orientation for you. Caution Note 1.1 With this symbol, references and information are displayed which are decisive for the operation of the device. In case of non-compliance with or inaccurate compliance there can result damage to the device or injuries to persons. The symbol refers to additional information and declarations, which serve for improved understanding. Example With the symbol, a function is explained by means of an example. Reference With this symbol, information in another document is referred to. FAQ Here FAQ (Frequently Asked Questions) are answered. Equations Calculation specifications and examples are represented in this way. Additional and continuative documents Operation See operating instructions hot runner controllers HR/HRD Input by interface See project planning - and configuration tool WinKonVis Right to technical changes reserved Rev. 1.00.02 2 PSG Plastic Service GmbH Service Manual Hot Runner Controllers HR & HRD 2 System Configuration 2.1 Components The hot runner controller consists of the components: main board power supply card power controller card STP6 (HR 12…30) / STP6 II (HRD 06…30) power supply card/power controller card STP6H (HR 06) 2.1.1 Main board Includes: Micro Controller and peripherals Keys (membrane keypad) LED displays Interface RS485 Interface CAN Digital inputs/-outputs The functions are: temperature control communication with the connected power controller cards communication with superior control IO handling (alarms, etc) system monitoring 2.1.2 Power supply card Includes: Micro Controller and peripherals Interface RS485 The functions are: the identification of voltage zero crossing for network synchronous output of actuating signal (only HR) control of fan Right to technical changes reserved Rev. 1.00.02 3 PSG Plastic Service GmbH Service Manual Hot Runner Controllers HR & HRD 2.1.3 Power controller card STP6 / STP6 II Includes: Micro Controller and peripherals Status LED's Interface RS485 Analog inputs for temperature registration complete power controller units (thyristor, fuse) for control of electric heaters The functions are: communication with main board measured value recording output of actuating signals identification of residual current the identification of voltage zero crossing for network synchronous output of actuating signal (only HRD) Right to technical changes reserved Rev. 1.00.02 4 PSG Plastic Service GmbH Service Manual Hot Runner Controllers HR & HRD 2.2 Schematic presentation Hot runner controller HR 06 RS485 Power supply card Main board CAN RS485 Power controller card I/O ~ Hot runner controller HR 12, HR 18, HR 24, HR 30 ... RS485 Main board CAN RS485 Power supply card I/O Power controller card ... Power controller card ~ Hot runner controller HRD 06…30 ... RS485 Standard Power supply Main board CAN RS485 I/O Power controller card ... Power controller card ~ Right to technical changes reserved Rev. 1.00.02 5 PSG Plastic Service GmbH Service Manual Hot Runner Controllers HR & HRD 2.3 Setup Each card (power supply card and power controller card) is identified uniquely by check sum. As default the setup data is on the main board. Thereby system errors/defects can immediately and clearly be identified and remedied. A setup must be executed after each system change (e.g. replacement of cards) (Enter code number 5 by membrane keypad or interface, procedure see corresponding manuals chapter 1.1). 2.3.1 DIP switch 1 to 3 - Addressing The cards are sequentially addressed starting with 0, view from the front side from the left to the right. The address is stipulated by DIP1…DIP3. DIP switch Card number 1 1 2 3 4 ON 2 1 2 3 4 ON 3 1 2 3 4 ON 4 1 2 3 4 ON 5 1 2 3 4 ON 2.3.2 DIP switch 4 – Deactivate phase synchronization The exact identification of zero crossing can for example not be guarantied at operation in "instable" networks. Therefore the phase synchronization can be deactivated by DIP switch. DIP switch Phase synchronization Active 1 2 3 4 ON Deactive 1 2 3 4 ON Right to technical changes reserved Rev. 1.00.02 6 PSG Plastic Service GmbH Service Manual Hot Runner Controllers HR & HRD 3 Status LED's Due to a self diagnosis, that is executed by the hot runner controller directly after switch on, all display segments are activated to test them. On the cards of the hot runner controller are LEDs, which are only visible after opening of the cover of the hot runner controller. The opening of the cover of the hot runner controller may be carried out by authorized persons only. Only skilled and on the risks trained persons may use the device. The relevant accidental regulations as well as other general approved safety-relevant, occupational-medical norms have to be obeyed. Before opening of the device always switch-off the mains switch and unplug the mains plug or make sure that the device is de-energized. Protect against unintentional reclosing. OK-LED (yellow*) SIO-LED (yellow) Flashing = Boot Continuous light = OK Flashing = Boot Continuous light = OK Power supply card Power controller card STP6H Flashing = Interface operation Flashing = Interface operation *) STP6II OK-LED (green) LEDs at relay (yellow) Power controller card STP6 Power controller card STP6 II Continuous light = Relay switched Flashing = Output percentage Continuous light = Relay switched Flashing = Output percentage Power supply card Power controller card STP6H ... Power controller card STP6 Power controller card STP6 II Right to technical changes reserved Rev. 1.00.02 7 PSG Plastic Service GmbH Service Manual Hot Runner Controllers HR & HRD 4 Messages on LED Display 4.1 Message E100 – Identification of malfunction of power controller card at system start The cards plugged in the hot runner controller are sequentially addressed from 0 (see chapter 2.3.1) as defined in the setup (see chapter 2.3) by default. Is a gap detected, e.g. by identification of a malfunction of a power controller card (not the one, with the highest address), the message alternates with the display HR??. Hot runner controller ≥ HR 12, ≥ HRD 12 Reason Phase missing Incorrect plug connection Start Trouble Shooting Incorrect addressing Power controller card electrical defect 4.2 Operating status Check mains voltage before fuses Check connection to ribbon cable Replace ribbon cable if necessary Check DIP switch setting (see chapter 2.3.1) Check LEDs on power controller card (see chapter 3) Replace power controller card or send hot runner controller in for repair Message E101 – Identification of malfunction of power controller card at system start Is detected that, opposite to the default setup (see chapter 2.3) a malfunction of the power controller card with the highest address has occurred cards were added or removed the message alternates with the display HRXX. By pressing the key h again, a new SCAN can be activated and the new configuration can be transferred. Hot runner controller > HR 06, > HRD 06 Reason Phase missing Incorrect plug connection Incorrect addressing Power controller card electrical defect Operating status Start Trouble Shooting Check mains voltage before fuses Check connection to ribbon cable Replace ribbon cable if necessary Check DIP switch setting (see chapter 2.3.1) Check LEDs on power controller card (see chapter 3) Replace power controller card or send hot runner controller in for repair Right to technical changes reserved Rev. 1.00.02 8 PSG Plastic Service GmbH Service Manual Hot Runner Controllers HR & HRD 4.3 Message E102 - Identification of change in system configuration The message is displayed, when a changed system configuration is detected, e.g. by replacement of a power controller card. In case this is no error, by pressing the key h again, a new SCAN can be activated and the new configuration can be transferred. Hot runner controller ≥ HR 06, ≥ HRD 06 Reason Changed DIP switch 4.4 Start/Operation Trouble Shooting Check DIP switch setting (see chapter 2.3.1) Message E103 – Identification of short circuit Hot runner controller ≥ HRD 06 Reason Ground fault Sensor at heating output 4.5 Operating status Operating status Start heating Trouble Shooting Check heating Check wiring Message E104 – Version incorrect on power controller card Hot runner controller ≥ HRD 06 Reason Old firmware version on power controller card Operating status Start Trouble Shooting Replace power controller card Firmware update by manufacturer necessary, send power controller card or hot runner controller in for repair Right to technical changes reserved Rev. 1.00.02 9 PSG Plastic Service GmbH Service Manual Hot Runner Controllers HR & HRD 4.6 Message E110…114 – Timeout of interface to power controller card E110 matches timeout on card 1, E111 matches timeout on card 2, etc. Hot runner controller ≥ HR 06, ≥ HRD 06 Reason Incorrect plug connection Operation Trouble Shooting Loose connection DIP switch Power controller card electrical defect 4.7 Operating status Check connection to ribbon cable Replace ribbon cable if necessary Replace power controller card or send hot runner controller in for repair Replace power controller card or send hot runner controller in for repair Message E115 – Timeout of interface to power supply card Hot runner controller ≥ HR 06, ≥ HRD 06 Reason Incorrect plug connection Power supply card electrical defect Operating status Operation Trouble Shooting Check connection to ribbon cable Replace ribbon cable if necessary Replace power supply card or send hot runner controller in for repair Right to technical changes reserved Rev. 1.00.02 10 PSG Plastic Service GmbH Service Manual Hot Runner Controllers HR & HRD 4.8 Message E120…E124 – Error phase synchronization E120 matches error on card 1, E121 matches error on card 2, etc. Hot runner controller = HR 06 Reason Phase missing Fuse defective Hot runner controller Reason Phase missing Fuse defective Operating status Start/Operation Trouble Shooting ≥ HR 12 Check mains voltage before fuses Check fuse on power supply card Replace power supply card or send hot runner controller in for repair Operating status Start/Operation Trouble Shooting Check mains voltage before fuses Check fuse on power supply card, replace if necessary Right to technical changes reserved Rev. 1.00.02 11 PSG Plastic Service GmbH Service Manual Hot Runner Controllers HR & HRD Hot runner controller ≥ HRD 06 Reason Phase missing Fuse defective 4.9 Operating status Start/Operation Trouble Shooting Check mains voltage before fuses At least one of the zone fuses is defective, check and replace if necessary (see fuse holder/side of housing) Message E130…E134 - EEPROM error E130 matches error on card 1, E131 matches error on card 2, etc. Hot runner controller ≥ HR 06, ≥ HRD 06 Reason Defect EEPROM or check sum error in EEPROM 4.10 Operating status Start/Operation Trouble Shooting Replace power controller card or send hot runner controller in for repair Message E140…E144 - Temperature alarm E140 matches error on card 1, E141 matches error on card 2, etc. The heat sink temperature has exceeded 80 °C. All outputs on the power controller card are switched off. Output of alarm message current tolerance. Hot runner controller ≥ HR 06, ≥ HRD 06 Reason High temperature at installation location Overload 4.11 Operation Trouble Shooting Mechanical defect of fan Operating status Check environmental conditions at installation location Check, that the power controller card is operated only with 50% duty ratio at full load for all 6 channels Check fan and clean if necessary Message E150…E154 - Potential error E150 matches error on card 1, E151 matches error on card 2, etc. Hot runner controller ≥ HRD 06 Reason Voltage on measurement input Operating status Operation Trouble Shooting Check wiring Right to technical changes reserved Rev. 1.00.02 12 PSG Plastic Service GmbH Service Manual Hot Runner Controllers HR & HRD 5 Appendix 5.1 Version History Version Date Changes 1.00.02 1.00.01 1.00.00 02-20-2014 04-16-2010 11-09-2009 DIP Switch phase synchronisation inverted Complete revision First publication E120…E124 PSG Plastic Service GmbH Pirnaer Straße 12-16 68309 Mannheim Germany Tel. +49 621 7162 0 Fax +49 621 7162 162 www.psg-online.de [email protected] Right to technical changes reserved Rev. 1.00.02 13
© Copyright 2024