Instruction Manual CSM722 CENTRIFUGAL SIFTER Pos : 2 /00 Titel/Vors pann/Symbole leer @ 4\mod_1321290256517_0.doc @ 23702 @ @ 1 Pos : 3 /00 Titel/Vors pann/Symbole Ex @ 4\mod_1321290266064_0.doc @ 23716 @ @ 1 Pos : 5 /00 Tit el/Vors pann/Symbole Ex und CE @ 4\mod_1321284810200_0.doc @ 23647 @ @ 1 Pos : 6 /00 Titel/Vors pann/Titelbil der/Misc her/Titelbil d GM S ECD mit Ei nlaufdec kel ohne T üren @ 4\mod_1336986946069_0.doc @ 26890 @ @ 1 === Ende der Liste für T extmar ke TitPict === Pos : 8 /00 Titel/Vors pann/Adresse & Identifi kati on (mi t F abri kati ons nummer) Geric ke AG R egens dorf @ 4 \mod_1321284484374_968.doc @ 23640 @ @ 1 Gericke Limited, Victoria House, Cavendish Street, Ashton-under-Lyne, Lancashire. OL6 7DJ Tel +44 (0)161 344 1140 www.gericke.net Pos : 9 /00 Titel/Vors pann/C opyright Geric ke AG R egens dorf 2011 @ 1\mod_1295877155121_968.doc @ 4355 @ @ 1 Order number: PTI003990 Fabrication number: M22320 Doc-ID:JULY 2014 Release:JULY2014 Issue date: JULY 2014 Copyright Copyright © Gericke Ltd. This manual is copyright and intended exclusively for internal use. Access to the manual by third parties, reproduction in any form – including in part – and use and/or distribution of the content is not permitted without the written approval of the manufacturer. Violations of the above will be liable for compensation for damages. We reserve the right to make additional claims. === Ende der Liste für T extmar ke Intro === Page 2 of 101 Instruction Manual CSM722 SIFTER Order numberPTI003990-M22320, Doc-ID: APH 20-11-13 Content 1.1 General............................................................................... 6 1.1.1 About this manual ..................................................... 6 1.1.2 Explanation of symbols ............................................ 7 1.1.2.1 Safety instructions ....................................... 7 1.1.2.2 Safety instructions for specific dangers ....... 8 1.1.2.3 Tips and recommendations ......................... 8 1.1.3 Limitation of liability ................................................... 8 1.1.4 Spare parts ............................................................... 9 1.1.5 Customer service ...................................................... 9 1.2 Description of Device ....................................................... 10 1.2.1 Purpose .................................................................. 10 1.2.2 Designated use ....................................................... 11 1.2.3 Manufacturer........................................................... 12 1.2.4 Conformity .............................................................. 12 1.2.5 Marking ................................................................... 13 1.2.5.1 Nameplate ................................................. 13 1.2 Safety ................................................................................ 15 1.3.1 Responsibility of the operator .................................. 15 1.3.2 Personnel requirements .......................................... 17 1.3.2.1 Qualifications............................................. 17 1.3.2.2 Unauthorised persons ............................... 18 1.3.3 Personal protective equipment ................................ 18 1.3.4 General dangers ..................................................... 19 1.3.6 Signage .................................................................. 23 1.3.7 Safety equipment .................................................... 23 1.3.7.1 Emergency stop equipment ....................... 23 1.3.8 Lock to prevent restart ............................................ 23 1.3.9.1 Action in case of danger and accidents ................... 25 1.3.10 Environmental protection ........................................ 25 1.4 Transport, Packing and Storage ..................................... 25 1.4.1 Safety instructions for transport............................... 26 1.4.2 Transport inspection ............................................... 27 1.4.3 Transport ................................................................ 27 1.4.4 Packaging ............................................................... 29 1.4.5 Storage ................................................................... 29 1.5 Installation ........................................................................ 30 1.5.1 Safety instructions for installation ............................ 30 1.5.2 Requirements at the installation location ................. 30 1.5.3 Checks before installation ....................................... 31 1.5.4 Installing device ...................................................... 32 1.5.5 Installing product inlet and outlet ............................. 32 1.5.6 Connecting device .................................................. 33 1.5.6.1 Connecting drive ....................................... 33 1.6 Initial Commissioning ...................................................... 34 1.6.1 Safety instructions for initial commissioning ............ 34 Instruction Manual CSM722 SIFTER Order number: PTI003990-M22320, Doc-ID: APH 20-11-13 Page 3 of 101 Content 1.6.2 Test run................................................................... 35 1.6.2.1 Before the test run ..................................... 35 1.6.2.2 Test run without product ............................ 35 1.6.2.3 Test run with product ................................. 36 1.6.2.4 Set limit values for air purge seal ............... 36 1.7 Operation .......................................................................... 37 1.7.1 Safety instructions for operation .............................. 37 1.7.2 Operation ................................................................ 37 1.8 Malfunctions ..................................................................... 38 1.8.1 Safety instructions for troubleshooting .................... 38 1.8.2 Troubleshooting table.............................................. 40 1.8.3 After correction of malfunctions ............................... 42 1.9 Maintenance and Repair .................................................. 43 1.9.1 Safety instructions for maintenance and repair........ 43 1.9.2 Maintenance schedule ............................................ 44 1.9.2.1 Maintenance schedule............................... 45 1.9.3 Maintenance ........................................................... 45 1.9.3.1 Cleaning .................................................... 46 1.9.4 Actions after maintenance or repair......................... 47 1.10 Disassembly and Disposal ................................... 47 1.10.1 Safety instructions for disassembly and disposal .... 48 1.11 Appendix ............................................................... 48 1.11.1 Checklist for test run ............................................... 48 1.11.2 Associated documents ............................................ 49 Page 4 of 101 2 Technical Data .................................................................. 51 2.1 Performance ........................................................... 51 2.2 Connection values .................................................. 51 2.3 Product ................................................................... 52 2.4 Emissions ............................................................... 52 2.5 Lubricant ................................................................. 52 2.6 Operating conditions ............................................... 52 3 Data Sheet and Sectional Arrangement .......................... 54 3.1 Dimensions and weight ........................................... 56 4 Basket Assembly.............................................................. 58 4.1 Operation ................................................................ 59 4.2 Basket removal and assembly ................................ 61 4.2.1 Set sieve hose on basket rings .................. 61 5 Door Assembly (End) ....................................................... 64 5.1 Operation ................................................................ 65 5.2 Removal of guards (non-drive end) ......................... 66 5.3 Removal of end door ............................................... 66 5.4 Removal of non-drive end bearing .......................... 66 Instruction Manual CSM722 SIFTER Order numberPTI003990-M22320, Doc-ID: APH 20-11-13 Content 6 Door Assembly (Side) ...................................................... 68 6.1 Operation ................................................................ 69 7 Drive Assembly ................................................................ 70 7.1 Operation ................................................................ 71 7.2 Removal of drive end bearing ................................. 72 7.3 Guards .................................................................... 72 7.4 Installation instruction for synchronous belt drive .... 73 7.5 Pulley alignment ..................................................... 73 7.6 Taperlock Bush ....................................................... 74 8 Seal Assembly .................................................................. 76 8.1 Seals....................................................................... 77 9 Shaft Assembly ................................................................ 78 9.1 Removal of shaft assembly ..................................... 80 9.2 Shaft assembly and drive ........................................ 80 10 Additional Features .......................................................... 82 11 Certification ...................................................................... 84 12 Spares List ........................................................................ 86 13 Service Contract ............................................................... 88 14 Proprietary Equipment ..................................................... 93 14.1 Safety switches ....................................................... 95 14.2 Motor instructions.................................................... 97 15 Gericke contact addresses .............................................. 99 Instruction Manual CSM722 SIFTER Order number: PTI003990-M22320, Doc-ID: APH 20-11-13 Page 5 of 101 1.1 General Pos : 11.1 /01 Allgemein/Allgemei nes --nur Titel-- @ 0\mod_1275377354296_968.doc @ 973 @ 1 @ 1 1.1 General Pos : 11.2 /01 Allgemein/Original anl eitung gemäss MRL @ 0\mod_1275377461062_968.doc @ 974 @ @ 1 Original instruction manual This document is an ORIGINAL INSTRUCTION MANUAL as defined by the EC Machinery Directive 2006/42/EC. Pos : 11.3 /01 Allgemein/Infor mationen zu di es er Anlei tung --nur Titel-- @ 0\mod_1275462597843_968.doc @ 977 @ 2 @ 1 1.1.1 About this manual Pos : 11.4 /01 Allgemein/Infor mationen zu di es er Anlei tung @ 0 \mod_1275462870921_968.doc @ 978 @ @ 1 The operating instructions must be read and observed. A fundamental requirement for safe working and trouble-free operation of this device is knowledge of safety regulations and observance of warnings. This manual is essential for safe and efficient working with the device. The manual is a component of the device and must be kept with the device so it is accessible for operators at all times. Operators must have carefully read and understood this manual before starting to work with the device. A fundamental requirement for safe working is compliance with all specified safety instructions and work instructions in this manual. The local accident prevention regulations and general safety regulations for the area of operation of the device must also be observed. Illustrations in this manual are provided for basic understanding and may deviate from the actual design of the device. Supplier documentation The manuals for the OEM components are also applicable in addition to this manual. The instructions in those manuals, particularly safety instructions, must be observed at all times. The materials processed by the device are referred to as "product" or "bulk material" in this operating manual. Pos : 11.5 /--Seitenumbr uch-- @ 0\mod_1275315941062_0.doc @ 1348 @ @ 1 Page 6 of 101 Instruction Manual CSM722 SIFTER Order numberPTI003990-M22320, Doc-ID: APH 20-11-13 1.1 General Pos : 11.6 /01 Allgemein/Symbol er klär ung --nur Titel-- @ 0\mod_1275898810921_968.doc @ 1321 @ 2 @ 1 1.1.2 Explanation of symbols Pos : 11.7 /01 Allgemein/Sic her heitshi nweis e --nur Titel-- @ 0\mod_1275463066375_968.doc @ 979 @ 3 @ 1 1.1.2.1 Safety instructions Pos : 11.8 /01 Allgemein/Symbol er klär ung @ 0\mod_1275463216703_968.doc @ 980 @ @ 1 Safety instructions in this manual are indicated by symbols. The safety instructions are introduced by signal words that indicate the degree of the hazard. Safety instructions must be observed at all times and caution is required to prevent accidents, injuries and property damage. DANGER … indicates an immediate hazardous situation that may result in death or serious injury if it is not prevented. WARNING ... indicates a possible hazardous situation that may result in death or serious injury if it is not prevented. CAUTION ... indicates a possible hazardous situation that may result in minor or slight injury if it is not prevented. CAUTION ... indicates a possible hazardous situation that may result in property damage if it is not prevented. Pos : 11.9 /--Seitenumbr uch-- @ 0\mod_1275315941062_0.doc @ 1348 @ @ 1 Instruction Manual CSM722 SIFTER Order number: PTI003990-M22320, Doc-ID: APH 20-11-13 Page 7 of 101 1.1 General Pos : 11.10 /01 Allgemei n/Sicherheits hinweis e für bes ondere Gefahr en @ 0\mod_1275322386937_968.doc @ 972 @ 3 @ 1 1.1.2.2 Safety instructions for specific dangers Special symbols are integrated in safety instructions to draw attention to specific dangers. Pos : 11.11 /01 Allgemei n/Elektrischer Strom ( GEF AHR) @ 0 \mod_1275463458640_968.doc @ 981 @ 4 @ 1 1.1.2.2.1 Danger from electrical current DANGER Danger of death from electrical current ... indicates a life-threatening situation from electrical current. There is a danger of serious injury or death if the safety instructions are not observed. Pos : 11.12 /01 Allgemei n/Ti pps und Empfehlungen @ 0 \mod_1275464408875_968.doc @ 984 @ 3 @ 1 1.1.2.3 Tips and recommendations NOTE ... emphasises useful tips and recommendations with information on efficient and trouble-free operation. Pos : 12.1 /01 AllgemeinExpl osi onss chutz , Konz ept (Ex) AT EX @ 0\mod_1275464236687_968.doc @ 982 @ 4 @ 1 Pos : 13.1 /01 Allgemein/H aftungsbesc hränkung -- nur Ti tel-- @ 0\mod_1275464467250_968.doc @ 985 @ 2 @ 1 1.1.3 Limitation of liability Pos : 13.2 /01 Allgemein/H aftungsbesc hränkung @ 0\mod_1275464528875_968.doc @ 986 @ @ 1 All statements and instructions in this manual are compiled with reference to applicable standards and regulations, the state of the art in technology and our many years of knowledge and experience. The manufacturer does not accept liability for damage resulting from: not following the manual non-designated use placement and processing of bulk material for which the device is not designed appointment of untrained operators unauthorised conversions technical modifications use of non-approved spare parts The actual scope of delivery may vary from the descriptions and explanations in this manual for special models, additional of optional orders or recent technical changes. The obligations specified in the supply contract, the general terms of business and the manufacturer's terms of supply and the legal regulations applicable at the time of the contract apply. Pos : 13.3 /--Seitenumbr uch-- @ 0\mod_1275315941062_0.doc @ 1348 @ @ 1 Page 8 of 101 Instruction Manual CSM722 SIFTER Order numberPTI003990-M22320, Doc-ID: APH 20-11-13 1.1 General Pos : 13.4 /01 Allgemein/Ersatzteile --nur Titel-- @ 0\mod_1275464584046_968.doc @ 987 @ 2 @ 1 1.1.4 Spare parts Pos : 13.5 /01 Allgemein/Ersatzteile, Ers atz teilliste ( WARNUNG, HIN WEIS) @ 0\mod_1275464649093_968.doc @ 988 @ @ 1 WARNING Safety risk from incorrect spare parts! Incorrect or faulty spare parts may adversely affect safety and cause damage, malfunction or total failure. Use only original spare parts supplied by the manufacturer. Order spare parts from an authorised dealer or directly from the manufacturer. See title page for address. Spare parts list NOTE The spare parts list is included in this manual. It can be ordered from Gericke Ltd. if required. Pos : 13.6 /01 Allgemein/Kundendienst --nur Titel-- @ 0\mod_1275464693718_968.doc @ 989 @ 2 @ 1 1.1.5 Customer service Pos : 13.7 /01 Allgemein/Kundendienst @ 0\mod_1275464756281_968.doc @ 990 @ @ 1 Please contact our customer service for technical information. See title page for address. Our employees are also always interested in new information and experience derived from everyday use that could be useful for improving our products. Instruction Manual CSM722 SIFTER Order number: PTI003990-M22320, Doc-ID: APH 20-11-13 Page 9 of 101 Description of Device Pos : 14.1 /02 Gerätebes chr eibung/Ger ätebesc hrei bung --nur Titel-- @ 0\mod_1275464852718_968.doc @ 991 @ 1 @ 1 1.2 Description of Device Pos : 14.2 /02 Gerätebes chr eibung/Ver wendungsz wec k --nur Titel-- @ 0\mod_1275464894359_968.doc @ 992 @ 2 @ 1 1.2.1 Purpose Pos : 14.3 /02 Gerätebes chr eibung/Misc her/Ver wendungsz wec k C harg en, AT EX @ 0 \mod_1275464950328_968.doc @ 993 @ @ 1 The device is designed for integration into a system. The device is designed for sieving of bulk material. . Pos : 15 /02 Gerätebes chr eibung/Misc her/Ver wendungsz wec k Ger äteübersicht GM S ECD mit Ei nlaufdec kel @ 4\mod_1320070556979_968.doc @ 22817 @ @ 1 Fig. 1: Device overview Page 10 of 101 Instruction Manual CSM722 SIFTER Order numberPTI003990-M22320, Doc-ID: APH 20-11-13 Description of Device Pos : 16.1 /02 Gerätebes chr eibung/Bestgem. Ver wendung --nur Titel-- @ 0\mod_1275465127937_968.doc @ 995 @ 2 @ 1 1.2.2 Designated use Pos : 16.2 /02 Gerätebes chr eibung/Misc her/Bestg em. Ver wendung @ 1\mod_1293613404114_968.doc @ 3181 @ @ 1 The device is designed and constructed exclusively for designated purpose described above. The device must be used exclusively for sieving bulk material that conforms to the product properties stated in "Technical Data". The device must be operated exclusively in accordance with the operating and environmental conditions stated in "Technical Data". Bulk materials with properties other than those specified in "Technical Data" may be processed only with prior approval in writing by Gericke Ltd. The sifter is to be integrated into the safety design of the complete system (risk assessment for the entire system performed by the installer of the complete system or the operating company is required). The operator is responsible for compliance with the basic safety and health protection requirements during operation of the system. Pos : 17.1 /02 Gerätebes chr eibung/Misc her/Bestg em. Ver wendung, nic ht monti erter Produkteinl auf ( WARNUN G) @ 1 \mod_1293176196869_968.doc @ 2990 @ @ 1 Operation forbidden with open product inlet, product outlet or other open spigots WARNING Operating without mounted product inlet or outlet or if other spigots (e.g. aspiration spigots) are not connected or are not closed, contact may result with the feed worm if the operator reaches into these openings. This may cause serious injury or death. Never operate the device without an installed product inlet and outlet. Likewise, other available spigots must be connected or properly sealed. Pos : 17.2 /02 Gerätebes chr eibung/Bestgem. Ver wendung, nicht besti mmungsgemäss ( WARNUN G) @ 0 \mod_1275465559625_968.doc @ 999 @ @ 1 WARNING Danger resulting from non-designated use Any use of the device not in conformity with the designated use and/or use for other purposes may result in hazardous situations. Pos : 17.3 /02 Gerätebes chr eibung/Bestgem. Ver wendung, H aftungsaussc hluss @ 0\mod_1275465665218_968.doc @ 1000 @ @ 1 Claims of any type for damage resulting from non-designated use will not be accepted. The operator bears sole responsibility for any damage resulting from non-designated use. Pos : 17.4 /--Seitenumbr uch-- @ 0\mod_1275315941062_0.doc @ 1348 @ 2 @ 1 Instruction Manual CSM722 SIFTER Order number: PTI003990-M22320, Doc-ID: APH 20-11-13 Page 11 of 101 Description of Device Pos : 17.5 /02 Gerätebes chr eibung/H ersteller --nur Titel-- @ 0\mod_1275465739390_968.doc @ 1001 @ 2 @ 1 1.2.3 Manufacturer Pos : 17.6 /02 Gerätebes chr eibung/H ersteller Adr ess e Geric ke AG Regens dorf @ 0 \mod_1275465789437_968.doc @ 1002 @ @ 1 Gericke Ltd. Victoria House, Cavendish Street Ashton-under-Lyne, Lancashire OL6 7DJ England. Pos : 18.1 /02 Gerätebes chr eibung/Konfor mität --nur Titel-- @ 0\mod_1275465870765_968.doc @ 1003 @ 2 @ 1 1.2.4 Conformity Pos : 18.2 /02 Gerätebes chr eibung/Konfor mität MR L ohne C E @ 4 \mod_1338976352889_968.doc @ 27099 @ @ 1 The device conforms to the safety and health-protection requirements of the following European Directives: 2006/42/EC Machinery Directive Pos : 19.1 /02 Gerätebes chr eibung/Konfor mität --nur Titel-- @ 0\mod_1275465870765_968.doc @ 1003 @ 2 @ 1 Page 12 of 101 Instruction Manual CSM722 SIFTER Order numberPTI003990-M22320, Doc-ID: APH 20-11-13 Description of Device Pos : 22 /02 Gerätebes chr eibung/Kennz eichnung --nur Titel-- @ 0\mod_1275465986609_968.doc @ 1005 @ 33 @ 1 1.2.5 Marking Pos : 23 /02 Gerätebes chr eibung/T ypenschil d Allgemei n @ 0\mod_1275466038593_968.doc @ 1006 @ 3 @ 1 1.2.5.1 Nameplate A nameplate with the following information is installed on the device: Pos : 24 /02 Gerätebes chr eibung/T ypenschil d ATEX, mi t CE Geric ke AG --Bil d-- @ 0\mod_1275466090859_968.doc @ 1007 @ 3 @ 1 1 2 3 4 Fig. 2: Nameplate 1 2 3 4 Manufacturer, address Type Fabrication number Year of manufacture 25 /02 Gerätebes chr eibung/T ypenschil d, Gericke AG Bil d @ 4\mod_1320074889613_968.doc @ 22880 @ @ 1 Pos : 28 /02 Gerätebes chr eibung/Misc her/T ypensc hild Anbri ngungsort GMS @ 4\mod_1307605483903_968.doc @ 12200 @ @ 1 Installation location nameplate The nameplate (1) is on the casing. Pos : 29 /02 Gerätebes chr eibung/T ypenschil d, weitere T ypensc hilder @ 0 \mod_1275466212875_968.doc @ 1009 @ @ 1 Fig. 3: Installation location nameplate Instruction Manual CSM722 SIFTER Order number: PTI003990-M22320, Doc-ID: APH 20-11-13 Page 13 of 101 Description of Device NOTE Additional nameplates are on components attached to the device. Note the information on the nameplates. Pos : 30.1 /02 Gerätebes chr eibung Ex-Kennz eichnung, Geräte ohne ATEX-CE Kennz eic hnung @ 1\mod_1290182131056_968.doc @ 2535 @ 3 @ 1 Pos : 32.1 /02 Gerätebes chr eibung Ex-Kennz eichnung, Geräte ohne ATEX-CE Kennz eic hnung @ 1\mod_1290182131056_968.doc @ 2535 @ 3 @ 1 Page 14 of 101 Instruction Manual CSM722 SIFTER Order numberPTI003990-M22320, Doc-ID: APH 20-11-13 Safety Pos : 33.1 /03 Sic her heit/Sic herheit --nur Titel-- @ 0\mod_1275466470546_968.doc @ 1012 @ 1 @ 1 1.2 Safety Pos : 33.2 /03 Sic her heit/Sic herheit @ 0\mod_1275466626468_968.doc @ 1013 @ 2 @ 1 This section contains an overview of all important aspects of safety for optimum protection of operators and for safe and trouble-free operation. Non-observance of the operating and safety instructions in this manual may result in serious hazards. Pos : 33.3 /03 Sic her heit/Verantwortung des Betreibers -- nur Ti tel-- @ 0\mod_1275466678578_968.doc @ 1014 @ 2 @ 1 1.3.1 Responsibility of the operator Pos : 33.4 /03 Sic her heit/Verantwortung des Betreibers, allgemeine R egel n @ 0 \mod_1275466772234_968.doc @ 1015 @ 3 @ 1 The device is designed for commercial use. The operator of the device is therefore subject to the legal obligations for occupational health and safety. In addition to the occupational health and safety instructions in this manual the applicable safety, accident prevention and environmental protection regulations must be observed. General rules The operator must be familiar with the applicable occupational health and safety regulations and must conduct a risk assessment to determine additional hazards that may arise in the specific working conditions at the installation location of the device. The risk assessment must be implemented in the form of work instructions for operation of the device. Throughout the total operating time of device the operator must check that the work instructions conform to the current status of the regulations and must modify the instructions if necessary. The operator must clearly regulate and define the responsibilities for installation, operation, maintenance and cleaning. The operator must ensure that all employees who work with the device have read and understood this manual. Operators must also undergo training at regular intervals and must be informed of possible dangers. Pos : 33.5 /03 Sic her heit/Verantwortung des Betreibers, Installati on @ 0 \mod_1275466854015_968.doc @ 1016 @ @ 1 On installation The operator must provide a suitable base with sufficient stability for the device. The operator must fit all product inlets and outlets on the device with suitable protection against hazardous access during operation in accordance with the regulations and directives applicable at the operation location. Pos : 33.6 /03 Sic her heit/Verantwortung des Betreibers, Versc hiedenes @ 0\mod_1275467006031_968.doc @ 1017 @ 2 @ 1 Instruction Manual CSM722 SIFTER Order number: PTI003990-M22320, Doc-ID: APH 20-11-13 Page 15 of 101 Safety The operator must implement suitable measures (product in feed monitoring) to ensure that the bulk material does not contain foreign bodies. An example of this could be a magnet fitted to the in-feed to the sifter to remove ferrous contaminants. The operator must conduct noise measurement to determine the sound pressure level during operation. Depending on the result the operator may be required to specify hearing protection for operators. The operator must provide a central earth for the device and must clearly mark the earth. The operator must take suitable precautions to the prevent product blockage. Pos : 33.7 /03 Sic her heit/Verantwortung des Betreibers, ei nwandfrei er Z ustand @ 0\mod_1275467154968_968.doc @ 1018 @ @ 1 Technically correct status The operator is responsible for ensuring that the device is always maintained in a technically correct status. The operator must ensure that the maintenance intervals defined in this manual are observed or adjusted in accordance with the actual load on the device. The operator must ensure that all safety equipment is regularly checked for function and completeness. Pos : 33.8 /03 Sic her heit/Verantwortung des Betreibers, Pr ozessgas @ 0\mod_1275467225531_968.doc @ 1019 @ 3 @ 1 Process gas The operator must check whether and to what extent the process gas presents a health hazard, including by contamination with product dust, and if applicable implement suitable measures to prevent damage to health. The operator must ensure that the bulk material conforms to the properties defined in "Technical Data" and that the characteristics of the bulk material do not represent an increased risk of ignition. Pos : 33.9 /03 Sic her heit/AT EX, Ver antwortung des Betrei bers, Schüttgut @ 0\mod_1275467282046_968.doc @ 1020 @ 3 @ 1 Bulk material Pos : 34.1 /03 Sic her heitAT EX, Verpflichtung Betr eiber ExSc hutz ( EX) @ 0\mod_1275467356859_968.doc @ 1021 @ 22 @ 1 Page 16 of 101 Instruction Manual CSM722 SIFTER Order numberPTI003990-M22320, Doc-ID: APH 20-11-13 Safety Pos : 35.1 /03 Sic her heit/Pers onalanforderungen --nur Titel-- @ 0\mod_1275467419406_968.doc @ 1022 @ 2 @ 1 1.3.2 Personnel requirements Pos : 35.2 /03 Sic her heit/Pers onalanforderungen @ 0\mod_1275467465671_968.doc @ 1023 @ 33 @ 1 Only personnel who can be expected to perform their work reliably are permitted to operate the device. Persons whose reaction capacity is affected, e.g. by drugs, alcohol or medications, are not permitted. When selecting operators note the age and qualification regulations applicable for location. The minimum age for employees working on and with the device is 18. Pos : 35.3 /03 Sic her heit/Qualifi kationen @ 0\mod_1275467548578_968.doc @ 1024 @ 33 @ 1 1.3.2.1 Qualifications Improper working with the device may cause serious personal injury and property damage. All activities must be carried out by qualified personnel only. The instruction manual defines the following qualifications for various activities: Trained persons have been trained by the operator to carry out their assigned duties and to recognise the potential hazards of incorrect actions. Technicians have the technical education, knowledge and experience along with awareness of the relevant regulations to enable them to carry out their assigned tasks and to recognise and avoid potential hazards. Electrical technicians have the technical education, knowledge and experience along with awareness of the relevant standards and regulations to enable them to be authorised to work on electrical installations and to recognise and avoid potential hazards. Pneumatic technicians have the technical education, knowledge and experience along with awareness of the relevant standards and regulations to enable them to be authorised to work on pneumatic installations and to recognise and avoid potential hazards. Pos : 35.4 /--Seitenumbr uch-- @ 0\mod_1275315941062_0.doc @ 1348 @ 22 @ 1 Instruction Manual CSM722 SIFTER Order number: PTI003990-M22320, Doc-ID: APH 20-11-13 Page 17 of 101 Safety Pos : 35.5 /03 Sic her heit/Unbefugte @ 0\mod_1275467593968_968.doc @ 1025 @ 33 @ 1 1.3.2.2 Unauthorised persons Unauthorised persons who do not conform to the above requirements are not aware of the hazards in the work area. Unauthorised persons must not be permitted access to the work area. In case of doubt speak to persons and direct them away from the work area. Stop all work while unauthorised persons are in the work area. Pos : 35.6 /03 Sic her heit/Pers önlic he Sc hutz ausrüstung --nur Titel-- @ 0\mod_1275467782734_968.doc @ 1026 @ 2 @ 1 1.3.3 Personal protective equipment Pos : 35.7 /03 Sic her heit/Pers önlic he Sc hutz ausrüstung @ 0\mod_1275467879750_968.doc @ 1027 @ @ 1 Personal protective equipment must be worn during work to minimise health hazards. The protective equipment required for the specific task must be worn at all times during work. Instructions for personal protective equipment in the work area must be observed. Basic requirements Always wear the following for all work: Protective work clothing Closely fitted work clothing with low tear resistance, close-fitting sleeves and no projecting parts. It is designed primarily as protection from being caught by moving machine parts. Do not wear rings, chains and other jewellery. Do not wear long hair open. Safety shoes For protection from falling heavy parts and slipping on slippery surfaces. Wear the following for specific tasks Special personal protective equipment is required for specific tasks. This is described in other sections of this manual. Special personal protective equipment is described below. Safety glasses For protection of eyes from flying parts and spraying fluids. Safety gloves For protection of hands from friction, abrasion, puncture or deeper wounds and against contact with hot surfaces. Page 18 of 101 Instruction Manual CSM722 SIFTER Order numberPTI003990-M22320, Doc-ID: APH 20-11-13 Safety Safety helmet For protection from falling and flying parts and materials. Hearing protection For protection of hearing if the sound level of the device in operation is high or the operator is exposed to other sound sources. If applicable, the operator must require the use of hearing protection. Additional regulations specified by the operator and local regulations that may require the use of specific personal protective equipment must be observed. Pos : 36.1 /03 Sic her heitAT EX, Schutz ausrüs tung z um Expl osionss chutz (EX) @ 0\mod_1275467981703_968.doc @ 1028 @ 3 @ 1 Pos : 37.1 /03 Sic her heit/Allg. Gefahren -- nur Ti tel-- @ 0\mod_1275468051250_968.doc @ 1029 @ 2 @ 1 1.3.4 General dangers Pos : 37.2 /03 Sic her heit/Allg. Gefahren, Ei nleitung @ 0\mod_1275468108531_968.doc @ 1030 @ @ 1 The following section describes residual risks that have been identified by a risk assessment. Observe the safety instructions and warnings listed in following sections of this manual to reduce dangers and to prevent hazardous situations. Pos : 37.3 /03 Sic her heit/Allg. Gefahren, El ektrizität ( GEF AHR) @ 0 \mod_1275468169093_968.doc @ 1031 @ @ 1 Electrical current DANGER Danger of death from electrical current Contact with live parts is an immediate risk of death. Damaged insulation or individual components may be life-threatening. If damaged insulation is detected switch off the power supply immediately and have the damage repaired. All work on the electrical system must be conducted by electrical technicians only. Before all work switch off power to the electrical system and check that it is disconnected. Before maintenance, cleaning and repairs switch off power supply and lock to prevent unauthorised reactivation. Do not bridge or disable fuses. Always replace fuses with new fuses of the same type. Keep moisture away from live parts. It may cause a short-circuit. Instruction Manual CSM722 SIFTER Order number: PTI003990-M22320, Doc-ID: APH 20-11-13 Page 19 of 101 Safety Pos : 37.4 /03 Sic her heit/Allg. Gefahren, Pneumati k ( WARNUNG) @ 0\mod_1275468220984_968.doc @ 1032 @ @ 1 Pneumatics WARNING Danger of injury by pneumatic energy! Pneumatic energy may cause serious injuries. Pneumatically actuated parts may move unexpectedly. Damage to components may allow air to escape under high pressure and cause injury, e.g. to eyes. All work on the pneumatic system must be conducted by trained technicians only. Before starting work on the pneumatic system de-pressurise the system. Look out for pressure accumulators. Accumulators must also be depressurised. Do not change pressure settings above the maximum values. Pos : 37.5 /03 Sic her heit/Allg. Gefahren, bewegte Bauteil e ( WARNUN G) @ 0 \mod_1275468264062_968.doc @ 1033 @ @ 1 Moving parts WARNING Danger of injury by moving parts! Rotating and/or linear moving parts may cause serious injury. During operation do not reach into moving parts or fiddle with moving parts. Do not open covers during operation. Do not remove or disable safety equipment. Note after-run time: before opening covers make sure that all parts have stopped moving. Wear close-fitting protective clothing. Do not wear hair loose. Pos : 37.6 /--Seitenumbr uch-- @ 0\mod_1275315941062_0.doc @ 1348 @ 2 @ 1 Hot surfaces Page 20 of 101 WARNING Danger of burns from hot surfaces! Contact with hot surfaces may cause burns. Always wear personal protective equipment and safety gloves for all work in the vicinity of hot components. Before all work make sure that all components have cooled to ambient temperature. Instruction Manual CSM722 SIFTER Order numberPTI003990-M22320, Doc-ID: APH 20-11-13 Safety Pos : 37.7 /03 Sic her heit/Allg. Gefahren, heiss e Oberflächen (WARNUN G) @ 0\mod_1275468378437_968.doc @ 1034 @ 2 @ 1 Pos : 37.8 /03 Sic her heit/Allg. Gefahren, sc harfe Kanten (VORSICHT) @ 0\mod_1275468429421_968.doc @ 1035 @ @ 1 Sharp edges and pointed corners CAUTION Danger of injury on edges and corners! Sharp edges and pointed corners may cause abrasions and cuts. Always move cautiously during all work in the vicinity of sharp edges and pointed corners. Wear safety gloves as required. Pos : 37.9 /03 Sic her heit/Allg. Gefahren, heben von Las ten ( VOR SICHT) @ 0\mod_1275468497062_968.doc @ 1036 @ @ 1 Lifting loads CAUTION Danger of injury when lifting loads! Lifting heavy loads may cause personal injury. Observe occupational health and safety regulations. Use suitable lifting gear. If necessary, have a second person help. Pos : 37.10 /03 Sicherheit/Allg. Gefahren, g esundheitsg efähr dende Stoffe (WARNUNG) @ 0\mod_1275468554093_968.doc @ 1037 @ @ 1 Hazardous substances, dust and gas emissions WARNING Danger to health from hazardous substances! The device can be used to process substances or auxiliary and operating substances that may cause damage to health on contact. Before starting any work on the device ask a supervisor what substances have been processed. Wear suitable personal protective equipment if necessary. See the material safety data sheets for the substances. Avoid dust and gas emissions. Keep connections to the device well sealed, check gaskets regularly Pos : 37.11 /03 Sicherheit/Allg. Gefahren, unsachgemäss es Arbeiten ( WARNUN G) @ 0\mod_1275468604765_968.doc @ 1038 @ @ 1 Danger from improper working WARNING Danger of injury from improper working! Observe general occupational health and safety regulations and safe working rules. Before starting work ensure that there is adequate access. Keep workplace clean and orderly. Loosely placed and scattered components and tools are causes of accidents. Secure components to prevent them from dropping or falling. Use ladders and fall protection systems. Instruction Manual CSM722 SIFTER Order number: PTI003990-M22320, Doc-ID: APH 20-11-13 Page 21 of 101 Safety Page 22 of 101 Install components correctly. Observe the specified bolt tightening torques. Instruction Manual CSM722 SIFTER Order numberPTI003990-M22320, Doc-ID: APH 20-11-13 Safety Pos : 38.1 /03 Sic her heit/AT EX, Explosi ons- und Br andgefahr --nur Titel-- @ 0\mod_1275468695390_968.doc @ 1039 @ 2 @ 1 1.3.6 Signage Pos : 39.2 /03 Sic her heit/Besc hilderung, Einl eitung @ 0\mod_1275471379140_968.doc @ 1051 @ 22 @ 1 The following symbols and information signs are on the device. They refer to the immediate area to which they are applied. Pos : 39.3 /03 Sic her heit/Besc hilderung, bewegte T eile @ 0\mod_1275902084390_968.doc @ 1322 @ 33 @ 1 Danger from moving parts Persons reaching into moving parts with this sign may be crushed. or Pos : 39.4 /03 Sic her heit/Besc hilderung, unkenntliche Sc hilder @ 0 \mod_1275471503453_968.doc @ 1052 @ 232 @ 1 Over time decals and signs may become illegible because of dirt or other reasons. Maintain all safety, warning and operating instructions in a clean, legible condition. Replace damaged signs or decals immediately. Pos : 39.5 /03 Sic her heit/Sic herheits einric htungen -- nur Ti tel-- @ 0\mod_1275471597390_968.doc @ 1053 @ 2 @ 1 1.3.7 Safety equipment Pos : 39.6 /03 Sic her heit/Sic herheits einric htungen @ 0\mod_1275471663703_968.doc @ 1054 @ 232 @ 1 The installed safety and monitoring equipment is listed in "Description of subassemblies" in "Structure and Function". Pos : 39.7 /03 Sic her heit/Not-Aus-Ei nrichtungen @ 0\mod_1275471718328_968.doc @ 1055 @ 2232 @ 1 1.3.7.1 Emergency stop equipment The device is integrated into a system and does not have separate emergency stop equipment. The operator must ensure that emergency stop equipment is installed in conformity with the applicable accident prevention regulations. The operator must train operating personnel in the position and function of the emergency stop equipment and must retain proof of training. Pos : 39.8 /03 Sic her heit/Sic hern g egen Wieder einschalten --nur Titel-- @ 0\mod_1275471784093_968.doc @ 1056 @ 23 @ 1 1.3.8 Lock to prevent restart Pos : 39.9 /03 Sic her heit/Sic hern g egen Wieder einschalten @ 0\mod_1275471852468_968.doc @ 1057 @ 2222 @ 1 DANGER Danger of death from unauthorised restart! When working in the danger zone it is possible that unauthorised persons will restore the power supply and the device will start unexpectedly. This is a risk to the life of persons in the danger zone. Note the instructions for locking the device to prevent restart in the various sections of this manual. Always follow the procedure for locking the device to prevent restart described below. Switch locked with padlock on: …………… at …... a.m./p.m. : Lock to prevent restart Instruction Manual CSM722 SIFTER Order number: PTI003990-M22320, Doc-ID: APH 20-11-13 Page 23 of 101 Safety DO NOT SWITCH ON The lock may be removed by: ………………… only, after ensuring that there are no persons in the danger zone. Switched off on: …………… at …... a.m./p.m. : DO NOT SWITCH ON Switch on by: ………………… only, after ensuring that there are no persons in the danger zone. 1. Switching off power supply. 2. If possible lock the switch with a lock and attach a sign as shown above to the switch so it is clearly visible. If the switch cannot be locked with a lock, attach a sign as shown in the lower illustration. 3. Leave the key with the employee named on the sign. 4. Once all work has been completed, ensure that there are no persons remaining in the danger zone. 5. Ensure that all safety equipment is installed and is in operating condition. 6. Only then remove the sign. Pos : 39.10 /-- Seitenumbruc h-- @ 0\mod_1275315941062_0.doc @ 1348 @ 332 @ 1 Page 24 of 101 Instruction Manual CSM722 SIFTER Order numberPTI003990-M22320, Doc-ID: APH 20-11-13 1.4 Transport, Packing and Storage Pos : 39.11 /03 Sicherheit/Verhalten i m Gefahr enfall und bei U nfällen --nur Titel-- @ 0\mod_1275471920671_968.doc @ 1058 @ 222 @ 1 1.3.9.1 Action in case of danger and accidents Pos : 39.12 /03 Sicherheit/Verhalten i m Gefahr enfall und bei U nfällen @ 0 \mod_1275471959625_968.doc @ 1059 @ 22 @ 1 Preventive actions Always be prepared for accidents or fire. Keep first-aid equipment (first-aid kit, blankets etc.) and fire extinguisher accessible. Ensure all persons are familiar with accident notification, first aid and rescue equipment. Keep accesses for emergency vehicles clear. Trigger emergency stop immediately. Start first aid. Rescue persons from danger zone. Notify supervisors at workplace. Call emergency services. Clear accesses for emergency vehicles. Action in case of accident Pos : 39.13 /03 Sicherheit/U mwelts chutz --nur Titel-- @ 0\mod_1275472044078_968.doc @ 1060 @ 211 @ 1 1.3.10 Environmental protection Pos : 39.14 /03 Sicherheit/U mwelts chutz (VOR SICHT) @ 0\mod_1275472145343_968.doc @ 1061 @ 222 @ 1 CAUTION Environmental hazard from incorrect working Incorrect working with environmentally hazardous substances, particularly improper disposal, may cause significant environmental damage. Always observe the relevant instructions. If environmentally hazardous substances are accidentally released, take appropriate action immediately. In case of doubt inform local authorities of the damage immediately. Pos : 39.15 /03 Sicherheit/U mwelts chutz , Schmi erstoffe @ 0\mod_1275472196296_968.doc @ 1062 @ 111 @ 1 The following environmentally hazardous substances are used: Lubricants Lubricants such as grease and oil contain poisonous substances. They must not be released into the environment. A specialist disposal company must be used for disposal. Pos : 86.1 /06 Transport, Verpac kung, Lager ung/Tr ansport, Verpac kung und Lager ung --nur Titel-- @ 0\mod_1275478748453_968.doc @ 1115 @ 3222322322222232 @ 1 1.4 Transport, Packing and Storage Pos : 86.2 /06 Transport, Verpac kung, Lager ung/Sic her heitshi nweis e für den Trans port --nur Titel-- @ 0\mod_1275478789328_968.doc @ 1116 @ 1311111111113333 @ 1 Instruction Manual CSM722 SIFTER Order number: PTI003990-M22320, Doc-ID: APH 20-11-13 Page 25 of 101 1.4 Transport, Packing and Storage 1.4.1 Safety instructions for transport Pos : 86.3 /06 Transport, Verpac kung, Lager ung/Sc hwebende Las ten ( WARNUN G) @ 0\mod_1275478835421_968.doc @ 1117 @ 322222 @ 1 Suspended loads WARNING Danger of death from suspended loads! Falling loads may cause serious or fatal injuries. Never walk under suspended loads. Move loads only under supervision. Lower the load when leaving the workplace. Empty the device completely before moving it. Use only lifting gear (crane, forklift) and lifting equipment with sufficient load capacity. Note the weight (see "Technical Data"). The operator must be qualified to operate the crane or the forklift. Pos : 86.4 /06 Transport, Verpac kung, Lager ung/Tr ansport, uns ac hgemässer @ 0\mod_1275478906609_968.doc @ 1118 @ 13323323 @ 1 CAUTION Damage from improper transport! Significant property damage may be caused by improper transport. When unloading packaged items on delivery and during transport on site work safely and observe the symbols and instructions on the packaging. Use only the specified attachment points. Do not remove packaging until shortly before assembly. Pos : 86.5 /--Seitenumbr uch-- @ 0\mod_1275315941062_0.doc @ 1348 @ 232222 @ 1 Page 26 of 101 Instruction Manual CSM722 SIFTER Order numberPTI003990-M22320, Doc-ID: APH 20-11-13 1.4 Transport, Packing and Storage Pos : 86.6 /06 Transport, Verpac kung, Lager ung/Tr ansport, Trans porti ns pektion --nur Titel-- @ 0\mod_1275478959921_968.doc @ 1119 @ 11111111133312222222222222223 @ 1 1.4.2 Transport inspection Pos : 86.7 /06 Transport, Verpac kung, Lager ung/Tr ansport, Trans porti ns pektion (HIN WEIS) @ 0\mod_1275479008281_968.doc @ 1120 @ 2222333333322223 @ 1 Check the delivery for completeness and transport damage immediately on receipt. Proceed as follows if external transport damage is detected: Do not accept the delivery or accept it conditionally only. Note the extent of the damage on the transport documentation or the delivery company's waybill. Initiate a claim. NOTE Submit a claim as soon as damage is detected. Claims for damages can only be made within the defined claim deadlines. Pos : 86.8 /06 Transport, Verpac kung, Lager ung/Tr ansport -- nur Ti tel-- @ 0\mod_1275479052796_968.doc @ 1121 @ 333333322333223233 @ 1 1.4.3 Transport Pos : 86.9 /06 Transport, Verpac kung, Lager ung/Tr ansport, Paletten mit Gabels tapler @ 0\mod_1275479112812_968.doc @ 1122 @ 3321222 @ 1 Transporting pallets with a forklift Fig. 3 1. Run the forklift with the forks between or under the boards of the pallet. 2. Insert the forks until they extend out the other side. 3. Make sure that the pallet cannot tip if the centre of gravity is outside the centre. 4. Lift the object and move it. Pos : 86.10 /06 Tr ans port, Verpac kung, Lagerung/Tr ans port, Pal etten mit Kr an @ 0\mod_1275479154625_968.doc @ 1123 @ 22222222222222 @ 1 Transporting pallets with a crane 1. Attach ropes, belts or multi-point attachments to the pallet as shown in the illustration. 2. Check that the packages will not be damaged by the attachments. 3. Lift the object and move it. Fig. 4 Pos : 86.11 /06 Tr ans port, Verpac kung, Lagerung/Misc her/Transport, Gerät mit Kran GMS ECD @ 4\mod_1307626605011_968.doc @ 12258 @ 223 @ 1 Transporting device with crane For transporting with a crane, disassemble the device into individual sub-assemblies (housing, drive, base frame) and transport them individually. (see over page). Instruction Manual CSM722 SIFTER Order number: PTI003990-M22320, Doc-ID: APH 20-11-13 Page 27 of 101 1.4 Transport, Packing and Storage NET WEIGHT 120 KG 1. Attach belts to the device as shown above. 2. Make sure that the device cannot tip if the centre of gravity is outside the centre. Pos : 87.1 /06 Transport, Verpac kung, Lager ung/Verpac kung --nur Titel-- @ 0\mod_1275479253156_968.doc @ 1125 @ 2222223 @ 1 Page 28 of 101 Instruction Manual CSM722 SIFTER Order numberPTI003990-M22320, Doc-ID: APH 20-11-13 1.4 Transport, Packing and Storage 1.4.4 Packaging Pos : 87.2 /06 Transport, Verpac kung, Lager ung/Verpac kung, U mg ang mit Verpac kungsmaterialien ( VOR SICHT) @ 0\mod_1275479297781_968.doc @ 1126 @ 32233 @ 1 Working packaging materials CAUTION Environmental damage from incorrect disposal! Sort and dispose of packaging material as required by the applicable legal regulations and local requirements. Pos : 87.3 /06 Transport, Verpac kung, Lager ung/Verpac kung @ 0\mod_1275479338343_968.doc @ 1127 @ 21322 @ 1 On packaging The individual packages are packed in accordance with the expected transport conditions. Environmentally compatible materials exclusively are used for packaging. The packaging is designed to protect all components from transport damage, corrosion and other damage until assembly. Therefore, do not destroy the packaging and do not remove it until shortly before assembly. Pos : 87.4 /06 Transport, Verpac kung, Lager ung/Lagerung --nur Titel-- @ 0\mod_1275479380187_968.doc @ 1128 @ 321322332222222 @ 1 1.4.5 Storage Pos : 87.5 /06 Transport, Verpac kung, Lager ung/Lagerung (HIN WEIS) @ 0\mod_1275479426109_968.doc @ 1129 @ 2122222233 @ 1 Storage of packages Store packages under the following conditions: Do not store outside. Store in dry and dust-free conditions. Do not expose it to aggressive substances. Do not expose to direct sun. Avoid mechanical vibrations. Storage temperature: 15 to 35 °C. Relative humidity: max. 60%. If stored for over three months inspect the status of all parts and the packaging regularly. If necessary, restore or replace the preservation. NOTE In some cases packages have instructions for storage in addition to the above requirements. These instructions must also be observed. Pos : 88.1 /07 Install ati on/Installati on --nur Titel-- @ 0\mod_1275479495265_968.doc @ 1130 @ 3333333233 @ 1 Instruction Manual CSM722 SIFTER Order number: PTI003990-M22320, Doc-ID: APH 20-11-13 Page 29 of 101 Installation 1.5 Installation Pos : 88.2 /07 Install ati on/Sic her hei tshi nweise zur Installati on --nur Titel-- @ 0\mod_1275479535750_968.doc @ 1131 @ 322222222222222221 @ 1 1.5.1 Safety instructions for installation Pos : 88.3 /07 Install ati on/Sic her hei tshi nweise zur Installati on @ 0\mod_1275479584625_968.doc @ 1132 @ 2222222 @ 1 The instructions in this section must be observed during installation in addition to all instructions in "Safety". Pos : 88.4 /07 Install ati on/El ektrisc her Str om (GEFAHR) @ 0\mod_1275479679015_968.doc @ 1133 @ 3333 @ 1 Danger from electrical current DANGER Danger of death from electrical current Before starting work switch off power supply and lock to prevent unauthorised reactivation. All work on electrical systems must be conducted by authorised electrical technicians only. Pos : 88.5 /07 Install ati on/Weitere Gefahr en (WARNUNG) @ 0\mod_1275479933812_968.doc @ 1134 @ 3 @ 1 Additional dangers WARNING Danger of injury by pneumatic energy! Danger of injury by moving parts! Danger of burns from hot surfaces! Danger of injury when lifting loads! Danger to health from hazardous substances! Danger of injury from improper working! Observe the instructions in "Safety". Wear suitable personal protective equipment. Observe general occupational health and safety regulations. Pos : 88.6 /07 Install ati on/Personal @ 0 \mod_1275480062812_968.doc @ 1136 @ 3333333 @ 1 Personnel All work must be carried out by appropriately qualified technicians only. Pos : 88.7 /07 Install ati on/Persönliche Sc hutz ausr üstung @ 0\mod_1275480092500_968.doc @ 1137 @ 2222222222222222 @ 1 Personal protective equipment Wear suitable personal protective equipment. Pos : 89.1 /07 Install ati on/Explosionssc hutz, Zündquellen vermeiden (EX) ATEX @ 0\mod_1275480017328_968.doc @ 1135 @ 2323332232 @ 1 Pos : 90.1 /07 Install ati on/Anforderungen an den Aufstell ort --nur Titel-- @ 0\mod_1275480131531_968.doc @ 1138 @ 33333332222333333333332333 @ 1 1.5.2 Requirements at the installation location Pos : 90.2 /07 Install ati on/Uns ac hgemäss es Aufstellen ( WARNUN G) @ 0 \mod_1275480174359_968.doc @ 1139 @ 233323332 @ 1 Incorrect installation Page 30 of 101 WARNING Danger of injury from incorrect installation! Incorrect installation or inadequate support by the foundation may cause serious personal injury and/or property damage. Install the device only if the foundation has sufficient supporting capacity and adequate Instruction Manual CSM722 SIFTER Order numberPTI003990-M22320, Doc-ID: APH 20-11-13 Installation fastening options. Pos : 90.3 /07 Install ati on/Anforderungen Aufstellort, Ei nleitung @ 0\mod_1275480227218_968.doc @ 1140 @ 33333 @ 1 Before installation ensure that the installation location meets the following requirements: Pos : 90.4 /07 Install ati on/Anforderungen Aufstellort, Aufz ählung @ 0\mod_1275480275078_968.doc @ 1141 @ 232 @ 1 A level, stable and distortion-free foundation is available that will not distort the device when the bolts are tightened. The installation site has sufficient space and good accessibility for installation, maintenance, repair and cleaning work. Vibrations and shocks from neighbouring machines or systems will not be transmitted to the device. The ambient temperature is limited to the maximum approved value as specified in "Technical Data". The drive is adequately ventilated. The minimum distances between the motor fan and adjacent components (as specified in the manual) are correct. If the ambient temperature in the area of the drive is above the limit value, it must be reduced to an approved value by suitable measures, such as insulation from a heat source, active cooling etc. The supply lines for the connected media are laid out in accordance with the applicable local accident prevention regulations and as specified in "Technical Data". The requirements specified in "Technical Data" are met. Pos : 91.1 /07 Install ati on/Vor der Ins tall ation prüfen -- nur Ti tel-- @ 0\mod_1275480322046_968.doc @ 1142 @ 23323332233333333333 @ 1 1.5.3 Checks before installation Pos : 91.2 /07 Install ati on/Explosionsgefahr, z onenekonfor m (Ex) AT EX @ 0\mod_1275480355140_968.doc @ 1143 @ 23 @ 1 Pos : 91.3 /07 Install ati on/Vor der Ins tall ation prüfen, mit Ver weis Kap. Tec hnische D aten (HIN WEIS) @ 0\mod_1275480397531_968.doc @ 1144 @ 121 @ 1 Before installation check that the following items are correct: The connected voltage of the electrical equipment specified in "Technical Data" conforms to the values on the nameplates. The device is complete and in good technical condition. NOTE Contact the manufacturer at the address shown on the title page without delay if any problems are found. Instruction Manual CSM722 SIFTER Order number: PTI003990-M22320, Doc-ID: APH 20-11-13 Page 31 of 101 Installation Pos : 92.1 /07 Install ati on/Gerät aufs tell en --nur Titel-- @ 0\mod_1275480462796_968.doc @ 1145 @ 2222123 @ 1 1.5.4 Installing device Pos : 92.2 /07 Install ati on/Mischer/Ger ät aufstellen GMS ECD -- Bild-- @ 4\mod_1307627530726_968.doc @ 12262 @ 233 @ 1 4- MOUNTING HOLES IN FOOT PADS Fig. 5: Installing device Pos : 92.3 /07 Install ati on/Mischer/Ger ät aufstellen GMS (VOR SICHT) @ 4\mod_1307627865039_968.doc @ 12266 @ 323 @ 1 Proceed as follows for installation: Level the device at installation site. Bolt the sifter foot pads to the support frame. The support frame must be sufficiently strong, stable, horizontal and levelled. The device must be fixed on all foot pads. Do not allow the casing to be distorted CAUTION Property damage by distortion of the casing! Inadequate or uneven support may distort the casing. The above conditions must be observed. Pos : 93.1 /07 Install ati on/Gerät aufs tell en --nur Titel-- @ 0\mod_1275480462796_968.doc @ 1145 @ 322311111111122 @ 1 Pos : 94.1 /07 Install ati on/Pr odukteinl auf und - auslauf montier en --nur Titel-- @ 0\mod_1275480575046_968.doc @ 1148 @ 32333233222223 @ 1 1.5.5 Installing product inlet and outlet Pos : 94.2 /02 Gerätebes chr eibung/Misc her/Bestg em. Ver wendung, nic ht monti erter Produkteinl auf ( WARNUN G) @ 1\mod_1293176196869_968.doc @ 2990 @ 2231211111111 @ 1 Operation forbidden with open product inlet, product outlet or other open spigots Page 32 of 101 WARNING Operating without mounted product inlet or outlet or if other spigots (e.g. aspiration spigots) are not connected or are not closed, contact may result with the feed worm if the operator reaches Instruction Manual CSM722 SIFTER Order numberPTI003990-M22320, Doc-ID: APH 20-11-13 Installation into these openings. This may cause serious injury or death. Never operate the device without an installed product inlet and outlet. Likewise, other available spigots must be connected or properly sealed. Pos : 94.3 /07 Install ati on/Verspannungen des Gehäuses (VORSICHT) @ 0\mod_1275480706734_968.doc @ 1151 @ 32212 @ 1 Do not allow the casing to be distorted CAUTION Property damage by distortion of the casing! If the inlet or outlet is overloaded the device casing with be distorted. Inlets and outlets that are fixed to the device with a separate support must be designed to prevent distortion of the device casing. Consult the manufacturer if necessary. Pos : 94.4 /07 Install ati on/Mischer/Produktei n- und - ausl auf montier en, Anforderungen @ 0\mod_1275480757437_968.doc @ 1152 @ 21111222 @ 1 The following requirements apply when installing inlet and outlet: The device casing must not be distorted by installing the inlet and outlet. Dust or bulk material must not escape at the connection points of the device and inlet or outlet. Pos : 95 /07 Installati on/Mischer/Produktei nlauf GM S ohne D ec kel Energiekette @ 5\mod_1344838733756_968.doc @ 28235 @ 3 @ 1 Pos : 97.1 /07 Install ati on/Explosionssc hutz, Zündrisiko Staubaustritt ( EX) AT EX @ 0\mod_1275480661687_968.doc @ 1150 @ 32233323 @ 1 Pos : 98 /07 Installati on/Mischer/Produktausl auf GMS Standard Neu @ 4\mod_1331200376432_968.doc @ 25953 @ 232333 @ 1 1.5.6 Connecting device Pos : 100.2 /07 Installation/Antrieb ans chli essen -- nur Ti tel-- @ 0\mod_1275481000421_968.doc @ 1155 @ 233233333333333323 @ 1 1.5.6.1 Connecting drive Pos : 100.3 /07 Installation/Misc herAntrieb anschli ess en GM S 2800 mit FU @ 1\mod_1283539356876_968.doc @ 1941 @ 2322233332 @ 1 When connecting the drive: Observe the regulations applicable at the operation location of the device and the enclosed drive manual. Ensure that the drive is adequately ventilated. The minimum distances between the motor fan and adjacent components (as specified in the manual) must be correct. The ambient temperature must be limited to the maximum approved value as specified by the manufacturer. If the ambient temperature exceeds the limit value, reduce it with suitable measures, e.g. insulation of the heat source or active cooling. Ensure that the drive rotates in the correct direction. The direction of rotation of the drive must conform to the arrow on the drive. See the manual and wiring instructions supplied by the manufacturer of the frequency converter. Follow the enclosed wiring diagrams when connecting electrical equipment. Ensure that the wiring conforms to local codes. Instruction Manual CSM722 SIFTER Order number: PTI003990-M22320, Doc-ID: APH 20-11-13 Page 33 of 101 1.6 Initial Commissioning Pos : 116.1 /08 Erstinbetriebnahme/Ersti nbetriebnahme --nur Titel-- @ 0\mod_1275930194687_968.doc @ 1342 @ 11123233322222222222211 @ 1 1.6 Initial Commissioning Pos : 116.2 /08 Erstinbetriebnahme/Sic her heits hinweise zur Ersti nbetri ebnahme --nur Titel-- @ 0\mod_1275483964453_968.doc @ 1204 @ 112222222222122222222 @ 1 1.6.1 Safety instructions for initial commissioning Pos : 116.3 /08 Erstinbetriebnahme/Hinweise beachten @ 0\mod_1275483848859_968.doc @ 1203 @ 222222 @ 1 The instructions in this section must be observed during initial commissioning with and without bulk material in addition to all instructions in "Safety". Pos : 116.4 /07 Installation/Elektrischer Strom (GEFAHR) @ 0\mod_1275479679015_968.doc @ 1133 @ 22332 @ 1 Danger from electrical current DANGER Danger of death from electrical current Before starting work switch off power supply and lock to prevent unauthorised reactivation. All work on electrical systems must be conducted by authorised electrical technicians only. Pos : 116.5 /02 Ger ätebesc hrei bung/Misc her/Bestgem. Ver wendung, nic ht montierter Produktei nlauf (WARNUNG) @ 1\mod_1293176196869_968.doc @ 2990 @ 22222223 @ 1 Operation forbidden with open product inlet, product outlet or other open spigots WARNING Operating without mounted product inlet or outlet or if other spigots (e.g. aspiration spigots) are not connected or are not closed, contact may result with the feed worm if the operator reaches into these openings. This may cause serious injury or death. Never operate the device without an installed product inlet and outlet. Likewise, other available spigots must be connected or properly sealed. Pos : 116.6 /07 Installation/Weitere Gefahren ( WARNUNG) @ 0\mod_1275479933812_968.doc @ 1134 @ 23222222222223332 @ 1 Additional dangers WARNING Danger of injury by pneumatic energy! Danger of injury by moving parts! Danger of burns from hot surfaces! Danger of injury when lifting loads! Danger to health from hazardous substances! Danger of injury from improper working! Observe the instructions in "Safety". Wear suitable personal protective equipment. Observe general occupational health and safety regulations. Pos : 116.7 /11 Wartung/Misc her/Sc häden bei m Öffnen Sei tentür/Fronttür e (VORSICHT) @ 4 \mod_1320535272506_968.doc @ 23240 @ 222222222 @ 1 Prevent damage when opening the side or front Page 34 of 101 CAUTION! In order to prevent damages do not open the door Instruction Manual CSM722 SIFTER Order numberPTI003990-M22320, Doc-ID: APH 20-11-13 1.6 Initial Commissioning door until the solenoid interlock is unlocked. Pos : 116.8 /07 Installation/Pers onal @ 0\mod_1275480062812_968.doc @ 1136 @ 23 @ 1 Personnel All work must be carried out by appropriately qualified technicians only. Pos : 116.9 /08 Erstinbetriebnahme/Persönlic he Sc hutz ausr üstung @ 0\mod_1275484424859_968.doc @ 1211 @ 22223 @ 1 Personal protective equipment Wear suitable personal protective equipment. Check with on-site supervisors whether additional personal protective equipment, such as a respirator, is required. Pos : 117.1 /07 Installation/Explosi onsschutz, Z ündq uellen ver meiden (EX) AT EX @ 0\mod_1275480017328_968.doc @ 1135 @ 22221 @ 1 Pos : 118.1 /08 Erstinbetriebnahme/Pr obelauf durchführen -- nur Ti tel-- @ 0\mod_1275484457312_968.doc @ 1212 @ 3222333333322 @ 1 1.6.2 Test run Pos : 118.2 /08 Erstinbetriebnahme/Pr obelauf wann notwendig @ 0\mod_1275484507390_968.doc @ 1213 @ 323 @ 1 Test runs are required for initial commissioning, after correction of malfunctions, after extended downtime, after maintenance, repair and cleaning. Pos : 118.3 /08 Erstinbetriebnahme/Mischer/Vor dem Probel auf GM S C AT EX @ 0\mod_1275484608437_968.doc @ 1214 @ 333222222222222233333 @ 1 1.6.2.1 Before the test run Copy the "Checklist before test run" in the appendix and record the filling level while running through the items listed below. 1. Switch off power supply (if not already done) and lock to prevent reactivation. 2. Check that the device is earthed as specified. 3. Ensure that all safety equipment is installed and is in operating condition. 4. Check all connections for tightness and leaks. 5. All monitors must be in operating condition. Pos : 119.1 /08 Erstinbetriebnahme/Mischer/Probel auf ohne Schüttgut/Probelauf ohne Sc hüttgut --nur Titel-- @ 0\mod_1275484705859_968.doc @ 1215 @ 12223232222222 @ 1 1.6.2.2 Test run without product Pos : 119.2 /08 Erstinbetriebnahme/Mischer/Probel auf ohne Schüttgut/Probelauf ohne Produkt durchführen @ 0\mod_1275484794609_968.doc @ 1217 @ 22233333333 @ 1 Test run without product: 1. Restore power supply. 2. Switch on device. 3. Run the device empty for approximately 30 minutes if no problems occur during this period. Stop the device immediately if any problems are detected. Pos : 119.3 /08 Erstinbetriebnahme/Mischer/Probel auf ohne Schüttgut/Folgende Punkte pr üfen Misc her ohne Produkt @ 3\mod_1300442868765_968.doc @ 9579 @ 3333 @ 1 Test the following items during the test run: The direction of rotation of the shaft matches the arrow stamped on the drive or on the housing. Instruction Manual CSM722 SIFTER Order number: PTI003990-M22320, Doc-ID: APH 20-11-13 Page 35 of 101 1.6 Initial Commissioning The power consumption of the drive is in the approved range (see "Technical Data"). There are no unusual noises or temperatures in the drive. There is no unusual temperature in the shaft seal. No bearing, grinding or abrasion noises are heard. If one of the above items is not passed: 1. Stop the device. 2. Find and correct the cause of the malfunction using the troubleshooting table. If the malfunction cannot be corrected with the troubleshooting table, contact the manufacturer. Pos : 120.1 /08 Erstinbetriebnahme/Mischer/T emperatur Lager und Wellendi chtungen über wac hen AT EX @ 3\mod_1300442583783_968.doc @ 9575 @ 32222223 @ 1 Pos : 121.1 /08 Erstinbetriebnahme/Mischer/Probel auf mit Sc hüttgut/Probel auf mit Sc hüttgut --nur Titel-- @ 0\mod_1275484883343_968.doc @ 1219 @ 322112222 @ 1 1.6.2.3 Test run with product Pos : 121.2 /08 Erstinbetriebnahme/Mischer/Probel auf mit Sc hüttgut/Ger ätesc haden durch Vi brati onen (VORSICHT) @ 0 \mod_1275484966703_968.doc @ 1221 @ 3323312222232 @ 1 CAUTION Damage to the device by vibrations! Vibrations indicate that the device has not been correctly installed and may cause damage. If vibrations are detected stop the device immediately and contact the manufacturer. Pos : 121.3 /08 Erstinbetriebnahme/Mischer/Probel auf mit Sc hüttgut/Probel auf durc hführen mit Produkt Batc h @ 0 \mod_1275485000390_968.doc @ 1222 @ 23211111 @ 1 Test run with product: 1. Switch on device. 2. Meter product into sifter Pos : 121.4 /08 Erstinbetriebnahme/Mischer/Probel auf mit Sc hüttgut/F olgende Punkte prüfen Misc her mit Produkt @ 3\mod_1300443074311_968.doc @ 9583 @ 12333 @ 1 Test the following items during the test run: The shaft seals are fully functional, i.e. product does not escape. There is no product accumulation. If one of the above items is not passed: 1. Stop the device. 2. Find and correct the cause of the malfunction using the troubleshooting table. If the malfunction cannot be corrected with the troubleshooting table, contact the manufacturer. 1.6.2.4 Set limit values for air purge seal The pressure at the seals is 0.3 – 0.5 bar (this is a reference value). Page 36 of 101 Instruction Manual CSM722 SIFTER Order numberPTI003990-M22320, Doc-ID: APH 20-11-13 Operation Pos : 124.1 /09 Betrieb/Betri eb --nur Titel-- @ 0\mod_1275485908296_968.doc @ 1233 @ 22111111121222222 @ 1 1.7 Operation Pos : 124.2 /09 Betrieb/Betri eb @ 0\mod_1275485963546_968.doc @ 1234 @ 112212 @ 1 The device is operated as a component in a system. Operators are not required at the device during operation. The system controller switches the device on and off with reference to the safety regulations and the working and operating conditions. Pos : 124.3 /09 Betrieb/Sic herheits hinweise z um Betri eb --nur Titel-- @ 0\mod_1275486040312_968.doc @ 1235 @ 22121222222223312222223222222 @ 1 1.7.1 Safety instructions for operation Pos : 124.4 /11 Wartung/Misc her/Sc häden bei m Öffnen Sei tentür/Fronttür e (VORSICHT) @ 4 \mod_1320535272506_968.doc @ 23240 @ 22222222222233222222222221221 @ 1 Prevent damage when opening the side or end door CAUTION! In order to prevent damage do not open the doors with undue force or violently. Pos : 125.1 /09 Betrieb/Misc her Expl osionss chutz , Z ündrisi ko Staubaustritt (EX) AT EX @ 3 \mod_1300365086171_968.doc @ 9434 @ 11111121 @ 1 Pos : 126.1 /09 Betrieb/Bedienung --Titel-- @ 0\mod_1275486161609_968.doc @ 1238 @ 233122222232222222222222222 @ 1 1.7.2 Operation Pos : 126.2 /09 Betrieb/Ver weis auf (separ ate) Betri ebsanleitung Steuer ung @ 1\mod_1283540955343_968.doc @ 1970 @ 2213333 @ 1 The operation of the control of the device must be described in a corresponding manual which is to be created by the system builder or the operating company. Pos : 127.1 /10 Störung/Störungen --nur Titel-- @ 0\mod_1275486298062_968.doc @ 1240 @ 22222222 @ 1 Instruction Manual CSM722 SIFTER Order number: PTI003990-M22320, Doc-ID: APH 20-11-13 Page 37 of 101 Malfunctions 1.8 Malfunctions Pos : 127.2 /10 Störung/Störungen @ 0\mod_1275486341078_968.doc @ 1241 @ 122112 @ 1 This section describes possible causes of malfunctions and how to correct them. Pos : 127.3 /10 Störung/Vermehrt auftretende Stör ungen @ 0\mod_1275486438671_968.doc @ 1243 @ 2222222222 @ 1 If malfunctions continue to occur reduce the service intervals and if applicable modify the design of the system after consultation with the manufacturer. For malfunctions that cannot be corrected with the following instructions contact the manufacturer (see service address on title page). Pos : 128.1 /10 Störung/Explosionssc hutz, Stör ungen als Z ündrisi ko (EX) ATEX @ 0\mod_1275486393562_968.doc @ 1242 @ 222 @ 1 Pos : 129.1 /10 Störung/Sic her hei tshi nweise zur Störungsbes eitigung --nur Titel-- @ 0\mod_1275486532750_968.doc @ 1244 @ 31232233222222222222212 @ 1 1.8.1 Safety instructions for troubleshooting Pos : 129.2 /10 Störung/Sic her hei tshi nweise zur Störungsbes eitigung @ 0\mod_1275486620875_968.doc @ 1245 @ 22 @ 1 The instructions in this section must be observed in addition to all instructions in "Safety". Pos : 129.3 /07 Installation/Elektrischer Strom (GEFAHR) @ 0\mod_1275479679015_968.doc @ 1133 @ 2 @ 1 Danger from electrical current DANGER Danger of death from electrical current Before starting work switch off power supply and lock to prevent unauthorised reactivation. All work on electrical systems must be conducted by authorised electrical technicians only. Pos : 129.4 /-- Seitenumbruc h-- @ 0\mod_1275315941062_0.doc @ 1348 @ 312122 @ 1 Page 38 of 101 Instruction Manual CSM722 SIFTER Order numberPTI003990-M22320, Doc-ID: APH 20-11-13 Malfunctions Pos : 129.5 /07 Installation/Weitere Gefahren ( WARNUNG) @ 0\mod_1275479933812_968.doc @ 1134 @ 23222222333 @ 1 Additional dangers WARNING Danger of injury by pneumatic energy! Danger of injury by moving parts! Danger of burns from hot surfaces! Danger of injury when lifting loads! Danger to health from hazardous substances! Danger of injury from improper working! Observe the instructions in "Safety". Wear suitable personal protective equipment. Observe general occupational health and safety regulations. Pos : 129.6 /07 Installation/Pers onal @ 0\mod_1275480062812_968.doc @ 1136 @ 332222222222222 @ 1 Personnel All work must be carried out by appropriately qualified technicians only. Pos : 129.7 /08 Erstinbetriebnahme/Persönlic he Sc hutz ausr üstung @ 0\mod_1275484424859_968.doc @ 1211 @ 2333 @ 1 Personal protective equipment Wear suitable personal protective equipment. Check with on-site supervisors whether additional personal protective equipment, such as a respirator, is required. Pos : 129.8 /10 Störung/Verhalten bei Störungen (HIN WEIS) @ 0\mod_1275487020828_968.doc @ 1251 @ 2212322333332222 @ 1 Action in case of malfunction Basic requirements: 1. Actuate the emergency stop function for malfunctions that present an immediate danger for persons or property. 2. Find the cause of the malfunction. 3. Switch off the device and lock to prevent reactivation. 4. Notify supervisors on site of the malfunction immediately. 5. Depending on the type of malfunction have it repaired by authorised technicians. NOTE The following troubleshooting table specifies who is authorised to correct a malfunction. Pos : 131 /--Seitenumbruc h-- @ 0\mod_1275315941062_0.doc @ 1348 @ 21332 @ 1 Instruction Manual CSM722 SIFTER Order number: PTI003990-M22320, Doc-ID: APH 20-11-13 Page 39 of 101 Malfunctions Pos : 132.1 /10 Störung/Störungstabelle --nur Titel-- @ 0\mod_1275487078843_968.doc @ 1252 @ 222222111111222222122 @ 1 1.8.2 Troubleshooting table Pos : 132.2 /10 Störung/Mischer/Störungstabelle GMS @ 1\mod_1283541135546_968.doc @ 1975 @ 221232 @ 1 Malfunction Possible cause Troubleshooting Remedy by Shaft seal Shaft seal is incorrectly installed. Install shaft seal correctly. Technician Shaft seal is dirty. Inspect and clean shaft seal. Technician Shaft seal is worn. Replace shaft seal. Technician Air purge seal not connected to air supply. Pressure to air seals too low Check air connection and air pressure at individual seals. Technician Product escapes in the area of the inlet, outlet and doors. The seals (flat gaskets, Clean, replace or accurately extrusions) are not accurately position seals. positioned, are dirty or worn. Technician Device does not start. Door interlock switch not fully Check interlock switches. located with actuator. Technician There is no power at the drive. Inspect power supply wiring (are all phases connected?). Check main switch, motor safety switch, emergency stop. Electrical technician The drive has no power. Check power supply. Electrical technician Defective drive. Replace drive. Technician/Elec trical technician The sifter full of product at start up. The sifter must always be Technician/Elec started empty. Starting under trical technician load may cause damage to the drive, shaft and basket. The sifter must always be run longer than the in feed of product. The sifter must always start empty. Motor fault. Have manufacturer replace motor. See title page for address. Shaft assembly does not rotate. Page 40 of 101 Electrical technician Instruction Manual CSM722 SIFTER Order numberPTI003990-M22320, Doc-ID: APH 20-11-13 Malfunctions Malfunction Possible cause Troubleshooting Remedy by Drive blocked. Product jammed between casing and paddles. Clean product chamber. Technician Remove foreign bodies. Replace damaged components. Take suitable action to ensure that foreign bodies are not introduced to the product chamber with the product. Technician Unsuitable product Contact the raw product manufacturer Raw Product Manufacturer Incorrect motor direction of rotation. Check and change direction of rotation. Electrical technician Worn bearings may cause light rattling noise. Check the ends of the shaft for undue ‘lift’ near the bearing. Replace the bearing if worn. Technician A knocking noise may be caused by the feed worm or the paddle fixed screw working loose. Check and re-tighten as necessary. Technician A rubbing noise (metal to metal) may be caused by the bearing grub screws at the drive end working loose and allowing the drive shaft to float and the feed worm to rub against the casing. Re-locate the bearing locating grub screws in the dimples in the shaft and securely tighten. Technician Excess noise at non drive bearing. Check condition of end door bearing spring plunger and replace as necessary. Technician Basket screen failure Replace screen and check all Technician clearances and security of paddle blades, bosses and feed worm Abnormal noise in Foreign bodies jammed in product chamber product chamber Instruction Manual CSM722 SIFTER Order number: PTI003990-M22320, Doc-ID: APH 20-11-13 Page 41 of 101 Malfunctions Malfunction Possible cause Troubleshooting Excessive motor loading (as indicated by the motor tripping out the overloads). Overfeeding Check feed rate. Start at zero Technician feed rate and increase until correct ammeter reading is reached. Sieve hose blinding Check sieve hose tension and re-tighten if necessary. Check position of paddle blades relative to sieve hose or screen and adjust if necessary. Technician Fines outlet and/or oversize outlet blocked or restricted. Product will ‘back up’ into the sifter and cause overload. Check and rectify. Technician Checked for seized bearing. Seals may be leaking and causing product to breach the seals. Replace seals and bearings. Technician Paddle blades moved or damaged. Adjust and re-balance. Replace adjust and rebalance. Technician Excess vibration. Machine stops Vibration or bearing failure. from bearing over temperature. Remedy by If vibration, adjust and reTechnician balance. If bearing failure, replace bearing and check integrity of shaft. Pos : 132.3 /-- Seitenumbruc h-- @ 0\mod_1275315941062_0.doc @ 1348 @ 323 @ 1 1.8.3 After correction of malfunctions Pos : 132.6 /10 Störung/Pr obelauf durchführen @ 0\mod_1275488139578_968.doc @ 1255 @ 21222222 @ 1 After correcting malfunctions conduct a test run (see "Initial Commissioning"). Page 42 of 101 Instruction Manual CSM722 SIFTER Order numberPTI003990-M22320, Doc-ID: APH 20-11-13 Maintenance and Repair Pos : 132.4 /10 Störung/Mischer/U ngenüg ende Misc hergebnis se Tabelle GMS @ 4 \mod_1307686543969_968.doc @ 12280 @ 33232133333332 @ 1 Pos : 132.5 /10 Störung/Nac h der Bes eitigung von St örungen --nur Titel-- @ 0\mod_1275488085062_968.doc @ 1254 @ 321233222222222222222222 @ 1 Pos : 133.1 /11 Wartung/Wartung und R eparatur --nur Titel-- @ 0\mod_1275488202125_968.doc @ 1256 @ 322233333233321 @ 1 1.9 Maintenance and Repair Pos : 133.2 /11 Wartung/Sic herheits hinweis e z ur Wartung und Reparatur --nur Titel-- @ 1\mod_1277122674921_968.doc @ 1360 @ 212322222222222222222222222212322333332222213333333 @ 1 1.9.1 Safety instructions for maintenance and repair Pos : 133.3 /11 Wartung/Sic herheits hinweis e z ur Wartung und Reparatur @ 0\mod_1275488306187_968.doc @ 1258 @ 222222222222222223222123 @ 1 The instructions for all maintenance and repair work in this section must be observed. Pos : 133.4 /11 Wartung/El ektrisc her Strom ( GEF AHR) @ 0\mod_1275488356875_968.doc @ 1259 @ 222222 @ 1 Danger from electrical current DANGER Danger of death from electrical current Contact with live parts is an immediate risk of death. Live electrical components may move uncontrolled and cause very serious injury. Before starting work switch off power supply and lock to prevent unauthorised reactivation. All work on electrical systems must be conducted by authorised electrical technicians only. Pos : 133.5 /07 Installation/Weitere Gefahren ( WARNUNG) @ 0\mod_1275479933812_968.doc @ 1134 @ 22 @ 1 Additional dangers WARNING Danger of injury by pneumatic energy! Danger of injury by moving parts! Danger of burns from hot surfaces! Danger of injury when lifting loads! Danger to health from hazardous substances! Danger of injury from improper working! Observe the instructions in "Safety". Wear suitable personal protective equipment. Observe general occupational health and safety regulations. Pos : 133.6 /07 Installation/Pers onal @ 0\mod_1275480062812_968.doc @ 1136 @ 233333333222 @ 1 Instruction Manual CSM722 SIFTER Order number: PTI003990-M22320, Doc-ID: APH 20-11-13 Page 43 of 101 Maintenance and Repair Personnel All work must be carried out by appropriately qualified technicians only. Pos : 133.7 /08 Erstinbetriebnahme/Persönlic he Sc hutz ausr üstung @ 0\mod_1275484424859_968.doc @ 1211 @ 222222222222222222222221232233333222222 @ 1 Personal protective equipment Wear suitable personal protective equipment. Check with on-site supervisors whether additional personal protective equipment, such as a respirator, is required. s: 133.8 /--Seitenumbruc h-- @ 0\mod_1275315941062_0.doc @ 1348 @ 2 22 @ 1 Environmental protection Observe the following instructions for environmental protection during maintenance work: Remove leaked, used or excess grease from all manually lubricated grease points and dispose of in accordance with regulations. Pos : 134.1 /07 Installation/Explosi onsschutz, Z ündq uellen ver meiden (EX) AT EX @ 0\mod_1275480017328_968.doc @ 1135 @ 32222233222222122212222 @ 1 1.9.2 Maintenance schedule Pos : 135.2 /11 Wartung/Wartung, Einl eitung @ 4 \mod_1309784439797_968.doc @ 13038 @ 331222 @ 1 The device must be serviced regularly and faults must be repaired. Pos : 135.3 /11 Wartung/Inter vall e ggf. anpass en @ 0\mod_1275488940093_968.doc @ 1268 @ 222233332322132 @ 1 The maintenance work required for optimum and fault-free operation are described in the following sections. Contact the manufacturer at the address shown on the title page with any questions about maintenance work and intervals. The intervals shown "Maintenance Schedule" table are recommended by the manufacturer for continuous operation of the device. The operator must adjust the maintenance intervals to the operating conditions, the bulk material and if applicable internal plant cycles, such as cleaning processes. Bearings and other parts will wear at different rates depending on the load and operating conditions. If increased wear is detected at regular inspections the maintenance intervals must be reduced appropriately. NOTE See the manufacturer's instructions for maintenance intervals and instructions for maintenance work for OEM components. Pos : 136.1 /11 Wartung/Wartung, Einl eitung ATEX @ 0 \mod_1275488790125_968.doc @ 1266 @ 22221222222222222222 @ 1 The device must be serviced regularly and faults must be repaired. To maintain explosive safety the following is particularly important: Page 44 of 101 Instruction Manual CSM722 SIFTER Order numberPTI003990-M22320, Doc-ID: APH 20-11-13 Maintenance and Repair Pos : 133.9 /11 Wartung/U mwel tsc hutz @ 0\mod_1275488679171_968.doc @ 1264 @ 2222 @ 1 Pos : 135.1 /11 Wartung/Wartungspl an --nur Titel-- @ 0\mod_1275488735484_968.doc @ 1265 @ 22222222212222222222222212 @ 1 os: 135.4 /11 Wartung/Fr emddokumente, Hi nweis @ 0\mod_1275489021437_968.doc @ 1269 @ 22 @ 1 1.9.2.1 Maintenance schedule Interval Maintenance Conducted by during cleaning and by detection of leaks Seal of cover, of doors, of flange, check for wear, if required clean or replace. Technician daily Visually inspect the entire device and all wiring for damage. Maintenance technicians After 5000 h (recommendation) Check sifter shaft bearing. At a higher bearing temperature, heavy dust accumulation or heavy load, the longevity of the lubricating grease and the service life of the bearings is shortened. Manufacturer Pos : 138.1 /11 Wartung/Wartungsar beiten --nur Titel-- @ 0\mod_1275489149453_968.doc @ 1271 @ 2222222222212 @ 1 1.9.3 Maintenance Pos : 138.2 /11 Wartung/H erstell er bezi ehen evtl. (VOR SICHT) @ 0\mod_1275489239031_968.doc @ 1272 @ 12223 @ 1 CAUTION! Consultation with the manufacturer is recommended for maintenance or repair work not listed in this manual to prevent incorrect working or damage. See title page for address. Pos : 138.3 /-- Seitenumbruc h-- @ 0\mod_1275315941062_0.doc @ 1348 @ 32222 @ 1 Instruction Manual CSM722 SIFTER Order number: PTI003990-M22320, Doc-ID: APH 20-11-13 Page 45 of 101 Maintenance and Repair Pos : 138.4 /11 Wartung/R einigung/Rei nigen @ 0 \mod_1275489295609_968.doc @ 1273 @ 233332222222 @ 1 1.9.3.1 Cleaning The device must be cleaned inside and outside at regular intervals. Pos : 138.5 /11 Wartung/R einigung/Sc häden durc h unsac hgemäss e R einigung (VORSICHT) @ 0 \mod_1275489489000_968.doc @ 1277 @ 323 @ 1 Prevent damage from incorrect cleaning CAUTION Incorrect cleaning may damage seals etc. Ensure that the temperature of the cleaning agent does not exceed the maximum approved values. Do not use aggressive cleaning agents. Use only cleaning agents that do not chemically damage the device. Take the requirements at the site into account when selecting the cleaning agent. Do not use pressure cleaners or compressed air. Pos : 138.6 /11 Wartung/Misc her/Sc häden bei m Öffnen Sei tentür/Fronttür e (VORSICHT) @ 4 \mod_1320535272506_968.doc @ 23240 @ 22222222222 @ 1 Pos : 138.7 /11 Wartung/Misc her/Auss enr einigung @ 0\mod_1275489589500_968.doc @ 1279 @ 2123 @ 1 Exterior cleaning 1. Vacuum the device. Pos : 138.8 /11 Wartung/Misc her/Innenr einigung GM S ECD ATEX @ 4\mod_1307687166578_968.doc @ 12288 @ 2223 @ 1 Interior cleaning CAUTION! During cleaning ensure that product and cleaning agent cannot penetrate the shaft seal, otherwise the sealing and purge gas feed must be switched on during this process. 1. Make sure that no product can flow into the device/is left in the device, and empty the device. 2. Switch off the device with upstream and downstream apparatus and system components and lock to prevent reactivation. 3. Ensure that there are no ignition sources in the work area. 4. Ensure that the device is cooled to ambient temperature. 5. Ask supervisors on site what additional personal protective equipment is required to eliminate the risk of health damage by substances in the device. Use the required personal protective equipment. 6. Open access to product chamber. Pos : 148.1 /11 Wartung/Misc her/M ass nahmen nac h erfolgter War tung oder Reparatur --nur Titel-- @ 0\mod_1275493062968_968.doc @ 1297 @ 322222212122 @ 1 Page 46 of 101 Instruction Manual CSM722 SIFTER Order numberPTI003990-M22320, Doc-ID: APH 20-11-13 Disassembly and Disposal 1.9.4 Actions after maintenance or repair Pos : 148.2 /11 Wartung/Misc her/Verletz ungsgefahr fehlende Sc hutz abdec kung en ( WARNUNG) @ 0\mod_1275493111062_968.doc @ 1298 @ 2122 @ 1 WARNING Danger of injury by missing safety covers! If the covers are not installed, rotating machine components may cause injury. Install all covers correctly. Do not operate device with missing covers. Pos : 148.3 /11 Wartung/Misc her/M ass nahmen nac h erfolgter War tung oder Reparatur @ 0\mod_1275493190843_968.doc @ 1299 @ 33321122 @ 1 Do the following after maintenance work: 1. Check that all screws that were removed are tight. 2. Check that all previously removed safety equipment and covers have been correctly installed. 3. Ensure that all tools, materials and other equipment have been removed from the work area. 4. Clean work area and remove any leakages, such as liquids, processing material or similar. 5. Ensure that all safety equipment on the system is installed and is in operating condition. 6. Conduct a test run (see "Initial Commissioning"). Pos : 149.1 /12 D emontage, Ents orgung/Demontage und Ents orgung --nur Titel-- @ 0\mod_1275493320296_968.doc @ 1300 @ 32222221231222222123333332 @ 1 1.10 Disassembly and Disposal Pos : 149.2 /12 D emontage, Ents orgung/Ents orgung @ 0\mod_1275493372843_968.doc @ 1301 @ 13222222122212 @ 1 Instruction Manual CSM722 SIFTER Order number: PTI003990-M22320, Doc-ID: APH 20-11-13 Page 47 of 101 Appendix The device is a robust unit with a long service life. However, if disposal is necessary follow the instructions in this section. Pos : 149.3 /12 D emontage, Ents orgung/Sic herheits hinweise zur Demontag e und Ents orgung --nur Titel-- @ 0\mod_1275493405218_968.doc @ 1302 @ 333221232122222212233 @ 1 1.10.1 Safety instructions for disassembly and disposal Pos : 149.4 /12 D emontage, Ents orgung/Sic herheits hinweise zur Demontag e und Ents orgung @ 0\mod_1275493444828_968.doc @ 1303 @ 222 @ 1 The instructions in this section must be observed in addition to all instructions in "Safety". Pos : 149.5 /11 Wartung/El ektrisc her Strom ( GEF AHR) @ 0 \mod_1275488356875_968.doc @ 1259 @ 3122222212 @ 1 Danger from electrical current DANGER Danger of death from electrical current Contact with live parts is an immediate risk of death. Live electrical components may move uncontrolled and cause very serious injury. Before starting work switch off power supply and lock to prevent unauthorised reactivation. All work on electrical systems must be conducted by authorised electrical technicians only. Pos : 149.6 /07 Installation/Weitere Gefahren ( WARNUNG) @ 0\mod_1275479933812_968.doc @ 1134 @ 3333333122222212 @ 1 Additional dangers WARNING Danger of injury by pneumatic energy! Danger of injury by moving parts! Danger of burns from hot surfaces! Danger of injury when lifting loads! Danger to health from hazardous substances! Danger of injury from improper working! Observe the instructions in "Safety". Wear suitable personal protective equipment. Observe general occupational health and safety regulations. Pos : 149.7 /07 Installation/Pers onal @ 0\mod_1275480062812_968.doc @ 1136 @ 2212212222221223 @ 1 Personnel All work must be carried out by appropriately qualified technicians only. Pos : 149.8 /08 Erstinbetriebnahme/Persönlic he Sc hutz ausr üstung @ 0\mod_1275484424859_968.doc @ 1211 @ 332212321222222122 @ 1 Personal protective equipment Wear suitable personal protective equipment. Check with on-site supervisors whether additional personal protective equipment, such as a respirator, is required. Pos : 150.1 /07 Installation/Explosi onsschutz, Z ündq uellen ver meiden (EX) AT EX @ 0\mod_1275480017328_968.doc @ 1135 @ 12 @ 1 Pos : 152.1 /13 Anhang/Anhang --nur Titel-- @ 0\mod_1275494108468_968.doc @ 1316 @ 333333232333333121222222 @ 1 1.11 Appendix Pos : 152.2 /13 Anhang/C hec kliste vor Pr obelauf --nur Titel-- @ 0\mod_1275494138234_968.doc @ 1317 @ 21222222233333321 @ 1 1.11.1 Checklist for test run Pos : 152.3 /13 Anhang/Misc her/Chec kliste vor Probel auf (HIN WEIS) @ 0\mod_1275494220015_968.doc @ 1318 @ 212 @ 1 Page 48 of 101 Instruction Manual CSM722 SIFTER Order numberPTI003990-M22320, Doc-ID: APH 20-11-13 NOTE! Copy the checklist and tick off items on the copy. checked by check completed Technician there are no foreign bodies in the device. Technician the minimum clearance between the paddles and sieve hose or screen is correct. Electrical technician power supply feeds are connected and fused in compliance with local regulations. Technician there is a directional arrow on the drive. Technician the direction of rotation of the shaft assembly is according to the arrow on the drive. Electrical technician the device is earthed in accordance with regulations. Technician Connection lines are tight. Pos : 152.4 /13 Anhang/Z ugehörige Dokumente --nur Titel-- @ 0\mod_1275494265828_968.doc @ 1319 @ 221213 @ 1 1.11.2 Associated documents Pos : 153 /13 Anhang/Z ugehörige Dokumente P+I Diagramm @ 4\mod_1326376219875_968.doc @ 24897 @ 33333312 @ 1 P+I Diagram Installation drawings List of electrical equipment OEM Documentation Confirmation of Manufacturer Declaration of Incorperation Pos : 154 /13 Anhang/Z ugehörige Dokumente Installati ons Z eichnungen @ 4\mod_1320539670660_968.doc @ 23260 @ 2333333121222222 @ 1 Pos : 155 /13 Anhang/Z ugehörige Dokumente El ektr o Appar ateliste @ 4\mod_1320539673035_968.doc @ 23274 @ 21222222 @ 1 Pos : 156 /13 Anhang/Z ugehörige Dokumente Dokumentation OEM @ 4\mod_1320539671957_968.doc @ 23267 @ 212 @ 1 Pos : 157 /13 Anhang/Z ugehörige Dokumente Hersteller beschei nigung @ 4\mod_1328535499630_968.doc @ 25490 @ 1212 @ 1 Pos : 158 /13 Anhang/Z ugehörige Dokumente Konfor mitäts er klär ung @ 4\mod_1320540344953_968.doc @ 23295 @ 21222222 @ 1 === Ende der Liste für T extmar ke Inhalt === 2 Instruction Manual CSM722 SIFTER Order number: PTI003990-M22320, Doc-ID: APH 20-11-13 Page 49 of 101 Technical Data Page 50 of 101 Instruction Manual CSM722 SIFTER Order numberPTI003990-M22320, Doc-ID: APH 20-11-13 Technical Data 3 Technical Data Pos : 40.2 /04 Tec hnische D aten/Misc her/M ass blatt -- nur Ti tel-- @ 0\mod_1275472816093_968.doc @ 1064 @ 2122 @ 1 2.1 Performance Pos : 40.8 /04 Tec hnische D aten/Misc her/GMS/Leistungswerte ( mit r ed. Drehz ahl) GMS 2800 AT EX @ 1\mod_1283525984961_968.doc @ 1847 @ 2222 @ 1 Nominal speed of drive Nominal speed of shaft assembly 1500 rpm (sync) 1000 rpm Pos : 40.9 /04 Tec hnische D aten/Misc her/Ansc hluss werte --nur Titel-- @ 0\mod_1275473439265_968.doc @ 1068 @ 22 @ 1 2.2 Connection values Pos : 40.10 /04 T ec hnisc he D aten/Mischer/GMS/Ansc hluss werte elektrisch 380V, 50Hz GMS 2800 @ 4\mod_1312442953781_968.doc @ 20753 @ 1221 @ 1 Electrical Voltage, Frequency Power consumption, nominal Motor power 400 V, 50 Hz 6A 2.2 kW Seal type Medium Purge gas pressure (reference value) Lip Process gas approx. 0.3 – 0.5 bar min. 11.5 Nm3/h Pos : 40.11 /04 T ec hnisc he D aten/Mischer/Ans chl uss werte Steuerl uft Luft 4 - 6 bar @ 0\mod_1275911415343_968.doc @ 1326 @ 22 @ 1 Pos : 40.12 /04 T ec hnisc he D aten/Mischer/Ans chl uss werte Pr ozessgas Luft 4 - 6 bar @ 0\mod_1275911493593_968.doc @ 1327 @ 11 @ Pos : 40.13 /04 T ec hnisc he D aten/Mischer/Ans chl uss werte Qualität Pr oz essgas @ 0\mod_1275473637390_968.doc @ 1069 @ 22 @ 1 Pos : 40.14 /04 T ec hnisc he D aten/Mischer/GMS/Ansc hluss wert Spülgas GM S 2800 @ 1\mod_1283928869421_968.doc @ 2040 @ 1 @ 1 Purge gas shaft seal for sifter Gas flow volume (depending on bulk material) Quality of process gas Recommendation for process gas in the food industry in accordance with VDMA 15390: Solid impurities: ISO 8573-1 Class 1 Humidity: ISO 8573-1 Class 3 – 4 Total oil content: ISO 8573-1 Class 1 Pos : 41.1 /04 Tec hnische D aten/Misc her/T ec hnische D aten --nur Titel-- @ 0\mod_1275472283015_968.doc @ 1063 @ 12 @ 1 Pos : 51.5 /04 Tec hnische D aten/Misc her/Betriebs beding ung en Mis chdaten @ 1\mod_1283527284094_968.doc @ 1863 @ 22 @ 1 Sifter Specification Machine Reference Number Design Throughput Duty M22320 in accordance with product specification Product Temperature Sifter Configuration Basket type Basket Segments Basket Restriction Screen Material Screen Aperture Shaft Configuration Instruction Manual CSM722 SIFTER Order number: PTI003990-M22320, Doc-ID: APH 20-11-13 Bolted Construction Positive Pitch Round hole Restricted End Ring Heavy Duty white nylon 500 Microns 2 by ½ legnths Page 51 of 101 Technical Data Shaft Speed Special Features Motor details 1500rpms n/a Manufacturer Designation – Serial number KW @ RPM Connection Full load current IP rating Atex rating Brooke Crompton WU-DA-100LSIE2 2.2 kw @ 1500rpm See nameplate 4.6A IP55 Safe Area Pos : 51.6 /04 Tec hnische D aten/Misc her/Produkt -- nur Ti tel-- @ 0\mod_1275474235187_968.doc @ 1072 @ 22 @ 1 2.3 Product Pos : 51.7 /04 Tec hnische D aten/Misc her/Produkt @ 0\mod_1275912606656_968.doc @ 1336 @ 22 @ 1 approved bulk density average particle size ds50 ≤ 1 kg/dm3 in accordance with product specification Pos : 51.8 /04 Tec hnische D aten/Misc her/Produkt weitere Eigensc haften @ 1\mod_1293178637543_968.doc @ 2998 @ 2222222 @ 1 The product must also have the following properties: non-caking dry free-flowing non-clumping non-setting not sticky product components do not react together chemically Pos : 51.9 /--Seitenumbr uch-- @ 0\mod_1275315941062_0.doc @ 1348 @ 2 @ 1 Pos : 51.10 /04 T ec hnisc he D aten/Mischer/Emissionen -- nur Ti tel-- @ 0\mod_1275474527828_968.doc @ 1074 @ 22 @ 1 2.4 Emissions Pos : 51.11 /04 T ec hnisc he D aten/Mischer/Emissionen GMS @ 4\mod_1308552129325_968.doc @ 12624 @ 22 @ 1 Noise emission during operation without bulk material < 80 db(A) Pos : 51.12 /04 T ec hnisc he D aten/Mischer/Schmi er mittel --nur Titel-- @ 0\mod_1275474746562_968.doc @ 1076 @ 2222222 @ 1 2.5 Lubricant Pos : 51.13 /04 T ec hnisc he D aten/Mischer/Schmi er mittel Lagerfett SKF LGFP2 @ 0\mod_1275912986046_968.doc @ 1340 @ 22 @ 1 Bearing grease SKF LGFP2 food compatible Pos : 51.14 /04 T ec hnisc he D aten/Mischer/Schmi er mitt el Lagerfett Hi nweis @ 0\mod_1275475057015_968.doc @ 1078 @ 2222222222 @ 1 The properties of the bearing grease can be found in the manufacturer's specifications. Use only food-compatible bearing grease. Pos : 51.15 /04 T ec hnisc he D aten/Mischer/Schmi er mittel Getri ebeöl DT E FM 220 U SD A H 1 GM S @ 4\mod_1314362509292_968.doc @ 20890 @ 122 @ 1 Pos : 52.1 /04 Tec hnische D aten/Misc her/Betriebs beding ung en -- nur Ti tel-- @ 0\mod_1275473856718_968.doc @ 1070 @ 22 @ 1 2.6 Operating conditions Pos : 52.2 /04 Tec hnische D aten/Misc her/Betriebs beding ung en Umg ebung @ 0\mod_1275912250593_968.doc @ 1331 @ 22 @ 1 Page 52 of 101 Instruction Manual CSM722 SIFTER Order numberPTI003990-M22320, Doc-ID: APH 20-11-13 Technical Data Environment Temperature range Relative humidity, maximum 10 – 40 °C 60 % Pos : 52.3 /04 Tec hnische D aten/Misc her/Betriebs beding ung en Produktr aum @ 0\mod_1275912333750_968.doc @ 1332 @ 2122222 @ 1 Product chamber Approved pressure in product chamber +/- 0 bar (pressureless) Pos : 52.4 /04 Tec hnische D aten/Misc her/Betriebs beding ung en Gerätedaten ATEX @ 1\mod_1283527103157_968.doc @ 1859 @ 21 @ 1 Device data Normal temperature in the area of the sifter shaft seals, maximum in operation without product Minimum clearance between blades and sieve hose or screen Electrical resistance (for electrostatic earth) < 90 ℃ 5 mm <106 ohms Pos : 52.5 /04 Tec hnische D aten/Misc her/Betriebs beding ung en Nor maltemperatur (HIN WEIS) @ 0\mod_1275474122078_968.doc @ 1071 @ 2 @ 1 NOTE The specification of the normal temperature is used to test whether the heat in the shaft seals and the bearings is in the normal range during commissioning Pos : 52.6 /04 Tec hnische D aten/Misc her/Betriebs beding ung en Mis chdaten @ 1\mod_1283527284094_968.doc @ 1863 @ 2 @ 1 Pos : 52.7 /--Seitenumbr uch-- @ 0\mod_1275315941062_0.doc @ 1348 @ 22 @ 1 Instruction Manual CSM722 SIFTER Order number: PTI003990-M22320, Doc-ID: APH 20-11-13 Page 53 of 101 3 Data Sheet and Sectional Arrangement 3 Data Sheet and Sectional Arrangement Pos : 40.3 /04 Tec hnische D aten/Misc her/GMS/Mas sbl att GM S 2800 ECD s pez . 31110419 @ 4\mod_1327564152216_968.doc @ 25221 @ 222 @ 1 Page 54 of 101 Instruction Manual CSM722 SIFTER Order numberPTI003990-M22320, Doc-ID: APH 20-11-13 3 Data Sheet and Sectional Arrangement Pos : 40.5 /04 Tec hnische D aten/Misc her/M ass e und Gewichte --nur Titel-- @ 0\mo d_1275473242187_968.doc @ 1066 @ 222 @ 1 Pos : 40.6 /04 Tec hnische D aten/Misc her/GMS/Mas se und Gewic hte GM S 2800 ECD @ 4 \mod_1308550212150_968.doc @ 12620 @ 2222 @ 1 : 40.7 /04 T ec hnisc he D aten/Mischer/Leis tungs werte -- nur Ti tel-- @ 0\mod_1275473336546_968.doc @ 1067 @ 222 @ 1 Instruction Manual CSM722 SIFTER Order number: PTI003990-M22320, Doc-ID: APH 20-11-13 Page 55 of 101 3 Data Sheet and Sectional Arrangement 3.1 Dimensions and weight Pos : 40.6 /04 Tec hnische D aten/Misc her/GMS/Mas se und Gewic hte GM S 2800 ECD @ 4 \mod_1308550212150_968.doc @ 12620 @ 2222 @ 1 Weight Length Width Height Page 56 of 101 ~ 120 kg ~ 1500 mm ~ 700 mm ~ 500 mm Instruction Manual CSM722 SIFTER Order numberPTI003990-M22320, Doc-ID: APH 20-11-13 3 Data Sheet and Sectional Arrangement Instruction Manual CSM722 SIFTER Order number: PTI003990-M22320, Doc-ID: APH 20-11-13 Page 57 of 101 Basket Assembly 4 Basket Assembly Page 58 of 101 Instruction Manual CSM722 SIFTER Order numberPTI003990-M22320, Doc-ID: APH 20-11-13 Basket Assembly 4.1 Operation Instruction Manual CSM722 SIFTER Order number: PTI003990-M22320, Doc-ID: APH 20-11-13 Page 59 of 101 Basket Assembly Page 60 of 101 Instruction Manual CSM722 SIFTER Order numberPTI003990-M22320, Doc-ID: APH 20-11-13 Basket Assembly 4.2 Basket removal and assembly The basket should be inspected regularly (at least daily) in situ and removed and fully inspected at least weekly. Pos : 138.5 /11 Wartung/R einigung/Sc häden durc h unsac hgemäss e R einigung (VORSICHT) @ 0 \mod_1275489489000_968.doc @ 1277 @ 323 @ 1 CAUTION! Care must be taken not to damage the sieve hose on the bulkheads when removing the basket. This is very important as the slightest damage, particularly on fine sieve hoses, will lead to catastrophic failure during production use 1. When replacing the basket the end ring flange has to be located on the location pin and fixing studs, the flange mounted flat to the bulkhead and the two tommy bars tightened sufficiently to secure the basket tightly. 2. The basket assembly is pre-set on assembly so that the correct sealing is obtained between the basket seal and the two bulkheads at the sifter 3. The basket setting can be checked by testing the rigidity of the assembly through the side door. Remove the side door (See Section 6), grip the drive end of the basket and pull from side to side to detect if fixed securely 4. Screen material shall be checked to comply with the technical details in Section 2 . 4.2.1 Set sieve hose on basket rings 2 to 3 mm The sieve hose should be fitted with a small overlap of cuff material extended over the basket rings (approximately 2 to 3 mm). Instruction Manual CSM722 SIFTER Order number: PTI003990-M22320, Doc-ID: APH 20-11-13 Page 61 of 101 Basket Assembly With the hose correctly positioned on the rings, the jubilee clips must be tightened securely using a spanner. (Gericke recommended the use of Hi-Torque band clips).. Pos : 138.5 /11 Wartung/R einigung/Sc häden durc h unsac hgemäss e R einigung (VORSICHT) @ 0 \mod_1275489489000_968.doc @ 1277 @ 323 @ 1 CAUTION! Sieve hoses must be fitted with the welded or stitched seam at the top of the basket assembly when fitted into the machine. Care must also be taken to ensure that sieve hoses are not twisted prior to tensioning. Direction of rotation on stitched seamed hoses must be matched to the shaft rotation. 1. Before tensioning the basket using the tensioning nuts, ensure that seal and gasket are all correctly seated. Direction of Rotation CAUTION! Tension the screen using the tensioning nuts. Each nut should be tightened sequentially a little bit at a time so the hose is tensioned evenly. The recommended basket tension is achieved by stretching the sieve hose approximately 3.5% of its free length. Page 62 of 101 Instruction Manual CSM722 SIFTER Order numberPTI003990-M22320, Doc-ID: APH 20-11-13 Basket Assembly Instruction Manual CSM722 SIFTER Order number: PTI003990-M22320, Doc-ID: APH 20-11-13 Page 63 of 101 Door Assembly (End) Pos : 54.2 /05 Aufbau und F unkti on/Übersic ht --nur Titel-- @ 0\mod_1275475196437_968.doc @ 1080 @ 221 @ 1 Pos : 54.1 /05 Aufbau und F unkti on/Aufbau und Funkti on --nur Titel-- @ 0\mod_1275475158968_968.doc @ 1079 @ 22222122 @ 1 5 Door Assembly (End) Page 64 of 101 Instruction Manual CSM722 SIFTER Order numberPTI003990-M22320, Doc-ID: APH 20-11-13 Door Assembly (End) 5.1 Operation Instruction Manual CSM722 SIFTER Order number: PTI003990-M22320, Doc-ID: APH 20-11-13 Page 65 of 101 Door Assembly (End) 5.2 Removal of guards (non-drive end) Release the setscrews and draw off the guard as shown in the drawing. Always place the guard where it cannot be damaged or fall and injure someone. Pos : 138.5 /11 Wartung/R einigung/Sc häden durc h unsac hgemäss e R einigung (VORSICHT) @ 0 \mod_1275489489000_968.doc @ 1277 @ 323 @ 1 DANGER … Guards must always be fitted correctly before the Sifter is started. 5.3 Removal of end door Unscrew the hand knobs and withdraw the door as shown. Always place the door where it cannot be damaged or fall and injure someone. Note On re-assembly it is important that the door gasket is seated properly and lies flat prior to door fitment. Locate the end door over the shaft and partially push on. The door and shaft assembly may have to be lifted slightly to locate the door onto the pins or studs fitted to the casing. With the door correctly positioned the nuts can be replaced and tightened. Check that the end door is seated firmly and that there are no gaps between the door and the gasket and casing 5.4 Removal of non-drive end bearing Non-drive end bearings may be removed whilst the machine is assembled. If the shaft assembly is still in position then the seal housing must be slackened before the bearing is unfastened or seal damage may result.. Spring Plunger A spring plunger is screwed into the bearing collar to ensure that the inner race of the bearing rotates with the shaft. The spring plunger has been set so that when fully retracted it allows the shaft access to the bearing and the end door can initially be replaced in any position. Position the end door over the locating studs with the switch key aligned to the switch and replace and tighten the hand knobs. The spring plunger will find the keyway as the shaft rotates driving the inner race with the shaft. Page 66 of 101 Instruction Manual CSM722 SIFTER Order numberPTI003990-M22320, Doc-ID: APH 20-11-13 Door Assembly (End) Instruction Manual CSM722 SIFTER Order number: PTI003990-M22320, Doc-ID: APH 20-11-13 Page 67 of 101 Door Assembly (Side) 6 Door Assembly (Side) Page 68 of 101 Instruction Manual CSM722 SIFTER Order numberPTI003990-M22320, Doc-ID: APH 20-11-13 Door Assembly (Side) 6.1 Operation Instruction Manual CSM722 SIFTER Order number: PTI003990-M22320, Doc-ID: APH 20-11-13 Page 69 of 101 Drive Assembly 7 Drive Assembly Page 70 of 101 Instruction Manual CSM722 SIFTER Order numberPTI003990-M22320, Doc-ID: APH 20-11-13 Drive Assembly 7.1 Operation Instruction Manual CSM722 SIFTER Order number: PTI003990-M22320, Doc-ID: APH 20-11-13 Page 71 of 101 Drive Assembly 7.2 Removal of drive end bearing Drive end bearings can only be removed when the shaft assembly has been removed. Follow the previous procedures to remove the shaft assembly and the drive end guards The standard CSM722 has only a single bearing at the drive end. It is held in position by four sets of nuts, bolts and washers. Bearings are positioned and aligned when assembled and should not be moved unless bearings are to be replaced. . Pos : 138.5 /11 Wartung/R einigung/Sc häden durc h unsac hgemäss e R einigung (VORSICHT) @ 0 \mod_1275489489000_968.doc @ 1277 @ 323 @ 1 Drive end bearings can only be removed when the shaft assembly has been removed. Follow the previous procedures to remove the shaft assembly and the drive end guards The CSM722 Sifter has a single bearing at the drive end and has two grub screws. Grub screws must be loosened before the shaft assembly can be removed. NOTE The shaft has been dimpled and the grub screws may need backing off to be clear. 7.3 Guards DANGER … Guards must always be fitted correctly before the Sifter is started. Page 72 of 101 Guards should be replaced by following the disassembling procedure in the reverse order. Instruction Manual CSM722 SIFTER Order numberPTI003990-M22320, Doc-ID: APH 20-11-13 Drive Assembly 7.4 Installation instruction for synchronous belt drive Synchronous belt drives operate by positive meshing and do not require high initial belt tensions. For optimum belt performance, however, belts should be installed with pre-tension suitable for the envisaged drive duty. The appropriate level of pre-tension will be as the table below, where the deflection is measured at the middle point of the belt and the force applied at right angles evenly across the belt width. CSM722 5 mm Deflection 18 N Force In practice belts should be installed at a tension sufficient to prevent tooth jumping under the most severe load conditions that the drive is likely to endure. NOTE Excessive belt tension will reduce belt and bearing lives and may increase drive noise levels. 7.5 Pulley alignment Misalignment of drive pulleys results in unequal tension across the belt width and extreme edge wear. Consequently, pulley alignment should be proved using a straightedge and checking for parallelism. Misalignment on any synchronous drive should not exceed ¼° angular or 5 mm/metre centre distance parallel. Parallel Misalignment Angular Misalignment Instruction Manual CSM722 SIFTER Order number: PTI003990-M22320, Doc-ID: APH 20-11-13 Page 73 of 101 Drive Assembly 7.6 Taperlock Bush TO INSTALL Bush Size 1008 1108 1210 1610 1615 2012 2517 3020 3030 3525 1. Remove the protective coating from the bore and outside of bush, and bore of hub. After ensuring that the mating tapered surfaces are completely clean and free from oil or dirt, insert bush in hub so that holes line up. 2. Sparingly oil thread and point of grub screws, or thread and under head of cap screws. Place screws loosely in holes threaded in hub, shown thus in diagram. 3. Clean shaft and fit hub to shaft as one unit and locate in position desired, remembering that bush will nip the shaft first and then hub will be slightly drawn on to the bush. 4. Using a hexagon wrench tighten screws gradually and alternately until to torque shown in table below. 5. Hammer against large end of bush, using a block or sleeve to prevent damage. (This will ensure that the bush is seated squarely in the bore). Screws will now turn a little more. Repeat this alternate hammering and screw tightening once or twice to achieve maximum grip on the shaft. 6. If a key is to be fitted place it in the shaft keyway before fitting the bush. It is essential that it is a parallel key and side fitting only and has TOP CLEARANCE.. 7. After drive has been running under load for a short time, stop and check tightness of screws. 8. Fill empty holes with grease to exclude dirt. 4030 TO REMOVE Screw Tightening Torque (Nn) Qty 5.6 5.6 20 20 20 2 2 2 2 2 ¼" ¼" ⅜" ⅜" ⅜" 30 50 90 90 115 170 2 2 2 2 3 3 /16" ½" ⅝" ⅝" ½" ⅝" 1. Slacken all screws by several turns, remove one or two according to number of jacking off holes shown thus ● in diagram. Insert screws in jacking off holes after oiling thread and point of grub screws or thread and under head of cap screws. 2. Tighten screws alternately until bush is loosened in hub and assembly is free on the shaft. 3. Remove assembly from shaft. . Screw Details Size (BSW) 7 Large End Diameter (mm) 35.0 38.0 47.5 57.0 57.0 70.0 85.5 108 108 127 146 Approx. Mass (kg) 0.1 0.1 0.2 0.3 0.5 0.7 1.5 2.7 3.6 3.8 7.7 Page 74 of 101 Instruction Manual CSM722 SIFTER Order numberPTI003990-M22320, Doc-ID: APH 20-11-13 Drive Assembly Instruction Manual CSM722 SIFTER Order number: PTI003990-M22320, Doc-ID: APH 20-11-13 Page 75 of 101 Seal Assembly 8 Seal Assembly Page 76 of 101 Instruction Manual CSM722 SIFTER Order numberPTI003990-M22320, Doc-ID: APH 20-11-13 Pos : 54.2 /05 Aufbau und F unkti on/Übersic ht --nur Titel-- @ 0\mod_1275475196437_968.doc @ 1080 @ 221 @ 1 8.1 Seals Drive end seals can only be removed when the shaft assembly has been removed. The seal housing retains the seals in various configurations. Bearings should be left in position wherever possible so that positional alignment of the shaft assembly can be maintained. The machine supplied may be fitted with an air purge and lip seal arrangement. The air purge seal works by providing an air barrier to product motion. Such a barrier can be simply achieved by putting air onto the standard lip seal arrangement. CAUTION! Before seals are fitted into our Sifting Machines, the spring steel tension springs are removed. A tight fit onto the shaft tends to reduce seal life and score the shaft CAUTION! When air purge seals are fitted compressed air must always be on whilst the machine is running or damage to the seal will occur.. General pressure settings should be added to the pressure inside the Sifter. This type of seal will only be effective if the external pressure is greater than the internal pressure. The pressure to be applied to the seal should be 0.2 - 0.5 BAR g ABOVE the internal pressure of the Sifter when in use and will be set up at commissioning. CAUTION! Where airflow is at risk of failure use an airflow monitor and stop the machine in the event of loss of air .. Instruction Manual CSM722 SIFTER Order number: PTI003990-M22320, Doc-ID: APH 20-11-13 Page 77 of 101 Shaft Assembly 9 Shaft Assembly Page 78 of 101 Instruction Manual CSM722 SIFTER Order numberPTI003990-M22320, Doc-ID: APH 20-11-13 Shaft Assembly Instruction Manual CSM722 SIFTER Order number: PTI003990-M22320, Doc-ID: APH 20-11-13 Page 79 of 101 Shaft Assembly 9.1 Removal of shaft assembly DANGER … Grip the shaft assembly securely and withdraw from the Sifter. When removing the shaft assembly from the Sifter, it is important to follow safe lifting procedures to protect the remover. Attention should be paid to the chart below showing approximate shaft assembly weights. 9.2 Remove the end door, and the basket. This will stop the shaft damaging the screen. Shaft assembly and drive All paddle blades are set and statically balanced at our works prior to despatch. Altering the radial position of the blades may adversely affect the smooth vibration free running of the machine so care is required when re-placement blades are fitted OR any adjustment is required to be carried out. The standard radial clearance between the paddle blades and the internal diameter of the basket rings on which the sieve hoses are fitted is 5 to 10 mm on ALL sizes of machines. On standard shaft assemblies, the paddle blades are fixed in position on the paddle bosses with nuts and bolts. The blade position can be altered by slackening the nuts and bolts and sliding the blades on their mounting slots. These slots are designed so that they can never extend into the sieve hose and basket rings. Where blades are re-assembled they must be tightened using a torque spanner to 25.7m for M8 Bolts. For different applications blade settings may vary to give optimum sieving efficiency, however screen life may be affected if blade clearance is reduced. Experience with the product in question is the only way to determine optimum blade settings. When paddle bosses and feed worm have been removed care must be taken to ensure that they are put back to their original position. The fixing screws fit into dimples machined into the shaft. When fixing screws are replaced they should be returned to their original dimples. When the shaft assembly has been replaced into the machine, the drive end bearings should be grub screwed back onto the shaft using the existing dimples. Page 80 of 101 Instruction Manual CSM722 SIFTER Order numberPTI003990-M22320, Doc-ID: APH 20-11-13 Shaft Assembly Fully welded shaft assemblies are factory set to suit the application and cannot be adjusted. The CSM MK II Sifters are all driven by standard electric motors through timing belt reduction drives. Integrity of welding or bolted construction should be checked regularly and not less than on a weekly basis. This shall include the paddle bosses, paddle blades and feed worm Pos : 54.2 /05 Aufbau und F unkti on/Übersic ht --nur Titel-- @ 0\mod_1275475196437_968.doc @ 1080 @ 221 @ 1 Instruction Manual CSM722 SIFTER Order number: PTI003990-M22320, Doc-ID: APH 20-11-13 Page 81 of 101 Additional Features 10 Additional Features Page 82 of 101 Instruction Manual CSM722 SIFTER Order numberPTI003990-M22320, Doc-ID: APH 20-11-13 Additional Features Instruction Manual CSM722 SIFTER Order number: PTI003990-M22320, Doc-ID: APH 20-11-13 Page 83 of 101 Certification Pos : 54.2 /05 Aufbau und F unkti on/Übersic ht --nur Titel-- @ 0\mod_1275475196437_968.doc @ 1080 @ 221 @ 1 11 Certification Page 84 of 101 Instruction Manual CSM722 SIFTER Order numberPTI003990-M22320, Doc-ID: APH 20-11-13 Certification Pos : 54.2 /05 Aufbau und F unkti on/Übersic ht --nur Titel-- @ 0\mod_1275475196437_968.doc @ 1080 @ 221 @ 1 Instruction Manual CSM722 SIFTER Order number: PTI003990-M22320, Doc-ID: APH 20-11-13 Page 85 of 101 Spares List 12 Spares List Recommended spare parts (Consumables) Machine Model: CSM722 MkII Machine Serial Number: M22320 We recommend that you hold the following component stock for one year normal running. Quantities are for guidance only; actual usage will depend on the sifting application and operating hours. When ordering spare parts, please quote the model and serial number of the sifter. Description Part Number Basket frame assembly Perforated plate screen 2000 micron round hole Fan assembly – Restricted End Silicon basket inlet seal Gasket End Door - WFQR Hand Knob - Doors Gasket – Side door Self aligning bearing M6 spring plunger for non drive end bearing Shaft seal Shaft seal spacer Anti Static Belt (Drive) Pulley (Drive) Pulley (Driven) Taper Lock Bush (Drive) Taper Lock Bush (Driven) End door safety switch with 90 degree actuator Sid door safety switch with flat actuator 20111675AS 20111204BS 20111689AX 201112280C 20111035BB 20000F500Y 20111417OB 20000B170Y 20000F510Y 20000S560Y 201116210Y 20000A090Y 20000P150Y 20000P160Y 20000T100Y 20000T120Y 20000L170Y 20000L180Y Qty per Machine 1 1 1 1 1 4 1 2 1 4 2 1 1 1 1 1 1 1 In addition, the following parts may be required from time to time during the operational life of the machine: Description Shaft Stainless steel Paddle Blade Stainless steel Paddle Boss assembly Seal Housing – stainless steel Motor, 3.0kw Page 86 of 101 Part Number 20111033CS 20111066BX 201111320S 20111085DS Q22320 Qty per Machine 1 4 2 2 1 Instruction Manual CSM722 SIFTER Order numberPTI003990-M22320, Doc-ID: APH 20-11-13 Spares List Instruction Manual CSM722 SIFTER Order number: PTI003990-M22320, Doc-ID: APH 20-11-13 Page 87 of 101 Service Contract Pos : 54.2 /05 Aufbau und F unkti on/Übersic ht --nur Titel-- @ 0\mod_1275475196437_968.doc @ 1080 @ 221 @ 1 13 Service Contract Gericke can also provide Service Contracts For information, please contact our Sales team in your territory Page 88 of 101 Instruction Manual CSM722 SIFTER Order numberPTI003990-M22320, Doc-ID: APH 20-11-13 Service Contract Typical Proposal For Service Contract On CSM MKII Sifter Client: Issue 1 Instruction Manual CSM722 SIFTER Order number: PTI003990-M22320, Doc-ID: APH 20-11-13 Page 89 of 101 Service Contract PROPOSAL OUTLINE The unit considered within this proposal is a CSM MK II Sifter, manufactured and supplied by Gericke Ltd. It is proposed to carry out regular services visits at periods to be determined to assess and adjust machinery as the attached schedule. It is suggested these visits be annual. It is intended that the Gericke Service Engineer would carry out the following actions and duties during any visit: Attend site and meet a representative of the client. Discuss any problems experienced since last visit by a Gericke Engineer Assess the unit and inspect generally in line with the attached schedule. An addendum section is included for additional comments from observations made during the visit. Carry out any adjustments/repairs that can practicably be completed during the visit. Advise of any problems or potential problems found during visit Prepare and submit report to the client with costed recommendations for any further remedial work and component parts considered necessary which could not be completed during the visit The above works would be carried out over one working day (excluding travelling to site) based on the assumption that free access will be made available to the Gericke Engineer during his planned visit. No allowance has been made for the supply of replacement parts within this scope of supply but the engineer will carry a small number of regularly used components for use as required. However, it is recommended the client carries a full set of spare parts as indicated in the Spare Parts schedule within the manual. No allowance has been made for inspection of control components within the control panel. Total package cost for above single visit is dependent on the location of the client’s plant and a formal offer would be made as requested. Costs for air fares or ferry crossing and local travel would be charged at cost plus 10% based on the most economical rate available at the time. Additional work carried out at the time of visit at the request of the client would be charged in accordance with our Standard rates for Service Engineers Page 90 of 101 Instruction Manual CSM722 SIFTER Order numberPTI003990-M22320, Doc-ID: APH 20-11-13 Service Contract Item Action Frequency Comments from Visit 1.0 Sifter 1.1 External 1.1.01 Check operation of side door Each Visit 1.1.02 Check safety interlock Each Visit 1.1.03 1.1.04 Check operation of end door Check Safety Interlock Each Visit Each Visit 1.1.05 Check drive end bearings for signs of failure Each Visit 1.1.06 Check drive end seals for signs of failure Each Visit 1.1.07 Each Visit 1.1.08 1.1.09 Check non drive end bearings for signs of failure Check non drive end seals for signs of failure Check drive belt for signs of failure 1.1.10 Check operation of level probes where fitted Each Visit 1.2 Internal Each Visit Each Visit 1.2.1 Remove shaft assembly, check balance Each Visit 1.2.2 Check shaft assembly for wear Each Visit 1.2.3 Each Visit 1.2.4 1.2.5 Check infeed scroll for product build up and security Check screen for correct tension and signs of failure Check screen basket for security 1.3 General Each Visit Each Visit 1.3.2 Discuss with client operation and equipment awareness Carry out any training deemed necessary 1.3.3 If possible, watch unit in operation 2.0 Addendums 1.3.1 Each Visit As Necessary As Practical Instruction Manual CSM722 SIFTER Order number: PTI003990-M22320, Doc-ID: APH 20-11-13 Page 91 of 101 Service Contract Page 92 of 101 Instruction Manual CSM722 SIFTER Order numberPTI003990-M22320, Doc-ID: APH 20-11-13 Proprietary Equipment os: 54.2 /05 Aufbau und F unktion/Ü bersic ht --nur Titel-- @ 0\mod_1275475196437_968.doc @ 1080 @ 221 @ 1 14 Proprietary Equipment Instruction Manual CSM722 SIFTER Order number: PTI003990-M22320, Doc-ID: APH 20-11-13 Page 93 of 101 Proprietary Equipment Page 94 of 101 Instruction Manual CSM722 SIFTER Order numberPTI003990-M22320, Doc-ID: APH 20-11-13 Proprietary Equipment 14.1 Safety switches Instruction Manual CSM722 SIFTER Order number: PTI003990-M22320, Doc-ID: APH 20-11-13 Page 95 of 101 Elf & Cadet 3 Installation Instructions Installationsanleitung Notice d'installation Istruzioni per l'installazione Instrucciones de instalación Bei der Installation müssen die im Folgenden beschriebenen Anweisungen und angegebenen Spezifikationen eingehalten werden. Zudem darf die Installation nur von entsprechend qualifizierten Mitarbeitern ausgeführt werden. Das Gerät darf nicht als mechanische Sperre verwendet werden. Schutzgittersperren und leitvorrichtungen müssen angebracht werden. Werden die empfohlenen Wartungsanweisungen nicht eingehalten, entfällt die Gewährleistung. ACHTUNG: Ersatzbetätiger können die Integrität von Sicherheitssystemen beeinträchtigen. Körperverletzungen oder Tod sowie Sachschäden oder wirtschaftliche Verluste können die Folge sein. Es sind geeignete Bedienungselemente, Arbeitsabläufe und alternative Schutzmaßnahmen vorzusehen, um ihre Verwendung und Verfügbarkeit zu steuern. Installation must be in accordance with the following steps and stated specifications and should be carried out by suitably competent personnel. The unit is not to be used as a mechanical stop. Guard stops and guides must be fitted. Adherence to the recommended maintenance instructions forms part of the warranty. ATTENTION: The presence of spare actuators can compromise the integrity of safety systems. Personal injury or death, property damage or economic loss can result. Appropriate management controls, working procedures and alternative protective measures should be introduced to control their use and availability. WARNING: Do not defeat, tamper, remove or bypass this unit. Severe injury to personnel could result. WARNUNG: Nehmen Sie niemals Eingriffe am Gerät vor, und zerlegen, entfernen oder überbrücken Sie das Gerät nicht. Andernfalls können schwere Körperverletzungen die Folge sein. L'installation doit être effectuée par un personnel qualifié conformément aux étapes et aux spécifications suivantes. Cet interrupteur ne doit pas être utilisé comme un arrêt mécanique. Installer des butées de porte et des dispositifs de guidage. Le respect des instructions de maintenance recommandée est l'une des conditions de la garantie. ATTENTION: la présence d'actionneurs supplémentaires peut compromettre l'intégrité des systèmes de sécurité et entraîner des blessures pouvant être mortelles, des dégâts matériels ou des pertes financières. Des contrôles de gestion, des procédures de travail, ainsi que des mesures de protection alternatives appropriés doivent être mis en place pour en contrôler l'utilisation et la disponibilité. Le operazioni di installazione devono essere eseguite da personale competente conformemente alle fasi qui di seguito illustrate nonché alle specifiche stabilite. L'unità non va utilizzata come fermo meccanico. È necessario accoppiare i fermi e le guide della protezione. Il rispetto delle istruzioni di manutenzione raccomandate costituisce parte della garanzia. ATTENZIONE: la presenza di attuatori di riserva può compromettere l'integrità dei sistemi di sicurezza. Pericolo di infortuni o morte, di danni a oggetti o di perdite economiche. È opportuno svolgere adeguati controlli di gestione, procedure di lavoro e adottare altre misure di sicurezza appropriate per controllarne l'uso e la disponibilità. AVERTISSEMENT: ne pas entraver le fonctionnement de cet interrupteur, ne pas le modifier, le retirer ni le contourner au risque de s'exposer à de graves blessures. ATTENZIONE: non forzare, manomettere, rimuovere o bypassare questa unità. Pericolo di gravi lesioni alle persone. @ZããEáåF Elf OREMKVUF PEMKNOF TREOKVRF NOKREMKQVF OVENKNQF QKREMKNUF QEMKNSF ADVERTENCIA: No cambie ni manipule indebidamente, ni desmonte u omita esta unidad. Esto podría causar lesiones personales graves. jQ NPEMKRNF SEMKOQF NOEMKQTF La instalación debe realizarse según los pasos siguientes y las especificaciones establecidas, y debe ser realizada por personal debidamente capacitado. La unidad no debe usarse como dispositivo de paro mecánico. Los dispositivos de paros y guías de la guarda deben estar instalados. El cumplimiento de las instrucciones de mantenimiento recomendadas forma parte de la garantía. ATENCIÓN: La presencia de accionadores adicionales puede comprometer la integridad de los sistemas de seguridad. Pueden ocurrir lesiones personales o la muerte, daños materiales y pérdidas económicas. Deben introducirse controles de administración apropiados, procedimientos de trabajo y medidas de protección alternativas a fin de controlar su uso y disponibilidad. NREMKVUF NTKREMKSVF OREMKRVF Cat. No: 440K-A21014 QEMKNSF OñjQ QKREMKNUF NñjNS TKREMKPF PEMKNOF OVENKNQF OQEMKVQF UKTREMKPQF UEMKPNF PEMKNOF PQKRENKPSF PSENKQOF NPEMKRNF NUEMKTNF @ZããEáåF NSKREMKSRF NOKR EMKQVF SEMKOQF OPEMKVNF NUKOREMKTOF Cadet 3 jQ NEMKMQF VMKREPKRSF NO EMKQTF PEMKNOF PUKQENKRNF Cat. No: 440K-A21006 PSKQENKQPF NQEMKRRF UKREMKPPF QKREMKNUF OñjQ QEMKNSF QMENKRTF NOEMKQTF OREMKVUF OMEMKTVF OOEMKUTF NP EMKRNF PNENKOOF PQKQENKPRF NPEMKRNF Cat. No: 440K-A21030 QEMKNSF PEMKNOF OREMKVUF QMENKRTF RRKREOKNVF NRKREMKSNF PMKQENKOF OREMKVUF QEMKNSF NP EMKRNF QKREMKNUF NñjNS NPKREMKRPF ^ a ` MKUk•ãETKMUäÄ•áåF _ OñjQ NKQk•ã ENOKPVäÄ•áåF NñjNS OñjR Nãã OKRãã Sãã TKRãã Nãã OKRãã Cat. No: 440K-A21030 OjRñPNKTãã MKUk•ãETKMUäÄ•áåF OjRñOUKTãã OñjR NKQk•ãENOKPVäÄ•áåF OQ OP OO ON PQ PP PO PN NO NN NO NN OO ON OO ON NO NN NO Elf Elf Q Q P OQ OP NO NN O Q N P OO ON NO NN O N O N P Q P Q Elf QD NNLNO OPLOQ S PKU QKO Z Z NNLNO ONLOO S Q Z Z Elf O S N R PP OO ON NO NN N O P Q S O R N P Mãã PKU NNLNO ONLOO PPLPQ QKR ON NO NN P O N R S P Q Cadet 3 QD PKU NNLNO ONLOO PPLPQ PKP Z Z Cadet 3 PN OO O Q Mãã PO N R S Cadet 3 QD Z Z Elf Cadet 3 PQ Elf QD Mãã NN Cadet 3 Mãã PKU NNLNO ONLOO PNLPO Z Z Cadet 3 440K-A21014 150 mm 150 mm 150 mm 200 mm 440K-A21006 150 mm 150 mm 150 mm 200 mm 440K-A21030 150 mm 60 mm 60 mm 200 mm Cadet 3 Mãã Check the machine is isolated and stopped whenever the interlocked guard door is open. IMPORTANT: After installation and commissioning, the actuator, switch and switch lid fixing screws should be coated with tamper evident varnish or similar compound. Maintenance Every Week Check alignment of actuator to switch and the correct operation of the switching circuit. Also check for signs of abuse or tampering. Inspect the switch casing & actuator for damage. Replace if apparent. At least every 6 months Isolate all power! Remove the lid & end cover. Inspect all terminals for tightness. Clean out any accumulation of fine dirt etc. Check for any sign of wear or damage, e.g. actuator wear, cam assembly wear, contact oxidisation and replace if apparent. Replace covers & tighten screws to specified settings. Reinstate the power & check for correct operation. Reapply tamper evident varnish or similar compound to fixings. Repair If there is any malfunction or damage, no attempts at repair should be made. The unit should be replaced before machine operation is allowed. DO NOT DISMANTLE THE UNIT. Information in regard to UL508 When used in elevated ambients, temperature rating of field wiring shall not be less than ambient. Electrical spec of rating code: A300 (Trojan 5 & Trojan 5 GD2) A600 (Trojan 6 & Trojan 6 GD2) Current, Max: 120V AC - make 60A, break 6A 240V AC - make 30A, break 3A Max. V/A: make 7200, break 720 Use copper conductors only. Use polymeric conduit only. End of line device. Wartung Jede Woche Ausrichtung des Betätigungselements mit dem Schalter und ordnungsgemäße Funktion des Schaltkreises kontrollieren. Außerdem auf Anzeichen von Missbrauch oder Manipulation untersuchen. Schaltergehäuse & Betätigungselement auf Beschädigungen kontrollieren. Falls welche festgestellt werden, ersetzen. Mindestens alle 6 Monate Alle Stromversorgungen trennen! Den Deckel und die Endabdeckung abnehmen. Alle Klemmen auf Festigkeit kontrollieren. Etwaige Ansammlungen feiner Schmutzteilchen etc. entfernen. Auf Anzeichen von Verschleiß und Beschädigungen untersuchen, z.B. Betätigungselementverschleiß, Nockenbaugruppenverschleiß oder Kontaktoxidation, und ersetzen, wenn diese aufgetreten sind. Abdeckungen wieder anbringen & Schrauben auf die vorgegebenen Werte anziehen. Strom wieder anschließen & auf ordnungsgemäßen Betrieb kontrollieren. Manipulationanzeigenden Lack oder ein ähnliches Mittel neu auf die Befestigungsteile auftragen. Reparatur Bei Fehlfunktion oder Beschädigung dürfen keine Reparaturversuche unternommen werden. Die Einheit muss ersetzt werden, bevor weiterer Betrieb der Maschine zugelassen wird. DIE EINHEIT DARF NICHT AUSEINANDERGEBAUT WERDEN. Information betreffs UL508 Bei Einsatz in höheren Umgebungstemperaturen darf die Nenntemperatur für die Feldverdrahtung nicht niedriger sein als die Umgebungstemperatur. Elektrische Spezifikation des Nennwertcodes: A600 Strom, Max: 120V AC - Schließen 60A, Öffnen 6A 240V AC - Schließen 30A, Öffnen 3A Max. V/A: Schließen 7200, Öffnen 720 Nur Kupferleiter benutzen. Nur polymerische Leitungsrohre benutzen. Einen Leitungsrohreingang für die Feldanschlüsse benutzen. Declaration of Conformity This is to declare that the products shown on this document conforms with the Essential Health and Safety Requirements (EHSR’s) of the European Machinery Directive (98/37/EC), the relevant requirements of the Low Voltage Directive (73/23/EEC as amended by 93/68/EEC). These products also conform to EN 60947-5-1, EN 1088, EN 292, EN 60204-1 and have Third Party Approval. Konformitätserklärung Hiermit wird bescheinigt, dass die auf diesem Dokument aufgeführten Produkte die grundlegenden Gesundheits- und Sicherheitsanforderungen (EHSR's) der Europäischen Maschinenrichtlinie (98/37/EC), die relevanten Anforderungen der Niederspannungsrichtlinie (73/23/EEC gemäß Änderung durch 93/68/EEC) erfüllen. Diese Produkte entsprechen auch EN 60947-5-1, EN 1088, EN 292, EN 60204-1 und sind für Dritte zugelassen. Kontrollieren, dass die Maschine stets isoliert und angehalten wird, wenn die abhängigkeitsgeschaltete Schutzvorrichtungstür geöffnet wird. WICHTIG: Nach der Installation und Inbetriebnahme sind die Betätigungselement-, Schalter- und SchalterdeckelBefestigungsschrauben mit manipulation-anzeigendem Lack oder einem ähnlichen Mittel zu versehen. Vérifier que la machine est isolée et arrêtée chaque fois que la porte de sécurité est ouverte. IMPORTANT : Après l'installation et la mise en service, les vis de fixation de l'actionneur, du commutateur et de son couvercle doivent être enduites de vernis témoin ou d'un produit similaire. Maintenance Toutes les semaines Vérifier l'alignement de l'actionneur et du commutateur et le bon fonctionnement du circuit de commutation. Chercher également les signes d'un éventuel tripatouillage. Vérifier l'état du boîtier et de l'actionneur. Remplacer si nécessaire. Tous les 6 mois au minimum Couper l'alimentation ! Déposer les couvercles. Vérifier le serrage de toutes les bornes. Éliminer la poussière, etc. Vérifier l'état et l'usure (usure de la came et de l'actionneur, oxydation des contacts, etc.) et remplacer si nécessaire. Remettre les couvercles en place en serrant les vis au couple spécifié. Rétablir l'alimentation et vérifier le bon fonctionnement. Appliquer sur les vis une nouvelle couche de vernis témoin ou de tout autre produit similaire. Réparation En cas de défaut de fonctionnement ou d'endommagement, ne jamais essayer de réparer le dispositif. Il doit être remplacé avant de remettre la machine en service. NE JAMAIS DÉMONTER LE DISPOSITIF. Informations relatives au dispositif UL508 Lorsque le dispositif est utilisé dans des températures ambiantes élevées, le câblage utilisé doit être prévu pour supporter des températures supérieures à celle de l'application. Spécifications électriques du code : A600 Tension maxi. : 120 V ca - fermeture 60 A, ouverture 6A 240 V ca - fermeture 30 A, ouverture 3A V/A maxi. : fermeture 7200, ouverture 720 Utiliser des conducteurs en cuivre uniquement. Utiliser des conduits en polymère uniquement. Utiliser une seule entrée pour la connexion sur site. Déclaration de conformité Nous déclarons par la présente que les produits mentionnés dans ce document sont conformes aux prescriptions essentielles d'hygiène et de sécurité de la directive européenne sur les machines (98/37/CEE), aux prescriptions pertinentes de la directive sur les basses tensions (73/23/CEE amendée par la directive 93/68/CEE). Ces produits sont également conformes aux normes EN 60947-5-1, EN 1088, EN 292, EN 60204-1 et bénéficient de l'homologation tierce partie. Controllare che la macchina sia isolata ed in condizione di arresto ogni volta che la porta di protezione interbloccata sia aperta. IMPORTANTE: dopo l'installazione e la messa in servizio, l'attuatore, l'interruttore ed il coperchio dell'interruttore devono essere spalmati con vernice tamper evident o una sostanza simile. Manutenzione Ogni settimana Controllare l'allineamento dell'attuatore rispetto all'interruttore e il corretto funzionamento del circuito di commutazione. Sincerarsi anche che non esistano indicazioni di un uso non autorizzato o di manomissioni. Esaminare l'involucro dell'interruttore e l'attuatore per verificare che non siano danneggiati. Sostituire in caso di danno. Almeno ogni 6 mesi Isolare tutte le alimentazioni di corrente! Rimuovere il coperchio e la calotta d'estremità. Controllare che tutti i morsetti siano ben stretti. Rimuovere ogni traccia di polvere ecc. che si sia accumulata. Sincerarsi che non esistano segni di usura o danno, ad es. usura dell'attuatore, usura del gruppo camme, ossidazione dei contatti, e sostituire in caso di usura o danno. Rimettere al loro posto i coperchi e serrare le viti con le coppie specificate. Riconnettere l'alimentazione elettrica e verificare il corretto funzionamento. Applicare nuovamente vernice tamper evident o un composto simile ai punti di fissaggio. Riparazione In caso di funzionamento anomalo o di danno, non si deve cercare di effettuare una riparazione. L'unità deve essere sostituita prima di ricominciare a far funzionare la macchina. NON SMONTARE L'UNITÀ. Informazioni su UL508 Per un utilizzo in temperature ambientali elevate, il cablaggio di campo dovrà essere dimensionato per limiti d'impiego a temperature non inferiori a quelle ambientali Specifica elettrica del codice delle prestazioni nominali: A600 Corrente massima: 120V c.a. - chiusura 60A, apertura 6A 240V c.a. - chiusura 30A, apertura 3A Max. VA: chiusura 7200, apertura 720 Utilizzare solo conduttori di rame. Utilizzare solo tubi protettivi polimerici. Utilizzare una entrata del condotto protettivo per le connessioni di campo. Dichiarazione di conformità Con la presente si dichiara che i prodotti illustrati su questo documento sono conformi ai Requisiti essenziali per la salute e la sicurezza (EHSR) della Direttiva europea sui macchinari (98/37/CE), ai requisiti pertinenti della Direttiva per la bassa tensione (73/23/CEE come modificata da 93/68/CEE). Questi prodotti sono anche conformi alle normative EN 60947-5-1, EN 1088, EN 292, EN 60204-1 e sono approvati per un uso da parte di terzi. Compruebe que la máquina esté parada y aislada siempre que la puerta de seguridad esté abierta. IMPORTANTE: Tras la instalación y la puesta en funcionamiento se deberá cubrir el accionador, el conmutador y los tonillos de sujeción de la tapa del conmutador con un barniz revelador de intentos de apertura o producto similar. Mantenimiento Cada semana Compruebe la que el accionador del conmutador esté alineado y que el circuito de conmutación funciona correctamente. Compruebe también que no haya signos de uso incorrecto o manipulación no autorizada. Compruebe que la carcasa y el accionador no presenten daños. Si los hubiera, sustitúyalos. Cada 6 meses, como mínimo Aísle toda entrada de corriente. Retire la tapa y la cubierta final. Compruebe el ajuste de todos los terminales. Limpie cualquier acumulación de polvo, etc. Compruebe si hubiera signos de desgaste o daños en el conjunto del accionador, óxido en los contactos, etc., y haga los cambios pertinentes. Vuelva a colocar las tapas y apriete los tornillos con los ajustes correspondientes. Vuelva a conectar la toma de corriente y compruebe que funciona correctamente. Vuelva a aplicar a las sujeciones un barniz revelador de intentos de apertura o compuesto similar. Reparación Si hubiera algún defecto o avería, no intente repararlos. Sustituya la unidad antes de autorizar el funcionamiento de la máquina. NO DESMONTE LA UNIDAD. Información referente a UL508 Si se utiliza en entornos elevados, la temperatura efectiva del cableado del inductor no deberá ser inferior a la temperatura ambiente. Especificaciones eléctricas de servicio: A600 Corriente, máx: 120V CA - apertura 60A, cierre 6A 240V CA - apertura 30A, cierre 3A V/A máx.: apertura 7200, cierre 720 Use solamente hilos conductores de cobre. Use solamente conductos poliméricos. Use una entrada de conducto para las conexiones inductoras. Declaración de conformidad Los productos que aparecen en este documento cumplen los requisitos esenciales de seguridad e higiene de la Directiva Europea de Maquinaria (98/37/EC) y los requisitos pertinentes de la Directiva de Bajo Voltaje (73/23/EEC, enmendada por 93/68/EEC). Asimismo, los productos cumplen la normativa EN 60947-5-1, EN 1088, EN 292, EN 60204-1 y cuentan con el sello Third Party Approval. 1 N.C. or 2 N.C. direct opening action Sicherheitskontakte (Elf) 1 N.C. oder 2 N.C. direkte Öffnung Safety Contacts (Cadet 3) 2 N.C. or 3 N.C. direct opening action Sicherheitskontakte (Cadet 3) 2 N.C. oder 3 N.C. direkte Öffnung Designation / Utilization Cat. A600 / AC-15 (Ue/Ie) 600V / 1.2 A, 500V / 1.4 A, 240V / 3 A, 120V / 6 A N600 / DC-13 (Ue/Ie) 600V / 0.4 A, 500V / 0.55 A, 240V / 1.1 A, 120V / 2.2 A Bezeichnung / Einsatzkat. A600 / AC-15 (Ue/Ie) 600V / 1.2 A, 500V / 1.4 A, 240V / 3 A, 120V / 6 A N600 / DC-13 (Ue/Ie) 600V / 0.4 A, 500V / 0.55 A, 240V / 1.1 A, 120V / 2.2 A Thermal Current 10 A Wärmestrom 10 A Current, Min. 5V 5 mA dc Strom, Min. 5V 5 mA dc Auxiliary Contacts Ingress Protection Rating 1 N.O. Hilfskontakte Eindringen-Schutzgrad 1 N.O. Operating Temperature IP67 (–20 °C…+80 °C), (–4 °F…+176 °F) Mechanical Life Electrical Life Torque Settings, Max. Deutsch English Safety Contacts (Elf) Betriebstemperatur IP67 (–20 °C…+80 °C), (–4 °F…+176 °F) 1,000,000 operations Mechanische Lebensdauer 1.000.000 Betätigungen 1,000,000 operations Elektrische Lebensdauer 1.000.000 Betätigungen 1.4 1.2 1.0 0.8 Drehmomenteinstellungen, Max 1.4 1.2 1.0 0.8 N•m N•m N•m N•m (12.39 lb•in) fixing bolts (10.62 lb•in) lid screws (8.85 lb•in) terminal screws (7.08 lb•in) head bolts Contacts de sécurité (Elf) 1 N.C. ou 2 N.C. ouverture directe Contactos de seguridad (Elf) 1 N.C. o 2 N.C. acción de apertura directa Contacts de sécurité (Cadet 3) 2 N.C. ou 3 N.C. ouverture directe Contactos de seguridad (Cadet 3) 2 N.C. o 3 N.C. acción de apertura directa Désignation/utilisation A600 / AC-15 (Ue/Ie) 600V / 1.2 A, 500V / 1.4 A, 240V / 3 A, 120V / 6 A N600 / DC-13 (Ue/Ie) 600V / 0.4 A, 500V / 0.55 A, 240V / 1.1 A, 120V / 2.2 A Cat. designación / utilización A600 / AC-15 (Ue/Ie) 600V / 1.2 A, 500V / 1.4 A, 240V / 3 A, 120V / 6 A N600 / CC-13 (Ue/Ie) 600V / 0.4 A, 500V / 0.55 A, 240V / 1.1 A, 120V / 2.2 A Intensité thermique 10 A Corriente térmica 10 A Intensité minimale 5V 5 mA cc Corriente, mín 5V 5 mA cc Contacts auxiliaires Protection 1 N.O. Contactos auxiliares Protección contra el ingreso 1 N.O. Plage de températures de service IP67 (–20 °C…+80 °C) Temperatura operativa IP67 (–20 °C…+80 °C), (–4 °F…+176 °F) Durée de vie mécanique Durée de vie électrique 1 million de cycles Vida mecánica 1.000.000 operaciones 1 million de cycles Vida eléctrica 1.000.000 operaciones Vis de fixation 1.4 N•m Vis du couvercle 1.2 N•m Vis des bornes 1.0 N•m Boulons à tête 0.8 Nm Couples de serrage Ajustes de par, máx. 1.4 1.2 1.0 0.8 Remarque : Les contacts de sécurité de ces produits sont décrits comme normalement fermés (NF), c'est-à-dire lorsque la protection est fermée, l'actionneur en place (si applicable) et la machine en état de démarrer. Italiano (12.39 lb•in) Befestigungsschrauben (10.62 lb•in) Deckelschrauben (8.85 lb•in) Klemmenschrauben (7.08 lb•in) Kopfbolzen Hinweis: Die Sicherheitskontakte dieser Produkte sind als normalerweise geschlossen (N.C.) beschrieben, d.h. bei geschlossener Schutzvorrichtung, Betätigungselement in Position (falls zutreffend) und Maschine startfähig. ESPAÑOL Français Note: The safety contacts of these products are described as normally closed (N.C.), ie. with the guard closed, actuator in place (where relevant) and the machine able to be started. N•m N•m N•m N•m Contatti di sicurezza (Elf) 1 N.C. o 2 N.C. ad azione diretta di apertura Contatti di sicurezza (Cadet 3) 2 N.C. o 3 N.C. ad azione diretta di apertura Designazione / Cat. di utilizzazione A600 / c.a.-15 (Ue/Ie) 600V / 1.2 A, 500V / 1.4 A, 240V / 3 A, 120V / 6 A N600 / c.c.-13 (Ue/Ie) 600V / 0.4 A, 500V / 0.55 A, 240V / 1.1 A, 120V / 2.2 A Corrente termica 10 A Corrente, min. 5V 5 mA c.c. Contatti ausiliari Classificazione IP 1 N.O. Temperatura d'esercizio IP67 –20 °C…+80 °C Durata meccanica 1.000.000 di funzionamenti Durata elettrica 1.000.000 di funzionamenti Regolazioni coppia, massima 1.4 1.2 1.0 0.8 N•m N•m N•m N•m per per per per i bulloni di fissaggio le viti del coperchio le viti dei morsetti i bulloni della testa NB: i contatti di sicurezza di questi prodotti sono descritti come normalmente chiusi (NC), vale a dire con la protezione chiusa, l'attuatore in funzione (ove sia richiesto) e la macchina in condizione di avviamento. N•m N•m N•m N•m (12.39 lb•in) tornillos de sujeción (10.62 lb•in) tornillos de la tapa (8.85 lb•in) tornillos terminales (7.08 lb•in) pernos de cabezales Nota: Los contactos de seguridad de estos productos se describen como normalmente cerrados (o N.C.), es decir, con el protector cerrado, el accionador en su lugar (si procede) y la máquina en condiciones de arrancar. Proprietary Equipment Page 96 of 101 Instruction Manual CSM722 SIFTER Order numberPTI003990-M22320, Doc-ID: APH 20-11-13 Proprietary Equipment 14.2 Motor instructions Instruction Manual CSM722 SIFTER Order number: PTI003990-M22320, Doc-ID: APH 20-11-13 Page 97 of 101 2218E Issue 1e Spare parts, installation and maintenance EEx e, EEx nA and combustible dust designs Typical W construction Frame sizes W-DA71 to W-DF355 26 25 24 17 9 4 3 11 10 8 12 14 13 15 16 22 1 19 23 21 7 5 6 5 20 2 2 Ref Part description Ref Part description Ref Part description 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 Drive end endshield fixing bolts Drive end endshield Drive end oilseal Preloaded washer Drive end bearing Rotor assembly Stator assembly with or without feet Earth terminal Eyebolt Non-drive end bearing cap (when fitted) Non-drive end bearing Bearing circlip Non-drive end oilseal Non-drive end endshield Non-drive end endshield fixing bolts Fan Fan circlip Fan cover Foot locking method (when fitted) Bolt-on feet and bolts Terminal board and fixing screws Terminal box, gasket and fixing screws Terminal box lid, gasket and bolts Flange endshield Face endshield Bolt-on pad 18 2218E Issue 1e Spare parts, installation and maintenance EEx e, EEx nA and combustible dust designs Marking Marking Typical marking is as shown below 1180 II 2G EEx e II T3 and has the following meaning: Compliant with European Directives Temperature class Maximum surface temperature T1 450°C T2 300°C T3 200°C Notified body (test house), T4 135°C identification number T5 100°C T6 85°C Equipment group EC Mark for electrical equipment in hazardous atmospheres Group Application I Mining Non-mining II E - European certification (1180 = Baseefa (2001) Ltd) Ex - Explosion protection II 2 G EEx e 1180 II T3 G = Gas OR D = Dust d - Flameproof to EN 50018 e - Increased safety to EN 50019 nA - Non-sparking EN 50021 de - Flameproof with increased safety terminals EN 50018 & 19 Dust - EN 50281-1-1 Equipment category Gas symbol G Zone Criteria Presence of Gas or Dust Dust symbol D Category 1 Zone 0 Category 1 Zone 20 Category 2 Zone 1 Category 2 Zone 21 Present in normal operation Category 3 Zone 2 Category 3 Zone 22 Unlikely but if present, then only for a short time Continuously or very long period Note: Category 1, Zone 0 and Zone 20 are not applicable to electric motors Dust are marked differently, eg: 1180 II 2 D T125°C T125°C = certified external surface temperature 3 2218E Issue 1e Spare parts, installation and maintenance EEx e, EEx nA and combustible dust designs General/installation Warning These motors are certified by a European Notified Body for use in hazardous areas and should be installed, maintained and repaired (if necessary), strictly in accordance with the relevant standards and codes of practice of the user country for the repair and overhaul of Ex electrical apparatus. (For example, in UK: EN 6007919 and recommendations outlined in the BEAMA/AEMT ‘Code of Practice’ for repair and overhaul of Ex electrical apparatus’). The certificates issued apply to motors as originally supplied, and in order to maintain validity, it is essential that any servicing/ repair be undertaken only by accredited establishments (see paragraph on ‘Spares and Repairs’). Only genuine replacement parts can be used on these certified motors - always specify motor serial number, output (kW), RPM, voltage, Hz and mounting when ordering spares. Warning Qualified personnel only must undertake handling and lifting of electric motors. See additional sections of this manual and the customer safety and installation instructions. Full product documentation and operating instructions must be available together with tools and equipment necessary for safe working practice. Note - before any work commences, reference should be made to the warning paragraph at the top of this page. Receipt Before any motor is accepted on site, it should be carefully inspected for damage or loss incurred during transit. Report any damage to the carriers and your supplier as soon as possible, quoting the motor and/or order number and consignment note reference. The insurance companies agents shown on the insurance certificate should also be advised. Storage If the motor is not to be used immediately, it should be stored in a clean, dry place which is vibration free. Temperature should be stabilised to -20°C to +40°C. When drain holes are provided, they are supplied with a screwed, fitted plug. Under no circumstances should the motor be located or operated in a hazardous environment with these plugs removed as the enclosure protection will be compromised. Lifting Eyebolts and/or lifting trunnions supplied with the motor are designed to support only the weight of the motor, not the weight of 4 the motor and any ancillary equipment attached to it. Be absolutely sure that cranes, jacks, slings and lifting beams are capable of carrying the weight of equipment to be lifted. Where an eyebolt is provided with the motor, this should be screwed down until its shoulder is firmly against the face of the stator frame to be lifted. Eyebolts are normally designed for a vertical lift. Where two eyebolts are used with inclined loading, the maximum safe working loads should not be exceeded, see table (approximate weights) on page 5. Bearings To avoid static indentation (false brinelling), the storage area should be vibration free. If this is not possible, it is strongly recomended that the motors be stood on thick blocks of rubber or other soft material. Where exposure to some vibration is not unavoidable, the shaft should be locked in position to avoid static indentation of the bearings Shafts should be rotated by hand (90°), weekly/periodically. Roller bearings may be fitted with a shaft locking device. This should be kept in place during storage. Grease Factory fitted regreasable bearings use either Lithium or Polyurea based grease with a recommended shelf life of two years. If stored for a longer period, the grease may need to be replaced. Shielded bearings have a storage life of five years and a further two years operational life following installation. Heaters Where anti-condensation heaters have been fitted, it is strongly recommended that they are energised during storage. In such cases, prominent warnings of live terminals (inside the terminal box) must be posted inside and outside the terminal box. Heaters must be isolated whilst the motor is energised, since the heaters, if energised, could cause the motor surface temperature to exceed the maximum for which it is certified. This would invalidate the certification and could result in ignition of the surrounding atmosphere. Heaters must be de-energised before opening any part of the motor enclosure. Where the certificate permits, the winding may be energised at a low voltage as an alternative to anti-condensation heaters (for maximum voltage see marking on motor). The mains supply must be disconnected during these periods. Where anti-condensation heaters are not fitted, the use of a desiccant is recommended. Installation Withdrawal from storage Before taking any motor from storage, ensure that anti-condensation heaters (if fitted), have been disconnected and isolated before moving the motor. Check that no foreign matter is present and remove all surface dust and dirt. Test the stator insulation resistance between phases and also to earth. If an insulation resistance of lower than ten Megohms at 20°C is measured, the windings must be dried out. Any such tests must not be carried out whilst there is risk of the presence of an explosive atmosphere. After measurement, the windings should be discharged immediately to avoid the risk of electric shock or electrostatic discharge. Location Motors must be installed with adequate access for routine maintenance. A minimum of 0.75m of working space around the motor is recommended. Adequate space around the motor, particularly at the fan inlet (50mm), is also necessary to facilitate airflow. Where several motors are installed in close proximity or other heat sources are present, care must be taken to ensure that there is no re-circulation of exhausted warm air. Foundations must be solid, rigid and level. On motors which are mounted vertically with the output shaft facing upwards, the driven equipment must prevent falling objects from entering the fan housing. Electrical connection The connection diagram is shown on the leaflet enclosed in the motor terminal box or the diagram inside the terminal box lid. The cables used should be capable of carrying the full load current of the motor (see motor nameplate), without overheating or undue voltage drop. Cable terminations All cable terminations should be tightly secured. There should be no nuts or lock washers fitted between the supply and the motor lugs. Permanently attached cables shall be suitably protected against mechanical damage and terminated within the terminal or junction facility suitable for the conditions of use. Wiring should be carried out or checked by a qualified electrician and equipment must be earthed in accordance with current regulations. 2218E Issue 1e Spare parts, installation and maintenance EEx e, EEx nA and combustible dust designs Installation When the motor is despatched with plastic plugs fitted into the cable entry holes, these plugs must be removed prior to commissioning and a suitably certified gland inserted. Cable entries are not to be left open, therefore if any holes are unused or made redundant, they must be plugged with a suitably certified and correctly inserted stopping plug (stopping plugs to be removed only with the aid of a tool). Alternatively, a replacement gland plate or terminal box must be obtained from Brook Crompton. All cable glands/conduit/plugs etc, must have at least the same IP rating and the hazardous area certification as the motor, thereby ensuring that the motor certification and protection are not compromised. greasing presents a far greater hazard to trouble-free service than under greasing but careful attention is a mandatory requirement. Bearings without relubrication facilities will eventually need replacing. When changing bearings, it is essential to replace shaft seals that are of the same size, type and material as originally fitted. Care should be taken to ensure that shaft seals are not damaged during fitting and that the lips are lubricated. For details of which seals are used, please contact Brook Crompton. Fitting pinions, pulleys and couplings These should be stored to suit the shaft diameter. Note - the operating temperatures at the conduit or cable entry may exceed 70°C and at the branching point of the conductors may exceed 80°C under rated conditions. Warning Tapping of fitments onto the motor shaft with a hammer or mallet, causes bearing damage. This results in an increase in bearing noise and a significant reduction in bearing life. If aluminium cables are used they must be terminated in such a way, as to ensure protection against corrosion due to dissimilar metals. Earth bonding of the motor, both on the motor frame and inside the terminal box, should always be carried out to eliminate the risk of electrostatic discharges from the motor. Re-lubrication Recommended re-lubrication intervals are available on request as these are load dependant. When replenishing, use a type that is compatible to the grease detailed on the motor nameplate. (See table below.) Bearings Ball and roller bearings are despatched from the works fully charged with grease. Shielded bearings have sufficient grease for an operating life of at least two years in normal ambient temperatures, providing there is little or no grease leakage. On motors with re-lubrication facilities, replenish with a compatible grease but take care to avoid overfilling the bearing housings. It should be noted that over Type BS W-DA71S W-DF80M W-DF90S W-DF90L W-DF100L W-DF112M W-DF132S W-DF132M W-DF160M W-DF160L W-DF180M W-DF180L W-UDF200LNX W-UDF225S W-UDF225M W-UDF250ME W-UDF280SE W-UDF280ME W-UDF315SE W-UDF315ME W-UDF315M W-UDF315L W-UDF355S W-UDF355M W-UDF355L W-DA71S W-DF80M W-DF90S W-DF90L W-DF100L W-DF112M W-DF132S W-DF132M W-DF160M W-DF160L W-DF180M W-DF180L W-DF200LNX W-DF225S W-DF225M W-DF250S W-DF250M W-DF280S W-DF280M W-DF315S W-DF315M W-DF315L W-DF355S W-DF355M W-DF355L The time intervals between inspections should be sufficiently regular (to be decided by the user but not exceeding three months for combustible dust environments), so as to ensure that the user can be alerted to excessive build up of accumulated layers of dust on the equipment surface. Routine cleaning should include but not be limited to the following: a) b) Ongoing mainenance a) b) c) d) e) f) g) h) i) Maintenance Warning Isolate power supply to motor before commencing any routine cleaning or maintenance work. Remove the fan cover and ensure that all air inlet holes are completely free. Clean any dust or dirt and obstructions from behind the fan and along the ribs of the frame. Tightening torques and bolt sizes can be obtained from Brook Crompton. When the ambient temperature is outside the normal operating range of the grease, see rating plate for re-lubrication details. j) As routine cleaning first. That no visible damage has occurred to the motor, ie cracked or broken components, bent fan cowl, loose components etc. Running clearances are adequate No significant corrosion of the lifting facilities No excessive vibration No loose bolts or fasteners Cables and earths are sound Sealing of the motor and gland plate are in good condition. This is to include the condition of the gaskets, shaft seal and jointing compound Insulation resistance is adequate. It is imperative that this is checked prior to starting and after prolonged shut down Regreasing or replacement of bearings if normal life has been exceeded Re-lubrication table Approximate weights European Routing cleaning Net weight kg Gross weight kg Cubage m3 6.5 15 19 22 35.5 45 68 72.5 121 133 162 177.5 255 320 375 420 570 660 800 1000 1100 1300 2000 2300 2500 6.9 16.5 20.5 23.5 38 48 71 78.5 133 145 178 193.5 270 335 390 460 610 721 871 1095 1195 1395 2120 2420 2620 0.01 0.02 0.03 0.03 0.03 0.05 0.08 0.08 0.15 0.15 0.21 0.21 0.30 0.37 0.37 0.63 0.70 1.2 1.2 1.8 1.8 1.8 2.3 2.3 2.3 Frame size 71/355 Grease Type Esso Unirex N3 Lithium complex NSK EA6 Polyurea Note: Lithium complex type greases are not compatible with Polyurea type greases - refer to nameplate Standard regreasing facility Frame size 71 80/180 200/355 Facility Sealed for life bearings On request Regrease facility as standard 5 2218E Issue 1e Spare parts, installation and maintenance EEx e, EEx nA and combustible dust designs Maintenance blind hole could ‘bottom’ and prevent correct closure of a joint. Recovery of tapped holes by counter drilling and fitment of propriety inserts is not recommended by Brook Crompton. Periodic maintenance a) b) c) d) e) f) As routine cleaning first. Remove the fan cover and the fan. Loosen and remove bearing cap screws and endshield screws/studs. The endshields should then be eased off their spigots and removed. The rotor can now be carefully withdrawn from the stator - taking care not to damage the stator bore, the stator winding and the rotor. Having dismantled the motor, maintenance can be carried out to remove all dirt. For this purpose, the use of an air line supplying dry compressed air under comparatively low pressure is best as a high velocity air stream can force dirt into the spaces between the windings and insulation etc. Grease removing solvents should only be used very sparingly to avoid damage to impregnation varnish or insulation. For lubrication details, refer to earlier ‘Installation’ paragraph. Motors should be reassembled in the reverse order from dismantling, remembering to ease endshields onto bearings and spigots. Do not use force. All shaft seals and enclosure gaskets should be replaced using identical components to those originally fitted. If required, the enclosure joint faces should be liberally coated with a suitable non-setting gasket and jointing compound to ensure the integrity of the enclosure. Motors certified for Zones 21 or 22 may require additional sealant applying to various faces before assembly. Please refer to item j. g) h) i) 6 Before starting, check that the rotor revolves freely. Ensure that the electrical connections are correct and terminal nuts tight (see section ‘Electrical Connection’). Refit any pulley, coupling, sprocket etc which has been removed - being particularly careful to ensure correct alignment with the driven part, as misalignment will lead to ultimate bearing trouble and shaft breakage. When replacing screws and bolts, care should be taken to use only those with the requisite quality and tensile strength recommended by the manufacturer. A minimum grade of 8.8 is required for all fixing screws except socket head cap screws which must be a minimum of grade 12.9. These must also be of identical thread form and screw/bolt length. A marginally longer bolt, screwed into a j) The following lists the joint faces to be coated with gasket and jointing compound for motors used in Zones 21 or 22: a) Motors with IP55 enclosure for use in Zone 22 environments where dust is non-conductive. b) Motors with IP65 enclosure for use in Zone 21 and 22 (with conductive dusts): 1) Stator frame to endshield spigot face - drive end and non-drive end, and where appropriate: 2) Stator frame to terminal box and/or conduit facing. 3) Terminal box body to terminal box lid 4) Terminal box to spreader box/gland plate 5) Spreader box to gland plate 6) Removable drain plugs Further, soft copper washers should be replaced to inner bearing cap and gland plate fixing screws. The practices given in IEC 60079-14 should be followed for inspection of components and the treatment of corrosion during maintenance. Spares and repairs When ordering spares, it is important to state the motor serial number to ensure that the correct spares will be supplied. Notes: a) Fixing bolts, nuts, studs, screws, spacers or washers are not included with these parts and, if required, should be clearly specified on the order in addition to the part description number. The fixing duty and part description reference number for which they are required should also be clearly stated. b) Bearings ordered direct from bearing manufacturers must be specified as follows: ‘ISO CN, ISO C3’, with bearing size. (Bearing fit to be as original motor drawing). Responsibility for the validity of certification after repair work or the fitting or spares rests with the user. Such repairs should be carried out by competent engineers who are fully trained in working on equipment for hazardous areas. Spares for our certified motor ranges are quoted/supplied on the understanding that the subsequent validity or certification of any repair* work and/or fitting of spares and replacement parts, rests with the user or accredited repair establishment. This is one where: 1) Either: a) Personnel have attended a course appropriate to the codes of practice and standards of the nation where the motor is installed. This will normally be a course recognised by the national trade association, health and safety inspectorate or certifying authority (eg, in the UK the AEMT course ‘Repair and Overhaul of Ex Electrical Apparatus’). or b) Personnel have attended Brook Crompton’s ‘Hazardous Atmosphere Motor Repair Course’. 2) The workshop is approved by Brook Crompton’s authorised repair agent liaison officer or is otherwise suitably accredited by a nationally recognised competent authority. 3) Brook Crompton’s hazardous atmosphere repair manual is held and strictly adhered to. Where the motor has been originally repaired as indicated by symbol ‘R’ in accordance with IEC 60079-19, details of the repair should be obtained from the user/repairer before proceeding with repair. Alternatively, contact Brook Crompton. Training videos Brook Crompton has produced a set of videos covering the theory, design, construction and repair of electric motors for use in hazardous areas. These are available from Brook Crompton marketing department. Motor modifications Details on how to modify motors along with bolt sizes and tightening torques can be obtained from Brook Crompton. Responsibility for the validity of certification after any modifications rests with the user. Such modifications should be carried out by competent engineers who are fully trained in working on equipment for hazardous areas. 2218E Issue 1e Spare parts, installation and maintenance EEx e, EEx nA and combustible dust designs Inspection schedule Table 1 – Inspection schedule for safe use Initial Check that Inspection category* Periodic Apparatus is appropriate to area classification A A Surface temperature is correct A A Apparatus subgroup (if any) is correct A A 1 Apparatus carries the correct circuit identification A B Enclosures are satisfactory and undamaged, drain holes are closed A A There are no unauthorised modifications A A Bolts, glands and stopping plugs are complete and tight A A Obstructions do not conflict with IEC 60079-14 A A Enclosure seals are satisfactory A A Gaps are free from corrosion, dirt and paint A A 2 There is no undue accumulation of dust or dirt B B All conduit runs and fitting are tight and free from corrosion A B Earthing is satisfactory A A Condition of enclosure gaskets are satisfactory A B Electrical connections (used and unused) are tight A B Motor airgaps and other running clearances are satisfactory A A Electrical protection is satisfactory, overcurrent protection etc A A A A Apparatus is adequately protected against corrosion, the weather, vibration and other adverse factors A A Guards (where used) are present and correctly fitted A A Fan cowl undamaged and fitted correctly A A Only 1 single or multistrand lead may be connected to either side of of any auxiliary terminal, unless A A A A Ensure that only one lead is connected to either side of the auxiliary terminal block A A Circuits carry greater than 1 amp shall be individually and suitably overcurrent protected A Connecting leads must be insulated for the appropriate voltage and the insulation must extend to within A A A B 3 There is no obvious damage to cables, cable sheaths or cable glands multiple connectors have been joined in a single insulated crimped boot lace ferrule Leads to auxiliary blocks are to be a minimum of 1.0mm2 when connected to heaters, thermistors or thermostats 1mm of the metal terminal The suitability of the plastic fan material for certain solvents should be ascertained by the user Notes: 1 Apparatus must be positively identified with its circuit to ensure that correct isolation can be carried out. 2 Accumulation of dust or dirt can interfere with heat dissipation and result in surface temperature higher than those permitted in the hazardous area. 3 Particular attention should be paid to flexible cables used with portable apparatus. *Category A inspections should be carried out in all cases. Category A intervals must not exceed 2 years. More frequent and/or more detailed inspection will be necessary where there is a corrosive or other adverse atmosphere, a high risk of mechanical damage or vibration, or where there are other onerous circumstances. The need for more frequent inspection may also be determined by operating experience. The need for, the method, and the frequency of category B inspections is at the discretion of the engineer responsible. It is not intended that periodic inspections should incur undue disturbance of apparatus unless considered necessary by the engineer responsible. 7 Rotating Electrical Machines Worldwide sales and service network Proprietary Equipment Page 98 of 101 Instruction Manual CSM722 SIFTER Order numberPTI003990-M22320, Doc-ID: APH 20-11-13 Gericke contact addresses 14.3 15 Gericke contact addresses In the unlikely event of experiencing problems Gericke or Gericke accredited representatives may be contacted at the following addresses for assistance: Gericke AG, Althardstrasse 120, CH-8105. Regensdorf Switzerland Gericke BV, Postbus 46, Zuiderinslag 18, NL-3870 Ca Hoevelaken Holland Tel: + 01 8 71 36 36 Fax: + 01 8 71 36 00 [email protected] Tel: + 3325 36 88 8 Fax: + 3325 34 41 0 [email protected] Gericke GmbH, Gericke PTE Limited Max-Eyth-Strasse 1, D-78239 Rielasingen. Germany 436 Tagore Avenue Singapore 2678 Tel: + 0 77 31 929-0 Fax: + 0 77 31 929-310 [email protected] Tel: +01654 52 81 33 Fax: +01654 52 [email protected] Gericke SA, 7 Rue Guy Moquet, F-95100 Argenteuil. France Tel: + 01 39 98 29 29 Fax: + 01 39 82 29 74 [email protected] Gericke Ltd., Victoria House, Cavendish Street, Ashton-under-Lyne, OL6 7DJ, United Kingdom Tel: + 0161 344 1140 Fax: + 0161 308 3403 [email protected] Instruction Manual CSM722 SIFTER Order number: PTI003990-M22320, Doc-ID: APH 20-11-13 Page 99 of 101 Gericke contact addresses Representatives: Lenz Atzl, Ing. F.R. Atzl, Josef-Erl-Gasse 7, A-2540 Bad Voeslau, Austria Tecnosa Nuevas Tecnologies SA, c/Roses 99-101, ES-08980 Sant Fellu de Llobregat. Tel : + 34 (0) 934 734 676 Fax : + 34 (0) 934 732 567 Tel: + 0043 2252 76015 Fax: + 0043 2252 76015 Oriling, AB Oscar Lindberg, Ingenjörsbyra, Duvnäsgatan 12, S-11634 Stockholm. Powder Technologies Inc, P.O Box 2277, Willingboro, NJ 08046, U.S.A. Tel: + 0016 0991 40521 Fax: + 0016 0991 40318 Tel: + 08/64 13 53 0 Fax: + 08/64 14 61 0 Gericke I/S, Skandsrups Allé 20, DK-3500 Vaerløse. Tel: + 0 45 44 44 12 55 Fax: + 0 45 44 44 80 06 Caspar Hansen & Co., A/S, Ing. Firma, Ramstadsletta 8, N-1322 Hövik. Tel: + 0 67 12 10 20 Fax: + 0 67 59 16 18 Oriling OY, Ytheistyönkatu 13, SF-53300 Lappeenranta Tel: + 0 53/4 57 02 31 Fax: + 0 53/4 57 02 20 Page 100 of 101 Instruction Manual CSM722 SIFTER Order numberPTI003990-M22320, Doc-ID: APH 20-11-13 Gericke contact addresses 1 Appendix Pos : 152.2 /13 Anhang/C hec kliste vor Pr obelauf --nur Titel-- @ 0\mod_1275494138234_968.doc @ 1317 @ 21222222233333321 @ 1 1.1 Checklist for test run Pos : 152.3 /13 Anhang/Misc her/Chec kliste vor Probel auf (HIN WEIS) @ 0\mod_1275494220015_968.doc @ 1318 @ 212 @ 1 NOTE! Copy the checklist and tick off items on the copy. checked by check completed Technician there are no foreign bodies in the device. Technician the minimum clearance between the paddles blades and basket is correct. Electrical technician power supply feeds are connected and fused in compliance with local regulations. Technician there is a directional arrow on the drive. Technician the direction of rotation of the shaft assembly is according to the arrow on the drive. Electrical technician the device is earthed in accordance with regulations. Technician Connection lines are tight. Pos : 152.4 /13 Anhang/Z ugehörige Dokumente --nur Titel-- @ 0\mod_1275494265828_968.doc @ 1319 @ 221213 @ 1 1.2 Associated documents Pos : 153 /13 Anhang/Z ugehörige Dokumente P+I Diagramm @ 4\mod_1326376219875_968.doc @ 24897 @ 33333312 @ 1 Pos : 154 /13 Anhang/Z ugehörige Dokumente Installati ons Z eichnungen @ 4\mod_1320539670660_968.doc @ 23260 @ 2333333121222222 @ 1 GA drawing OEM Documentation Confirmation of Manufacturer Declaration of Incorporation Pos : 155 /13 Anhang/Z ugehörige Dokumente El ektr o Appar ateliste @ 4\mod_1320539673035_968.doc @ 23274 @ 21222222 @ 1 Pos : 156 /13 Anhang/Z ugehörige Dokumente Dokumentation OEM @ 4\mod_1320539671957_968.doc @ 23267 @ 212 @ 1 Pos : 157 /13 Anhang/Z ugehörige Dokumente Hersteller beschei nigung @ 4\mod_1328535499630_968.doc @ 25490 @ 1212 @ 1 Pos : 158 /13 Anhang/Z ugehörige Dokumente Konfor mitäts er klär ung @ 4\mod_1320540344953_968.doc @ 23295 @ 21222222 @ 1 === Ende der Liste für T extmar ke Inhalt === Pos: 54.3 /05 Aufbau und Funktion/Mischer/GMS/Übersicht GMS 2800 ECD @ mit222 Einlaufdeckel Coraklappe und Energiekette @ 4\mod_1332768596825_968.doc @ 26125 @1 Pos: 78.3 /05 Aufbau und Funktion/Mischer/GMS/Ablaufdiagramm 5\mod_1348825606004_968.doc @ 28877 @ 2123333333322222 GMS @ 1 Neu @ Instruction Manual CSM722 SIFTER Order number: PTI003990-M22320, Doc-ID: APH 20-11-13 Page 101 of 101
© Copyright 2024