Document 328384

SUPERLON'
Quality NBR Insulation
SUPERLOTV
Quality NBR lnsulation
Superlon products are produced with top qualities ond meet various
industry standards to ensure insulation performance.
Classl&Class0
High fire performance
Low thermal conductivity
High moisture resistance
Superlon Class
l
40kc/mr-7oks/ml
Density Rang€
Maximum 10s 0c pipes / (85
Minumum -500c
and Class 0 is an elastomeric
nitrile foamed insulation engineered and
designed specifically to control condensation.
0C
for flai surfaces)
FIRE RESISTANCE
surfarespread of Flames
476 Part 7
85 476 Part 6
BS
Class 1
(r) <
sub lndex (n)
<
12
Its main uses are for an insulating pipework
particularly for air conditioning ducting, chilled
Tora rndex
water lines and refrigerated pipes.
V-0,5VA/HF-1, Self Exnnsuishinc, Does not Drip
Superlon insulation materials are certified for
both class l and Class o.British standard (BS)
476 part 6 and part 7 is a widely accepted test
standard. Part 6 {fire propagation) measures the
heat that is released under fire conditions. Part 7
(spread of flame) measures the material's ability
to retard flame spread under fire conditions.
Clqss 7 is q widely occepted standard.
5
Class 0
w/m.K
Ihermal conduchvity
,o'c
o"c
I
0.034
0.24
Water Vapour Permeability
+o
0.035
0.038
0.25
o)7
u > Tooo
AS]M C209
water Absorption bv Volume
CFC Fr€e,
Zero ODP, zero cWP
lf higher fire performonce is required, Closs 0 is the preferred choice for insulation.
Prevent Flame Spread
Low Smoke
No Dripping
superlon's Factory Mutual (FM) Approved
insuladon material is tested to the highest and
most stringent standards and can help to
prevent fire propagation at the most critical
times. Some FM Approved insulation materials
in the market prevent fire propagation; however,
drips whilst being burned and may cause other
to ignite and start burning
as
well. Superlon FM Approved insulation material
is
not only non-flammable; it does not drip, does
not contribute to fire spread and it
extinguishes once fire stops.
ASTM C518
ASTM E96
< 2.9 x 10rag/Pa.m.s
FM Approved
objects nearby
UL94
oc
self-
Maximum 10soC pipes
/
(85oC for
flat
i 1rrr,iri:l
:laf .rr I'.if.ii
-1h.r1,,:r,. II I rlr':r iilr.,rr:!
Thermal Conductivity
W/m.K (Btu.inlhr.fti
t)
Water Vapour Permeability
<
u
water Absorption by volume
!g/Pa.m.s
2.9 x 10
7000
>
<o 2v"
lt
lt
Accessories
re
High Density (HD)
t
Harder
-
r=ll,.r:tllt::,'
Aluminium
Stronger
Ru
bber
Colou r Product
HD Superlon material is a higher density alternatjve for
the regular line of Superlon insulation materials. lt is
harder, stronger and tougher with a higher tensile
strength than other equivalent materials in the market.
with a shore C
hardness of greater than 10 and density greater than
T0kg/m1 Furthermore, like all other Superlon products,
every piece of Superlon HD material is engineered,
produced and controlled with stringent procedures to
HD Superlon material is highly durable
ensure
q ua
lity and effectiveness.
Ad hesive Ru bber
lnsulation Glue
Size
Packing
1 Litre
15 Cans/ Ctn
3.36 Litre
6 cans/
ctn
@
s_y:"F.xLoil
About Superlon
lncorporated in l\4alaysia in 1992, Superlon Worldwide
has accumulated more than 20 years of manufacturing
experience in nitrile butadiene rubber (NBR) foam, lts
utmost priority is to assure consistent excellence of their
insulation materials and provide a service that is second
to
none. Superlon Worldwide pride themselves
Paint
Size.
Packing
in
presenting customers with quality products together
with prompt and reliable services.
Foam/ Gasket
Tape Size
3mm
5 Litres
2
Foam Tape
r48 mm x30ft
Ta
pe
Packing
24 Pcs/ Ctn
ca.s/ ctn
Gasket Tape
smmxlsmmx10lvl
72Pcs/ Ctn
Sizes
lnsulation Pipe (pieces per carton box)
lnsulation Rolls
Size
hsulation Wall Thickness
a/2"
3/8"
314"
7
!/4"
! 1/2"
6
10
13
79
2S
1/A"
3
4'x 30'
1.22\ 9.14
714"
6
250
156
110
49
30
1/4"
6
4'x30'
1.22x 9.14
3/8"
10
200
124
90
42
30
3/a"
10
4 x 30'
1.22x 9.14
712"
13
150
100
72
36
24
518"
16
120
90
63
36
20
t2
t2
3/4"
19
100
7Z
56
30
20
tz
7ls'
v'
22
90
64
48
25
18
9
9
25
80
56
42
20
16
9
9
1!8',
2a
72
49
36
20
16
9
a!4"
32
56
42
30
20
15
9
9
13/8',
35
48
36
30
16
12
9
9
\!12"
38
41
34
25
16
12
9
8
s/8"
42
30
25
16
L2
9
8
2a
20
15
10
8
5
51
24
10
12
9
8
6
2 7la',
54
21
20
t2
9
I
6
2 L/4"
57
21
10
9
6
6
231g',
60
20
18
t2
!2
9
6
6
1/8"
3
4'x3'
1.22 x4.914
2112"
64
18
15
8
6
6
1/4'
6
4'x
1.22 x Q.914
40
6
3
3/A"
10
\4.914
26
3
1/2"
13
4 x3'
1.22 r,0.914
2A
3
5/4"
16
4'x3'
1.22 x0.914
i-e:*S
3/4',
19
4'x3'
1.22 x4.914
14
25
4'x3'
1.22
x0.914
10
6
11/4',
32
4x3
1
.22 x0.914
8
38
4'x3'
1
.22 x0.914
L
77/8"
251a"
67
27/a"
3 7/A"
3 7/2"
15
18
18
13
9
8
76
18
12
8
8
80
16
72
8
6
89
t2
16
102
14
6
8
73
8
6
1,2
50
32
9
6
1/2"
t3
4'x 30'
1.27x9.14
9
6
5/8"
4'x 30'
1.22x 9.14
5
3/4"
t6
t9
4'x 30'
1
25
4'x 30'
1.22\ 9.14
4
6
11/4"
32
3.29'x 30
I
6
11/2"
38
3-29 x30'
1x9.14
50
3.29'x 6.75'
Size
3
4118"
105
74
72
6
5
1 1/2"
t/4"
108
L4
72
6
5
2"
4 7/2"
774
74
72
6
4
117
10
9
6
5 Ug',
130
10
9
6
3
sL14"
133
10
9
6
3
s 1/2',
14n
10
8
6
3
Superlon Tips:
15'C
5'C
-18'C
(13 mm)
(2srnm)
(38mm)
(2smm)
{38mm)
{s0mm)
(13mm)
(2smm)
Normal Conditions
Based on the weather condltions experienced
Using correct thickness
Maxl;um se;veriw of 29oc . nd
lnstalling the insulation material correctly
Severe Conditions
RH
1.1"
of 78%
7%"
confined and poorly ventilated areaswith
Maximum severity of 3soc and RH of 85%
Mild Conditions
Well vennlated, low humidity conditions
Maximum severity of 26oC and RH of 70%
Ambient temperature
Relative humidity
Pipe Size (outer diameter
Line temperature
Medium (gas or liquid)
1.22
Piping Line Surface Temperature
Before you install - Determine the thickness of the
insulation material based on five factors:
1.
2.
3.
4.
5.
3
For example:
correct installation will improve the lifespan and
performance of the insulation. Key factors of
good insulation:
.
.
3/8"
(10mm)
of pipe)
Fot morc tios. instdllino methods dnd to detetmine cofiect thickness. blease
contod vour Superlon advisof.
SUPERLON'
ffiffi
x 9.14
lnsulation Sheets
4
6
.22 x 9.14
Manufa€tu red by
Superlon Worldwide sdn. Bhd.
Lot 2736, Jalan Raja Nong, 41200 Klang, Selangor Darul Ehsan, Malaysia
Tel. No. : +603 5161
7778
|
Fax No. :
+603-51621778
|
Website
:
www.superlon.com.my