Generation 4 CommandCenter™ Generation 4 OS 8.0.2350-38 Release Notes Important Notes: Software activations are non-transferrable in the event of lost, stolen, or destroyed equipment. It is recommended to insure a Generation 4 CommandCenter™ at full value, including software activations. Software Compatibility Notes: The Generation 4 CommandCenter™ is compatible with the GreenStar™ 2 1800 Display, GreenStar 2 2600 Display, and GreenStar 3 2630 Display. It is also compatible with the Original GreenStar Display without the mobile processor. Equipment information and values will not be shared between the Generation 4 CommandCenter and the GreenStar display. Set-up information should be entered on both displays. To ensure complete and proper functionality, the most current version of GreenStar™ Display software, and Apex™, or another preferred partner desktop software should be used. The Generation 4 CommandCenter displays ISOBUS compatible implement screens. It will not control rates or sections of implements. Customer Contact Center Information: Web: www.StellarSupport.com E-mail: [email protected] North America: SUPPORT: 1-888-GRN-STAR (1-888-476-7827) ACTIVATIONS: 1-888-95DEERE (1-888-953-3373) Australia: 0011-800-833-3373 New Zealand: 00-800-0000-3333 Brazil: 0-800-891-4031 Mexico: 866-582-4068 Argentina: 0800-444-9126 South Africa: 0800-983-821 Zimbabwe: (Access code: 110-98990) 888-983-3373 Zambia: (Access code: 00-899) 888-923-3373 **Countries w/ Access codes – Dial access code first and once prompted, enter the toll free number. Release Notice These are the software update release notes for the Generation 4 CommandCenter™. Release notes can be found on https://my.deere.com/software-downloads/software-manager. Note: Your use of the software is governed by the End User License Agreement included in the software. Copyright © 1996-2014 Deere & Company 1 Generation 4 CommandCenter™ Release Notes Generation 4 OS 8.0.2350-38 Start Up of the Generation 4 CommandCenter™ The Generation 4 CommandCenter turns on and off with the tractor key switch. The start-up time of the Gen 4 CommandCenter may vary depending on a few variables. Warm Boot occurs when the CommandCenter display has run within the last 24 hours. The CommandCenter rests in a hibernation state for that time. CommandCenter powers up quickly. (approximately 15 seconds) Cold Boot occurs when the CommandCenter display has not operated for 24 hours or more, or if unswitched power has been disconnected. During this period, the CommandCenter shuts down completely to conserve battery power. Power up cycle after a cold boot will take approximately 60 seconds. Avoid turning key switch back on until screen has gone black after turning off the engine. Navigating the Generation 4 CommandCenter™: The menu button navigates to the applications on the CommandCenter. The applications found will include Tractor Settings, Applications, and System. Each of these will contain a unique set off features. Tractor Settings- Contains machine settings and adjustments. Applications- Contains (but is not limited to) applications for setup, machine/work data, precision ag applications, and Layout Manager. System- Contains options to manage display settings, view software, export/import, and diagnostics. The CommandCenter also has a shortcut bar located on the bottom of the screen that will open or perform applications. The ISOBUS VT when applicable. Work Recording button will include StarFire™ and implement information is also accessible form the shortcut bar, this will color the map but not record any information that can be exported. The CommandCenter has two default Run Pages from the factory. Run Pages are customizable screens on the CommandCenter. Users can cycle through run pages by pressing the green arrows in the upper right hand portion of the screen, swipping the screen left or right, or through the Nav bar below the display. Users can setup and edit Run Pages with Layout Manager. For more information about the CommandCenter look for the buttons on the top of a page or use the Help Center Application. 2 Generation 4 CommandCenter™ Release Notes Generation 4 OS 8.0.2350-38 Onscreen Help Overview The Generation 4 CommandCenter has onscreen help similar to the information found in the Operators Manual. Pressing the button on top of any page will show the help topic for that page. Additional information related to that topic can be found by pressing under the Table of Contents, this lists all other available pages related to this topic. The Help Center can be accessed through the shortcut bar by pressing the Help Center through the Menu, or pressing the button, accessing the on any Help page. AutoTrac™ AutoTrac can be found on a default Run Page, by accessing the AutoTrac application from the shortcut bar , or by navigating to it from the Menu. Guidance settings are accessed by navigating the Guidance Application and pressing List by pressing the Set Track button . A New Track or Track Set can be created in the Track located on the run page or in the guidance application. Available tracking modes include: Straight Track AB Curve Adaptive Curve A Track Set is group of existing lines that can be arranged and switched between quickly from a run page. Track Sets are created in the Track List and can be swapped between using or on the run page. Loading or creating a large track list with 500+ tracks may cause the CommandCenter to respond slowly while loading the Tracks. 3 Generation 4 CommandCenter™ Release Notes Generation 4 OS 8.0.2350-38 File Manager File Manager is the application on the CommandCenter that allows for data to be exported and imported. It is accessed by either navigating to the System Tab or an overlay that appears when a USB is inserted. Items that can currently be exported include: Guidance Lines Screenshots Error Log Files The Guidance Lines created in the Gen 4 CommandCenter are saved and exported in the GS3 2630 Display format. They will be saved under the GS3_2630 folder in a JD4600 or JD4100 Profile. This allows users to easily import and export guidance lines between the GS3 2630 and the Gen 4 CommandCenter. If guidance lines from two Generation 4 CommandCenters are exported to the same USB, some guidance lines may be overwritten. It is recommended that the data is backed up to desktop software application prior to exporting from the second machine. Items that can currently be imported include: Guidance Lines The Gen 4 CommandCenter will not ask for a profile when importing. It will merge all Guidance lines under the GS3_2630 format with the current guidance lines on the CommandCenter. Layout Manager Layout manager under the applications tab is used to customize a run page. Custom run pages allow for various functions to be organized on the screen. To create a new run Page the following steps are taken: 1. 2. 3. 4. 5. 6. 7. Navigate to Layout Manager Press the All Run Pages tab Press Add New Name the Run Page Press Add Module Select the desired Module Select Save To view this run page on the screen it must be added to the Active Set. To do this: 1. 2. 3. 4. 5. Press the Active Set tab in Layout Manager Press Active Run Pages Press Add Run Page Select the Run Page you want to add and press OK Select Save to add it to the Active Set This information can also be found on the CommandCenter by locating the Layout Manager. button on the pages in 4 Generation 4 CommandCenter™ Release Notes Generation 4 OS 8.0.2350-38 Software Version Listed below are the installed Packages for the Generation 4 CommandCenter. Any updates to Tractor Applications will be handled by a John Deere dealer. Package Version Generation 4 OS 8.0.2350-38 Generation 4 OS Help 8.2.61-1 AMS Applications 8.0.2350-38 Tractor Applications 1.15.285-13 Tractor Application Help 8.2.59-1 5
© Copyright 2024