Automation / Mini Type SCA41 Electrical Specifications Code: Resolution: Supply Voltage: Output Voltage: Output Current: Frequency Response: Output Format: Phase Sense: 1 to 7500 ppr (pulses per revolution) 4,5 Vdc min. to 30 Vdc max. (35 mA max. - no load) Low: 500 mV max. at 10 mA High: (Vin – 0,6) at -10 mA (Vin – 1,3) at -25 mA 25 mA max. load per output channel Shaft: Resolution up to 7500 ppr IP 64 (IP 50 for IDC connector option) Ø6 200 kHz max. Material: ** Weight: Ø 41 mm mm or Ø 1/4 inch Housing: Aluminum Cap: Electroplated Steel Aluminum (flat cable option) Shaft: Stainless Steel Encoder: ~ 50 gr (1,76 oz) Cable: 50 gr / meter (1,76 oz / meter) Bearing Life: > 1,9 x 1010 revolutions at rated load Shaft Speed: 12.000 rpm (max.) Starting Torque: < 0,005 Nm (0,708 oz-in) at 25° C Mass Moment of Inertia: 1,0 gcm² (1,42 x 10-5 oz-in-sec²) Shaft Loads: Axial: 20 N (4,50 lbs) max. Radial: 20 N (4,50 lbs) max. ** ** Two channel (A, B) quadrature with Index (Z) and optional complementary (A-, B-, Z-) outputs A leads B clockwise (CW) from the mounting end of the encoder Accuracy: +/- 0,8 arc-min. Noise Immunity: Incremental Gated with Channels A and B high Electrical Protection: Shaft Encoder - Mechanical Specifications Index: Outputs: ASIC Push pull and Differential OL7272 Push-pull and Differential Line Driver 26C31 Differential Line Driver 5V output (with 5V input) Reverse polarity and output short circuit protected Tested to EN61000-6-2 : 2005 (industrial environments) Electromagnetic compatibility (EMC) and EN 61000-6-3 : 2007 (residential, commercial, and lightindustrial environments) for Electromagnetic compatibility (EMC) Environmental Specifications Operating Temp.: -40° to +85° C Storage Temp.: -40° to +85° C Shock: 100 G / 11 ms Vibration: 10-2000 Hz / 10 G Bump: 10 G / 16 ms (1000 x 3 axis) Humidity: 98 % RH without condensation Enclosure Rating: IP 64 / Nema 4 (approx.) IP 50 / Nema 5 (approx.) - flat cable Connection Options Cable: 8 leads (0,05 mm2, 30 AWG) - Differential 5 leads (0,14 mm2, 26 AWG) - Standard twisted pairs; shielded Flat Cable: 10 lead flat cable with IDC connector ** = It is recommended, not to combine max. Value for all 3 parameters Rev. 1.5 05. June-2013 Scancon Tranevang 1 3450 Allerød Denmark Tlf +45 48 17 27 02 Fax +45 48 17 22 84 www.scancon.dk p. 1 Type SCA41 Output waveform Disk Resolutions (pulses per revolution) 1 4 10 11 12 15 20 25 30 Channel tolerance Phase difference tolerance Z channel tolerance 180 e° +/- 36 e° 90 e° +/- 18 e° 90 e° +/- 18 e° 36 50 60 64 75 90 100 125 128 150 180 200 250 256 300 360 400 500 512 600 1000 1024 1250 1800 2000 2500 2048 2500 3000 3600 5000 7500* Other options on request Pulses per revolution, min. 1 – max. 7.500 * Operating temperature: -20° C to 50° C Mechanical Dimensions Rev. 1.5 05. June-2013 Scancon Tranevang 1 3450 Allerød Denmark Tlf +45 48 17 27 02 Fax +45 48 17 22 84 www.scancon.dk p. 2 Type SCA41 Rev. 1.5 05. June-2013 Scancon Tranevang 1 3450 Allerød Denmark Tlf +45 48 17 27 02 Fax +45 48 17 22 84 www.scancon.dk p. 3 Type SCA41 Output Terminations Flat Cable w/ IDC Connector Standard Cable Standard Output Channel A AB BZ ZVsup GND Differential Output Differential Output * Wire Color Green NC Yellow NC Gray NC Brown White Pink Gray Green Yellow White Brown Red Blue GND = Circuit Ground Position Channel 1 2 3 4 5 6 7 8 9 10 NC Vsup GND NC A AB BZZ * Hewlett Packard (HP) compatible M9 5 - pin Position 1 2 3 4 5 6 7 8 Rev. 1.5 05. June-2013 mm (inches) mm (inches) mm (inches) IP 50 rating CE mark not available 0,5 m, 1 m, or 2 m cable length only M9 8 - pin Standard Output Differential Output Channel VDD GND A B Z Channel VDD GND A AB BZ Z- Scancon Tranevang 1 3450 Allerød Denmark Tlf +45 48 17 27 02 Fax +45 48 17 22 84 www.scancon.dk p. 4 Type SCA41 Ordering Code ** Designed specifically for Wind Power applications. See SCA24 COC under Industries – Wind Power – SCA24 for additional conformity standards testing. Example: SCA41 – 1024 – D – 06 – 12 – 64 – 01 – B TSM = Transient Suppression Module Type Available only as Standard output SCA41 - Pulses per Revolution Output Shaft Dia. Shaft Length IP Rating - - Cable Length Cable Takeout Connector See table IP 64 IP 50 Standard Standard – Open Collector NPN Standard – Open Collector PNP Differential 26C31 Line Driver 5V only OL 7272 Line Driver Standard - with built-in TSM ** N NON PNP D L M T 64 50 Standard Cable Standard is 1 meter Specify length 01 XX Flat Cable w/ IDC 0,5 meter 1,0 meter 2,0 meters 0,5 01 02 *=Only IP 50 No connector M9 5-pin M9 8-pin IDC* 00 P5 P8 IDC * = Only Flat Cable 6.0 mm 6.0 mm 6.0 mm 1/4 inch x x x x 10 mm 12,5 mm 14 mm 12,5 mm 06 06 06 1/4 - 10 12 14 12 Side (radial) Back (axial) Flat cable w/ IDC connector S B SF ** = Designed specifically for Wind Power applications. See SCA24 COC under Industries – Wind Power – SCA24 for additional conformity standards testing. Other options on request: Please contact Scancon A/S TSM = Transient Suppression Module Available only as Standard output Rev. 1.5 05. June-2013 See Accessories for drawings Scancon Tranevang 1 3450 Allerød Denmark Tlf +45 48 17 27 02 Fax +45 48 17 22 84 www.scancon.dk p. 5
© Copyright 2024