The EDM Series of axial extractor fans

AXIAL EXTRACTORS
EDM Series
EDM 80-EDM 80L
Description
The EDM Series of axial extractor fans
consists of four nominal product sizes, the
EDM-80 -100,-160 and -200 models. The
EDM series have been designed for domestic
ventilation applications and are easy to install,
offer quiet operation, aesthetically pleasing
and are available with a variety of operational
specifications. Air flow performances range
from 80 up to 200 m3/hr.
The EDM Series are ideally suited for wall or
ceiling mounted installations and for short
duct run extract applications. To compliment
the fans a wide range of ancillary accessories
are available.
EDM 100
EDM 200
Range
The EDM Series consists of four different
models: – EDM-80
– EDM-100
– EDM-160
– EDM-200
The EDM-80 is available in four different
versions all with airflow performances of 80
m3/hr.
– The EDM-200 is available in seven different
versions all with airflow performances of
180m3/hr.
– The EDM-200 S is the basic model, then the
other six models are available incorporating
a neon light, adjustable or fixed Run-OnTimer, automatic shutter, pull cord switch
and adjustable humidistat.
Construction
– EDM-80: Basic Model
– EDM-80 L: This model is designed to be
fitted in the place of a natural ventilation
grille, 10 x 20 cm.
– EDM-80 T and 80 LT: These two models are
identical to the above with the addition of an
adjustable Run-On-Timer facility. The timer
can be varied between 1 – 30 minutes.
– The EDM-100 is available in twelve different
versions all with airflow performances of 95
m3/hr.
– The EDM-100 S is the basic model, then
other versions are available incorporating
neon lights, adjustable or fixed run-on-timer,
automatic shutter, pull cord switch, photoelectric cell operation, adjustable humidistat
and glass mounting adapter.
– The EDM-100 12V are Safety Extra Low
Voltage axial extractors for domestic bathroom, shower, and toilet areas. The fans are
designed for the safe operation within water
spray areas of bathrooms and toilet areas.
– The EDM-160 is available in two different
versions all with airflow performances of 160
m3/hr.
– EDM-160: Basic Model.
– EDM-160 R: This model incorporates a fixed
Run-On-Timer facility. The timer is pre-set
for 8 minutes additional operation after the
user has switched the fan off.
218
The EDM extractor fan casings and impellers
are manufactured from tough injection
moulded plastic. The following standard
specifications apply:
–(
) Class ll electrical insulation
–(
) Splash-proof protection
All motors are single-phase, shaded pole,
type:
– 230V – 50Hz.
These low consumption electric motors are
fitted with internal thermal protection device
to protect against abnormal overheating:
– by impedance on the EDM-80 and EDM-100.
– by thermal fuse on the EDM-160 and
EDM-200.
The maximum working ambient air temperature for the EDM series models is 40 ºC. The
motors from the EDM series can be speed
controlled by means of voltage regulation.
EDM-80 / EDM-80 L
Applications
Reference
Designed specifically for the extraction of
odours and moisture from toilets, bathrooms
and all small rooms requiring ventilation.
E D M
8
0
L R
2
1
3
1 – Model series
2 – Maximum air flow
3 – Model “options”
R – Run-On-Timer
L – Replacement grille format
configuration
LR – Model L with Run-On-Timer
Performance curve
Technical characteristics
EDM/80
EDM-80
EDM-80 L
EDM 80L
Pe
Pe
"
Type
Speed
Maximum
Voltage
Maximum
Sound
power
(V)
air
pressure
Weight
Pa
Pa
mm.c.d.a.
mmWG
1,4
absorbed
at
flow
level
(r.p.m.)
(W)
at 50 Hz
(m3/h)
(dB(A))
(kg)
EDM-80 / 80 L
2500
13
220-240
80
33
0,4
EDM-80 R / 80 RL
2500
13
220-240
80
33
0,4
12
1,2
10
8
1,0
0,8
6
0,6
4
0,4
2
0,2
0
0
Installation examples
0
0
Ceiling or wall
mounting extract
ventilation.
Extract ventilation
though wall or using
a shunt duct system.
Extract ventilation
with telescopic duct
for double walls.
EDM-80L for use in
place of 10 x 20cm
ventilation grilles.
Accessories
GSA 100
Flexible
aluminium
duct
V-23 / V-24
Wall kit with fixed or
automatic shutter.
CX 125
Worm drive ducting
clips.
219
15
30
45
60
0,01
Dimensions (mm)
75
0,02
90
105
m3/h
Q
m3/s
EDM-100
Applications
Reference
The EDM-100 models are suitable for the
extraction of odours and moisture from toilets,
bathrooms and all small rooms requiring ventilation.
E D M
1 0 0
C R
1
2
3
1 – Model series
2 – Maximum air flow
3 – Model options, see following page
Performance curve
Technical characteristics
"
Tipo
Speed
Maximum
Voltage
Maximjm
Sound
power
(V)
air
pressure
Weight
EDM-100
EDM-100
Pe
Pa
Pa
absorbed
at
flow
level
(r.p.m.)
(W)
50 Hz
(m3/h)
(dB(A))
(kg)
2450
13
230
95
40
0,48
mmCE
mmWG
3,5
30
3
EDM-100
25
2,5
Installation examples
20
2
15
1,5
10
1
5
0,5
0
0
0
Ceiling or wall
mounting extract
ventilation.
Extract ventilation
though wall or using
a shunt duct system.
Extract ventilation
with telescopic duct
for double walls.
Glass mounted with
special kit (Model
EDM-100 VM)
Accessories
0
20
40
60
0,01
Dimensions (mm)
GSA 100
Flexible aluminium
duct
GRA
Aluminium exterior
grille
CX 125
Worm drive ducting
clips
V-23 / V-24
Wall kit with fixed or
automatic shutter
PER-100W
Backdraught shutter
CM-130
Over pressure shutter
220
80
0,02
100
(m3/h)
m3/h
Q
m3/s
EXTRACTEURS HELICOIDES
EDM-100
Models
EDM-100 C
EDM-100 CH
EDM-100 VM
EDM-100S
Basic Model
EDM-100 CT
The same characteristics as the EDM-100 C
model and in addition:
– Fixed period (8 mins) Run-On-Timer.
EDM-100 M
The same characteristics as the basic
EDM-100 S model and in addition:
– Neon pilot light, power-on indication.
– Automatic back draught shutter.
– Pull cord switch.
EDM-100 T
The same characteristics as the basic model
and in addition:
– Neon pilot light, power-on indication.
– Fixed period (8 mins) Run-On-Timer.
EDM-100 CR
The same characteristics as the EDM-100 C
model and in addition:
– Adjustable period (2-20 mins) Run-OnTimer.
EDM-100 R
The same characteristics as the basic model
and in addition:
– Neon pilot light, power-on indication.
– Adjustable period (2-20 mins) Run-OnTimer.
EDM-100 VM
– The same characteristics as the basic
EDM-100 S model and in addition:
– Neon pilot light, power-on indication.
– Automatic back draught shutter.
– Pull cord switch.
– Spacer to facilitate mounting the fan in all
types of glass (single and double glazed)
– Hole diameter: 106mm
EDM-100 EC
The same characteristics as the EDM-100 C
model and in addition:
– Adjustable period (2-20 mins) Run-OnTimer.
– Photoelectric cell enabling the automatic
operation of the fan by light detection.
EDM-100 H
The same characteristics as the basic model
and in addition:
– Neon pilot light, power-on indication.
– Adjustable Humidistat (between 65-90%
and RH). When the level of humidity rises
above the selected level, the fan is automatically switched On.
EDM-100 VMH
The same characteristics as the basic
EDM-100 VM model and in addition:
– Adjustable Humidistat (between 65-90&
RH). When the level of humidity rises above
the selected level, the fan is automatically
switched On.
EDM-100 CH
The same characteristics as the basic model
and in addition:
– Adjustable Humidistat (between 65-90%
and RH). When the level of humidity rises
above the selected level, the fan is automatically switched On.
– Pull cord switch.
EDM-100 C
The same characteristics as the basic model
and in addition:
– Neon pilot light, power-on indication.
– Automatic back draught shutter.
"
Features/Models
EDM-100 S EDM-100 T EDM-100 R EDM-100 H EDM-100 C EDM-100 CT EDM-100 CR EDM-100 EC EDM-100 CH EDM-100 M EDM-100 VM EDM-100 VMH
Neon pilot light
•
Fixed period Run-On-Timer
•
Adjustable period
Run-On-Timer
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Automatic shutter
•
•
Photoelectric cell
Adjustable humidistat
•
•
Pull cord switch
•
•
•
•
•
Adaptation for glass
•
•
Exterior grille
•
•
221
•
EDM-100-12V
Construction
Performance curve
The EDM-100-12V models are manufactured
from tough injection moulded plastic and
incorporate the following specifications:
– IP57 safety protection.
– Class III electrical insulation.
PePe
Pa
Pa
EDM-100-12V
EDM-100-12V
mmWG
mmCE
3,5
30
The range includes the following models:
– EDM-100 S 12V (basic model)
– EDM-100 C 12V (model with automatic back
draught shutter and neon pilot light power-on
indication).
3
25
20
The fans must be operated through a safety
operated transformer 230V / 12V (model
CT-12/14).
2,5
2
15
1,5
10
1
Technical characteristics
"
Type
Speed
Maximum
Voltage
Maximum
Sound
power
absorbed
(V)
air
pressure
at
flow
level
(dB(A))
(kg)
5
0,5
0
0
Weight
0
20
40
60
80
100
(m3/h)
Q
(r.p.m.)
(W)
50 Hz
(m3/h)
EDM-100S-12V
2100
7
12
85
37
0,48
EDM-100C-12V
2100
11
12
85
37
0,48
0
0,01
0,02
Dimensions (mm)
Accessories
Transformer CT-12/14
Safety isolating transformer which must be used with the EDM-100-12V
fans and should be located out of the reach of the water spray or person
using a bath or shower.
– Supply Voltage / Output Voltage: 230V / 12V 50Hz single phase.
– IP21. Class II double insulated appliance.
– Incorporates and internal fuse (replaceable).
GRA-70
Aluminium exterior
grille
PER-100W
Exterior backdraught
shutter
GSA-100
Flexible aluminium
duct
V-23 / V-24
Wall kit with fixed
or automatic shutter
EDM-100-12V
TRANSFORMER CT-12/14
83,5
43
CX-125
Worm drive ducting
clips
130
222
(m3/s)
The EDM-160 models are suitable for the extraction of odours and moisture from toilets, bathrooms, utility and all small rooms requiring ventilation.
The transformer (CT-12/14) included with all low voltage EDM fans must be installed away from direct sources of water spray and out of reach of a
person using a bath or shower (by definition this prohibited area area for installation consists of an area of 1m in length x 1m in width x 2.5m in
height around the bath or shower fixtures).
223
EDM-160
Applications
Reference
The EDM-160 models are suitable for the
extraction of odours and moisture from toilets,
bathrooms, utility and all small rooms requiring
ventilation.
E D M
1 6 0
R
1
2
3
1 – Model series
2 – Maximum air flow
3 – Model options
– R : Adjustable Run-On-Timer
Performance curve
Technical characteristics
"
Type
Speed
Maximun
Voltage
Maximum
Sound
power
(V)
air
pressure
Weight
absorbed
at
flow
level
(r.p.m.)
(W)
50 Hz
(m3/h)
(dB(A))
(kg)
EDM-160
2500
35
230
160
46
1
EDM-160 R
2500
35
230
160
46
1
Pe
Pa
Pa
EDM-160
mmCE
mmWG
EDM-160
6
Installation
50
5
40
4
30
3
20
2
10
1
0
0
0
100
120
140
160
m3/h
Q
3
0,05 m /s
180
m3/h
0
Ceiling or wall mounting extract
ventilation.
Extract ventilation though wall
or using a shunt duct system.
Accessories
GSA
Flexible aluminium
duct
PER
Backdraught shutter
CX
Worm drive ducting
clips
GRA
Aluminium exterior
grille
CM 130
Backdraught shutter
224
0,03
0,04
Dimensions (mm)
EDM-200
Applications- Insttallation
The EDM-200 models are suitable for the
extraction of odours and moisture from large
toilets, bathrooms, utility and all small rooms
requiring ventilation.
Ø 122-125
Ø 120-125
▼
▼
▼
Technical characteristics
Performance curve
"
Type
Speed
Voltage
(V)
at
50 Hz
Maximum
air
flow
(m3/h)
Sound
pressure
level*
(dB(A))
Weight
(r.p.m.)
Maximum
power
absorbed
(W)
2500
25
220-240
180
46
0,9
EDM-200
EDM-200
Pe
(kg)
Pa
mmWG
*at 1.5m distance.
Models
"
EDM-200 S EDM-200 T EDM-200 H EDM-200 C EDM-200 CT
Neon pilot light
•
Fixed period
Run-On-Timer
•
•
•
EDM-200 CR EDM-200 CH
•
•
•
•
Adjustable period
Run-on-Timer
•
•
Automatic shutter
•
•
•
Adjustable humidistat
•
•
Pull cord switch
•
•
Accessories
Dimensions (mm)
GSA
Flexible aluminium
duct
PER
Backdraught shutter.
CM 130
Backdraught shutter
CX
Worm drive ducting
clips
GRA
Aluminium exterior
grille
225
Ø 118,4
Features/Models
61,5
186,5
109,16