AXIAL EXTRACTORS EDM Series EDM 80-EDM 80L Description The EDM Series of axial extractor fans consists of four nominal product sizes, the EDM-80 -100,-160 and -200 models. The EDM series have been designed for domestic ventilation applications and are easy to install, offer quiet operation, aesthetically pleasing and are available with a variety of operational specifications. Air flow performances range from 80 up to 200 m3/hr. The EDM Series are ideally suited for wall or ceiling mounted installations and for short duct run extract applications. To compliment the fans a wide range of ancillary accessories are available. EDM 100 EDM 200 Range The EDM Series consists of four different models: – EDM-80 – EDM-100 – EDM-160 – EDM-200 The EDM-80 is available in four different versions all with airflow performances of 80 m3/hr. – The EDM-200 is available in seven different versions all with airflow performances of 180m3/hr. – The EDM-200 S is the basic model, then the other six models are available incorporating a neon light, adjustable or fixed Run-OnTimer, automatic shutter, pull cord switch and adjustable humidistat. Construction – EDM-80: Basic Model – EDM-80 L: This model is designed to be fitted in the place of a natural ventilation grille, 10 x 20 cm. – EDM-80 T and 80 LT: These two models are identical to the above with the addition of an adjustable Run-On-Timer facility. The timer can be varied between 1 – 30 minutes. – The EDM-100 is available in twelve different versions all with airflow performances of 95 m3/hr. – The EDM-100 S is the basic model, then other versions are available incorporating neon lights, adjustable or fixed run-on-timer, automatic shutter, pull cord switch, photoelectric cell operation, adjustable humidistat and glass mounting adapter. – The EDM-100 12V are Safety Extra Low Voltage axial extractors for domestic bathroom, shower, and toilet areas. The fans are designed for the safe operation within water spray areas of bathrooms and toilet areas. – The EDM-160 is available in two different versions all with airflow performances of 160 m3/hr. – EDM-160: Basic Model. – EDM-160 R: This model incorporates a fixed Run-On-Timer facility. The timer is pre-set for 8 minutes additional operation after the user has switched the fan off. 218 The EDM extractor fan casings and impellers are manufactured from tough injection moulded plastic. The following standard specifications apply: –( ) Class ll electrical insulation –( ) Splash-proof protection All motors are single-phase, shaded pole, type: – 230V – 50Hz. These low consumption electric motors are fitted with internal thermal protection device to protect against abnormal overheating: – by impedance on the EDM-80 and EDM-100. – by thermal fuse on the EDM-160 and EDM-200. The maximum working ambient air temperature for the EDM series models is 40 ºC. The motors from the EDM series can be speed controlled by means of voltage regulation. EDM-80 / EDM-80 L Applications Reference Designed specifically for the extraction of odours and moisture from toilets, bathrooms and all small rooms requiring ventilation. E D M 8 0 L R 2 1 3 1 – Model series 2 – Maximum air flow 3 – Model “options” R – Run-On-Timer L – Replacement grille format configuration LR – Model L with Run-On-Timer Performance curve Technical characteristics EDM/80 EDM-80 EDM-80 L EDM 80L Pe Pe " Type Speed Maximum Voltage Maximum Sound power (V) air pressure Weight Pa Pa mm.c.d.a. mmWG 1,4 absorbed at flow level (r.p.m.) (W) at 50 Hz (m3/h) (dB(A)) (kg) EDM-80 / 80 L 2500 13 220-240 80 33 0,4 EDM-80 R / 80 RL 2500 13 220-240 80 33 0,4 12 1,2 10 8 1,0 0,8 6 0,6 4 0,4 2 0,2 0 0 Installation examples 0 0 Ceiling or wall mounting extract ventilation. Extract ventilation though wall or using a shunt duct system. Extract ventilation with telescopic duct for double walls. EDM-80L for use in place of 10 x 20cm ventilation grilles. Accessories GSA 100 Flexible aluminium duct V-23 / V-24 Wall kit with fixed or automatic shutter. CX 125 Worm drive ducting clips. 219 15 30 45 60 0,01 Dimensions (mm) 75 0,02 90 105 m3/h Q m3/s EDM-100 Applications Reference The EDM-100 models are suitable for the extraction of odours and moisture from toilets, bathrooms and all small rooms requiring ventilation. E D M 1 0 0 C R 1 2 3 1 – Model series 2 – Maximum air flow 3 – Model options, see following page Performance curve Technical characteristics " Tipo Speed Maximum Voltage Maximjm Sound power (V) air pressure Weight EDM-100 EDM-100 Pe Pa Pa absorbed at flow level (r.p.m.) (W) 50 Hz (m3/h) (dB(A)) (kg) 2450 13 230 95 40 0,48 mmCE mmWG 3,5 30 3 EDM-100 25 2,5 Installation examples 20 2 15 1,5 10 1 5 0,5 0 0 0 Ceiling or wall mounting extract ventilation. Extract ventilation though wall or using a shunt duct system. Extract ventilation with telescopic duct for double walls. Glass mounted with special kit (Model EDM-100 VM) Accessories 0 20 40 60 0,01 Dimensions (mm) GSA 100 Flexible aluminium duct GRA Aluminium exterior grille CX 125 Worm drive ducting clips V-23 / V-24 Wall kit with fixed or automatic shutter PER-100W Backdraught shutter CM-130 Over pressure shutter 220 80 0,02 100 (m3/h) m3/h Q m3/s EXTRACTEURS HELICOIDES EDM-100 Models EDM-100 C EDM-100 CH EDM-100 VM EDM-100S Basic Model EDM-100 CT The same characteristics as the EDM-100 C model and in addition: – Fixed period (8 mins) Run-On-Timer. EDM-100 M The same characteristics as the basic EDM-100 S model and in addition: – Neon pilot light, power-on indication. – Automatic back draught shutter. – Pull cord switch. EDM-100 T The same characteristics as the basic model and in addition: – Neon pilot light, power-on indication. – Fixed period (8 mins) Run-On-Timer. EDM-100 CR The same characteristics as the EDM-100 C model and in addition: – Adjustable period (2-20 mins) Run-OnTimer. EDM-100 R The same characteristics as the basic model and in addition: – Neon pilot light, power-on indication. – Adjustable period (2-20 mins) Run-OnTimer. EDM-100 VM – The same characteristics as the basic EDM-100 S model and in addition: – Neon pilot light, power-on indication. – Automatic back draught shutter. – Pull cord switch. – Spacer to facilitate mounting the fan in all types of glass (single and double glazed) – Hole diameter: 106mm EDM-100 EC The same characteristics as the EDM-100 C model and in addition: – Adjustable period (2-20 mins) Run-OnTimer. – Photoelectric cell enabling the automatic operation of the fan by light detection. EDM-100 H The same characteristics as the basic model and in addition: – Neon pilot light, power-on indication. – Adjustable Humidistat (between 65-90% and RH). When the level of humidity rises above the selected level, the fan is automatically switched On. EDM-100 VMH The same characteristics as the basic EDM-100 VM model and in addition: – Adjustable Humidistat (between 65-90& RH). When the level of humidity rises above the selected level, the fan is automatically switched On. EDM-100 CH The same characteristics as the basic model and in addition: – Adjustable Humidistat (between 65-90% and RH). When the level of humidity rises above the selected level, the fan is automatically switched On. – Pull cord switch. EDM-100 C The same characteristics as the basic model and in addition: – Neon pilot light, power-on indication. – Automatic back draught shutter. " Features/Models EDM-100 S EDM-100 T EDM-100 R EDM-100 H EDM-100 C EDM-100 CT EDM-100 CR EDM-100 EC EDM-100 CH EDM-100 M EDM-100 VM EDM-100 VMH Neon pilot light • Fixed period Run-On-Timer • Adjustable period Run-On-Timer • • • • • • • • • • • • • • • • • • • • • Automatic shutter • • Photoelectric cell Adjustable humidistat • • Pull cord switch • • • • • Adaptation for glass • • Exterior grille • • 221 • EDM-100-12V Construction Performance curve The EDM-100-12V models are manufactured from tough injection moulded plastic and incorporate the following specifications: – IP57 safety protection. – Class III electrical insulation. PePe Pa Pa EDM-100-12V EDM-100-12V mmWG mmCE 3,5 30 The range includes the following models: – EDM-100 S 12V (basic model) – EDM-100 C 12V (model with automatic back draught shutter and neon pilot light power-on indication). 3 25 20 The fans must be operated through a safety operated transformer 230V / 12V (model CT-12/14). 2,5 2 15 1,5 10 1 Technical characteristics " Type Speed Maximum Voltage Maximum Sound power absorbed (V) air pressure at flow level (dB(A)) (kg) 5 0,5 0 0 Weight 0 20 40 60 80 100 (m3/h) Q (r.p.m.) (W) 50 Hz (m3/h) EDM-100S-12V 2100 7 12 85 37 0,48 EDM-100C-12V 2100 11 12 85 37 0,48 0 0,01 0,02 Dimensions (mm) Accessories Transformer CT-12/14 Safety isolating transformer which must be used with the EDM-100-12V fans and should be located out of the reach of the water spray or person using a bath or shower. – Supply Voltage / Output Voltage: 230V / 12V 50Hz single phase. – IP21. Class II double insulated appliance. – Incorporates and internal fuse (replaceable). GRA-70 Aluminium exterior grille PER-100W Exterior backdraught shutter GSA-100 Flexible aluminium duct V-23 / V-24 Wall kit with fixed or automatic shutter EDM-100-12V TRANSFORMER CT-12/14 83,5 43 CX-125 Worm drive ducting clips 130 222 (m3/s) The EDM-160 models are suitable for the extraction of odours and moisture from toilets, bathrooms, utility and all small rooms requiring ventilation. The transformer (CT-12/14) included with all low voltage EDM fans must be installed away from direct sources of water spray and out of reach of a person using a bath or shower (by definition this prohibited area area for installation consists of an area of 1m in length x 1m in width x 2.5m in height around the bath or shower fixtures). 223 EDM-160 Applications Reference The EDM-160 models are suitable for the extraction of odours and moisture from toilets, bathrooms, utility and all small rooms requiring ventilation. E D M 1 6 0 R 1 2 3 1 – Model series 2 – Maximum air flow 3 – Model options – R : Adjustable Run-On-Timer Performance curve Technical characteristics " Type Speed Maximun Voltage Maximum Sound power (V) air pressure Weight absorbed at flow level (r.p.m.) (W) 50 Hz (m3/h) (dB(A)) (kg) EDM-160 2500 35 230 160 46 1 EDM-160 R 2500 35 230 160 46 1 Pe Pa Pa EDM-160 mmCE mmWG EDM-160 6 Installation 50 5 40 4 30 3 20 2 10 1 0 0 0 100 120 140 160 m3/h Q 3 0,05 m /s 180 m3/h 0 Ceiling or wall mounting extract ventilation. Extract ventilation though wall or using a shunt duct system. Accessories GSA Flexible aluminium duct PER Backdraught shutter CX Worm drive ducting clips GRA Aluminium exterior grille CM 130 Backdraught shutter 224 0,03 0,04 Dimensions (mm) EDM-200 Applications- Insttallation The EDM-200 models are suitable for the extraction of odours and moisture from large toilets, bathrooms, utility and all small rooms requiring ventilation. Ø 122-125 Ø 120-125 ▼ ▼ ▼ Technical characteristics Performance curve " Type Speed Voltage (V) at 50 Hz Maximum air flow (m3/h) Sound pressure level* (dB(A)) Weight (r.p.m.) Maximum power absorbed (W) 2500 25 220-240 180 46 0,9 EDM-200 EDM-200 Pe (kg) Pa mmWG *at 1.5m distance. Models " EDM-200 S EDM-200 T EDM-200 H EDM-200 C EDM-200 CT Neon pilot light • Fixed period Run-On-Timer • • • EDM-200 CR EDM-200 CH • • • • Adjustable period Run-on-Timer • • Automatic shutter • • • Adjustable humidistat • • Pull cord switch • • Accessories Dimensions (mm) GSA Flexible aluminium duct PER Backdraught shutter. CM 130 Backdraught shutter CX Worm drive ducting clips GRA Aluminium exterior grille 225 Ø 118,4 Features/Models 61,5 186,5 109,16
© Copyright 2024