HSR Range Bowthorpe EMP Transmission Surge Arrester Metal oxide arrester (ZnO) Polymeric Housing IEC 60099-4 Nominal discharge current: 10 kA Line discharge class 2 High current impulse 4/10 µs: 100 kA Energy Capability: 4.5 kJ/kV at Ur according to IEC 60099-4 (Clause 8.4.2 table 5 & 8.5.5) Surge Arrester Characteristics Rated voltage: Continuous operating voltage: TOV Capability: Outdoor application Rated short circuit current: Max. App. Cant. Load Pull Strength: Impulse voltage -1,2/50 µs: Power frequency voltage- wet: Flashover Distance: Creepage Length: Approx. Weight: Maximum Residual Voltages Lightning current impulse 8/20 µs 5 kA 30.8 kV 10 kA 33.1 kV 20 kA 36.5 kV 40 kA 41.5 kV HSRAP12 Line Terminal Ground Terminal Mounting Drawing: BOW-4-001 Ur : 12.0 Uc : 9.60 Tc : 14.2 40 2513 5000 195 61.1 249 600 1.9 kV kV kV for 1s kA N N kV kV mm mm kg Steep lightning current impulse 1/20 µs 10 kA 20 kA 35.5 kV 39.3 kV Switching current impulse 30/60 µs 125 A 24.4 kV 250 A 25.1 kV 500 A 25.9 kV 1000A 27.0 kV 2000 A 28.3 kV * Residual voltage correction factor as per IEC recommendation 10kV/10kA/m Power frequency voltage versus time with prior energy Marking 1.25 RATIO OF WITHSTAND VOLTAGE (Uw) / RATED VOLTAGE (Ur) 1.15 1.10 1.05 1.00 0.95 1 TIME (s) 10 100 1000 10000 All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users, however, should independently evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particular quality or performance. Such an assurance is only provided in the context of our product specifications or explicit contractual arrangements. Our liability for these products is set forth in our standard terms and conditions of sale. Bowthorpe EMP, TE Logo and Tyco Electronics are trademarks. Technical Information: - Contact Product Management Brighton UK (+44 (0)1273 692591) Tyco Electronics UK Ltd.. Stevenson Road, Brighton. East Sussex. BN2 0DF England Phone: +44-(0)1273-692591, Fax: +44-(0)1273-601741 http://energy.tycoelectronics.com BOW-EPP-HSRAP12-03-07 ZnO - Surge - Arrester ISC 40 kA IN 10 kA, class 2 HSRAP12 IEC 60099-4 Manufacturing Year Ur : 12.0 kV Uc : 9.60 kV 1.20 HSR Range Bowthorpe EMP Transmission Surge Arrester Metal oxide arrester (ZnO) Polymeric Housing IEC 60099-4 Nominal discharge current: 10 kA Line discharge class 2 High current impulse 4/10 µs: 100 kA Energy Capability: 4.5 kJ/kV at Ur according to IEC 60099-4 (Clause 8.4.2 table 5 & 8.5.5) Surge Arrester Characteristics Rated voltage: Continuous operating voltage: TOV Capability: Outdoor application Rated short circuit current: Max. App. Cant. Load Pull Strength: Impulse voltage -1,2/50 µs: Power frequency voltage- wet: Flashover Distance: Creepage Length: Approx. Weight: Maximum Residual Voltages Lightning current impulse 8/20 µs 5 kA 73.9 kV 10 kA 79.4 kV 20 kA 87.6 kV 40 kA 99.6 kV HSRCP30 Line Terminal Ground Terminal Mounting Drawing: BOW-4-003 Ur : 30.0 Uc : 24.0 Tc : 35.4 40 1210 5000 267 142 482 1325 6.0 kV kV kV for 1s kA N N kV kV mm mm kg Steep lightning current impulse 1/20 µs 10 kA 20 kA 85.3 kV 94.3 kV Switching current impulse 30/60 µs 125 A 58.6 kV 250 A 60.2 kV 500 A 62.3 kV 1000A 64.7 kV 2000 A 67.9 kV * Residual voltage correction factor as per IEC recommendation 10kV/10kA/m Power frequency voltage versus time with prior energy Marking 1.25 RATIO OF WITHSTAND VOLTAGE (Uw) / RATED VOLTAGE (Ur) 1.15 1.10 1.05 1.00 0.95 1 TIME (s) 10 100 1000 10000 All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users, however, should independently evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particular quality or performance. Such an assurance is only provided in the context of our product specifications or explicit contractual arrangements. Our liability for these products is set forth in our standard terms and conditions of sale. Bowthorpe EMP, TE Logo and Tyco Electronics are trademarks. Technical Information: - Contact Product Management Brighton UK (+44 (0)1273 692591) Tyco Electronics UK Ltd.. Stevenson Road, Brighton. East Sussex. BN2 0DF England Phone: +44-(0)1273-692591, Fax: +44-(0)1273-601741 http://energy.tycoelectronics.com BOW-EPP-HSRCP30-03-07 ZnO - Surge - Arrester ISC 40 kA IN 10 kA, class 2 HSRCP30 IEC 60099-4 Manufacturing Year Ur : 30.0 kV Uc : 24.0 kV 1.20
© Copyright 2024