MasterCool Refrigeration Side-by-Side Merging Combinations For SF Models mieleusa.com

MasterCool Refrigeration
Side-by-Side Merging Combinations
For SF Models
8mieleusa.com
Side-by-Side Merging Kit
KSK 1002
en
This merging kit should be used for
side-by-side installation of the following
models:
en
Side-by-side
. . . with partition
. . . without partition
The minimum thickness of the partition
is 5/8" (16 mm).
If there is a partition with a thickness
from 5/8" (16 mm) to 6 5/16" (160 mm)
between the adjacent appliances, then
each appliance should be individually
installed within its own niche using the
mounting accessories included.
– K 18x1 SF, K 19x1 SF,
K 18x3 SF, K 19x3 SF
– F 14x1 SF, F 18x1 SF, F 19x1 SF
F 14x3 SF, F 18x3 SF, F 19x3 SF
– KF 18x1 SF, KF 19x1 SF,
KF 18x3 SF, KF 19x3 SF
– KWT 16x1 SF, KWT 16x3 SF
If the appliances are installed directly
next to each other (without a partition),
they need to be attached together. A
heating mat must also be installed. This
will help avoid condensation and
prevent damages.
In this case, you will only need the
heating mat from the "Merging Kit" to
avoid condensation and prevent
damages.
4
3
Page 2 of 12
Product and Cut-out Dimensions
48” Side-by-Side Combination
F14X3 & K18X3
FOR PROUD INSTALLATION
24" m
in.
4"
29 3/
4"
84"
17 3/
24 5/
8"
O
83 1/2" - 85 3/8"
48"
E
1 1/8
"
3 1/2" - 5 3/8"
10 1/
4"
Location Codes
E - 5 foot - 120 Volt - 15 Amp 3-wire molded plug power
supply connects lower left rear
O - One (1) Standard NEMA 5-15 Duplex Outlet - locate less
than 9" above finished floor
Notes
• KSK1002 Merging kit must be used when combining units
• All Installations must be done in accordance with local codes
Page 3 of 12
Product and Cut-out Dimensions
48” Side-by-Side Combination
F14X3 & K18X3
FOR FLUSH INSTALLATION
25" m
in.
4"
29 3/
4"
84"
17 3/
24 5/
8"
O
83 1/2" - 85 3/8"
48"
E
1 1/8
"
3 1/2" - 5 3/8"
10 1/
4"
Location Codes
E - 5 foot - 120 Volt - 15 Amp 3-wire molded plug power
supply connects lower left rear
O - One (1) Standard NEMA 5-15 Duplex Outlet - locate less
than 9" above finished floor
Notes
• KSK1002 Merging kit must be used when combining units
• All Installations must be done in accordance with local codes
• Sides of adjoining cabinets should be filled (flush to frame)
to insure proper fit and finish
Page 4 of 12
Product and Cut-out Dimensions
54” Side-by-Side Combination
F14X3 & K19X3
FOR PROUD INSTALLATION
24" m
in.
4"
35 3/
4"
84"
17 3/
24 5/
8"
O
83 1/2" - 85 3/8"
54"
E
1 1/8
"
3 1/2" - 5 3/8"
10 1/
4"
Location Codes
E - 5 foot - 120 Volt - 15 Amp 3-wire molded plug power
supply connects lower left rear
O - One (1) Standard NEMA 5-15 Duplex Outlet - locate less
than 9" above finished floor
Notes
• KSK1002 Merging kit must be used when combining units
• All Installations must be done in accordance with local codes
Page 5 of 12
Product and Cut-out Dimensions
54” Side-by-Side Combination
F14X3 & K19X3
FOR FLUSH INSTALLATION
25" m
in.
4"
35 3/
4"
84"
17 3/
24 5/
8"
O
83 1/2" - 85 3/8"
54"
E
1 1/8
"
Location Codes
3 1/2" - 5 3/8"
10 1/
4"
E - 5 foot - 120 Volt - 15 Amp 3-wire molded plug power
supply connects lower left rear
O - One (1) Standard NEMA 5-15 Duplex Outlet - locate less
than 9" above finished floor
Notes
• KSK1002 Merging kit must be used when combining units
• All Installations must be done in accordance with local codes
• Sides of adjoining cabinets should be filled (flush to frame)
to insure proper fit and finish
Page 6 of 12
Product and Cut-out Dimensions
60” Side-by-Side Combination
F18X3 & K18X3
FOR PROUD INSTALLATION
24" m
in.
4"
29 3/
4"
84"
29 3/
24 5/
8"
O
83 1/2" - 85 3/8"
60"
E
1 1/8
"
Location Codes
3 1/2" - 5 3/8"
10 1/
4"
E - 5 foot - 120 Volt - 15 Amp 3-wire molded plug power
supply connects lower left rear
O - One (1) Standard NEMA 5-15 Duplex Outlet - locate less
than 9" above finished floor
Notes
• KSK1002 Merging kit must be used when combining units
• All Installations must be done in accordance with local codes
Page 7 of 12
Product and Cut-out Dimensions
60” Side-by-Side Combination
F18X3 & K18X3
FOR FLUSH INSTALLATION
25" m
in.
4"
29 3/
4"
84"
29 3/
24 5/
8"
O
83 1/2" - 85 3/8"
60"
E
1 1/8
"
3 1/2" - 5 3/8"
10 1/
4"
Location Codes
E - 5 foot - 120 Volt - 15 Amp 3-wire molded plug power
supply connects lower left rear
O - One (1) Standard NEMA 5-15 Duplex Outlet - locate less
than 9" above finished floor
Notes
• KSK1002 Merging kit must be used when combining units
• All Installations must be done in accordance with local codes
• Sides of adjoining cabinets should be filled (flush to frame)
to insure proper fit and finish
Page 8 of 12
Product and Cut-out Dimensions
66” Side-by-Side Combination
F18X3 & K19X3
FOR PROUD INSTALLATION
24" m
in.
4"
35 3/
4"
84"
29 3/
24 5/
8"
O
83 1/2" - 85 3/8"
66"
E
1 1/8
"
3 1/2" - 5 3/8"
10 1/
4"
Location Codes
E - 5 foot - 120 Volt - 15 Amp 3-wire molded plug power
supply connects lower left rear
O - One (1) Standard NEMA 5-15 Duplex Outlet - locate less
than 9" above finished floor
Notes
• KSK1002 Merging kit must be used when combining units
• All Installations must be done in accordance with local codes
Page 9 of 12
Product and Cut-out Dimensions
66” Side-by-Side Combination
F18X3 & K19X3
FOR FLUSH INSTALLATION
25" m
in.
4"
35 3/
4"
84"
29 3/
24 5/
8"
O
83 1/2" - 85 3/8"
66"
E
1 1/8
"
3 1/2" - 5 3/8"
10 1/
4"
Location Codes
E - 5 foot - 120 Volt - 15 Amp 3-wire molded plug power
supply connects lower left rear
O - One (1) Standard NEMA 5-15 Duplex Outlet - locate less
than 9" above finished floor
Notes
• KSK1002 Merging kit must be used when combining units
• All Installations must be done in accordance with local codes
• Sides of adjoining cabinets should be filled (flush to frame)
to insure proper fit and finish
Page 10 of 12
Product and Cut-out Dimensions
72” Side-by-Side Combination
F19X3 & K19X3
FOR PROUD INSTALLATION
24" m
in.
4"
35 3/
4"
84"
35 3/
24 5/
8"
O
83 1/2" - 85 3/8"
72"
E
1 1/8
"
3 1/2" - 5 3/8"
10 1/
4"
Location Codes
E - 5 foot - 120 Volt - 15 Amp 3-wire molded plug power
supply connects lower left rear
O - One (1) Standard NEMA 5-15 Duplex Outlet - locate less
than 9" above finished floor
Notes
• KSK1002 Merging kit must be used when combining units
• All Installations must be done in accordance with local codes
Page 11 of 12
Product and Cut-out Dimensions
72” Side-by-Side Combination
K19X3 & F19X3
FOR FLUSH INSTALLATION
25" m
in.
4"
35 3/
4"
84"
35 3/
24 5/
8"
O
83 1/2" - 85 3/8"
72"
E
1 1/8
"
3 1/2" - 5 3/8"
10 1/
4"
Location Codes
E - 5 foot - 120 Volt - 15 Amp 3-wire molded plug power
supply connects lower left rear
O - One (1) Standard NEMA 5-15 Duplex Outlet - locate less
than 9" above finished floor
Notes
• KSK1002 Merging kit must be used when combining units
• All Installations must be done in accordance with local codes
• Sides of adjoining cabinets should be filled (flush to frame)
to insure proper fit and finish
Page 12 of 12