GL Board *E2 – The operator senses 2 obstructions before triggering a limit, it shuts down and alarms. Inputs with “Y” for “E2” will reset this condition. All open commands override any other command (timer, close, safety, etc…) Current Models (SL575, SL585, SL595, HS670, SW420, SW470, SW490) Old models (SL540 – SL570 – SL580 – SL590) J1 TB1 Input Name LED Function TTC E2 Recommended On External Devices 1 2 3 4 1 2 3 4 Radio Shadow Stop Close 5 6 5 6 Common S Open 7 7 H Open 8 9 8 9 Int Loop ObsOpen 10 10 ObsClose J4-1 J4-2 13 14 15 16 Loop Hrns Loop Hrns 11 12 13 14 15 16 17 18 19 20 off SL LT Off N Close button N/A N D21 ← D24 D29 D31 Maglock D3 R1/Xformer R2/Alarm/Xform D2 Int. Loop Wires Exit Loop Wires Y Y N N SBC, radio N Loop under a swing gate Y NC Stop button Open only radio/external exit loop detector Push button with line of sight to Open Only from any position in travel, Enables TTC. Y gate If held for 3 sec: requires constant pressure, overrides safeties, disables TTC Reverses a closing gate to the open position. Will not open a closed gate Y N Loop or photo-eye across opening Photo/Edge protecting opening Photo: Pauses an opening gate until input is cleared. N/A N cycle Edge: Reverses an opening gate to the close limit. Photo: Reverses a closing gate to the open limit. Enables TTC Photo/Edge protecting closing N Edge: Reverses a closing gate to the open limit. Disables TTC cycle Single unit must be set as master with jumper installed. Motor learn must be To connect 2 operators to move completed in single mode. Unit must be reset when changing M/S switch. at the same time (Bi-parting) Output: Closes contact when operator is on the closed limit, Releases 1 Maglock to lock gates when N/A seconds before an open command. 24V max through contacts closed (recommend swing only) Output for obstruction alarm assembly Factory installed warning alarm Y N ← Where loop wires go when using plug-in loop detector. See “Int Loop” for description Where loop wires go when using plug-in loop detector. See “S Open” for D19 description D24 Description Switch S2 Closes gate. Upon power up, will close gate from any position SW provides a longer delay when reversing directions Sets the direction of travel On=Changing other switches has no effect # Flashes 1 2 3 4 5 6 On N/A M/S Switch S1 TTC SW RT SAVE D11 Open Only, except when on the open limit will close gate. D13 Only while on a limit, prevents the gate from moving. D17 Stops gate from any position. Must be NC circuit. MUST BE ON Close from any position in travel. If held for 3 sec: requires constant D15 pressure and overrides safeties. Common terminal for inputs 1-10 Open only from any position D19 Error Code Description Single Entrapment Double Entrapment Failed or no Hall Effect sensor Exceeded max motor run time Limit Fault M/S communication failure Need to complete Motor Learn Cleared by Control Input Hard Input Hard Input Control Input ← MAG WARN OPED CLED LK off PH PH Y Y Loop wires for plug-in detectors only Loop wires for plug-in detectors N only N Description Enables maglock relay on close limit. Adds 1 sec delay on opening On = Adds 3 sec delay with alarm before gate moves. Sets functionality for terminal 9 Sets functionality for terminal 10 Probable Causes Obstruction, Force too low, clutch too loose, motor not learned, Hall effect Obstruction, Force too low, clutch too loose, motor not learned 2x , Hall effect Manual release, bad - unplugged - out of adjustment - Hall Effect Bad limit switch/nut and no chain on gate Both limits triggered, Both circuits open, unit out of phase No jumper, bad wiring, interference, needs reset, no communication Set as single master, in between limits, press motor learn, hold H open cmd for 5 sec GL Board 31
© Copyright 2024