GL Board

GL Board
*E2 – The operator senses 2 obstructions before triggering a limit, it shuts down and alarms. Inputs with “Y” for “E2” will reset this condition.
All open commands override any other command (timer, close, safety, etc…)
Current Models (SL575, SL585, SL595, HS670, SW420, SW470, SW490)
Old models (SL540 – SL570 – SL580 – SL590)
J1 TB1 Input Name LED
Function
TTC E2
Recommended
On
External Devices
1
2
3
4
1
2
3
4
Radio
Shadow
Stop
Close
5
6
5
6
Common
S Open
7
7
H Open
8
9
8
9
Int Loop
ObsOpen
10
10
ObsClose
J4-1
J4-2
13
14
15
16
Loop
Hrns
Loop
Hrns
11
12
13
14
15
16
17
18
19
20
off
SL
LT
Off
N Close button
N/A
N
D21
←
D24
D29
D31
Maglock
D3
R1/Xformer
R2/Alarm/Xform
D2
Int. Loop Wires
Exit Loop Wires
Y
Y
N
N SBC, radio
N Loop under a swing gate
Y NC Stop button
Open only radio/external exit
loop detector
Push button with line of sight to
Open Only from any position in travel, Enables TTC.
Y
gate
If held for 3 sec: requires constant pressure, overrides safeties, disables TTC
Reverses a closing gate to the open position. Will not open a closed gate
Y
N Loop or photo-eye across opening
Photo/Edge protecting opening
Photo: Pauses an opening gate until input is cleared.
N/A
N
cycle
Edge: Reverses an opening gate to the close limit.
Photo: Reverses a closing gate to the open limit. Enables TTC
Photo/Edge protecting closing
N
Edge: Reverses a closing gate to the open limit. Disables TTC
cycle
Single unit must be set as master with jumper installed. Motor learn must be
To connect 2 operators to move
completed in single mode. Unit must be reset when changing M/S switch.
at the same time (Bi-parting)
Output: Closes contact when operator is on the closed limit, Releases 1
Maglock to lock gates when
N/A
seconds before an open command. 24V max through contacts
closed (recommend swing only)
Output for obstruction alarm assembly
Factory installed warning alarm
Y
N
←
Where loop wires go when using plug-in loop detector. See “Int Loop” for
description
Where loop wires go when using plug-in loop detector. See “S Open” for
D19
description
D24
Description
Switch S2
Closes gate. Upon power up, will close gate from any position
SW provides a longer delay when reversing directions
Sets the direction of travel
On=Changing other switches has no effect
# Flashes
1
2
3
4
5
6
On
N/A
M/S
Switch S1
TTC
SW
RT
SAVE
D11 Open Only, except when on the open limit will close gate.
D13 Only while on a limit, prevents the gate from moving.
D17 Stops gate from any position. Must be NC circuit. MUST BE ON
Close from any position in travel. If held for 3 sec: requires constant
D15
pressure and overrides safeties.
Common terminal for inputs 1-10
Open only from any position
D19
Error Code Description
Single Entrapment
Double Entrapment
Failed or no Hall Effect sensor
Exceeded max motor run time
Limit Fault
M/S communication failure
Need to complete Motor Learn
Cleared by
Control Input
Hard Input
Hard Input
Control Input
←
MAG
WARN
OPED
CLED
LK
off
PH
PH
Y
Y
Loop wires for plug-in detectors
only
Loop wires for plug-in detectors
N
only
N
Description
Enables maglock relay on close limit. Adds 1 sec delay on opening
On = Adds 3 sec delay with alarm before gate moves.
Sets functionality for terminal 9
Sets functionality for terminal 10
Probable Causes
Obstruction, Force too low, clutch too loose, motor not learned, Hall effect
Obstruction, Force too low, clutch too loose, motor not learned 2x , Hall effect
Manual release, bad - unplugged - out of adjustment - Hall Effect
Bad limit switch/nut and no chain on gate
Both limits triggered, Both circuits open, unit out of phase
No jumper, bad wiring, interference, needs reset, no communication
Set as single master, in between limits, press motor learn, hold H open cmd for 5 sec
GL Board
31