Doorking 9210 Quickstart

QUICKSTART “BASIC” GUIDELINES FOR MODEL 9200 “FULL OPEN”: MOUNTED DIRECTLY ON A CONCRETE PAD
Limit Switches
V
W
PE PE
A
Hot
115 VAC Output
115 VAC
SINGLE Phase
White - Neutral
Black - 115 VAC Hot
Green - Chassis
Ground
High
Voltage
AC Input
Wire
208/230 VAC
SINGLE Phase
Use only two legs
of the incoming
3-phase power.
Check polarity of Three Phase:
Hot Hot
Position the gate half way open.
Give open command and while
gate is opening, activate the
appropriate limit switch with your
finger. Gate should STOP. If it does
Chassis
not, activate the other limit switch.
Ground
If this STOPS the gate, AC power
High
wires must be changed (Reverse
Voltage
the connection of any 2 wires and
AC Input
re-check limits).
Wire
Hot
A
115 VAC Output
208/230 VAC
THREE Phase
DIP-Switches
B
SW 1 and 2 are Upside-Down on Circuit Board.
SW 2
SW 1
D
1
23
Adjust 1 to 23 sec.
C
Plug-In Loop Detectors
See reverse side to wire main terminal.
20 19 18 17 16 15 14 13 12 11 10 9
High
Voltage
AC Input
Wire
1. Opening Direction
2. ON
3. ON
4. OFF
5. OFF
TIME
6. OFF
DELAY
7. OFF
8. OFF
B
Chassis
Ground
VERIFY Input AC power MATCHES your
specific operator power BEFORE wiring!
See reverse side
TIME
DELAY
Copyright 2013 DoorKing, Inc. All rights reserved.
D
NC
Limit Assembly Guard
3/4”conduit
with sweeps
recommended.
Attach operator to
concrete pad with
twelve (12) 1/2” x 3”
sleeve anchors (not
supplied) after
concrete pad has been
poured and has cured.
Hot
Auto-Close Timer
NO
Concrete Pad
14”
1A
2A
Limit LEDs
REV SENSE
CLOSE
14”
1/2
1
2
4404-010
A
1. OFF
2. OFF
3. OFF
4. OFF
Chain Knock-out
Chain
Bracket
Chassis
Ground
9410
Plug-In Loop
Detector
EXIT
LOOP
Chain brackets MUST be mounted so
the chain remains the same height as
it is on the idler wheels!
9410
Plug-In Loop
Detector
LMT
T
Chain
Configuration
With power OFF, push and hold the
lock plate down where shown to
adjust the Open and Close limit nuts.
After adjusting the limit-nuts, be sure
that the lock-plate is engaged in the
slots on the limit-nuts to prevent them
from rotating.
The slow-down limits on all models
but the 9210 will move up or down
3/4 inch. DO NOT remove the
slow-down limit assembly from the
3/4 inch slot and re-attach it in the
longer slot on the partial open
adjustment rail to gain further
adjustment. This will cause mechanical damage to the switch assembly
when the operator is activated.
Turn power ON and activate the gate
operator. Re-adjust the limit nuts as
necessary for full-open and full-close
gate travel. After you are satisfied with
the gate limit settings, the speed
control knob can then be adjusted on
all models but the 9210 to personal
preference.
REV SENSE
OPEN
Pad depth is determined by soil
conditions and local building codes.
Minimum depth is 18 inches.
Reinforced concrete recommended.
U
2 ft/s
LOOP
4” Min. Above Ground
Wire
Mesh
1.5 ft/s
0 ft/s
Concrete pad MUST be level!
Idler
Wheels
14”
basic I/O control
P7
14”
SCM series
1 ft/s
P6
Side
View
Speed Control Knob
REVERSE
knock-outs from
operator housing.
Speed
Controller
On all models but 9210.
P8
Idler wheels
are factory set
in the correct
Remove the chain position.
1.0
EPM
Mode
.5 ft/s
B- B+
PE
17
Gate
Frame
Operator Housing
Chain nut
and chain bolt
should not protrude
past gate frame. The chain
should sag no more than
one (1) inch per 10 feet of
travel. Do not over tighten
the chain.
L1 L2/N
Min Max
Speed
28”
Chain Bolt
cycle the operator until
the “DIP-Switches” and
the “Limit Switches”
have been adjusted.
Damage could occur to
the gate and operator.
Chain brackets MUST
align with idler
wheels so chain
stays parallel to gate!
Neu
115 VAC Output
DO NOT power up and
4”
Concrete Pad
k
in
rL
ste
Ma
4”
Hot
1 2 3 4
Chain
Nut
Operator Base Plate
Tip: It is recommended that a surge suppressor be installed on the high voltage
power lines.
High Voltage AC input power MUST MATCH
the operator specifications or DAMAGE will
occur and VOID the warranty!
ON
n2
tio
23”
2A
Chassis
Ground
GATE OPERATOR MUST BE PROPERLY GROUNDED!!
Anti-Grounding Plate
1 2 3 4 5 6 7 8
n1
Conduit
Area
it
im
2 Litch
Sw
115 VAC Convenience Outlets
A
ON
Top
View
Conduit
Area
C
Chain
Bracket
Idler Wheels
Conduit
Area
Opening direction
using ON setting.
Push
Chain
Bracket
Op
1”
1”
tio
sed
tU
No
Limit Nut
Gate
Op
en
Op
Operator MUST be parallel to gate!
Opening direction
using OFF setting.
Connect
Chain
to Gate
Pa
High Voltage Connection
DANGER
HIGH VOLTAGE!
CAUTION
Slow-Down Limit
C
l
rtia
Remove the 3 locknuts inside the electronic box
to swing box open.
P7
Remove the limit assembly guard.
Conduit suggestions:
• High voltage conduit
• Low voltage access control device conduit
• Reverse loop conduit
• Automatic exit loop conduit
1A
Push
Gain Access Inside Operator
20”
Pedestrians must be supplied with a separate access opening. For safety and installation instructions,
please refer to the Installation/Owner’s manual.
P6
it
im
1 Litch
Sw
Model 9200 is intended for installation only on sliding gates used for vehicles.
10
4-0
440
Lock-Plate
3
Never
attempt to
manually
operate the
9200 until
you have
verified that
power has
been shut-off.
Partial Open Adjustment Rail
it
ndu t
Co Cutou
2
Caution:
Limit Nut
”
te
pla
em ided
T
ite ov
son t Pr
Ma No
ox
1
18
it
ndu t
Co Cutou
t
i
ndu t
Co Cutou
cB
16
GA
TE
Oper
INJ CA
and ate
UR N
free gate
Y ORCA
of only
Do
peop whe
US
or not allow
le
DE E
andn gate
oper
AT
obst area
ate child
H
Do
gate ren
ructi is
ons.in sigh
pathnot stan .
to
play
whil d
t
in
in
e gate
gate
gate
Read
area
is path
own
mov
er’s
ing.or walk
man
thro
ual
ugh
and
safe
ty
instr
uctio
ns.
1
2
5
6
11
13A
13B
13E
25
MO
SE VIN
RIO G
US
P8
CA
Electronic Box
Hz
Clear Plastic Electronic Box Cover
60
Slow-Down Limit
Tip: Trace the base plate of the operator on a piece
of masonite (Not provided) and make a template to
help locate where the conduit runs will be positioned
in the concrete pad.
SE
D
Inc.
, Ingl
ewo
od,
REV SENSE
CLOSE
g,
ON
PHA
E LOA
rKin
ON
GAT
U.S.A.
LMT
S
Doo
Ma
cranual
stonk in
po red
siti
on
.
EXIT
LOOP
G
ERA
TOR
HP
VOL
TS
AMP
MAX
oni
REVERSE
NIN
E OP
MOD
EL
SER
IAL
ctr
WA
R
120 Glasgow Avenue
Inglewood, California 90301
Power safety and opening devices
that require 115 VAC power.
LOOP
53382
3
4
3
4
3
4
Ele
CON
ANSFOR
I/ULMS
TO
-325
CAN CER
/CSA TIFI
C22ED TO
VEH
ICU .2 NO.
CLA
LAR
247
SS
GAT
Two 115 VAC Convenience Outlets
2
1
2
1
2
1
1 2 3 4
AccManua
ess l C
Pan rank
el
1 2 3 4 5 6 7 8
All 9200 Models: DoorKing highly
recommends using the pedestal mounting stand
for gates heavier than 2000 lbs. for a more secure
attachment to a larger and heavier concrete pad.
8
7
6 5 4 3
2 1
Not included - Refer to the Installation/Owner’s manual AND
Loop Information Manual (available from www.dkaccess.com)
for more information on loops and plug-in loop detectors.
Important Note: DoorKing highly recommends that loops and
loop detectors are installed with this slide gate operator. A loop
detection system will preventing the gate from automatically
opening or closing on a vehicle when it is in the gate’s path.
9210-066-E-2-13
QUICKSTART “BASIC” GUIDELINES FOR MODEL 9200 - DIP-SWITCH AND WIRING REFERENCE
Model 9200 is intended for installation only on sliding gates used for vehicles.
Pedestrians must be supplied with a separate access opening. For safety and installation instructions, please refer to the Installation/Owner’s manual.
Main Terminal
SW 1 DIP-Switches (Right Hand Side)
Setting
Description
NO
Function
SW 1 - Right 8 Switches
U.S.A.
P7
Switch
120 Glasgow Avenue
Inglewood, California 90301
NC
Auxiliary Common
Terminal
Changes the direction
the operator will
open/close the gate.
1
Opening direction
using OFF setting.
Opening direction
using ON setting.
20 19 18 17 16 15 14 13 12 11 10 9
Connect any common
wire to these 2 terminals.
8
7
6 5 4 3
Relay activates and LED is ON when the gate is fully open.
Relay activates and LED is ON when the gate is not closed.
Relay activates and LED is ON when the gate is opening and open.
Relay activates and LED is ON when the gate is opening and closing.
Relay Activation 4-OFF 5-OFF
and
4-OFF 5-ON
4 and 5
LED Indicator 4-ON 5-OFF
Light Activation
4-ON 5-ON
OFF Normal Setting. No sound.
Warn Before
6
Operate
ON Internal alarm will sound before gate starts and throughout gate’s cycle.
Reverses Gate
Stops Gate
8
Quick-Close
Timer Override
OFF Normal Setting. Input to terminal #6 and/or reverse loops will REVERSE gate
during CLOSE cycle.
ON Input to terminal #6 and/or reverse loops will STOP gate during CLOSE cycle.
OFF Normal Setting. Timer will function normally.
ON Opening gate will stop and begin to close as soon as all reversing inputs (Reverse
loops, photo sensors) are cleared regardless of the distance the gate has opened.
SW 2 DIP-Switches (Left Hand Side)
1 2 3 4
ON
SW 2
Switch
Function
1
Self-Test
2
Gate Opens
Uphill
3
Gate Opens
Downhill
4
Spare
Upside-Down on Circuit Board.
Setting
OFF
ON
OFF
ON
OFF
ON
White Com
3-Button Control Station
DoorKing ONLY
SW 1 is Upside-Down on Board
SW 1, Switch 3 MUST be ON
except for dual operators or
exit loop partial open
applications.
Important: Controls must be
far enough from the gate so
that the user is prevented
from coming in contact with
the gate while operating the
controls. Outdoor or easily
accessible controls should
have a security feature to
prevent unauthorized use.
Telephone Entry
“Optional” REVERSE GATE
for Closing Direction
Photo Sensors
Note: After a DIP-switch setting is changed, power must be turned
OFF and then turned back on for the new setting to take affect.
Functions ONLY during gate closing cycle.
Key Switch
#1-Com
#2-Fully opens gate.
Safety Opening Device
#1-Com
#2 or #5-Relay
#3-24 volt
250 mamp. max.
3-Wire Radio Receiver
#1-24 Volt Power Com
#1-Relay Com
#2 or #5-Relay
#3-24 Volt Power
4-Wire Radio Receiver
ON
ON
7
Green Close
1 2 3 4 5 6 7 8
Full Open Input
Jumper Wire
Needed
See Manual
Red Full Open
Note: All stand-alone and
telephone entry devices must
use a separate power source.
ON
3
Exit Loop Port
Output
OFF Auto-close timer is OFF. Manual input required to close gate.
ON Auto-close timer is ON. Adjustable from 1-23 seconds to close gate.
OFF The output wired to terminal #4 becomes the output from the loop detector
installed in the EXIT loop port. Plug-in loop detector required for “OFF” function.
ON Normal Setting. Terminal #4 is a normal full open input for a single gate operator.
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Upside-Down on Circuit Board.
Auto-Close
Timer
#4 - Full Open
SW 1
2
#5 - Partial Open (See manual)
Factory Set Configuration
2 1
SW 1 is Upside-Down on Board
SW 1, switch 7: After photo sensor beam
gets obstructed:
OFF Setting - REVERSES GATE.
ON Setting - Stops gate then continues
closing when gate is clear (Same function
as UL 325 terminal #2).
Note: The ON setting is used to help
prevent tailgating but the photo sensor
should be wired to the UL 325 terminal #2
when the “stop gate” function is desired,
see manual for more information.
SW 2 - Left 4 Switches
Description
Normal Setting. Normal gate operation.
Self-test mode. Operator MUST be disconnected from gate to run self-test.
Normal Setting. Normal gate operation.
MUST be ON if gate opens UPHILL.
Normal Setting. Normal gate operation.
MUST be ON if gate opens DOWNHILL.
OFF Leave in the OFF position.
Stand-Alone
Keypad
Com
Stand-Alone
Card Reader
To #4 or #5
#5 Terminal Note: Any opening
device connected to terminal #5 will
open the gate to the partial open
setting. Secondary entrapment
protection devices will also open the
gate to the partial open setting. If the
Inherent Reverse Sensor gets
activated during the close cycle, it
will always fully open the gate.