What is Zetco Press-fit? Zetco Press-fit is a range of ball valves, designed and manufactured with a built-in press connection. This means fewer joints, less mess and major savings with reduced installation time. The integral connection eliminates the use of additional fittings which means fewer leak points for every valve. The range is manufactured under Zetco’s high standards in Italy. Rigorous design and testing has taken place to ensure that Zetco’s premium quality is evident in this new range. See the full range on the inside of this flyer. Certification The gas ball valves are certified by the Australian Gas Association (AGA) to AS 4617 and tested to DVGW VP614. The water valves are WaterMarked by Iapmo R&T Oceana to AS 5830.1. The press-fit ends have been tested to AS3688 and the material composition complies with AS2345. What is the Warranty for Zetco Press-fit? AGA 5301 AGA 5301 AS 4617 AS 4617 IAPMO WM-000110 AS 5830.1 STEP 1 Refer to the design guidelines overleaf for important dimensions which must be considered prior to installation. Use only Type A & B copper pipe complying with AS 1432. Cut the copper pipe to the required length. STEP 2 Carefully deburr the end of the pipe; - INSIDE to minimise turbulence and pressure loss, and - OUTSIDE to avoid damage to the o-ring during insertion. For existing installations, ensure that the copper pipe complies with AS 1432 and is free of defects and in good condition. 25 23 32 25 40 31 A Nom. Size mm DN15 DN20 DN25 DN32 DN40 DN50 Measure and mark the correct insertion depth on the copper pipe. 20 22 50 39 0 mm 10 20 30 40 50 60 70 80 90 100 110 12 STEP 4 Ensure that you are using the correct valve or fitting for your application (water or gas) and the o-rings are correctly positioned. B D Zetco Press-fit must be installed according to the installation instructions provided with every valve and also available on our website. Pipe OD mm 12.70 19.05 25.40 31.75 38.10 50.80 E A mm 17 22 23 25 31 39 B mm 10 10 10 20 20 20 C mm 50 60 62 76 88 110 D mm 60 60 60 60 60 60 Size (mm) Min. Clearance WATER APPLICATIONS Medium Potable water Max. Temp. 110°C Max. Pressure 2500 kPa GAS APPLICATIONS Medium NG, LPG Max. Temp. 100°C Max. Pressure 2100 kPa* *According to AS 5601 Table 4.1, operating pressure of consumer gas piping systems containing copper tube is limited to 200 kPa. Disclaimer: Zetco Valves Pty Ltd will not accept responsibility for damage caused by failure to follow the instructions & warnings provided. © 06-2014 Rest the raised bump in the groove of the press tool and operate press tool according to manufacturer’s instructions. Inspect joint. 15 350 20 500 25 650 32 800 Unpressed connections may not be detected during post-installation pressure testing due to a temporary sealing effect of the o-rings. To ensure that correct sealing has been achieved, visually inspect every joint WARNING to ensure that each one is pressed correctly. 40 1000 Available for gas and water 50 1300 The most recent version of this information sheet, plus additional technical information can be accessed at the Zetco website: www.zetco.com.au Disclaimer: Zetco Valves Pty Ltd will not accept responsibility for damage caused by failure to follow the instructions & warnings provided. Press x press, press x female, press x male Also available in nut & tail which includes Zetco’s continuous flow hot water kits For full details visit zetco.com.au Phone 1300 659 639 Be Impressed with Zetco Full range 15-50mm E mm 80 85 86 88 94 106 Brazing or soldering close to press joints may result in damage to the o-rings. The table below shows the minimum distance required between a press joint and any brazing activity. In cases where this distance cannot be achieved, ensure that the valve or fitting is adequately protected from heat and kept cool during the brazing procedure. STEP 5 Push the valve or fitting onto the copper pipe up to the insertion depth. Recheck engagement with the pipe prior to pressing. NOT SUITABLE FOR Solar hot water systems, medical gases, refrigeration and airconditioning gases, acetylene, urea solution, glycerin triacetate, coolant inhibitor, sodium hydroxide or ammoniac gases. Zetco Installation Instructions BRAZING & SOLDERING Check that the ends are completely free of swarf, sharp metal or other debris which may cause damage the o-rings. WARNING DO NOT USE MINERAL OIL TO LUBRICATE THE O-RINGS AGA 5301 AGA 5301 AS 4617 AS 4617 The table below shows the minimum distances required between a press joint and other objects. Clean the end of the pipe with emery paper or a soft scourer. 15 17 IAPMO WM-000110 AS 5830.1 SPACE REQUIREMENTS C STEP 3 Size (mm) Depth (mm) Press-fit Information For use with Viega®, Rothenberger®, KemPress® V-profile tools only INSTALLATION DESIGN INFORMATION Follow carefully to avoid damage © 06-2014 IMPORTANT INSTALLATION INSTRUCTIONS Follow each step carefully DESIGN GUIDE Press-fit Information For use with Viega®, Rothenberger®, KemPress® V-profile tools only INSTALLATION INSTRUCTION SHEET Zetco Valves warrants that the joint pressed by a Viega®, Rothenberger® or KemPress® V-Profile tool will not leak for a minimum period of 25 years provided it is installed according to the installation instructions provided with every valve and also available on the Zetco website. For our detailed warranty document contact Zetco. Email [email protected] (Aust Pat No 2006 200 845 & Pat Appln No 2013 242 783) www.zetco.com.au November 2014 Phone 1300 659 639 Email [email protected] www.zetco.com.au ZETCO PRESS-FIT WATER BALL VALVES DESCRIPTION Water PxP Lever Handle Water PxP T Handle Water PxM Lever Handle Water PxM T Handle Water PxF Lever Handle Water PxF T Handle Water PxP Lever Lockable Water PxM Lever Lockable Water PxF Lever Lockable Water PxP Lever Extension SIZE PACK IAPMO WM-000110 AS 5830.1 DESCRIPTION SIZE CODE PACK Gas PxP Lever Handle 15 6200015 15 15 6100015 15 20 6100020 10 20 6200020 10 25 6100025 6 25 6200025 6 32 6100032 4 32 6200032 4 40 6100040 2 40 6200040 2 50 6100050 1 50 6200050 1 15 6103015 15 15 6203015 15 20 6103020 10 20 6203020 10 25 6103025 6 25 6203025 6 15 6102015 15 15 6202015 15 20 6102020 10 20 6202020 10 15 6105015 15 15 6205015 15 20 6105020 10 20 6205020 10 15 6101015 15 15 6201015 15 20 6101020 10 20 6201020 10 15 6104015 15 15 6204015 15 20 6104020 10 20 6204020 10 15 6107015 1 20 6107020 1 25 6107025 1 32 6107032 1 40 6107040 1 DESCRIPTION SIZE CODE PACK 50 6107050 1 Water nut & tail 15MM 6301001 10 15X20MM 6301002 10 Gas PxP T Handle Gas PxM Lever Handle Gas PxM T Handle Gas PxF Lever Handle Gas PxF T Handle 15 6109015 1 20 6109020 1 Water nut & tail 20MM 6301003 10 Gas nut & tail 15MM 6302001 10 Gas nut & tail 15X20MM 6302002 10 Gas nut & tail 20MM 6302003 10 15 6108015 1 20 6108020 1 15 6110015 1 20 6110020 1 25 6110025 1 32 6110032 50 6110040 6110050 Tested to DVGW VP614 AGA 5301 AS 4617 ZETCO PRESS-FIT NUT & TAIL BALL VALVES Water nut & tail 40 Note: P = Press-fit M = Male F = Female CODE ZETCO PRESS-FIT GAS BALL VALVES ZETCO PRESS-FIT HOT WATER KITS 1 DESCRIPTION SIZE CODE PACK 1 Kit 1 20G, 20W 6310001 6 1 Kit 2 20G, 15X20W 6310002 6 Kit 3 20G, 15W 6310003 6 Kit 4 15G, 15W 6310004 6 Kit 5 15X20G, 15X20W 6310005 6 Kit 6 15X20G, 15W 6310006 6 Note: Kits include a gas nut & tail valve, a water nut & tail valve and a water outlet fitting. November 2014
© Copyright 2024