Product note Kabeldon cable termination for GIS and TRF, 420 kV APEGA 420 Cable termination suitable as a fixed connection point in a gas-insulated switchgear, a transformer without a separate cable box or where the cable box is filled with transformer oil. Designed to meet the requirements of internationally accepted standards. 1. Top fitting Made of brass. 2. Conductor connection Silver-plated brass connector. 3. Insulator Made of epoxy with an integrated screen interruption. 4. Filling compound Polybuthene oil, volume: 30 liters (expansion vessel included). 5. Stress relief cone Premolded stress relief cone designed for geometric field control. 6. Pressure ring Made of aluminium alloy (bolts are not included). 7. Flange Made of aluminium alloy. 8. Box body Made of aluminium alloy. 2 1 3 4 5 6 7 8 9 10 11 9. Earth clamp The earthing clamp is made of tin-plated brass and clamped with stainless steel bolts. The earth clamp has a rated cross section of 1050 mm². 10. Cable clamp Made of aluminium alloy. The clamp secures the cable in a fixed position. 11. Corona shield Corona shield for transformer (TRF) applications, made of aluminium with surface insulation coating. Main technical data Electrical data, IEC standard 60840 Highest voltage for equipment, Um Rated voltage, U Value of U0 for determination of test voltage Heating cycle voltage test, 2U0 Partial discharge test <5pC, 1.5U0 Switching impulse voltage test Lighting impulse voltage test, BIL AC voltage test, 2 U0 Voltage kV 420 380-400 220 440 330 + 1050 + 1425 440 Dimensions in mm 160 Ø 535 Ø 18 (20x) 1400 Ø 570 Pressure ring. Laboratory for product testing. APEGA installation. Ø 690 ~775 Ø 640 Ø 18 (20x) For GIS. For TRF. Ø 448 AF 420 Adapter flange. CBT 420 Contact bolt for installation of APEGA 420 in transformers. CST 420 Corona shield for TRF installation. Common specifications Classifications Net weight, complete termination, kg GIS/TRF ~ 340 Rated frequency, Hz Max inclination, degrees 50/60 No limitations Dimensions according to IEC 62271-209 GIS Dimensions according to EN 50299 TRF RE-APEGA Re-assembly kit. Stress cone is included. Top bolt must be ordered separately. OKT Kit for optical fibers in screen. Cable range Prepared insulation Ø (mm) Conductor Cu/Al (mm²) 82–120 240–3000 Oversheath Ø (mm) 160 Packaging Net weight Gross weight Dimensions kg kg mm Box 1, termination parts 60 80 120 / 80 / 80 Routine test Epoxy insulator according to EN 50089 Filling compound: Box 2, termination parts 110 130 120 x 80 x 73 Box 3, insulator 191 175 x 66 x 75 170 Dimensions and weights may vary as products occasionally have different packaging. - Dielectric strength according to IEC 60156 - Water content test according to Karl Fischer method Leakage test on flange Visual inspection is performed on all parts of the termination Stress relief cone routine tested according to IEC 62067 - Partial discharge measurement, <5pC, at 1.5 U0 - AC voltage withstand test, 2U0 for 1 h 420 kV 330 kV 440 kV Storage When stored in original, unopened packaging at temperatures in the range of -30°C to 30°C: − The stress relief cone has a shelf life of ten years from date of manufacture. − Tapes and grease have a shelf life of five years. − Metal hardwares have no shelf life limit. The insulating oil shall be stored in original, unopened packaging at temperatures in the range of 5°C to 45°C. The shelf life is ten years from date of manufacture. Optional equipment Connection bolt for TRF installation Corona shield for TRF installation Re-assembly kit Opto kit Screen connection kit Earthing kit For additional information, please contact: www.abb.com/cableaccessories © Copyright 2014 ABB. All rights reserved. Specifications subject to change without notice. Designation CBT 420 CST 420 RE-APEGA OKT SCK JSA Document ID: 7ABA102626_REV A Ø 464
© Copyright 2024