Plateletworks POC Platelet Function Results in 2 minutes with a standard cell counter! • Platelet Count • Platelet Inhibition • Platelet Aggregation • CBC Cascade POC System ® Point of Care for Whole Blood Coagulation The Cascade POC analyzer and unique reagent system are useful in monitoring routine anticoagulants and the antithrombotic drugs used to treat angina, MI, stroke, deep venous thrombosis and pulmonary and arterial emboli. A built-in battery pack and QC lockout features make it ideal for use in the ER, cath lab, cardiac surgery, warfarin clinics and physician offices. Cascade POC offers a rapid POC assay for monitoring the anticoagulant effects of warfarin. Testing is fast and easy: 1. Swipe test card through reader. 2. Insert card into analyzer and add sample. 3. View final results in minutes Cascade POC Assays • Efficient pre-surgical screen • Monitor anti-platelet therapies • Determine best use of transfusion resources • Uses traditional ADP and collagen agonists • No specialized training or equipment • Use whole blood at the point of care Actalyke POC Heparin Assessment Activated Clotting Time • 2-point early clot detection • Single and dual well models • Extensive data handling • Celite, Kaolin, Glass or MAX-ACT tests • PT with INR (ISI ~ 1.0) – PT-WB for fresh whole blood – PT-C for citrated whole blood or plasma 800-231-5663 • www.helena.com • aPTT for citrated whole blood or plasma • c-ACT for fresh whole blood Book M 8/11(4) Helena Hemostasis Helena Hemostasis Prothrombin Time Platelet Aggregation Studies Helena Thromboplastins offer a range of ISI values to provide a reagent that’s just right for your lab. Reagents are prepared from rabbit brain tissue and are suitable for automated, semi-automated and manual applications. Platelet aggregation is performed to identify abnormal platelet function, to quantitate platelet response, and to monitor platelet inhibition by drug therapy. Helena’s platelet reagents provide outstanding stability and reasonable pricing. Reagents are optimized for use with Helena’s AggRAM, but may be used on any turbidometric aggregometer of similar quality. Thromboplastin-LI • Ready for use; no mixing required • Stability of open reagent: 14 days at 2-8°C • Target ISI value: < 1.5 Thromboplastin-MI • Convenient add-a-vial diluent included in kit to eliminate pipetting errors and water problems • Reconstituted stability: 7 days at 2-6°C • Target ISI value: 1.6 to 1.8 Thromboplastin • Reconstituted stability: 7 days at 2-6°C • Target ISI value: 2.0 to 2.5 5248Thromboplastin-LI, 250 tests, 10 x 5 mL 5249Thromboplastin-LI, 500 tests, 10 x 10 mL 5274 Thromboplastin-MI with Diluent, 125 tests, 5 x 5 mL 5271 Thromboplastin-MI with Diluent, 250 tests, 5 x 10 mL 5272 Thromboplastin-MI with Diluent, 500 tests, 10 x 10 mL 5380 Thromboplastin, 200 tests, 10 x 4 mL 5381 Thromboplastin, 500 tests, 10 x 10 mL 5364 5366 5367 5368 5369 5199 5365 Arachidonic Acid, 2 x 1 mL ADP, 2 x 1 mL Epinephrine, 2 x 1 mL Collagen, 2 x 1 mL Platelet Aggregation Kit (5366, 5367, 5368) Ristocetin (for RIPA), 10 x 0.5 mL Tris-Buffered Saline, 1 x 125 mL ADP • Lyophilized preparation of adenosine-5-diphosphate • Reconstitutes to a 20 µM stock solution •Stability of stock solution: 1 week at 2-8°C or 3 months at -20°C Collagen Activated Partial Thromboplastin Time Epinephrine • Lyophilized preparation of L-epinephrine bitartrate • Reconstitutes to 300 µM • Stability of stock solution: 1 week at 2-8°C Helena aPTT reagents are ready-to-use liquids for convenience, high quality for precision, and priced for economy. Reagents are suitable for photo-optical, mechanical and manual (tilt tube) methods. • Lyophilized preparation of sodium arachidonate •Useful in evaluating aspirin-induced platelet dysfunction •It has been suggested that this test be performed before other testing to screen for drugs effecting platelet responsiveness Ristocetin • Derived from the actinomycete Nocardia lurida •For use in ristocetin-induced platelet aggregation (RIPA) assays • Concentration post-reconstitution is 15 mg/mL • Reconstituted stability: 4 hours at 15-30°C or 1 month at -20°C Ristocetin Cofactor Assay aPTT-SA (Soluble Activator) The Ristocetin Cofactor assay measures the ability of vWF in the patient’s plasma to agglutinate formalin-fixed (metabolically inactive) platelets in the presence of ristocetin. This assay is more sensitive than RIPA to mild reductions in vWF and more often used to monitor therapy in vWD patients. • Soluble ellagic acid activator • Optical clarity, homogeneous suspension a plus for automated systems • Shorter activation time (~3 minutes vs. 5 minutes) Ristocetin Cofactor Assay 5388 5389 5387 5386 Page 1 • One of the world’s best collagen preparations • Clear stabilized liquid prepared from equine tendon •10 µg/mL concentration Arachidonic Acid aPTT-SA & CaCl2, 250 tests, 5 x 5 mL aPTT-SA & CaCl2, 500 tests, 5 x 10 mL aPTT-SA, 1000 tests, 10 x 10 mL 0.025 M CaCl2, 10 x 10 mL • Kit includes ristocetin (10 mg/mL; 2 x 1.5 mL), formalinized platelets (~200,000/mL; 4 x 5 mL), S.A.R.P. reference plasma (2 x 1 mL), abnormal control (R:Co <50%; 2 x 0.5 mL), and tris-buffered saline (1 x 35 mL) • Items also available separately • Platelets in Cat. No. 5356 show a slower reaction rate than platelets in Cat. No. 5371 5370 5356 5371 5373 5372 5365 Ristocetin Cofactor Kit, 60 tests Lyophilized Platelets, 5 x 10 mL Lyophilized Platelets, 5 x 5 mL Ristocetin Cofactor Abnormal Control, 5 x 0.5 mL Ristocetin (10 mg/mL), 5 x 1.5 mL Tris-Buffered Saline, 1 x 125 mL Page 6 Helena Hemostasis Helena Hemostasis Fibrinogen vWF:Ag, PC & PS ELISA Assays For quantitative assessment of fibrinogen, Helena’s Fibrinogen Assay is well-suited to automated, semiautomated and manual systems. Fibrinogen Assay components are available as a kit and separately. ELISA kits offer sensitive and specific assays with faster turnaround times, greater ease of use, and clearcut standardized results using established reference preparations. Antigen assays employ 6-point reference curves with accurate detection as low as 5% of normal. Fibrinogen •Clauss methodology for quantitation of fibrinogen in acquired and congenital disorders •Uses high thrombin (~100 NIH units/mL) and low fibrinogen (2 to 50 mg/dL) concentrations so that clotting times are dependent on plasma fibrinogen •Not significantly effected by heparin concentrations below 0.6 USP units/mL and FDP below 100 µg/mL von Willebrand Factor Antigen (vWF:Ag) •Total incubation time 40 minutes at room temperature; overall assay time 55 minutes for 96 determinations •Linearity expressed as the coefficient of determination (r2) 0.995; mean accuracy 103.6% Protein S (Free and Total) 5290 vWF:Ag ELISA Kit, 96 determinations 5291 Protein C ELISA Kit, 96 determinations 5292 Protein S ELISA Kit, 96 determinations 5374 Thrombin Reagent, 200 tests, 10 x 2 mL 5375 Owren’s Veronal Buffer, 10 x 25 mL 5379 Fibrinogen Calibrator, 10 x 1 mL The Thrombin Clotting Time, or Thrombin Time (TT), assay is ideal for qualitative assessment of plasma fibrinogen and interfering substances such as FDP and heparin. •Excellent, rapid screening test for qualitative assessment of plasma fibrinogen and interfering substances such as heparin and FDP •Uses a low concentration of heparin (~3 NIH units/mL) with undiluted plasma • Sensitive to fibrinogen levels below 70 mg/dL AggRAM™ 5377 Thrombin Time Reagent, 250 tests, 10 x 5 mL Cascade® M and Cascade® M-4 AggRAM, for platelet aggregation and ristocetin cofactor testing, couples a four-channel analyzer with the power of Window®-based software for unsurpassed testing flexibility. Up to two AggRAM modules can be run on one Remote Analyzer Module computer so you can configure your analyzers to suit you testing needs. Cascade M and Cascade M-4 are manual hemostasis analyzers that are ideal for all routine clotting assays - PTs, aPTTs, thrombins, fibrinogens and factor assays. Operation is simple and economical, with only a 15” x 15” footprint. •Easy-to-use keyboard •On-screen prompts • State-of-the-art optics • On-board quality control registered trademark of Microsoft Corp. Cat. No. 1484 Page 5 Thrombin Reagent 5 x 2 mL, Fibrinogen Calibrator 2 x 1 mL, Owren’s Veronal Buffer 2 x 25 mL Thrombin Clotting Time •Simultaneous measurement of Free and Total by pretreating with PEG •Linearity (r2) 0.985 for Total, 0.992 for Free; mean accuracy 101% for Total, 98% for Free ®Windows Thrombin Clotting Time Protein C •Simple protocol - total incubation time 60 minutes; overall assay time 75 minutes for 96 determinations • Linearity (r2) 0.992; mean accuracy 99.4% 5376 Fibrinogen Assay Kit, 100 tests Cat. No. 1711 Cat. No. 1710 Page 2 Helena Hemostasis Helena Hemostasis Hemostasis Controls and Reference Plasmas Factor Deficient Substrates Our controls and reference plasmas offer a sensible means to monitor accuracy and precision in hemostasis testing. We encourage you to enroll in our free Quality Assurance Review (QAR) service. Quality laboratory testing is essential to diagnosis and treatment. Helena offers quality factor deficient substrates with < 1% residual factor activity. All substrates (except Factor II) are prepared from human congenitally deficient donors. PT, aPTT and Fibrinogen Controls Congenital Factor Deficient Substrates •Norm-Trol 1 is prepared from lyophilized normal human plasma to provide a normal level control for PT, aPTT, and Fibrinogen assays 5191 5192 5193 5194 5195 5196 5197 •Ab-Trol 2 and Ab-Trol 3 are lyophilized absorbed human plasmas which provide moderately elevated and very elevated, respectively, PT and aPTT controls • Reconstituted controls: stable 8 hours at 2 to 6°C Specialty Assayed Controls and Reference Plasma •S.A.R.P. is a highly acclaimed reference plasma standardized to WHO and ISTH. It is prepared from a frozen pool of citrated plasma from healthy donors. The pool is buffered and lyophilized to ensure stability of all plasma constituents. •Our Specialty Assayed Controls are available in two levels: S.A.C.-1 normal and S.A.C.-2 abnormal (<60% of normal) •S.A.R.P. and S.A.C. are assayed for these parameters: PT, aPTT, Fibrinogen, Factors II, V, VII, VIII, IX, X, XI, XII, Protein C, Protein S (free & total), Ristocetin Cofactor, and vWF:Ag Quality Assurance Review (QAR) •We offer QAR, a free computer service for analyzing daily QC data for shifts or trends and establishing mean control values for individual laboratories •QAR allows you to compare your results to other labs using the same reagents, instruments and controls •Retrospective peer reports include precision data on the various instrument-reagent systems being used •Ask to enroll in this free service when placing your order for Norm-Trol 1, Ab-Trol 2, and Ab-Trol 3 5186 5187 5183 5301 5302 5185 Norm-Trol 1, 10 x 1 mL Ab-Trol 2, 10 x 1 mL Ab-Trol 3, 10 x 1 mL S.A.C.-1 (Normal), 10 x 1 mL S.A.C.-2 (Abnormal), 10 x 1 mL S.A.R.P., 10 x 1 mL Factor V Deficient Substrate, 10 x 1 mL Factor VII Deficient Substrate, 10 x 1 mL Factor VIII Deficient Substrate, 10 x 1 mL Factor IX Deficient Substrate, 10 x 1 mL Factor X Deficient Substrate, 10 x 1 mL Factor XI Deficient Substrate, 10 x 1 mL Factor XII Deficient Substrate, 10 x 1 mL Bovine Factor Deficient Substrate Plasma 5190 Factor II Deficient Substrate, 10 x 1 mL Laurell Rocket Electroimmunodiffusion (EID) Complete line of supplies for quantitating vWF:Ag, Protein C, and Protein S (Free and Total) by the Laurell Rocket method, a technique which combines the specificity of immunochemistry with the ease of electrophoresis. von Willebrand Factor Antigen (vWF:Ag), Protein C and Protein S • Crisp, easy-to-read, well-defined precipitin rockets •All Helena rocket assays use same equipment and technique for ease and convenience •Components available separately for greater economy • Easy, accurate, specific antigen measurement •Free Protein S can be assayed on the same plate as total Protein S by treating the sample with Free Protein S reagent Page 3 5361 5016 5357 5359 5363 5358 5362 vWF:Ag Rocket Plates, 5 x 10 wells/plate Electra B1 Buffer (for vWF:Ag), 10 x 14.1 g Protein C Rocket Plates, 5 x 12 wells/plate Protein S Rocket Plates, 5 x 12 wells/plate Free Protein S Reagent, 5 x 2 mL Tris-Tricine Buffer (for Proteins C & S), 10 x 14.1 g Rocket Stain, 1 x 0.9 g Page 4 Helena Hemostasis Helena Hemostasis Hemostasis Controls and Reference Plasmas Factor Deficient Substrates Our controls and reference plasmas offer a sensible means to monitor accuracy and precision in hemostasis testing. We encourage you to enroll in our free Quality Assurance Review (QAR) service. Quality laboratory testing is essential to diagnosis and treatment. Helena offers quality factor deficient substrates with < 1% residual factor activity. All substrates (except Factor II) are prepared from human congenitally deficient donors. PT, aPTT and Fibrinogen Controls Congenital Factor Deficient Substrates •Norm-Trol 1 is prepared from lyophilized normal human plasma to provide a normal level control for PT, aPTT, and Fibrinogen assays 5191 5192 5193 5194 5195 5196 5197 •Ab-Trol 2 and Ab-Trol 3 are lyophilized absorbed human plasmas which provide moderately elevated and very elevated, respectively, PT and aPTT controls • Reconstituted controls: stable 8 hours at 2 to 6°C Specialty Assayed Controls and Reference Plasma •S.A.R.P. is a highly acclaimed reference plasma standardized to WHO and ISTH. It is prepared from a frozen pool of citrated plasma from healthy donors. The pool is buffered and lyophilized to ensure stability of all plasma constituents. •Our Specialty Assayed Controls are available in two levels: S.A.C.-1 normal and S.A.C.-2 abnormal (<60% of normal) •S.A.R.P. and S.A.C. are assayed for these parameters: PT, aPTT, Fibrinogen, Factors II, V, VII, VIII, IX, X, XI, XII, Protein C, Protein S (free & total), Ristocetin Cofactor, and vWF:Ag Quality Assurance Review (QAR) •We offer QAR, a free computer service for analyzing daily QC data for shifts or trends and establishing mean control values for individual laboratories •QAR allows you to compare your results to other labs using the same reagents, instruments and controls •Retrospective peer reports include precision data on the various instrument-reagent systems being used •Ask to enroll in this free service when placing your order for Norm-Trol 1, Ab-Trol 2, and Ab-Trol 3 5186 5187 5183 5301 5302 5185 Norm-Trol 1, 10 x 1 mL Ab-Trol 2, 10 x 1 mL Ab-Trol 3, 10 x 1 mL S.A.C.-1 (Normal), 10 x 1 mL S.A.C.-2 (Abnormal), 10 x 1 mL S.A.R.P., 10 x 1 mL Factor V Deficient Substrate, 10 x 1 mL Factor VII Deficient Substrate, 10 x 1 mL Factor VIII Deficient Substrate, 10 x 1 mL Factor IX Deficient Substrate, 10 x 1 mL Factor X Deficient Substrate, 10 x 1 mL Factor XI Deficient Substrate, 10 x 1 mL Factor XII Deficient Substrate, 10 x 1 mL Bovine Factor Deficient Substrate Plasma 5190 Factor II Deficient Substrate, 10 x 1 mL Laurell Rocket Electroimmunodiffusion (EID) Complete line of supplies for quantitating vWF:Ag, Protein C, and Protein S (Free and Total) by the Laurell Rocket method, a technique which combines the specificity of immunochemistry with the ease of electrophoresis. von Willebrand Factor Antigen (vWF:Ag), Protein C and Protein S • Crisp, easy-to-read, well-defined precipitin rockets •All Helena rocket assays use same equipment and technique for ease and convenience •Components available separately for greater economy • Easy, accurate, specific antigen measurement •Free Protein S can be assayed on the same plate as total Protein S by treating the sample with Free Protein S reagent Page 3 5361 5016 5357 5359 5363 5358 5362 vWF:Ag Rocket Plates, 5 x 10 wells/plate Electra B1 Buffer (for vWF:Ag), 10 x 14.1 g Protein C Rocket Plates, 5 x 12 wells/plate Protein S Rocket Plates, 5 x 12 wells/plate Free Protein S Reagent, 5 x 2 mL Tris-Tricine Buffer (for Proteins C & S), 10 x 14.1 g Rocket Stain, 1 x 0.9 g Page 4 Helena Hemostasis Helena Hemostasis Fibrinogen vWF:Ag, PC & PS ELISA Assays For quantitative assessment of fibrinogen, Helena’s Fibrinogen Assay is well-suited to automated, semiautomated and manual systems. Fibrinogen Assay components are available as a kit and separately. ELISA kits offer sensitive and specific assays with faster turnaround times, greater ease of use, and clearcut standardized results using established reference preparations. Antigen assays employ 6-point reference curves with accurate detection as low as 5% of normal. Fibrinogen •Clauss methodology for quantitation of fibrinogen in acquired and congenital disorders •Uses high thrombin (~100 NIH units/mL) and low fibrinogen (2 to 50 mg/dL) concentrations so that clotting times are dependent on plasma fibrinogen •Not significantly effected by heparin concentrations below 0.6 USP units/mL and FDP below 100 µg/mL von Willebrand Factor Antigen (vWF:Ag) •Total incubation time 40 minutes at room temperature; overall assay time 55 minutes for 96 determinations •Linearity expressed as the coefficient of determination (r2) 0.995; mean accuracy 103.6% Protein S (Free and Total) 5290 vWF:Ag ELISA Kit, 96 determinations 5291 Protein C ELISA Kit, 96 determinations 5292 Protein S ELISA Kit, 96 determinations 5374 Thrombin Reagent, 200 tests, 10 x 2 mL 5375 Owren’s Veronal Buffer, 10 x 25 mL 5379 Fibrinogen Calibrator, 10 x 1 mL The Thrombin Clotting Time, or Thrombin Time (TT), assay is ideal for qualitative assessment of plasma fibrinogen and interfering substances such as FDP and heparin. •Excellent, rapid screening test for qualitative assessment of plasma fibrinogen and interfering substances such as heparin and FDP •Uses a low concentration of heparin (~3 NIH units/mL) with undiluted plasma • Sensitive to fibrinogen levels below 70 mg/dL AggRAM™ 5377 Thrombin Time Reagent, 250 tests, 10 x 5 mL Cascade® M and Cascade® M-4 AggRAM, for platelet aggregation and ristocetin cofactor testing, couples a four-channel analyzer with the power of Window®-based software for unsurpassed testing flexibility. Up to two AggRAM modules can be run on one Remote Analyzer Module computer so you can configure your analyzers to suit you testing needs. Cascade M and Cascade M-4 are manual hemostasis analyzers that are ideal for all routine clotting assays - PTs, aPTTs, thrombins, fibrinogens and factor assays. Operation is simple and economical, with only a 15” x 15” footprint. •Easy-to-use keyboard •On-screen prompts • State-of-the-art optics • On-board quality control registered trademark of Microsoft Corp. Cat. No. 1484 Page 5 Thrombin Reagent 5 x 2 mL, Fibrinogen Calibrator 2 x 1 mL, Owren’s Veronal Buffer 2 x 25 mL Thrombin Clotting Time •Simultaneous measurement of Free and Total by pretreating with PEG •Linearity (r2) 0.985 for Total, 0.992 for Free; mean accuracy 101% for Total, 98% for Free ®Windows Thrombin Clotting Time Protein C •Simple protocol - total incubation time 60 minutes; overall assay time 75 minutes for 96 determinations • Linearity (r2) 0.992; mean accuracy 99.4% 5376 Fibrinogen Assay Kit, 100 tests Cat. No. 1711 Cat. No. 1710 Page 2 Helena Hemostasis Helena Hemostasis Prothrombin Time Platelet Aggregation Studies Helena Thromboplastins offer a range of ISI values to provide a reagent that’s just right for your lab. Reagents are prepared from rabbit brain tissue and are suitable for automated, semi-automated and manual applications. Platelet aggregation is performed to identify abnormal platelet function, to quantitate platelet response, and to monitor platelet inhibition by drug therapy. Helena’s platelet reagents provide outstanding stability and reasonable pricing. Reagents are optimized for use with Helena’s AggRAM, but may be used on any turbidometric aggregometer of similar quality. Thromboplastin-LI • Ready for use; no mixing required • Stability of open reagent: 14 days at 2-8°C • Target ISI value: < 1.5 Thromboplastin-MI • Convenient add-a-vial diluent included in kit to eliminate pipetting errors and water problems • Reconstituted stability: 7 days at 2-6°C • Target ISI value: 1.6 to 1.8 Thromboplastin • Reconstituted stability: 7 days at 2-6°C • Target ISI value: 2.0 to 2.5 5248Thromboplastin-LI, 250 tests, 10 x 5 mL 5249Thromboplastin-LI, 500 tests, 10 x 10 mL 5274 Thromboplastin-MI with Diluent, 125 tests, 5 x 5 mL 5271 Thromboplastin-MI with Diluent, 250 tests, 5 x 10 mL 5272 Thromboplastin-MI with Diluent, 500 tests, 10 x 10 mL 5380 Thromboplastin, 200 tests, 10 x 4 mL 5381 Thromboplastin, 500 tests, 10 x 10 mL 5364 5366 5367 5368 5369 5199 5365 Arachidonic Acid, 2 x 1 mL ADP, 2 x 1 mL Epinephrine, 2 x 1 mL Collagen, 2 x 1 mL Platelet Aggregation Kit (5366, 5367, 5368) Ristocetin (for RIPA), 10 x 0.5 mL Tris-Buffered Saline, 1 x 125 mL ADP • Lyophilized preparation of adenosine-5-diphosphate • Reconstitutes to a 20 µM stock solution •Stability of stock solution: 1 week at 2-8°C or 3 months at -20°C Collagen Activated Partial Thromboplastin Time Epinephrine • Lyophilized preparation of L-epinephrine bitartrate • Reconstitutes to 300 µM • Stability of stock solution: 1 week at 2-8°C Helena aPTT reagents are ready-to-use liquids for convenience, high quality for precision, and priced for economy. Reagents are suitable for photo-optical, mechanical and manual (tilt tube) methods. • Lyophilized preparation of sodium arachidonate •Useful in evaluating aspirin-induced platelet dysfunction •It has been suggested that this test be performed before other testing to screen for drugs effecting platelet responsiveness Ristocetin • Derived from the actinomycete Nocardia lurida •For use in ristocetin-induced platelet aggregation (RIPA) assays • Concentration post-reconstitution is 15 mg/mL • Reconstituted stability: 4 hours at 15-30°C or 1 month at -20°C Ristocetin Cofactor Assay aPTT-SA (Soluble Activator) The Ristocetin Cofactor assay measures the ability of vWF in the patient’s plasma to agglutinate formalin-fixed (metabolically inactive) platelets in the presence of ristocetin. This assay is more sensitive than RIPA to mild reductions in vWF and more often used to monitor therapy in vWD patients. • Soluble ellagic acid activator • Optical clarity, homogeneous suspension a plus for automated systems • Shorter activation time (~3 minutes vs. 5 minutes) Ristocetin Cofactor Assay 5388 5389 5387 5386 Page 1 • One of the world’s best collagen preparations • Clear stabilized liquid prepared from equine tendon •10 µg/mL concentration Arachidonic Acid aPTT-SA & CaCl2, 250 tests, 5 x 5 mL aPTT-SA & CaCl2, 500 tests, 5 x 10 mL aPTT-SA, 1000 tests, 10 x 10 mL 0.025 M CaCl2, 10 x 10 mL • Kit includes ristocetin (10 mg/mL; 2 x 1.5 mL), formalinized platelets (~200,000/mL; 4 x 5 mL), S.A.R.P. reference plasma (2 x 1 mL), abnormal control (R:Co <50%; 2 x 0.5 mL), and tris-buffered saline (1 x 35 mL) • Items also available separately • Platelets in Cat. No. 5356 show a slower reaction rate than platelets in Cat. No. 5371 5370 5356 5371 5373 5372 5365 Ristocetin Cofactor Kit, 60 tests Lyophilized Platelets, 5 x 10 mL Lyophilized Platelets, 5 x 5 mL Ristocetin Cofactor Abnormal Control, 5 x 0.5 mL Ristocetin (10 mg/mL), 5 x 1.5 mL Tris-Buffered Saline, 1 x 125 mL Page 6 Plateletworks POC Platelet Function Results in 2 minutes with a standard cell counter! • Platelet Count • Platelet Inhibition • Platelet Aggregation • CBC Cascade POC System ® Point of Care for Whole Blood Coagulation The Cascade POC analyzer and unique reagent system are useful in monitoring routine anticoagulants and the antithrombotic drugs used to treat angina, MI, stroke, deep venous thrombosis and pulmonary and arterial emboli. A built-in battery pack and QC lockout features make it ideal for use in the ER, cath lab, cardiac surgery, warfarin clinics and physician offices. Cascade POC offers a rapid POC assay for monitoring the anticoagulant effects of warfarin. Testing is fast and easy: 1. Swipe test card through reader. 2. Insert card into analyzer and add sample. 3. View final results in minutes Cascade POC Assays • Efficient pre-surgical screen • Monitor anti-platelet therapies • Determine best use of transfusion resources • Uses traditional ADP and collagen agonists • No specialized training or equipment • Use whole blood at the point of care Actalyke POC Heparin Assessment Activated Clotting Time • 2-point early clot detection • Single and dual well models • Extensive data handling • Celite, Kaolin, Glass or MAX-ACT tests • PT with INR (ISI ~ 1.0) – PT-WB for fresh whole blood – PT-C for citrated whole blood or plasma 800-231-5663 • www.helena.com • aPTT for citrated whole blood or plasma • c-ACT for fresh whole blood Book M 8/11(4)
© Copyright 2024