Manifold for central heating system 550 series 01261/14 GB ACCREDITED ISO 9001 ISO 9001 No. 0003 FM 21654 Function The manifolds for central heating system are used in heating and air-conditioning systems to allow different heat adjustments of the various rooms when there is only one heat generator or chiller. The various configurations are compact and can be easily fitted in any kind of hydraulic circuit, with the advantages of ease of installation and saving of useful living space. The manifolds for central heating systems can be equipped, as an accessory, with pre-formed shell insulation to ensure perfect thermal insulation in both heating and air-conditioning systems. Product range manifold manifold manifold manifold manifold for for for for for central central central central central heating heating heating heating heating system system system system system 2 3 4 2+1 3+1 size size size size size Materials Body: Maximum working pressure: Working temperature range: outlet: outlet: outlet: outlet: outlet: 1 1 1 1 1 1/2” 1/2” 1/2” 1/2” 1/2” with with with with with nut nut nut nut nut (centre (centre (centre (centre (centre distance distance distance distance distance 125 125 125 125 125 mm) mm) mm) mm) mm) Manifold inner diameter: - 2 and 2+1: - 3, 3+1 and 4: Øi 53 mm Øi 69 mm water and non-hazardous glycol solutions excluded from the range of application of Directive 67/548/EC ∆ ∆p p (mm w.g.) 400 4 300 3 200 180 Material: closed cell expanded PEX Thickness: 20 mm Density: - inner part: 30 kg/m3 - outer part: 50 kg/m3 Thermal conductivity (DIN 52612): - at 0°C 0,038 W/(m·K) - at 40°C 0,045 W/(m·K) Coefficient of resistance to water vapour diffusion (DIN 52615): > 1300 Working temperature range: 0–100°C Reaction to fire (DIN 4102): class B2 100 0,03 , 1,8 1,6 1 ,6 1,4 1,4 1,2 1 2 0,018 , 0 016 0, 0,016 0,014 0,014 0 012 0,012 5 2 1 0,5 0,2 0,1 0,05 0,02 0,01 4 3,5 0,04 3 3 4 2,5 0,18 , 0 16 0,16 0 14 0,14 0,12 0,09 , 0,08 0,08 0,07 0 07 0,06 1,8 18 16 4 14 12 9 8 7 6 1,6 0,3 2 1 0,4 30 1,4 2 40 1,2 5 1,8 , 1,6 1,6 1,4 1,4 1,2 12 0,9 0,8 0,8 0,7 07 0,6 0,9 10 10 160 140 120 90 80 70 60 1 20 ∆p ∆p (kPa) 550030/31/40 550030/31/40 9 8 7 6 Technical specifications of insulation (optional) 50 550 550020 020 0,8 500 550021 550021 900 800 700 600 0,7 1000 0,6 120 mm 125 mm 0,45 - main: - outlets: 6p 6p 0,5 2 and 2+1: 1 1/4” M 3, 4 and 3+1: 1 1/2” M 1 1/2” with nut M8x1,25 0,40 - main: - outlets: - fitted for brackets: Centre distance: 1/4”; 1/2”; 1/2”; 1/4”; 1/2”; 0,35 Connections: painted steel 10 bar 5–110°C 0,30 Medium: 1 1 1 1 1 Hydraulic characteristics Technical specifications 0,25 550020 550030 550040 550021 550031 0,20 Code Code Code Code Code G (m3/h) Dimensions Installation 38832 The 550 series manifolds are equipped with outlets with a captive nut. The manifolds must be installed by paying attention to the connection of the flow and return pipes, both for the main connections and for the outlets, in accordance with the label affixed to the body. Code Mass (kg) 550020 6,1 Series 550 Pmax 10 bar Trange 5÷110°C The 550 series manifolds can be installed horizontally and even upside down. They can also be installed vertically, but with the main connections turned upward in order to prevent air pockets forming in the top. Code Mass (kg) 550021 6,5 Code Mass (kg) 550030 11,3 Code Mass (kg) 550031 11,7 Fitted for wall mounting The 550 series manifolds are equipped with M8 nuts for wall mounting (brackets, wall anchors, nuts and bolts are not supplied in the package). Volumes Code Mass (kg) 550040 14,9 Code Volume (litres) 550020 2,5 550021 2,6 550030 6,0 550031 6,1 550040 7,9 559 Accessories Pair of plugs with seal for not used outlets. Insulation for manifolds for central heating systems 550 series. For heating and air-conditioning systems. Code 559001 Code CBN550020 CBN550021 CBN550030 CBN550031 CBN550040 for manifold 2 for manifold 2+1 for manifold 3 for manifold 3+1 for manifold 4 Application diagrams Chrono-thermostat System with floor-standing boiler and manifold 3+1 Pump Shut-off valve Thermostat T Digital regulator Thermostatic valve Outside probe 13 167 series Open B AUTO MAN 230 V ˜ ±10% 6 VA Amb. temp. range -10–55°C Opening/closing time 50 s 90° rotation IP 65 Open A Code 167022 T SPECIFICATION SUMMARY Code 550020 Manifold for central heating systems, 2 outlets. Painted steel body. Connections to generator 1 1/4” M, centre distance 120 mm. Outlet connections 1 1/2” with nut, two at the top, centre distance 125 mm. Medium water and glycol solutions, maximum percentage of glycol 30%. Maximum working pressure 10 bar. Working temperature range 5–110°C (0–100°C with insulation). Fitted for mounting with M8x1,25 nuts. Code 550030 Manifold for central heating systems, 3 outlets. Painted steel body. Connections to generator 1 1/2” M, centre distance 120 mm. Outlet connections 1 1/2” with nut, three at the top, centre distance 125 mm. Medium water and glycol solutions, maximum percentage of glycol 30%. Maximum working pressure 10 bar. Working temperature range 5–110°C (0–100°C with insulation). Fitted for mounting with M8x1,25 nuts. Code 550040 Manifold for central heating systems, 4 outlets. Painted steel body. Connections to generator 1 1/2” M, centre distance 120 mm. Outlet connections 1 1/2” with nut, four at the top, centre distance 125 mm. Medium water and glycol solutions, maximum percentage of glycol 30%. Maximum working pressure 10 bar. Working temperature range 5–110°C (0–100°C with insulation). Fitted for mounting with M8x1,25 nuts. Code 550021 Manifold for central heating systems, 2+1 outlets. Painted steel body. Connections to generator 1 1/4” M, centre distance 120 mm. Outlet connections 1 1/2” with nut, two at the top and one at the bottom, centre distance 125 mm. Medium water and glycol solutions, maximum percentage of glycol 30%. Maximum working pressure 10 bar. Working temperature range 5–110°C (0–100°C with insulation). Fitted for mounting with M8x1,25 nuts. Code 550031 Manifold for central heating systems, 3+1 outlets. Painted steel body. Connections to generator 1 1/2” M, centre distance 120 mm. Outlet connections 1 1/2” with nut, three at the top and one at the bottom, centre distance 125 mm. Medium water and glycol solutions, maximum percentage of glycol 30%. Maximum working pressure 10 bar. Working temperature range 5–110°C (0–100°C with insulation). Fitted for mounting with M8x1,25 nuts. Code CBN5500.. Optional insulation for 550 series manifolds for central heating systems. Material closed cell expanded PEX. For heating and air-conditioning systems. Code 559001 Pair of plugs with seal for not used outlets. Size 1 1/2” M. We reserve the right to make changes and improvements to our products and the related technical data in this publication, at any time and without prior notice. Caleffi S.p.A. S.R. 229 n. 25 · 28010 Fontaneto d’Agogna (NO) · Italy Tel. +39 0322 8491 · Fax +39 0322 863723 [email protected] · www.caleffi.com © Copyright 2014 Caleffi
© Copyright 2024