Commercial Metering Switchboards Meter Sections General Type SMM / SMD — For EUSERC Utility Area Installations Type SMM Service Multi-Metering switchboards are specifically designed with built-in flexibility for all types of multi-metering commercial and industrial applications. Features 쐍 4000 Amperes Main Service 480 Volt Maximum 쐍 200 Ampere Continuous Duty Metering Sockets 쐍 With Test Blocks 쐍 Meets EUSERC Requirements 쐍 UL Listed and Labeled 쐍 Hot Sequence Metering Standard 쐍 All Meter Sockets Are Prewired 쐍 Copper or Aluminum Bus 쐍 65,000A Sym Bracing Standard (Higher Bracing Available if Required) 쐍 Type 3R Construction Available 쐍 Available With Corner Sections 쐍 Meets PB2 Standards 쐍 Rear Cable Barrier Available for Top Load Cable Exit 8 Commercial Metering Switchboards Type MMS Features 쐍 Up to 4000A Main Service, 120 / 240V, 240V, 208Y / 120V, 480Y / 277V, 480V, 1쏗3W, 3쏗3W, 3쏗4W 쐍 100A or 200A Tenant Mains are Interchangeable 쐍 UL Listed and Labeled 쐍 Hot Sequence Metering is Standard; Cold Sequence also Available 쐍 50,000A Symmetrical Bus Bracing (higher available if required) 쐍 All Meter Sockets are Pre-Wired for 100A or 200A Devices CSI Section 16470 쐍 쐍 쐍 쐍 쐍 쐍 쐍 Copper or Aluminum Bus Available All Units Front Accessible Type 3R Construction Available Available with Cable Pull Sections and Corner Sections Sockets are 200A Rated with Lever Type Manual Bypass Load Cable Exit Top or Bottom Common Depth for Main and Metering Sections upon Request Siemens Electrical Products and Systems Specification Guide 145 Commercial Metering Switchboards Meter Sections General Type SMM / SMD — For EUSERC Utility Area Installations Type SMM Service Multi-Metering switchboards are specifically designed with built-in flexibility for all types of multi-metering commercial and industrial applications. Features 쐍 4000 Amperes Main Service 480 Volt Maximum 쐍 200 Ampere Continuous Duty Metering Sockets 쐍 With Test Blocks 쐍 Meets EUSERC Requirements 쐍 UL Listed and Labeled 쐍 Hot Sequence Metering Standard 쐍 All Meter Sockets Are Prewired 쐍 Copper or Aluminum Bus 쐍 65,000A Sym Bracing Standard (Higher Bracing Available if Required) 쐍 Type 3R Construction Available 쐍 Available With Corner Sections 쐍 Meets PB2 Standards 쐍 Rear Cable Barrier Available for Top Load Cable Exit 8 Commercial Metering Switchboards Type MMS Features 쐍 Up to 4000A Main Service, 120 / 240V, 240V, 208Y / 120V, 480Y / 277V, 480V, 1쏗3W, 3쏗3W, 3쏗4W 쐍 100A or 200A Tenant Mains are Interchangeable 쐍 UL Listed and Labeled 쐍 Hot Sequence Metering is Standard; Cold Sequence also Available 쐍 50,000A Symmetrical Bus Bracing (higher available if required) 쐍 All Meter Sockets are Pre-Wired for 100A or 200A Devices CSI Section 16470 쐍 쐍 쐍 쐍 쐍 쐍 쐍 Copper or Aluminum Bus Available All Units Front Accessible Type 3R Construction Available Available with Cable Pull Sections and Corner Sections Sockets are 200A Rated with Lever Type Manual Bypass Load Cable Exit Top or Bottom Common Depth for Main and Metering Sections upon Request Siemens Electrical Products and Systems Specification Guide 145 Commercial Metering Switchboards Meter Sections General Type SMM / SMD — For EUSERC Utility Area Installations Table 8.1 — Type SMM/SMD Meter Sections Checklist Cabling Protective Device T-Fuse Pullout Circuit Breaker Service Sockets Fusible Switches Top Load 480 / 277V, 480V, 240, 208Y / 120 3 Phase 3 Wire 3 Phase 4 Wire Available with 200 A sockets, Test Blocks. Wiring for 100 or 200A depending on tenant mains, which are interchangeable with field installation kit (cable not included). — If load cables exit top, a rear load cable barrier or loadside wireway must be added. Vacu-Break 240V 120 / 240V, 480V, 240V, 208Y / 120 1 Phase 3 Wire 3 Phase 3 Wire 3 Phase 4 Wire Vacu-Break 480V 480 / 277V, 480V, 3 Phase 3 Wire 3 Phase 4 Wire 100 and 200A switches are field interchangeable Directly into Metering Section Lugs required. A full-size meter section must be used. A 20 in. (508 mm) high pullbox required for top entry. Bottom entry not available. A 20 in. (508 mm) wide section with incoming lugs requires a pull section. Lugs required. A full-size meter section must be used. A 20 in. (508 mm) top hat or transition section may be required depending upon the direction of the feed and location of load disconnects. Circuit Breaker / T-Fuse Pullout Commercial Metering Switchboards 8 Bottom Load Full-size Section Bottom Load Half Section Vacu-Break Half Section Available in 240V Only Bottom Load Half Section 146 Full Section Available in 480Y Only Bottom Load Full-size Section Siemens Electrical Products and Systems Specification Guide CSI Section 16470 Commercial Metering Switchboards Meter Sections General Type MMS Table 8.2 Type MMS Meter Sections Checklist Protective Device Service 480 / 277V, 480V, T-Fuse Pullout 240, 208Y / 120 3 Phase 3 Wire Circuit Breaker 3 Phase 4 Wire Vacu-Break 240V 120 / 240V, 480V, 240V, 208Y / 120 1 Phase 3 Wire 3 Phase 3 Wire 3 Phase 4 Wire Vacu-Break 480V 480 / 277V, 480V, 3 Phase 3 Wire 3 Phase 4 Wire Sockets Cabling 200A, Includes a manual bypass lever. Wiring for 100 or 200A depending on tenant mains, which are interchangeable with field installation kit (cable not included). When cable is brought directly into meter section, a full-size meter section is required. A 20 in. (508 mm) high top pull box is required for top entry. Bottom entry not available. A transition section may be required depending on direction of feed and location of tenant mains. Circuit Breaker / T-Fuse Pullout 8 Commercial Metering Switchboards Top Load Half Section Bottom Load Full-size Section Vacu-Break Bottom Load 240V Only햲 Half Section 햲 Top Load 240V Only햲 Full-size Section 480V Sections are available. CSI Section 16470 Siemens Electrical Products and Systems Specification Guide 147 Commercial Metering Switchboards Disconnect Ratings Technical Type SMM / SMD and MMS Table 8.5 — Main Vacu-Break® Switches Table 8.3 Main Circuit Breakers Commercial Metering Switchboards 8 Siemens Ampere Breaker Type Rating For SMM JXD2 JXD6 JD6, SJD6 400 HJD6 / SHJD6 — LD6, SLD6 HLD6 / SHLD6 600 LXD6 — MD6 / LMD6 / SMD6 800 HMD6 / HLMD6 / SHMD6 — ND6 / SND6 1000 HND6 / SHND6 ND6, SND6 HND6 / SHND6 1200 — PD6 / SPD6 HPD6 / SHPD6 1600 — RD6 2000 SBS 2500 SBS 3000 For MMS JXD2 JXD6 JD6, SJD6 HJD6 / SHJD6 CJD6, SCJD6 LD6, SLD6 HLD6 / SHLD6 LXD6 CLD6, SCLD6 MD6 / LMD6 / SMD6 HMD6 / HLMD6 / SHMD6 CMD6, SCMD6 ND6 / SND6 HND6 / SHND6 ND6 / SND6 HND6 / SHND6 CND6 / SCND6 PD6 / SPD6 HPD6 / SHPD6 CPD6 RD6 SBS SBS Maximum Interrupting Capacity Symmetrical RMS Amperes 480 V 240 V 65,000 — 65,000 35,000 100,000 200,000 65,000 100,000 65,000 200,000 65,000 100,000 200,000 65,000 100,000 65,000 100,000 200,000 65,000 100,000 200,000 65,000 100,000 100,000 65,000 150,000 35,000 65,000 35,000 150,000 50,000 65,000 100,000 50,000 65,000 50,000 65,000 100,000 50,000 65,000 100,000 50,000 100,000 100,000 Maximum Fuse For Interrupting Capacity Switchboard Symmetrical RMS Amperes Ampere Type Rating SMM MMS 240 Volt 480 Volt R J, R, T 400 100,000 100,000 R J, R, T 600 100,000 100,000 L L 800 100,000 100,000 L L 1200 100,000 100,000 Table 8.6 Branch Vacu-Break® Fusible Switches Maximum Fuse For Interrupting Capacity Switchboard Symmetrical Type RMS Amperes Ampere Rating 480 Volt SMM MMS 240 Volt J J, T 200,000 100,000 100 — R R 100,000 J J, T 200,000 100,000 200 R R 42,000 42,000 Table 8.7 — Main Bolted Pressure Switches Maximum Fuse For Interrupting Capacity Switchboard Symmetrical Type RMS Amperes Ampere Rating SMM MMS 240 Volt 480 Volt L L 800–4000 200,000 200,000 Table 8.4 Tenant Circuit Breakers with Commercial Meter Sockets Maximum Interrupting Capacity Symmetrical RMS Amperes 10,000 22,000 42,000 햲 100A 148 Table 8.8 480 V 240 V Ampere Rating 100 200 Breaker Type햲 2, 3 Pole BQ QJ2 100 BHQ 200 100 200 QJH2 HBQ QJ2-H Maximum Interrupting Capacity Symmetrical RMS Amperes 18,000 30,000 42,000 Ampere Rating 100 200 Breaker Type 햲 2, 3 Pole ED4 FD6 100 HED4 200 100 200 FD6 HHED6 HFD6 and 200A tenant circuit breakers may be specified within same AIC grouping only. Siemens Electrical Products and Systems Specification Guide Fusible Pullouts Maximum Fuse For Interrupting Capacity Switchboard Symmetrical RMS Amperes Ampere Type Rating SMM MMS 240 Volt 480 Volt T T 100 200,000 200,000 T T 200 200,000 200,000 Table 8.9 Main HCP Switches Maximum Fuse For Interrupting Capacity SMM & MMS Symmetrical RMS Amperes Ampere Rating 240V 480V 240 Volt 480 Volt T L 800 200,000 200,000 T L 1200 200,000 200,000 CSI Section 16470 Commercial Metering Switchboards Type SMM / SMD — For EUSERC Utility Area Installations Dimensions Circuit Breaker Main Table 8.11 Table 8.10 Circuit Breaker Main With Underground Pull Section 32 (813) 90 (2286) D2 20 (508) 38 (965) 46 (1168) 11.5 (292) 28 (711) Ampere Rating 400 600 800 1000 1200 1600 2000 2500 3000 Dimensions in Inches (mm) H W D1 90 (2286) 32 (813) D2 20 (508) 11.5 (292) 38 (965) 8 28 (711) Commercial Metering Switchboards Ampere Rating 400 600 800 1000 1200 1600 2000 Dimensions in Inches (mm) H W D1 Circuit Breaker Main Without Pull Section Fusible Switch Main Table 8.13 Vacu-Break and HCP Main Without Pull Section Table 8.12 Vacu-Break and HCP Main With Underground Pull Section Switch Type Vacu Break HCP Ampere Rating 400 600 800 1200 800 1200 CSI Section 16470 Dimensions in Inches (mm) H W D1 32 (813) 90 (2286) 38 (965) D2 20 (508) 28 (711) 20 (508) 11.5 (292) Switch Type Vacu Break HCP Ampere Rating 400 600 800 1200 800 1200 Siemens Electrical Products and Systems Specification Guide Dimensions in Inches (mm) H W D1 32 20 (813) (508) 90 (2286) 38 (965) 28 (711) D2 11.5 (292) 20 (508) 149 Commercial Metering Switchboards Type SMM / SMD — For EUSERC Utility Area Installations Dimensions Bolted Pressure Switch Table 8.15 Table 8.14 Bolted Pressure Switch Main With Underground Pull Section Ampere Rating 800 1200 1600 2000 Commercial Metering Switchboards 8 Dimensions in Inches (mm) H W D1 90 (2286) 38 (965) 46 (1168) Dimensions in Inches (mm) H W D1 Ampere Rating 800 1200 1600 2000 2500 3000 4000 D2 28 (711) Bolted Pressure Switch Without Pull Sections 11.5 (292) 38 (965) 90 (2286) 28 (711) D2 11.5 (292) 46 (1168) 52 (1321) 38 (965) Meter Sections Circuit Breaker and T-Fuse Pullout Table 8.16 Maximum Cross Bus Ampere Rating 800–2500 NEMA 1 Dimensions In Inches (mm) Circuit Breaker with Test Block H 90 (2286) Max. Voltage 480 No. of Sockets 3 6 3 6 W 20 (508) 32 (813) 20 (508) 32 (813) 480V Only Vacu-Break Switches Type SMM / SMD Meter Section Dimensions 3000–4000 햲 240V Only Vacu-Break D 20 (508) 28 (711) Max. Voltage 240 480햲 240 480햲 No. of Sockets 2 6 2 6 W 20 (508) 58 (1473) 20 (508) 58 (1473) D 20 (508) 28 (711) NEMA 3R Dimensions In Inches (mm) W H CB VB 26 (660) 26 (660) 38 (965) 61 (1549) 91 (2311) 26 (660) 26 (660) 38 (965) 61 (1549) D 31.5 (800) 39.5 (1003) Available with or without test blocks. 150 Siemens Electrical Products and Systems Specification Guide CSI Section 16470 Commercial Metering Switchboards Type MMS Dimensions Circuit Breaker and T-Fuse Pullout Sections Top Load Top Load Bottom Load Bottom Load Vacu-Break Sections 8 Commercial Metering Switchboards Top Load 240V Unit Table 8.17 Top Load 240V Unit Top Load 480V Unit Bottom Load 240V Unit Bottom Load 240V Unit Type MMS Meter Section Dimensions Circuit Breaker or T-Fuse Pullout Vacu-Break Dimensions in Inches (mm) Socket Amp Rating 200 Bottom Load 480V Unit Max. Voltage 240 or 480 Load Top Bottom Top Bottom CSI Section 16470 No. of Sockets 2 3 4 6 H 20 (2286) W 20 (508) 32 (813) Dimensions in Inches (mm) D NEMA 1 3R Socket Amp Rating 20 (508) 31 (787) 100 or 200 Max. Voltage 240 Load Top or Bottom 480 Siemens Electrical Products and Systems Specification Guide No. of Sockets 2 4 4 H 90 (2286) W 20 (508) 38 (965) D NEMA 1 3R 20 (508) 31 (787) 46 (1168) 151 Commercial Metering Switchboards Auxiliary Sections Dimensions Types SMM / SMD and MMS D D D Bussed Pull Section Non Bussed Pull Section Transition Section H2 Commercial Metering Switchboards 8 D D Load Side Wireway Top Pull Box Table 8.18 Types SMM/SMD and MMS Auxiliary Sections Dimensions Section Dimensions in Inches (mm) NEMA 1 H Non Bussed Pull Section EUSERC Bussed UGPS W/Utility Studs H1-90 (2286) Bussed Pull Section Transition Section Load Side Wireway Top Pull Box H2-10 (254) 햲 햲 Other standard heights 15 in. (381 mm) and 20 in. (508 mm). 햳 14 in. (356 mm) minimum width. Pull section widths may vary 햴 Add 11.5 in. (292 mm) for EUSERC Sections 152 W 14 (356) 20 (508) 32 (812) 38 (965) 32 (813) 38 (965) 46 (1168) 52 (1321) 20 (508) 32 (813) 38 (965) 20 (508) min. 14 (356) 20 (508) 14 (356) min. 햳 D NEMA 3R H1 D 94.25 (2394) Same as Main Section 91 (2311) 11 (279) 햴 94.25 (2394) Same as Metering Section Same as Main Section depending on local utility requirements. Siemens Electrical Products and Systems Specification Guide CSI Section 16470 Commercial Metering Switchboards Type SMM / SMD — For EUSERC Utility Area Installations 1. Scope Furnish and install, as shown on the plans, a metering switchboard as specified herein, for the system indicated below: 앮 120 / 240 앮 1-phase 앮 3-wire 앮 208Y / 120V 앮 3-phase 앮 4-wire 앮 480Y / 277V 앮 phase 앮 wire 앮 480V 앮 ______V 2. Configuration The switchboard enclosure shall be: 앮 Type 1 indoor construction 앮 Type 3R outdoor construction CSI Section 16470 5. Load Cables shall Exit 앮 Top 앮 Bottom 6. Bus Requirements The bus shall be 앮 tin plated aluminum, 앮 silver plated copper of sufficient size to limit the temperature rise to 65°C, based on UL tests. The bus shall be braced for 앮 50,000, 앮 75,000, 앮 100,000, 앮 200,000 amperes symmetrical and supported to withstand mechanical forces exerted during short circuit conditions when directly connected to a power source having the indicated available short circuit current. Provide a full capacity neutral when a neutral is indicated on the drawings. The through bus on the end metering section shall be extended and predrilled to allow the addition of future sections with standard splice plates. Ground bus and lugs shall be furnished — Ground bus shall extend the entire length of the switchboard and shall be firmly secured to each vertical section. Siemens Electrical Products and Systems Specification Guide 7. Main Protective Device (Select one of Item #C) The main protective device, to be installed in the main device section, shall be as indicated below: C-1 Molded case circuit breaker shall be of the quick-make, quick-break, trip-free, (heavy duty) (extra heavy duty) (solid state) type. It shall be _____ frame (2-pole) (3-pole) 600volt breaker with trip current rating of: 앮 400A 앮 600A 앮 800A 앮 1000A 앮 1200A 앮 1600A 앮 2000A 앮 2500A 앮 3000A of an interrupting capacity of not less than____amperes RMS symmetrical at the system voltage. The following accessory features are to be included: 앮 Shunt Trip, 앮 Ground Fault Relay, 앮 Electrical Operator, 앮 Integral ground fault trip (for solid state Sensitrip II breakers only). 앮 Other______(list) C-2 Fusible switch of the quick-make, quick-break type. It shall be a (2pole) (3-pole) (240V) (600V) VacuBreak unit with a continuous current rating of (400) (600) (800) (1200) amperes and with ____ ampere class ____ fuses, suitable for application on a system with _____ amperes symmetrical available fault current. C-3 Bolted pressure switch of the quick-make, quick-break type. It shall be 3-pole, 앮 240V, 앮 480V unit with a continuous current rating of: 앮 800A, 앮 1200A 앮 1600A 앮 2000A 앮 2500A 앮 3000A 앮 4000A. Provisions for Class L fuses shall be provided complete with mounting hardware. The following accessory features are to be included: 앮 Shunt Trip, 앮 Ground Fault Relay, 앮 Electrical Operator, 앮 Other _____(list) 153 8 Commercial Metering Switchboards 3. General The complete switchboard shall be phosphatized and finished with light gray, ANSI-61 paint. Each switchboard section shall have a nameplate permanently affixed to it, listing the following information: Name of manufacturer, System Voltage, Ampacity, Type, Manufacturer’s shop order number and date of manufacture. Each section of switchboard shall be of the required number of vertical sections bolted together to form one metal enclosed rigid switchboard. The sides, top and rear shall be covered with removable screw-on code gauge steel plates. Switchboard shall include all protective devices and equipment as listed on drawings with necessary interconnections, instrumentation and control wiring. Switchboard shall be constructed in accordance with the latest NEMA PB-2 and UL 891 standards. Meter sockets shall contain (test block) (lever bypass). Meter sockets shall be rated (100A) (200A) continuous duty. 4. Incoming Service 1. Underground Service: To isolate incoming underground service conductors, an underground cable pull or auxiliary section shall be used. This section shall be of the 앮 nonbussed, 앮 bussed type and shall be sealable per local utility requirements, 앮 utility studs, 앮 screw-type mechanical lugs, 앮 compression lugs to terminate, 앮 aluminum, 앮 copper cable, shall be furnished as detailed on the plans. 2. Overhead Service: Cable entry 앮 utility studs, 앮 screw-type mechanical lugs, 앮 compression lugs to terminate, 앮 aluminum, 앮 copper cable shall be furnished as detailed on the plans. Where necessary provide top cable pull box which shall be sealable per local utility requirements. Specifications Commercial Metering Switchboards Type SMM / SMD — For EUSERC Utility Area Installations 8. Tenant Branch Protective Devices (Select one of Item #D) All molded case circuit breakers, fusible switches, or fusible pullouts, used as a protective device in a branch circuit will meet the requirements of the appropriate paragraph below. D-1 Molded case circuit breakers shall be of quick-make, quick-break, trip free thermal magnetic type, with frame, trip and voltage ratings, either 2-pole or 3-pole, as indicated on the plans. All breakers shall have an interrupting capacity of not less than ______ amperes RMS symmetrical at the system voltage. All breakers shall be removable from the front of the switchboard without disturbing adjacent units. The switchboard shall have space or provisions for future units as shown on the plans. D-2 Current limiting circuit breakers shall provide inverse time delay, instantaneous circuit protection, and also limit the let-through l2t of one-half cycle wave of the symmetrical prospective current without any fusible elements. Breakers shall have an interrupting capacity of not less than ____ amperes RMS symmetrical at the system voltage. D-3 Fusible switches shall be quickmake, quick-break units utilizing the double-break principle of circuit interrupting to minimize arcing and pitting and shall conform to the ratings shown on the plans. Specifications Each switch shall have an individual door over the front, equipped with a voidable interlock that prevents the door from being opened when the switch is in the ON position unless the interlock is purposely defeated by activation of the voiding mechanism. All Switches shall have externally operated handles. Switches shall be equipped with 앮 NEC standard, 앮 Class R rejection type fuse holders, and class 앮 H, 앮 RK1, 앮 RK5, 앮 J and 앮 T fuses of ampere rating and type as indicated on the plans suitable for application on system with ____ampere symmetrical available fault current. D-4 Fusible pullouts for class T fuses. Commercial Metering Switchboards 8 Typical One-Line Horizontal Bus Horizontal Bus Type MMS The Service Section(s) for (lighting) (power) (lighting and power) shall be suitable for (underground) (overhead) service from _________Power Company lines. The Service Section shall contain space and mounting facilities for terminating power company cables in the ampere ratings and quantities shown on the plans. 154 Branch disconnects shall be (Siemens type BQ, QJ, etc...., quick-make, quickbreak thermal-magnetic circuit breakers) (Siemens type Vacu-Break quick-make, quick-break fusible switches) in the ratings and quantities shown on the plans. The main disconnect, when required, shall be installed in an enclosure to Siemens Electrical Products and Systems Specification Guide match the Service Section(s). Enclosures shall be bolted together and electrically connected by horizontal bus bar to form a complete assembly. Meter sockets shall contain (test block) (lever bypass). Meter sockets shall be rated (100A) (200A). CSI Section 16470
© Copyright 2024