AIRTREND Ltd - KOVENT DOO Kumanovska 14 11000 Beograd Tel: 011 3836886, 3085740 Faks: 011 3444113 e-mail: [email protected], [email protected] www.airtrend.rs, www.kovent.rs www.toshiba-klima.rs www.toshiba-estia.rs PRODUCT INFORMATION RAS Duct Type Indoor units for multi systems IntesisHome – WiFi solution for TOSHIBA AC RAV Preview: Small Digital Inverter expected 2015 Hot Water Module VRF Touch Screen Control Selection Tool „new“ A2W ESTIA Hi Power models Phone Conference 2014 © All provided materials for internal use only. 4 presented during PHONE CALL 12th Sept. 5 RAS DUCT TYPE Multi Indoor Unit 2 Product Information September 2014, Ver. 1.0 Air-Cond 2014 © For internal use only! presented during PHONE CALL 12th Sept. RAS DUCT TYPEmulti versionProduct information 1. COMPACT DESIGN 7 Very slim design with a height of only 210 mm for easier and versatile installations. Modell name: RAS-M**G3DV-E 210mm 450 mm Size 07/10/13: 700 Size 16: 900 September 2014 For internal use! mm mm presented during PHONE CALL 12th Sept. RAS DUCT TYPEmulti versionProduct information 1. COMPACT DESIGN – comparison of height and weight REDUCTION of height from 230 mm to 210 mm! REDUCTION of weight by 16 %! 16 % reduction New model WEIGHT: 16 kg * 210 mm Previous model Weight: 19 kg 20 mm reduction * Weight of RAS-M16G3V-E is 19 kg! September 2014 For internal use! 230 mm 8 presented during PHONE CALL 12th Sept. RAS DUCT TYPEmulti versionProduct information 1. COMPACT DESIGN – application Ducted indoor unit fits various scenes, like a high class condominium, a villa and a house. September 2014 For internal use! 9 presented during PHONE CALL 12th Sept. RAS DUCT TYPEmulti versionProduct information 2. LOW SOUND – cooling operation 10 RAS-M**G3DV-E Cooling mode 10 (2,7 kW) 13 (3,7 kW) 16 (4,5 kW) Air flow (high/low) m3/h 570/380 610/385 780/420 Sound power level dB(A) 50/42 52/42 50/39 Sound pressure level dB(A) 35/27 37/27 35/24 Rooms air conditioned with duct type models are as quiet as a whisper. Expamples for sound pressure 40 dB(A) library 30 dB(A) whisper 20 dB(A) breath September 2014 For internal use! presented during PHONE CALL 12th Sept. RAS DUCT TYPEmulti versionProduct information 2. LOW SOUND – heating operation 11 RAS-M**G3DV-E Heating mode 10 (4,0 kW) 13 (5,0 kW) 16 (5,5 kW) Air flow (high/low) m3/h 570/380 610/385 780/450 Sound power level dB(A) 50/42 52/42 50/40 Sound pressure level dB(A) 35/27 37/27 35/25 Rooms air conditioned with duct type models are quieter than a library! Expamples for sound pressure 40 dB(A) library 30 dB(A) whisper 20 dB(A) breath September 2014 For internal use! presented during PHONE CALL 12th Sept. RAS DUCT TYPEmulti versionProduct information 3. EASY INSTALLATION DRAIN PUMP as a standard included in order to save costs and working process for installation. Refrigerant piping connection changed to side from front for easier installation. September 2014 For internal use! 12 drain water drain up height within 350 mm presented during PHONE CALL 12th Sept. RAS DUCT TYPEmulti versionProduct information 3. EASY INSTALLATION & MAINTENANCE 15 FLEXIBLE AIR INTAKE rear or below the unit up to your room Air discharge Air discharge Air intake Air intake Air intake Air discharge Air intake Air intake September 2014 For internal use! presented during PHONE CALL 12th Sept. RAS DUCT TYPEmulti versionProduct information 4. USER FRIENDLY Flexible external static pressure control in four 4 steps. External static pressure DEFAULT 10 Pa Low pressure 20 Pa Middle pressure 35 Pa High pressure 45 Pa September 2014 For internal use! 16 presented during PHONE CALL 12th Sept. RAS DUCT TYPEmulti versionProduct information 4. USER FRIENDLY – wireless remote controller Main Function One-touch Quiet store your desired settings and activate them at the touch of a button possible to operate at super low fan speed for quiet operation (except in dry mode) Comfort sleep Hi Power for optimum comfort, set temperature is automatically risen by 1°C after 1 hour, then another degree after 2 hours, which will be maintained until morning possible to automatically control room temperature and cooling or heating capacity for faster cooling or heating operation (except in dry mode) Eco possible to automatically control room to save energy (except in dry mode) September 2014 For internal use! 18 RAS DUCT TYPEmulti versionProduct information presented during PHONE CALL 12th Sept. 4. USER FRIENDLY – optional wired remote controller Wired remote control with weekly timer Model: RB-RWS20-E QUIET Mode HI POWER ECO TIMER Button layout (1) ON/OFF button (2) & (3) Set temp. up & down (4) Menu button (5) Left function button (F1button) 8 5 4 2 7 3 6 (6) Right function button (F2button) The button LED lights while the ac unit is running. 1 9 9 (7) Cancel button & Return button (8) Monitor button (9) Temperature -sensor September 2014 For internal use! 19 27 External Control Option Product information September 2014, Ver. 1.0 Air-Cond 2014 © For internal use only! presented during PHONE CALL 12th Sept. INTESIS HOME ®New Control OptionProduct information 28 What is INTESIS HOME ®? IntesisHome is a controlling and monitoring system composed by a wireless device attached to the indoor air conditioning unit. You use it with your smartphone, tablet or PC through the Internet. September 2014 For internal use only! How does it work? • The Air Conditioning units are controlled from a webpage or using an IOS or Android APP in a very intuitive way. • A wireless or wired WiFi- device installed in each unit controls the operation. • A server in the cloud manages the whole process. presented during PHONE CALL 12th Sept. INTESIS HOME ®New Control OptionProduct information 29 The basic principle September 2014 For internal use only! A/C unit External module – communicating via infrared or cable Control via Smartphone, Tablet or PC WiFi presented during PHONE CALL 12th Sept. INTESIS HOME ®New Control OptionProduct information 30 What can be controlled? Set temperature Operation mode Fan Speed Louvre position September 2014 For internal use only! What is displayed? Ambient temperature Operating status Feedback about any changes Failure allert presented during PHONE CALL 12th Sept. INTESIS HOME ®New Control OptionProduct information 31 Note: No Combination with RBC-AMS51E-ES! September 2014 For internal use only! presented during PHONE CALL 12th Sept. INTESIS HOME ®New Control OptionProduct information 32 Price information September 2014 For internal use only! PREVIEW: Small Digital Inverter Indoor Units SIZE 2,5 / 3,6 kW Outdoor units Indoor units hi wall ceiling slim duct type 60x60 4-way cassette AVAILABLE: January 2015 Documentation: November 2014 Phone Conference 2014 © All provided materials for internal use only. 35 37 HOT WATER MODULE Specification 1. 2. 3. 4. 5. LWT – 45°C to 50°C Heating only Product Model codes • 8 kW: MMM-APO271LQ-E • 16kW: MMM-APO541LQ-E Operating range -20°C - +19°C 2-pipe connection only at first launch Connectivity 1. 2. 3. Phone Conference 2014 © All provided materials for internal use only. Connection ratio maximum 50 % / FCU capacity Total system diversity 90-105 % Maximum number of 2 HWMs per system. presented during PHONE CALL 12th Sept. 39 TOUCH SCREEN Controller Product Information September 2014, Ver. 1.0 Air-Cond 2014 © For internal use only! presented during PHONE CALL 12th Sept. TOUCH SCREEN new modelProduct information 1 HIGH USER COMFORT 41 High definition display This display realizes a high level of definition, a high image quality and sharpness. New model September 2014 For internal use! presented during PHONE CALL 12th Sept. TOUCH SCREEN new modelProduct information 1 HIGH USER COMFORT 42 Smoothing touch display You can see other information to scroll on a screen smoothly without flipping a screen. New model The display of new Touch Screen Controller has adopted panel of capacitance type also smart phone September 2014 For internal use! presented during PHONE CALL 12th Sept. TOUCH SCREEN new modelProduct information 2 CONTROL UP TO 512 INDOOR UNITS 43 It is possible to connect max. 512 indoor units to the touch screen controller. September 2014 For internal use! presented during PHONE CALL 12th Sept. TOUCH SCREEN new modelProduct information 3 COMPACT DESIGN 44 The design of the new touch screen control is very compact. Dimension 255mm 322mm 49mm September 2014 For internal use! Width 322 mm Height 255 mm Depth 49 mm Weight 4.3 kg Display 30,7 cm presented during PHONE CALL 12th Sept. TOUCH SCREEN new modelProduct information 4 EASY INSTALLATION 46 It is possible to hang the new Touch Screen Controller on a wall easily without making an embedment hole because of flat back side design. If you install New Touch Screen Controller in a wall, it fits your wall because the exposed part (display part) is very thin. September 2014 For internal use! presented during PHONE CALL 12th Sept. TOUCH SCREEN new modelProduct information 47 SPECIFICATIONS Model name BMS-CT5120E Power supply (rated) AC 220V-240V 50/60Hz Energy consumption 28 W Weight Main unit: 3.4kg / Power adapter: 0.3kg Operating temp. range 0 °C to 40 °C, 10% to 90% RH (no condensation) Storage temp. range -10 °C to 60 °C Graphic mode 1,024*768 Color 262,144 color Brightness 600cd/m2 3 way installation In wall, wall mount and VESA Max. input port 2 points simultaneously Max. connectable indoor units 512 units September 2014 For internal use! presented during PHONE CALL 12th Sept. TOUCH SCREEN new modelProduct information Connectable interfaces Interface 58 Model name Notes Relay interface BMS-IFLSV4E For TCS-NET Max. 64 units Energy monitoring relay interface BMS-IFWH5E For energy monitoring Max. 8 units Digital I/O relay interface BMS-IFDD03E For digital input or output Max. 8 units September 2014 For internal use! NEW VRF SELECTION TOOL Improved software to design TOSHIBA VRF systems, featuring also DX-Kit and hot water module. Development in the UK by EMEA „European Version“ Launch of English Version: November 2014 Launch of different languages: immediately after translation; expected begin of 2015 Main improvements: user friendly & better layout Phone Conference 2014 © All provided materials for internal use only. 73 74 BETTER LAYOUT! Current Selection Tool Software Phone Conference 2014 © All provided materials for internal use only. New TOSHIBA Design-Airs BETTER LAYOUT! Phone Conference 2014 © All provided materials for internal use only. 75 FEATURES • • • • • • • • • • • • Modern feel, ease of use Fast design method for quick quotation Intuitive Controls capability Wiring schematics (System/Central) Improved project outputs Floor / Room Designs Refrigerant leak density requirements Live updates Selectable TOSHIBA specification output (NC, Dimensions, etc.) Greater flexibility Improved design error feedback system Phone Conference 2014 © All provided materials for internal use only. 76 presented during PHONE CALL 12th Sept. 78 AIR-TO-WATER HEAT PUMP HIGH POWER Product Info August 2014 Air-Cond 2014 © For internal use only! presented during PHONE CALL 12th Sept. A2W heat pumpHI POWER Product Information AIR-TO-WATER HEAT PUMP HIGH POWER • • ESTIA air-to-water line-up has been extended. From November 2014 there will be available „HI POWER“ models. ESTIA CONCEPT No. 1 COP Combination flexibility 2-zone temperature control August 2014 For internal use only! 79 presented during PHONE CALL 12th Sept. A2W heat pumpHI POWER Product Information 80 LINE-UP • • • 8 & 11 kW 1-phase available from mid of November 2014 8 kW Hydro box 11 kW Model name 8 kW Exterior kW Power Supply 8,0 / 6,0 50Hz 1~220-230V HWS-P804HR-E 11,2 / 10,0 50Hz 1~220-230V HWS-P1104HR-E August 2014 For internal use only! Model name Note HWS-P804XWHM3-E 1ph+N, 220~230V 3 kW back up heater HWS-P804XWHT6-E 2ph+N, 380~400V 6 kW back up heater HWS-P804XWHT9-E 3ph+N, 380~400V 9 kW back up heater HWS-P1104XWHM3-E 1ph+N, 220~230V 3 kW back up heater HWS-P1104XWHT6-E 2ph+N, 380~400V 6 kW back up heater HWS-P1104XWHT9-E 3ph+N, 380~400V 9 kW back up heater Outdoor unit 11,2 kW • • presented during PHONE CALL 12th Sept. A2W heat pumpHI POWER Product Information 81 ACCESSORIES • Remote control: HWS-AMS11E • Temperature sensor: 95612037 • External input board: TCB-PCM03E • External output board: TCB-PCIN3E August 2014 For internal use only! presented during PHONE CALL 12th Sept. A2W heat pumpHI POWER Product Information 82 ESTIA HI POWER For low ambient area and / or areas, where high water temperature is required. Perfect for renovation! FEATURES • Operation range down to – 25 °C • Maintain the rated capacity down to – 15 °C • Producing leaving water temperature up to 60 °C - 25°C PERFECT FOR REFURBISHMENT & CONTINUED USE OF RADIATORS! August 2014 For internal use only! 60°C A2W heat pumpHI POWER Product Information presented during PHONE CALL 12th Sept. 84 1. Keep high capacity at lower ambient Maintain the rated capacity down to OAT -15oC. Maximum capacity (Peak) 30 Current model 25 Capacity (kW) 12 9 Powerful type 20 6 15 44% Improve 8.0 kW 32% Improve 11.0k W 9.67k W New 5.74 kW Current 3 10 5 Rated capacity :11.2kW 0 0 -20 -15 -10 -5 Outside temperature August 2014 For internal use only! 0 (oC) 5 10 8kW 11kW Expected capacity at -15oC ambient presented during PHONE CALL 12th Sept. A2W heat pumpHI POWER Product Information 87 4. OAT -25oC operation Anti ice heater and refrigerant path are standard equipment to prevent heat exchanger unit in CDU from the frost or ice. Without Anti ice path August 2014 For internal use only! With Anti ice path presented during PHONE CALL 12th Sept. A2W heat pumpHI POWER Product Information KEY SPECIFICATION 88 ESTIA Model 8 kW Power supply Heating 30°C 35°C operation outdoor temp. condition 7/6°C Cooling 12°C7°C operation outdoor temp. condition 35/-°C Leaving hot water temperature [°C] Hydro box 50 Hz 1 Phase 220~230V Heating power 8,0 kW 11,2 kW Power input 1,68 2,30 COP 4,76 4,88 Cooling power 6,0 10,0 Power input 1,64 3,33 EER 3,66 3,0 Heating: leaving hot water temp. 20 ~ 60 °C Cooling: leaving cold water temp. 7 ~ 25 °C Dimensions (HxWxD) [mm] Packing weight (net) [kg] Back up heater Outdoor unit 11 kW Dimensions (HxWxD) [mm] Packing weight (net) [kg] Electric heater 925 x 525 x 355 925 x 525 x 355 53 (49) 56 (52) 3, 6, 9 kW 1340 x 900 x 320 99 (92) 75 W Sound pressure level (out) Heating/Cooling (SPL) [DB] 51 / 49 Refrigerant charged (R410A) 2,7 kg Operation outdoor temp. [°C] Hot water/Heating/Cooling August 2014 For internal use only! -25 ~ 43 / -25 ~ 25 / 10~ 43 °C
© Copyright 2024