A2W heat pump

AIRTREND Ltd - KOVENT DOO
Kumanovska 14
11000 Beograd
Tel: 011 3836886, 3085740
Faks: 011 3444113
e-mail: [email protected], [email protected]
www.airtrend.rs, www.kovent.rs
www.toshiba-klima.rs
www.toshiba-estia.rs
PRODUCT INFORMATION
RAS
Duct Type Indoor units for multi systems
IntesisHome – WiFi solution for TOSHIBA AC
RAV
Preview: Small Digital Inverter expected 2015
Hot Water Module
VRF
Touch Screen Control
Selection Tool „new“
A2W
ESTIA Hi Power models
Phone Conference 2014 © All provided materials for internal use only.
4
presented during PHONE CALL 12th Sept.
5
RAS DUCT TYPE
Multi Indoor Unit
2
Product Information September 2014, Ver. 1.0 Air-Cond 2014 ©
For internal use only!
presented during PHONE CALL 12th Sept.
RAS DUCT TYPEmulti versionProduct information
1. COMPACT DESIGN
7
Very slim design with a height of only 210 mm for easier and versatile installations.
Modell name: RAS-M**G3DV-E
210mm
450 mm
Size 07/10/13: 700
Size 16: 900
September 2014 For internal use!
mm
mm
presented during PHONE CALL 12th Sept.
RAS DUCT TYPEmulti versionProduct information
1. COMPACT DESIGN – comparison of height and weight
REDUCTION of height from 230 mm to 210 mm!
REDUCTION of weight by 16 %!
16 %
reduction
New model
WEIGHT: 16 kg *
210 mm
Previous model
Weight: 19 kg
20 mm
reduction
* Weight of RAS-M16G3V-E is 19 kg!
September 2014 For internal use!
230 mm
8
presented during PHONE CALL 12th Sept.
RAS DUCT TYPEmulti versionProduct information
1. COMPACT DESIGN – application
Ducted indoor unit fits various scenes,
like a high class condominium, a villa
and a house.
September 2014 For internal use!
9
presented during PHONE CALL 12th Sept.
RAS DUCT TYPEmulti versionProduct information
2. LOW SOUND – cooling operation
10
RAS-M**G3DV-E
Cooling mode
10
(2,7 kW)
13
(3,7 kW)
16
(4,5 kW)
Air flow (high/low) m3/h
570/380
610/385
780/420
Sound power level dB(A)
50/42
52/42
50/39
Sound pressure level dB(A)
35/27
37/27
35/24
Rooms air conditioned with duct type
models are as quiet as a whisper.
Expamples for sound pressure
40 dB(A)
library
30 dB(A)
whisper
20 dB(A)
breath
September 2014 For internal use!
presented during PHONE CALL 12th Sept.
RAS DUCT TYPEmulti versionProduct information
2. LOW SOUND – heating operation
11
RAS-M**G3DV-E
Heating mode
10
(4,0 kW)
13
(5,0 kW)
16
(5,5 kW)
Air flow (high/low) m3/h
570/380
610/385
780/450
Sound power level dB(A)
50/42
52/42
50/40
Sound pressure level dB(A)
35/27
37/27
35/25
Rooms air conditioned with duct type
models are quieter than a library!
Expamples for sound pressure
40 dB(A)
library
30 dB(A)
whisper
20 dB(A)
breath
September 2014 For internal use!
presented during PHONE CALL 12th Sept.
RAS DUCT TYPEmulti versionProduct information
3. EASY INSTALLATION
DRAIN PUMP as a standard included in
order to save costs and working process
for installation.
Refrigerant piping connection
changed to side from front for
easier installation.
September 2014 For internal use!
12
drain water
drain up
height within
350 mm
presented during PHONE CALL 12th Sept.
RAS DUCT TYPEmulti versionProduct information
3. EASY INSTALLATION & MAINTENANCE
15
FLEXIBLE AIR INTAKE
rear or below the unit up to your room
Air discharge
Air discharge
Air intake
Air intake
Air intake
Air discharge
Air intake
Air intake
September 2014 For internal use!
presented during PHONE CALL 12th Sept.
RAS DUCT TYPEmulti versionProduct information
4. USER FRIENDLY
Flexible external static pressure control in four 4 steps.
External static pressure
DEFAULT
10 Pa
Low pressure
20 Pa
Middle pressure
35 Pa
High pressure
45 Pa
September 2014 For internal use!
16
presented during PHONE CALL 12th Sept.
RAS DUCT TYPEmulti versionProduct information
4. USER FRIENDLY – wireless remote controller
Main Function
One-touch
Quiet
store your desired settings and activate
them at the touch of a button
possible to operate at super low fan speed
for quiet operation (except in dry mode)
Comfort sleep
Hi Power
for optimum comfort, set temperature is
automatically risen by 1°C after 1 hour,
then another degree after 2 hours, which
will be maintained until morning
possible to automatically control room
temperature and cooling or heating
capacity for faster cooling or heating
operation (except in dry mode)
Eco
possible to automatically control room to
save energy (except in dry mode)
September 2014 For internal use!
18
RAS DUCT TYPEmulti versionProduct information
presented during PHONE CALL 12th Sept.
4. USER FRIENDLY – optional wired remote controller
Wired remote control with weekly timer
Model: RB-RWS20-E

QUIET Mode

HI POWER

ECO

TIMER
Button layout
(1) ON/OFF button
(2) & (3) Set temp. up & down
(4) Menu button
(5) Left function button (F1button)
8
5
4
2
7
3
6
(6) Right function button (F2button)
The button LED lights while
the ac unit is running.
1
9
9
(7) Cancel button & Return button
(8) Monitor button
(9) Temperature -sensor
September 2014 For internal use!
19
27
External Control
Option
Product information September 2014, Ver. 1.0 Air-Cond 2014 ©
For internal use only!
presented during
PHONE CALL 12th Sept.
INTESIS HOME ®New Control OptionProduct information
28
What is INTESIS HOME ®?
IntesisHome is a controlling and monitoring
system composed by a wireless device attached
to the indoor air conditioning unit.
You use it with your smartphone, tablet or PC
through the Internet.
September 2014 For internal use only!
How does it work?
• The Air Conditioning units are controlled from a
webpage or using an IOS or Android APP in a very
intuitive way.
•
A wireless or wired WiFi- device installed in each
unit controls the operation.
• A server in the cloud manages the whole process.
presented during
PHONE CALL 12th Sept.
INTESIS HOME ®New Control OptionProduct information
29
The basic principle




September 2014 For internal use only!
A/C unit
External module –
communicating via infrared or
cable
Control via Smartphone, Tablet
or PC
WiFi
presented during
PHONE CALL 12th Sept.
INTESIS HOME ®New Control OptionProduct information
30
What can be controlled?




Set temperature
Operation mode
Fan Speed
Louvre position
September 2014 For internal use only!
What is displayed?




Ambient temperature
Operating status
Feedback about any changes
Failure allert
presented during
PHONE CALL 12th Sept.
INTESIS HOME ®New Control OptionProduct information
31
Note: No Combination with RBC-AMS51E-ES!
September 2014 For internal use only!
presented during
PHONE CALL 12th Sept.
INTESIS HOME ®New Control OptionProduct information
32
Price information
September 2014 For internal use only!
PREVIEW: Small Digital Inverter Indoor Units
SIZE 2,5 / 3,6 kW
 Outdoor units
 Indoor units
hi wall
ceiling
slim duct type
60x60 4-way cassette
AVAILABLE: January 2015
Documentation: November 2014
Phone Conference 2014 © All provided materials for internal use only.
35
37
HOT WATER MODULE
Specification
1.
2.
3.
4.
5.
LWT – 45°C to 50°C
Heating only
Product Model codes
• 8 kW: MMM-APO271LQ-E
• 16kW: MMM-APO541LQ-E
Operating range -20°C - +19°C
2-pipe connection only at first launch
Connectivity
1.
2.
3.
Phone Conference 2014 © All provided materials for internal use only.
Connection ratio maximum 50 % / FCU capacity
Total system diversity 90-105 %
Maximum number of 2 HWMs per system.
presented during PHONE CALL 12th Sept.
39
TOUCH SCREEN
Controller
Product Information September 2014, Ver. 1.0 Air-Cond 2014 ©
For internal use only!
presented during PHONE CALL 12th Sept.
TOUCH SCREEN new modelProduct information
1 HIGH USER COMFORT
41
High definition display
This display realizes a high level of
definition, a high image quality and
sharpness.
New model
September 2014 For internal use!
presented during PHONE CALL 12th Sept.
TOUCH SCREEN new modelProduct information
1 HIGH USER COMFORT
42
Smoothing touch display
You can see other information to
scroll on a screen smoothly without
flipping a screen.
New model
The display of new Touch Screen
Controller has adopted panel of
capacitance type also smart phone
September 2014 For internal use!
presented during PHONE CALL 12th Sept.
TOUCH SCREEN new modelProduct information
2 CONTROL UP TO 512 INDOOR UNITS
43
It is possible to connect max. 512 indoor
units to the touch screen controller.
September 2014 For internal use!
presented during PHONE CALL 12th Sept.
TOUCH SCREEN new modelProduct information
3 COMPACT DESIGN
44
The design of the new touch screen control
is very compact.
Dimension
255mm
322mm
49mm
September 2014 For internal use!
Width
322 mm
Height
255 mm
Depth
49 mm
Weight
4.3 kg
Display
30,7 cm
presented during PHONE CALL 12th Sept.
TOUCH SCREEN new modelProduct information
4 EASY INSTALLATION
46
It is possible to hang the new Touch Screen
Controller on a wall easily without making an
embedment hole because of flat back side
design.
If you install New Touch Screen Controller in a
wall, it fits your wall because the exposed part
(display part) is very thin.
September 2014 For internal use!
presented during PHONE CALL 12th Sept.
TOUCH SCREEN new modelProduct information
47
SPECIFICATIONS
Model name
BMS-CT5120E
Power supply (rated)
AC 220V-240V 50/60Hz
Energy consumption
28 W
Weight
Main unit: 3.4kg / Power adapter: 0.3kg
Operating temp. range
0 °C to 40 °C, 10% to 90% RH
(no condensation)
Storage temp. range
-10 °C to 60 °C
Graphic mode
1,024*768
Color
262,144 color
Brightness
600cd/m2
3 way installation
In wall, wall mount and VESA
Max. input port
2 points simultaneously
Max. connectable indoor units
512 units
September 2014 For internal use!
presented during PHONE CALL 12th Sept.
TOUCH SCREEN new modelProduct information
Connectable interfaces
Interface
58
Model name
Notes
Relay interface
BMS-IFLSV4E
For TCS-NET
Max. 64 units
Energy monitoring relay interface
BMS-IFWH5E
For energy monitoring
Max. 8 units
Digital I/O relay interface
BMS-IFDD03E
For digital input or output
Max. 8 units
September 2014 For internal use!
NEW VRF SELECTION TOOL
Improved software to design TOSHIBA VRF systems,
featuring also DX-Kit and hot water module.
Development in the UK by EMEA  „European Version“
Launch of English Version: November 2014
Launch of different languages:  immediately after
translation; expected begin of 2015
Main improvements:
user friendly & better layout
Phone Conference 2014 © All provided materials for internal use only.
73
74
BETTER LAYOUT!
Current Selection Tool Software
Phone Conference 2014 © All provided materials for internal use only.
New TOSHIBA Design-Airs
BETTER LAYOUT!
Phone Conference 2014 © All provided materials for internal use only.
75
FEATURES
•
•
•
•
•
•
•
•
•
•
•
•
Modern feel, ease of use
Fast design method for quick quotation
Intuitive
Controls capability
Wiring schematics (System/Central)
Improved project outputs
Floor / Room Designs
Refrigerant leak density requirements
Live updates
Selectable TOSHIBA specification output (NC, Dimensions, etc.)
Greater flexibility
Improved design error feedback system
Phone Conference 2014 © All provided materials for internal use only.
76
presented during PHONE CALL 12th Sept.
78
AIR-TO-WATER HEAT PUMP
HIGH POWER
Product Info August 2014 Air-Cond 2014 ©
For internal use only!
presented during PHONE CALL 12th Sept.
A2W heat pumpHI POWER Product Information
AIR-TO-WATER HEAT PUMP
HIGH POWER
•
•
ESTIA air-to-water line-up has
been extended.
From November 2014 there will
be available „HI POWER“ models.
ESTIA CONCEPT
 No. 1 COP
 Combination flexibility
 2-zone temperature control
August 2014 For internal use only!
79
presented during PHONE CALL 12th Sept.
A2W heat pumpHI POWER Product Information
80
LINE-UP
•
•
•
8 & 11 kW
1-phase
available from mid of November 2014
8 kW
Hydro box
11 kW
Model name
8 kW
Exterior
kW
Power Supply
8,0 / 6,0
50Hz 1~220-230V
HWS-P804HR-E
11,2 / 10,0
50Hz 1~220-230V
HWS-P1104HR-E
August 2014 For internal use only!
Model name
Note
HWS-P804XWHM3-E
1ph+N, 220~230V
3 kW back up heater
HWS-P804XWHT6-E
2ph+N, 380~400V
6 kW back up heater
HWS-P804XWHT9-E
3ph+N, 380~400V
9 kW back up heater
HWS-P1104XWHM3-E
1ph+N, 220~230V
3 kW back up heater
HWS-P1104XWHT6-E
2ph+N, 380~400V
6 kW back up heater
HWS-P1104XWHT9-E
3ph+N, 380~400V
9 kW back up heater
Outdoor unit
11,2 kW
•
•
presented during PHONE CALL 12th Sept.
A2W heat pumpHI POWER Product Information
81
ACCESSORIES
•
Remote control: HWS-AMS11E
•
Temperature sensor: 95612037
•
External input board: TCB-PCM03E
•
External output board: TCB-PCIN3E
August 2014 For internal use only!
presented during PHONE CALL 12th Sept.
A2W heat pumpHI POWER Product Information
82
ESTIA HI POWER
For low ambient area and / or areas, where high water temperature is required.
Perfect for renovation!
FEATURES
•
Operation range down to – 25 °C
•
Maintain the rated capacity down to – 15 °C
•
Producing leaving water temperature up to 60 °C
- 25°C
PERFECT FOR REFURBISHMENT & CONTINUED USE
OF RADIATORS!
August 2014 For internal use only!
60°C
A2W heat pumpHI POWER Product Information
presented during PHONE CALL 12th Sept.
84
1. Keep high capacity at lower ambient
Maintain the rated capacity down to OAT -15oC.
Maximum capacity (Peak)
30
Current model
25
Capacity (kW)
12
9
Powerful type
20
6
15
44%
Improve
8.0
kW
32%
Improve
11.0k
W
9.67k
W
New
5.74
kW
Current
3
10
5
Rated capacity :11.2kW
0
0
-20
-15
-10
-5
Outside temperature
August 2014 For internal use only!
0
(oC)
5
10
8kW
11kW
Expected capacity at -15oC ambient
presented during PHONE CALL 12th Sept.
A2W heat pumpHI POWER Product Information
87
4. OAT -25oC operation
Anti ice heater and refrigerant path are standard equipment to prevent heat
exchanger unit in CDU from the frost or ice.
Without Anti ice path
August 2014 For internal use only!
With Anti ice path
presented during PHONE CALL 12th Sept.
A2W heat pumpHI POWER Product Information
KEY SPECIFICATION
88
ESTIA
Model
8 kW
Power supply
Heating
30°C 35°C operation
outdoor temp. condition 7/6°C
Cooling
12°C7°C operation
outdoor temp. condition 35/-°C
Leaving hot water temperature [°C]
Hydro box
50 Hz 1 Phase 220~230V
Heating power
8,0 kW
11,2 kW
Power input
1,68
2,30
COP
4,76
4,88
Cooling power
6,0
10,0
Power input
1,64
3,33
EER
3,66
3,0
Heating: leaving hot water temp.
20 ~ 60 °C
Cooling: leaving cold water temp.
7 ~ 25 °C
Dimensions (HxWxD) [mm]
Packing weight (net) [kg]
Back up heater
Outdoor unit
11 kW
Dimensions (HxWxD) [mm]
Packing weight (net) [kg]
Electric heater
925 x 525 x 355
925 x 525 x 355
53 (49)
56 (52)
3, 6, 9 kW
1340 x 900 x 320
99 (92)
75 W
Sound pressure level (out) Heating/Cooling (SPL) [DB]
51 / 49
Refrigerant charged (R410A)
2,7 kg
Operation outdoor temp. [°C] Hot water/Heating/Cooling
August 2014 For internal use only!
-25 ~ 43 / -25 ~ 25 / 10~ 43 °C